首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Zhang L  Yin X 《Electrophoresis》2007,28(8):1281-1288
A simple and powerful microfluidic array chip-based electrophoresis system, which is composed of a 3-D microfluidic array chip, a microvacuum pump-based negative pressure sampling device, a high-voltage supply and an LIF detector, was developed. The 3-D microfluidic array chip was fabricated with three glass plates, in which a common sample waste bus (SW(bus)) was etched in the bottom layer plate to avoid intersecting with the separation channel array. The negative pressure sampling device consists of a microvacuum air pump, a buffer vessel, a 3-way electromagnet valve, and a vacuum gauge. In the sample loading step, all the six samples and buffer solutions were drawn from their reservoirs across the injection intersections through the SW(bus) toward the common sample waste reservoir (SW(T)) by negative pressure. Only 0.5 s was required to obtain six pinched sample plugs at the channel crossings. By switching the three-way electromagnetic valve to release the vacuum in the reservoir SW(T), six sample plugs were simultaneously injected into the separation channels by EOF and electrophoretic separation was activated. Parallel separations of different analytes are presented on the 3-D array chip by using the newly developed sampling device.  相似文献   

2.
Packaging of microfluidic chips via interstitial bonding technique.   总被引:2,自引:0,他引:2  
In this paper, we describe an interstitial bonding technique for packaging of microfluidic chips. The cover plate is first placed on top of the microfluidic chip, followed by dispensing the UV-curable resin into the resin-loading reservoirs. With the interstitial space between the cover plate and the microfluidic chip connecting to the loading reservoirs, the UV-curable resin wicks through capillary force action and hydrostatic pressure generated by the liquid level in the resin-loading reservoirs. When reaching the microchannels, the UV-curable resin stops flowing into the microchannels due to the force balance between the surface tension and hydrostatic pressure. The assembly is then placed under the UV light, followed by further curing in the thermal oven. It is found that there is no leakage from the bonded microfluidic chips and a good DNA separation result was obtained by using the microfluidic chips as fabricated. This bonding technique is relatively simple and fast, which can be applied to the packaging of microfluidic chips made from hybrid materials with complicated designs as long as the interstitial space connects to the loading reservoirs.  相似文献   

3.
单细胞分析的研究   总被引:1,自引:0,他引:1  
程介克  黄卫华  王宗礼 《色谱》2007,25(1):1-10
单细胞分析是分析化学、生物学和医学之间渗透发展形成的跨学科前沿领域。近年来,毛细管电泳及微流控芯片用于单细胞分析已取得显著进展,特别表现在微流控芯片用于细胞的培养、分选、操纵、定位、分离及检测细胞的组分,实时监测细胞释放,及高通量阵列检测等方面。芯片的单元操作可根据需要灵活组合,显示出其独特的优点。本文重点介绍作者研究组的工作,并对近三年来国内外在毛细管电泳及芯片毛细管电泳用于单细胞分析的新进展进行评论。最后从毛细管电泳与微流控芯片、微流控芯片与细胞界面以及量子点用于探测活细胞等方面,展望了单细胞分析的发展前景。  相似文献   

4.
Park S  Hong X  Choi WS  Kim T 《Lab on a chip》2012,12(20):3914-3922
We describe a microfluidic concentrator array device that is integrated with microfabricated ratchet structures to concentrate motile bacterial cells in desired destinations with required cell densities. The device consists of many pairs of concentrators with a wide range of spacing distances on a chip, and allows cells in one concentrator to be physically separated from but chemically connected to cells in the other concentrator. Therefore, the device facilitates quantification of the effect of spacing distance on the cell-to-cell communication of synthetically engineered bacterial cells. In addition, the device enables us to control the cell number density in each concentrator unit by adjusting the concentration time and the density of cell suspensions, and the basic concentrator unit of the device can be repeatedly duplicated on a chip. Hence, the device not only facilitates an investigation of the effect of cell densities on cell-to-cell communication, but it can also be further applied to an investigation of cellular communication among multiple types of cells. Lastly, the device can be easily fabricated using a single-layered soft-lithography technology so that we believe it would provide a simple but robust means for many synthetic and systems biologists to simplify and speed up their investigations of the synthetic genetic circuits in bacterial cells.  相似文献   

5.
Optimization based on central composite design (CCD) for enantioseparation of anisodamine (AN), atenolol (AT), and metoprolol (ME) in human urine was developed using a microfluidic chip‐CE device. Coupling the flexible and wide working range of microfluidic chip‐CE device to CCD for chiral separation of AN, AT, and ME in human urine, a total of 15 experiments is needed for the optimization procedure as compared to 75 experiments using the normal one variable at a time optimization. The optimum conditions obtained are found to be more robust as shown by the curvature effects of the interaction factors. The developed microfluidic chip‐CE‐ECL system with adjustable dilution ratios has been validated by satisfactory recoveries (89.5–99% for six enanotiomers) in urine sample analysis. The working range (0.3–600 μM), repeatability (3.1–4.9% RSD for peak height and 4.0–5.2% RSD for peak area), and detection limit (0.3–0.6 μM) of the method developed are found to meet the requirements for bedside monitoring of AN, AT, and ME in patients under critical conditions. In summary, the hyphenation of CCD with the microfluidic chip‐CE device is shown to offer a rapid means for optimizing the working conditions on simultaneous separation of three racemic drugs using the microfluidic chip‐CE device developed.  相似文献   

6.
A surface plasmon resonance (SPR) sensor on a compact disk (CD)-type microfluidic device was developed to miniaturize the elements of a complete analytical system, pump and valves. The CD-type microfluidic device was fabricated by attaching a polydimethylsiloxane disk plate that contained microchannels and reservoirs to a flat polycarbonate disk plate that contained grating films with a thin layer of Au. The optical system of the SPR sensor and the theory for its operation are based on the principle of a grating coupled-type SPR. The sample and reagent solutions in the reservoirs on the CD-type microfluidic device were sequentially introduced into the detection chamber by centrifugal force generated by the rotation of the microfluidic device. The variation of resonance wavelength was dependent on the refractive index of the sample solution. This CD-type SPR sensor was successfully used in an immunoassay of immunoglobulin A (IgA). The anti-IgA, blocking reagent, sample and washing solution in the reservoirs were sequentially introduced into the detection chamber by changing the frequency of rotation of the microfluidic device. IgA in the sample solution was adsorbed to the anti-IgA immobilized on the Au thin layer in the detection chamber and was then detected by the SPR sensor.  相似文献   

7.
We present a 3-D microfluidic device designed for localized drug delivery to cellular networks. The device features a flow cell comprising a main channel for nutrient delivery as well as multiple channels for drug delivery. This device is one key component of a larger, fully integrated system now under development, based upon a microelectrode array (MEA) with on-chip CMOS circuitry for recording and stimulation of electrogenic cells (e.g. neurons, cardiomyocytes). As a critical system unit, the microfluidics must be carefully designed and characterized to ensure that candidate drugs are delivered to specific regions of the culture at known concentrations. Furthermore, microfluidic design and functionality is dictated by the size, geometry, and material/electrical characteristics of the CMOS MEA. Therefore, this paper reports on the design considerations and fabrication of the flow cell, including theoretical and experimental analysis of the mass transfer properties of the nutrient and drug flows, which are in good agreement with one another. To demonstrate proof of concept, the flow cell was mounted on a dummy CMOS chip, which had been plated with HL-1 cardiomyocytes. A test chemical compound was delivered to the cell culture in a spatially resolved manner. Envisioned applications of this stand-alone system include simultaneous toxicological testing of multiple compounds and chemical stimulation of natural neural networks for neuroscience investigations.  相似文献   

8.
Song W  Psaltis D 《Lab on a chip》2011,11(14):2397-2402
We presented a pneumatically tunable 2 × 2 optofluidic switch for on-chip light routing that was controlled by compressed air. The device was fabricated with an optically clear elastomer-polydimethylsiloxane (PDMS)-by soft-lithography. The optical switching is realized with a tunable air-gap mirror by which the light is deflected due to total internal reflection in the bypass state. When the device is subjected to high pressure, the air gap collapses and hence the light will be switched to the crossover state. The device had a switching speed of more than 5 Hz and an extinction ratio of 8 dB. This switch can be readily integrated with other microfluidic circuits. We demonstrated a simple reconfigurable optical waveguide circuit for dual-channel microfluidic spectroscopy measurement on a chip.  相似文献   

9.
A microfluidic assembly method based on a microfluidic chip and capillary device was developed to create multicompartmental particles. The microfluidic chip design endows the particles with regulable internal structure. By adjusting the microstructure of the chip, the diameter of the capillary, the gap length between the two microfluidic components, and the flow rates, the size of the particles and the number or the ratio of different regions within the particle could be widely varied. As a proof of concept, we have produced some complicated particles that even contain 20 compartments. Furthermore, the potential applications of the anisotropic particles are explored by encapsulating magnetic beads, fluorescent nanoparticles, and the cells into different compartments of the microparticles. We believe that this method will open new avenues for the design and application of multicompartmental particles.  相似文献   

10.
微流控芯片操纵传输及实时监测单细胞量子释放   总被引:2,自引:0,他引:2  
微流控芯片技术用于细胞生化分析已引起了广泛关注.Harrison等首次在微流控芯片上对细胞群体进行操纵、传输及反应.yang等在微流控芯片上操纵细胞群体的排列,并用荧光检测细胞群体摄取钙的反应.至今还未见到微流控芯片对单个细胞进行操纵传输、定位及实时监测的报道.单细胞受激释放的监测对探索生物体神经传导具有重要意义.  相似文献   

11.
Wang W  Huang Y  Liu J  Xie Y  Zhao R  Xiong S  Liu G  Chen Y  Ma H 《Lab on a chip》2011,11(5):929-935
A novel integrated continuous-flow microfluidic system was designed and fabricated for solid phase peptide synthesis (SPPS) using conventional reactants. The microfluidic system was composed of a glass-based radial reaction chip, a diffluent chip, amino acid feeding reservoirs and continuous-flow reagent pathways. A tri-row cofferdam-fence structure was designed for solid phase supports trapping. Highly cross-linked, porous and high-loading 4-(hydroxymethyl)phenoxymethyl polystyrene (HMP) beads were prepared for microfluidic SPPS. The transfer losses, hazardous handling and time-consuming processes in traditional peptide cleavage steps were avoided by being replaced with the on-chip cleavage treatment. Six peptides from an antibody affinity peptide library against β-endorphin with different lengths and sequences were obtained simultaneously on the constructed continuous-flow microfluidic system within a short time. This microfluidic system is automatic, integrated, effective, low-cost, recyclable and environment-friendly for not only SPPS but also other solid phase chemical syntheses.  相似文献   

12.
Lee JH  Song YA  Han J 《Lab on a chip》2008,8(4):596-601
In this paper, we report a new method of fabricating a high-throughput protein preconcentrator in poly(dimethylsiloxane) (PDMS) microfluidic chip format. We print a submicron thick ion-selective membrane on the glass substrate by using standard patterning techniques. By simply plasma-bonding a PDMS microfluidic device on top of the printed glass substrate, we can integrate the ion-selective membrane into the device and rapidly prototype a PDMS preconcentrator without complicated microfabrication and cumbersome integration processes. The PDMS preconcentrator shows a concentration factor as high as approximately 10(4) in 5 min. This printing method even allows fabricating a parallel array of preconcentrators to increase the concentrated sample volume, which can facilitate an integration of our microfluidic preconcentrator chip as a signal enhancing tool to various detectors such as a mass spectrometer.  相似文献   

13.
We report the first implementation of the fiber based microfluidic Raman spectroscopic detection scheme, which can be scaled down to micrometre dimensions, allowing it to be combined with other microfluidic functional devices. This novel Raman spectroscopic detection scheme, which we termed as Waveguide Confined Raman Spectroscopy (WCRS), is achieved through embedding fibers on-chip in a geometry that confines the Raman excitation and collection region which ensures maximum Raman signal collection. This results in a microfluidic chip with completely alignment-free Raman spectroscopic detection scheme, which does not give any background from the substrate of the chip. These features allow a WCRS based microfluidic chip to be fabricated in polydimethylsiloxane (PDMS) which is a relatively cheap material but has inherent Raman signatures in fingerprint region. The effects of length, collection angle, and fiber core size on the collection efficiency and fluorescence background of WCRS were investigated. The ability of the device to predict the concentration was studied using urea as a model analyte. A major advantage of WCRS is its scalability that allows it to be combined with many existing microfluidic functional devices. The applicability of WCRS is demonstrated through two microfluidic applications: reaction monitoring in a microreactor and detection of analyte in a microdroplet based microfluidic system. The WCRS approach may lead to wider use of Raman spectroscopy based detection in microfluidics, and the development of portable, alignment-free microfluidic devices.  相似文献   

14.
We describe and characterize a pumping mechanism that leverages the momentum present in small droplets ejected from a micro-nozzle to drive flow in an open microfluidic device. This approach allows driving flow in a microfluidic device in a regime that offers unique features different to those achievable with typical passive pumping or syringe-pump driven flow. Two flow regimes with specific flow characteristics are described: inertia enhanced passive pumping, in which fluid exchange times in the channel are significantly reduced, and inertia actuated flow, in which it is possible to initiate flow in an empty channel or against natural pressure gradients. Momentum is leveraged to create rapid fluid exchanges, instantaneous flow reversal, filling and mixing inside the microfluidic device.  相似文献   

15.
There is a substantial need for simultaneous analyses of RNA and DNA from individual single cells. Such analysis provides unique evidence of cell‐to‐cell differences and the correlation between gene expression and genomic mutation in highly heterogeneous cell populations. We present a novel microfluidic system that leverages isotachophoresis to fractionate and isolate cytoplasmic RNA and genomic DNA (gDNA) from single cells. The system uniquely enables independent, sequence‐specific analyses of these critical markers. Our system uses a microfluidic chip with a simple geometry and four end‐channel electrodes, and completes the entire process in <5 min, including lysis, purification, fractionation, and delivery to DNA and RNA output reservoirs, each containing high quality and purity aliquots with no measurable cross‐contamination of cytoplasmic RNA versus gDNA. We demonstrate our system with simultaneous, sequence‐specific quantitation using off‐chip RT‐qPCR and qPCR for simultaneous cytoplasmic RNA and gDNA analyses, respectively.  相似文献   

16.
This paper presents an innovative driving method for an on-chip robot actuated by permanent magnets in a microfluidic chip. A piezoelectric ceramic is applied to induce ultrasonic vibration to the microfluidic chip and the high-frequency vibration reduces the effective friction on the MMT significantly. As a result, we achieved 1.1 micrometre positioning accuracy of the microrobot, which is 100 times higher accuracy than without vibration. The response speed is also improved and the microrobot can be actuated with a speed of 5.5 mm s(-1) in 3 degrees of freedom. The novelty of the ultrasonic vibration appears in the output force as well. Contrary to the reduction of friction on the microrobot, the output force increased twice as much by the ultrasonic vibration. Using this high accuracy, high speed, and high power microrobot, swine oocyte manipulations are presented in a microfluidic chip.  相似文献   

17.
Song W  Yang J 《Lab on a chip》2012,12(7):1251-1254
We present a novel optofluidic differential method for carrying out absorbance spectroscopy of sub-nanolitre volumes of liquid samples on a microfluidic chip. Due to the reduction of liquid volume, the absorbance detection in microfluidics is often hindered by either low sensitivity or complex fabrication. To address this issue, we introduced an optofluidic modulator which can be easily integrated into a PDMS (polydimethylsiloxane) based microfluidic chip. The modulator was controlled by the fluid pressure and the absorbance spectrum of the analyte was obtained by taking differential measurements between the analyte and reference medium. An advantage is that this method doesn't need a complicated fabrication step. It is compatible with conventional microfluidic chips and measurements can be carried out on a normal transmission microscope. The performance of the device was tested by measuring solutions containing methylene blue, with concentrations as low as 13 μM.  相似文献   

18.
Digital microfluidics using soft lithography   总被引:2,自引:0,他引:2  
Although microfluidic chips have demonstrated basic functionality for single applications, performing varied and complex experiments on a single device is still technically challenging. While many groups have implemented control software to drive the pumps, valves, and electrodes used to manipulate fluids in microfluidic devices, a new level of programmability is needed for end users to orchestrate their own unique experiments on a given device. This paper presents an approach for programmable and scalable control of discrete fluid samples in a polydimethylsiloxane (PDMS) microfluidic system using multiphase flows. An immiscible fluid phase is utilized to separate aqueous samples from one another, and a novel "microfluidic latch" is used to precisely align a sample after it has been transported a long distance through the flow channels. To demonstrate the scalability of the approach, this paper introduces a "general-purpose" microfluidic chip containing a rotary mixer and addressable storage cells. The system is general purpose in that all operations on the chip operate in terms of unit-sized aqueous samples; using the underlying mechanisms for sample transport and storage, additional sensors and actuators can be integrated in a scalable manner. A novel high-level software library allows users to specify experiments in terms of variables (i.e., fluids) and operations (i.e., mixes) without the need for detailed knowledge about the underlying device architecture. This research represents a first step to provide a programmable interface to the microfluidic realm, with the aim of enabling a new level of scalability and flexibility for lab-on-a-chip experiments.  相似文献   

19.
Szekely L  Freitag R 《Electrophoresis》2005,26(10):1928-1939
In this paper, we investigate the phenomenon of electroosmosis as a means to propel a mobile phase, in particular in view of an application in microfluidic systems, which are characterized by significantly smaller volumes of the reservoirs and the separation channels compared to conventional instrumentation. In the microfluidic chip, pH changes due to water electrolysis quickly showed an effect on the electroosmotic flow (EOF), which could be counteracted by either regularly exchanging or buffering the mobile phase. Surface treatment was of no effect in regard to EOF stabilization in empty channels but may have an influence in channels filled with a charged monolith. In fused-silica capillaries the EOF was generally found to decrease from 'naked' to surface-treated to monolith-filled capillaries. The EOF tended to be higher when an organic solvent (acetonitrile) was added to the mobile phase and could be further increased by substituting the water with equal amounts of methanol. In addition, the hydrostatic pressure exerted by the EOF was investigated. In a microfluidic chip with empty (cross-)channels such an effect could be responsible for a redirection of the flow. In capillaries partially filled with a noncharged (non-EOF-generating) monolith, a linear relationship could be established between the EOF created in the empty section of the capillary (apparent mobility) and the length of the monolith (backpressure). In capillaries partially filled with a charged (EOF-producing) monolith, flow inhomogeneities must be expected as a consequence of a superimposition of hydrodynamic pressure and EOF as mobile phase driving force.  相似文献   

20.
We have developed a microfluidic device operating at a planar surface instead of a closed channel network. The fluid is transported in single droplets using surface acoustic waves (SAW) on a piezoelectric LiNbO(3) substrate. The surface of the piezo is chemically structured to induce high contact angles of the droplets or enclose areas where the liquid can wet the substrate. Combining the SAW technique with thin film resistance heaters, a biological analysis chip with integrated DNA amplification by PCR and hybridization was designed. To prevent evaporation of the PCR reagents at high temperatures the sample is enclosed in droplets of mineral oil. On this chip the SAW resolves dried primers, shifts the oil capped liquid between the two heaters and mixes during hybridization. The chip is able to perform a highly sensitive, fast and specific PCR with a volume as low as 200 nl. During the temperature cycles an online monitoring of the DNA concentration is feasible with an optical unit, providing a sensitivity of 0.1 ng. After PCR the product is moved to the second heater for the hybridization on a spotted DNA array. With our chip we were able to detect a single nucleotide polymorphism (SNP) responsible for the Leiden Factor V syndrome from human blood.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号