首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 156 毫秒
1.
A flow-injection chemiluminescence (CL) method for the determination of melatonin based on the CL reaction of melatonin with hydrogen peroxide and sodium hypochlorite (NaOCl) in a basic alkaline solution was developed. The possible CL mechanism has been discussed, and a proposal for the reaction pathway was given that singlet oxygen was clarified to be produced in this reaction system and was responsible for the CL emission. Under the optimized conditions, the linear concentration range of application was 1.0×10^-7-2.5 × 10^-4 moloL-I with a de- tection limit of 5.0 ×10^-8 moloL-1 (S/N= 3). The relative standard deviation for eight repeated measurements of 1.0×10^-6 mol·L^-1 melatonin was 2.8%. The interferences of several important biological substances, some indole compound, cations and anions were studied. No interference was found for the anions, glucose, starch, most of cations and low concentration (less than 3.0 × 10^-6 mol·L^-1) of some biological substances and indole compound. The method was applied to the determination of melatonin in rat pineal gland and drug with satisfactory results. The sample throughput was 90 injections per hour.  相似文献   

2.
A novel method for the determination of two quinolone drugs norfloxacin (NOR) and levofloxacin (LVX) was described by capillary electrophoresis with electrochemiluminescence detection. The good relationship (r ≥ 0.9991) between peak area and concentration of analytes was established over two orders of magnitude. The limits of detection (LOD, S/N = 3) in standard solution are 4.8 × 10^-7 mol/L for NOR and 6.4 × 10^-7 mol/L for LVX, respectively. The limits of quantitation (LOQ, S/N = 10) in real human urine samples are 1.2 × 10^-6 mol/L for NOR and 1.4 × 10^-6 mol/L for LVX, respectively. The present method was successfully applied to the determination of NOR and LVX in human urine and the studv of oharmacokinetics of NOR.  相似文献   

3.
Potassium dehydroandrographolide succinate (DAS-K) has antibacterial and antiviral effects. It has been used widely for the treatment of virus pneumonia, malaria and respiratory infections. In this work, a novel flow-injection chemiluminescence (CL) method for the determination of DAS-K was proposed. The method is based on the reaction between DAS-K and hexacyanoferrate(III) in alkaline solution to give weak CL signal, which is enhanced by rhodamine B. The experimental conditions for the CL reaction were optimized and the possible reaction mechanism was discussed. Under the optimum conditions, the concentration of DAS-K is proportional to the CL intensity in the range of 0.1-80 μmol·L^-1 with a detection limit of 0.05 μmol·L^-1. The interaction of the DAS-K with bovine serum albumin by on-line ultrafiltration and flow-injection chemiluminescence was studied. The concentrations of unbound DAS-K from ultra filter tube were determined by the flow-injection CL method. The binding parameters were estimated by the Scatchard plot and Klotz plot. The proposed system proved that FIA-CL coupled with on-line ultrafiltration sampling was a fast and simple technique for the study of drug-protein interaction.  相似文献   

4.
A cobalt hexacyanoferrate (CoHCF) nanoparticle (size ca. 60 nm) chemically modified electrode (CME) was fabricated and the electrochemical behavior of hemoglobin (Hb) at this nanosized CoHCF CME was studied. In comparison with a bare glassy carbon electrode (GCE) and a general CoHCF CME electrodeposited in a traditional manner, the present nanosized CoHCF CME performed efficiently electrocatalytic reduction for Hb with relatively high sensitivity, stability, and longlife, Combined with liquid chromatography (LC), the nanosized CoHCF CME was used as the electrochemical detector of Hb in the established flow injection analysis-electrochemical determination (FIA-ECD) system. The peak current was a linear function of concentrations in the range from 2.5×10^-8 to 5.0×10^-6mol/L for Hb, with detection limit of 1.4×10^-8 mol/L. The FIA-ECD system has been successfully applied to assess the Hb content of clinic blood samples with advantages of sensitiveness, speediness, easy control and small sample-consumption.  相似文献   

5.
A simple and sensitive spectroelectrochemistry method for the determination of vitamin K 3 was developed by combining electrolysis and fluoremetry. This method was based on that vitamin K 3 was reduced at a glassy carbon electrode, and its product with characteristic fluorescence at 420 nm was determined with excitation wavelength at 309 nm. Under optimized electrochemical reaction conditions and fluorescent experiment parameters, the fluores-cence intensity was proportional to the concentration of vitamin K 3 in a range from 3.50×10 ?7 to 1.05×10 ?5 mol/L with a correlation coefficient of 0.9991, and detection limit was estimated to be 7.50×10 ?8 mol/L at a signal/noise ra-tio of 3. The relative standard deviation was less than 4.3%(n=5) and the recovery was in a range of 97%―105% for the determination of vitamin K 3 in pharmaceutical preparations. The result is satisfactory for the determination of vi-tamin K 3 as comparison to that from HPLC method.  相似文献   

6.
<正>It was found that 20 amino acids could inhibit the intensity of the luminol-H_2O_2-CuSO_4 chemiluminescence system.Using this character,a rapid and sensitive method for the determination of 20 amino acids was developed with flow injection coupled with chemiluminescence detection.Under the optimal conditions,the detection limits of 20 amino acids were in the range of 4.5×10~(-7)- 4.3×10~(-10) mol/L,and the relative standard deviations were less than 3.2%.The proposed method was successfully applied to drug analysis.The possible mechanism was also discussed.  相似文献   

7.
A novel type of carboxylated multiwalled carbon nanotube modified electrode(c-MWCNTs/GCE) was constructed and the electrochemical properties of phenacetin(PHE) at it were studied. In a buffer solution of 0.1 mol/L HAc-NaAc(pH=5.3), PHE exhibited a couple of quasi-reversible redox peaks and an anodic peak in the poten- tial range of 0.2--1.2 V at c-MWCNTs/GCE. The peak current was proportional to the concentration of PHE in the range of 4.0× 10^-6_ 1.0 × 10^-4 mol/L with a detection limit of 1.0× 10^-6 mol/L(S/N=3). The c-MWCNTs/GCE showed excellent repeatability and stability and the electrochemical reaction mechanism of PHE was proposed. This method was used to determine the content of PHE in medical tablets and the recovery was determined to be 96.5%--104.2% by means of a standard addition method.  相似文献   

8.
The electrochemiluminescence (ECL) of luminol in aqueous alkaline solution was studied.Trace amounts of chloride showed significant effect on the efficiency of light emission of luminol as a posi-tive trigonometrical wave pulse was exerted on the solution. The detection limit for the chloride is5.0 ×10~(-6) mol/L and the linear calibration range extends up to 1.0 ×10~(-2) mol/L; the relative standarddeviation for 1.0 ×10~(-5) mol / L chloride is 5%. The influencing factors for chloride determination arealso discussed. The possible mechanism for the electrochemiluminescence reaction may be due to theoxidation of chloride ion in the solution to ClO~-, and the latter acts on luminol and then gives outluminescence. The method has been applied to determine the total chloride in tap water with satisfactoryresults.  相似文献   

9.
A novel kinetic method for determination of trace amounts of cobalt ion was proposed and validated. The method is based on adding malic acid into classical Belousov-Zhabotinskii (B-Z) oscillating chemical system to form a double substrate one. The results showed that when the concentration of cobalt ion was in the range of 5.27× 10^-8 to 5.37 × 10^-12 mol L^-1, the change of the oscillating period was directly proportional to the negative logarithm of cobalt ion concentration. The sensitivity and precision of the developed method were quite satisfactory. The limit of detection was down to 5.20 × 10^-13 mol L^-1 which was a highest sensitivity found for determination of metal ions using oscillating chemical reaction so far. Some factors influencing the determination were also examined. The method has been successfully used to determine cobalt ion in vitamin B12 injection.  相似文献   

10.
A fluorescence enhancement phenomenon on adding terbium to the Eu or Sm-DBM-CTMAB-Triton X-100 fluorescence system was observed. The fluorescence intensity of this system was 50 times greater than that of the system without terbium at pH 9.0. The fluorescence intensity is a linear function of the concentration of europium or samarium in the range of 1.0×10~(-10)-8.0×10~(-6) mol/L and 1.0×10~(-7)-8.0×10~(-6) mol/L, respectively. The deteetion limits for them were 1.0×10~(-12) mol/L and 1.0×10~(-9) mol/L, respectively. This system was used for the determination of europium or samarium in rare earth samples with satisfactory results.  相似文献   

11.
A novel flow injection chemiluminescence (FI‐CL) method for the determination of genistein was described. The method was based on the reaction between genistein and potassium ferricyanide in alkaline solution to give weak CL signal, which was dramatically enhanced by rhodamine 6G (Rh G). The CL emission allowed quantitation of genistein concentration in the range 1.0 × 10?7–4.0 × 10?5 mol/L with a detection limit (3σ) of 4.2 × 10?8 mol/L. The relative standard deviation for 11 parallel measurements of 5.0 × 10?7 mol/L, 4.0 × 10?6 mol/L and 1.0 × 10?5 mol/L genistein were 2.59%, 2.40% and 1.48%, respectively. The experimental conditions for the CL reaction were optimized and the possible reaction mechanism was discussed. The method was applied to the determination of genistein in biological fluids.  相似文献   

12.
The chemiluminescence (CL) detection for the determination of sulfite using the reaction of Ru(bipy)3 2+(bipy=2,2′-bipyridyl)-SO3 2–-KIO4 is described. The concentration of sulfite is proportional to the CL intensity from 1.0 × 10–7 to 1.0 × 10–4 mol/L. The limit of detection is 2.0 × 10–8 mol/L and the relative standard deviation is 4.4% for a 2 × 10–5 mol/L sulfite solution (n = 9). This method has successfully been applied to the determination of sulfite in powdered sugar (sucrose) and of sulfur dioxide in air by using triethanolamine (TEA) as absorbent material.  相似文献   

13.
张四纯  周国俊  鞠熀先 《中国化学》2002,20(10):1049-1054
IntroductionGallicacidexistsintheleavesandfruitsofmanytypesofplantsandiswidelyusedinmedicineforanti oxi dationandantibacterialactivity ,antiflammatoryactionandanti canceractivity .1 5Inspiteofthehealthimportanceofgallicacid ,itsmetabolismandkineticsinthehu…  相似文献   

14.
A novel chemiluminescence (CL) system was established for the determination of puerarin in pharmaceutical preparations. It was shown that a strong CL signal was observed when Eosin Y reacted with the hydroxyl radicals which were generated from Fenton reagent in acidic medium. The CL intensity was decreased significantly when puerarin was added to the reaction system and partially scavenged the hydroxyl radicals in the solution. The extent of decrease in the CL intensity had a good stoichiometrical relationship with puerarin concentration. Based on this, a new method for the determination of puerarin using a flow injection chemiluminescence technique was developed. The experimental parameters that affected the CL intensity were optimized. Under the optimal conditions, the linear range for puerarin concentration was 8.0×10?8?2.0×10?6 mol/L (R=0.9982) with a detection limit of 7.5×10?9 mol/L (S/N=3) and the relative standard deviation was 1.7% for 4.0×10?7 mol/L puerarin (n=11). The proposed method was applied to the determination of puerarin in a puerarin injection with satisfactory results.  相似文献   

15.
《Analytical letters》2012,45(14):2026-2036
A novel chemiluminescence (CL) system was established for the determination of diammonium glycyrrhizinate (DG) in pharmaceutical preparations and its ability of scavenging hydroxyl radical. It was shown that a strong CL signal was observed when Eosin Y mixed with Fenton reagent. The CL intensity was decreased significantly when DG was added to the reaction system and partially scavenged the hydroxyl radicals in the solution. The extent of decrease in the CL intensity had a good stoichiometrical relationship with DG concentration. Based on this, we developed a new method for the determination of DG using a flow injection chemiluminescence (FI-CL) technique. Under the optimal conditions, the linear range of DG concentration was 6.0 × 10?8–5.0 × 10?6 mol/L (R = 0.9982) with a detection limit of 8.0 × 10?9 mol/L (SN = 3), and the RSD was 3.8% for 2.0 × 10?7 mol/L DG (n = 11). This method was successfully used in the determination of DG in tablets and the evaluation of hydroxyl radical scavenging capacity of DG. The possible reaction mechanism of the CL system is discussed.  相似文献   

16.
《Analytical letters》2012,45(12):2475-2481
Abstract

A new chemiluminescence (CL) reaction was observed when cloperastine hydrochloride was injected into the reaction mixture after the CL reaction of Ce(IV) and sodium sulfite finished. A new flow injection CL method for the determination of cloperastine hydrochloride was established based on the CL reaction. The relative standard deviation (RSD) for the determination of cloperastine hydrochloride was 1.3% (n=11, c=1.0×10?6 g/mL). The CL intensity responded linearly to the concentration of cloperastine hydrochloride in the range 2.0×10?7~2.0×10?5 g/mL (r=0.9962). The detection limit was 5×10?8 g/mL cloperastine hydrochloride. The method had been applied to the determination of cloperastine hydrochloride in tablets with satisfactory results.  相似文献   

17.
Abstract

The emission produced by sulfite after oxidation by potassium permanganate in acidic solution in the presence of Ru(phen)3 2+ is used to determine 1.0 × 10?7 to 2.5 × 10?5 mol/L sulfite. The limit of detection is 4.5 × 10?9 mol/L and the relative standard deviation is 3.1% for a 1 × 10?5 mol/L sulfite solution (n=8). The method was also applied satisfactorily to the determination of sulfur dioxide in air by using triethanolamine (TEA) as absorbent material.  相似文献   

18.
《Analytical letters》2012,45(15):3285-3302
ABSTRACT

A sensitive chemiluminescence (CL) induced by light for the determination of riboflavin with flow injection analysis is developed. Riboflavin shows a strong enhancement effect on the CL reaction of luminol oxidized by periodate after the photochemical reaction of riboflavin in alkaline solution, and the enhancing effect of riboflavin disappears under dark conditions. Oxygen can further improve the enhancing effect of the riboflavin in this CL system, and the effects were also investigated. And based on this phenomenon, a very sensitive method of various surfactants, β-cyclodextrin and organic solvents on this CL system for the determination of riboflavin was described. The range of the linear response for riboflavin using this method is ca. 2.4×10?8 ~ 1.0 × 10?6 mol/L, and the detection limit (S/N = 3) is l.0×10?8 mol/L. The applicability of the method was demonstrated by the determination of riboflavin in pharmaceutical preparation.  相似文献   

19.
《Analytical letters》2012,45(17):3124-3137
Abstract

A terbium-sensitized fluorescence spectrophotometry method using an anionic surfactant, sodium dodecyl benzene sulphonate (SDBS), was developed for the determination of prulifloxacin (PUFX). It was found that SDBS significantly enhanced the fluorescence intensity of the PUFX–Tb3+ complex (about 13-fold). The optimal experimental conditions were determined as follows: excitation and emission wavelengths of 290 nm and 545 nm, pH 8.0, 4.0 × 10?5 mol L?1 terbium(III), and 4.0 × 10?4 mol L?1 SDBS. The enhanced fluorescence intensity of the system (ΔF) showed a good linear relationship with the concentration of PUFX over the range 6.0 × 10?8 to 2.0 × 10?6mol L?1 with a correlation coefficient of 0.9991. The detection limit (S/N = 3) was determined as 8.5 × 10?9 mol L?1. This method has been successfully applied for the determination of PUFX in pharmaceuticals and human urine/serum samples. Compared with most other methods reported, the rapid and simple procedure proposed here offered higher sensitivity, wider linear range, and good stability. The luminescence mechanism of the system was also discussed in detail. In the fluorescence system of PUFX–Tb3+–SDBS, SDBS acted not only as the surfactant but also as the energy donor.  相似文献   

20.
《Analytical letters》2012,45(4):626-636
A new chemiluminescence system of Tb3+/K2S2O8 was developed for the determination of albumin. Some experimental conditions were examined and optimized. The linear ranges of the calibration curves are 5.0 × 10?9–5.0 × 10?6 mol/L for bovine serum albumin, 5.0 × 10?8–1.0 × 10?5 mol/L for human serum albumin and 2.5 × 10?7–1.0 × 10?5 mol/L for ovalbumin, and the corresponding detection limits are 1.9 × 10?9 mol/L, 1.5 × 10?8 mol/L, and 1.5 × 10?7 mol/L, respectively. The method was applied to the determination of albumin in human serum samples, and the results were in agreement with those obtained by the bromcresol green method. The relative errors for the analytical results were from ?2.0% to 4.3%.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号