首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 687 毫秒
1.
A supramolecular solvent made up of vesicles of decanoic acid in the nano- and microscale regimes dispersed in a continuous aqueous phase is proposed for the extraction/preconcentration of benzimidazolic fungicides (BFs) from river and underground water samples prior to their determination by liquid chromatography (LC)/fluorimetry. The solvent is produced from the coacervation of decanoic acid aqueous vesicles by the action of tetrabutylammonium (Bu4N+). Carbendazim (CB), thiabendazole (TB) and fuberidazole (FB) are extracted on the basis of hydrophobic and π-cation interactions and the formation of hydrogen bonds. The extraction provides high preconcentration factors (160 for CB and 190 for TB and FB), requires a short time (the procedure takes less than 20 min and several samples can be simultaneously processed) and a low sample volume (20 mL), and avoids the use of toxic organic solvents. Because of the absence of matrix interferences and the low viscosity of the extracts, these can be directly injected into the chromatographic system without the need of cleaning-up or diluting them. Recoveries are not influenced by the presence of salt concentrations up to 1 M. The proposed method provides detection limits for the determination of CB, TB and FB in natural waters of 32, 4 and 0.1 ng L−1, respectively, and a precision, expressed as relative standard deviation (n = 11) of 5.5% for CB (100 ng L−1), 4.0% for TB (80 ng L−1) and 2.5% for FB (30 ng L−1). Recoveries obtained by applying this approach to the analysis of river and underground water samples fortified at the ng L−1 level are in the intervals 75–83, 95–102 and 97–101% for CB, TB and FB, respectively.  相似文献   

2.
Orthogonal array design (OAD) was utilized for the first time to optimize the experimental conditions of ultrasound-assisted emulsification–microextraction (USAEME) for determining chlorinated phenoxyacetic acids (CPAs) in river water samples. The use of ultrasound facilitates the mass transfer of CPAs from an aqueous phase into a water-immiscible organic extraction solvent (dichloromethane, DCM) without adding dispersive solvent to form numerous microdroplets. The water-immiscible extractant was collected by centrifugation, dried under low pressure, reconstituted in methanol–water mixture (1:1), and injected into a HPLC system for the determination of CPAs. The linear range was 2–1000 ng mL−1 (2, 5, 10, 50, 200, 500 and 1000 ng mL−1) for each analyte and the relative standard deviations of CPAs among the seven different concentrations were in the range of 1.5–17.0% (n = 3). The detection limits (signal-to-noise ratio of 3) of CPAs ranged from 0.67 to 1.50 ng mL−1. The ranges of intra-day precision (n = 3) for CPAs at the levels of 5 and 200 ng mL−1 were 3.6–11.9% and 5.3–9.5%, respectively. The range of inter-day precision (n = 3) at 5 and 200 ng mL−1 were 1.4–7.7% and 8.5–12.2%, respectively. The applicability of USAEME for environmental analysis was demonstrated by determining CPAs in river water. The recoveries of CPAs from five-spiked river water samples at 10 and 200 ng mL−1 were 96.3–112.5% and 94.8–109.4%, respectively. The maximum contaminant level (MCL) of 2,4-D in drinking water and the tolerance of residues in food for p-CPA are 70 and 200 μg L−1, respectively, according to the US EPA regulations. These contaminant levels fall in the linear range investigated in this study. In addition, this USAEME method provided detection limits lower than their contaminant levels, which made USAEME an effective sample preparation method for determining organic environmental contaminants, such as CPAs, in river water samples with little consumption of organic solvent.  相似文献   

3.
An extraction and preconcentration procedure for the determination in water samples of several halogenated flame retardants (FRs), nine brominated diphenyls ethers (BDEs) and seven non-BDE FRs, was developed and validated. The optimised procedure is based on polydimethylsiloxane (PDMS) rods as sorptive extraction material, followed by liquid desorption and gas chromatography coupled to negative chemical ionisation–mass spectrometry (GC–NCI–MS) determination, rendering an efficient and inexpensive method. The final optimised protocol consists of overnight extraction of 100 mL of sample solutions containing 40% MeOH and 4% NaCl, followed by a 15-min sonication-assisted desorption with 300 μL of ethyl acetate, solvent evaporation and GC–NCI–MS analysis. Under these conditions, extraction efficiencies in the 9 to 70% range were obtained, leading to enrichment factors between 108 and 840, detection limits in the range from 0.4 to 10 ng L−1and RSD values in the 2–23% range. After method validation, different real water samples, including river, ria, sea, landfill leachate, influent and effluent wastewater from an urban sewage treatment plant (STP) and effluent wastewater from a textile industry, were analysed. BDE-47, BDE-99, BDE-100 and BDE-197 were detected in wastewater and landfill leachate samples at concentration levels up to 2887 ng L−1. Among the non-BDE FRs, bis (2-ethylhexyl)-3,4,5,6-tetrabromo-phthalate (DEHTBP) was detected in surface water samples (sea, river and ria) between 1.3 and 2.2 ng L−1 and 1,2-bis(2,4,6-tribromophenoxy)ethane (BTBPE) in the landfill leachate (64 ng L−1).  相似文献   

4.
Coacervative microextraction ultrasound-assisted back-extraction technique (CME-UABE) is proposed for the first time for extracting and preconcentrating organophosphates pesticides (OPPs) from honey samples prior to gas chromatography–mass spectrometry (GC–MS) analysis. The extraction/preconcentration technique is supported on the micellar organized medium based on non-ionic surfactant. To enable coupling the proposed technique with GC, it was required to back extract the analytes into hexane. Several variables including, surfactant type and concentration, equilibration temperature and time, matrix modifiers, pH and buffers nature were studied and optimized over the relative response of the analytes. The best working conditions were as follows: an aliquot of 10 mL 50 g L−1 honey blend solution was conditioned by adding 100 μL 0.1 mol L−1 hydrochloric acid (pH 2) and finally extracted with 100 μL Triton X-114 100 g L−1 at 85 °C for 5 min using CME technique. Under optimal experimental conditions, the enrichment factor (EF) was 167 and limits of detection (LODs), calculated as three times the signal-to-noise ratio (S/N = 3), ranged between 0.03 and 0.47 ng g−1. The method precision was evaluated over five replicates at 1 ng g−1 with RSDs ≤9.5%. The calibration graphs were linear within the concentration range of 0.3–1000 ng g−1 for chlorpirifos; and 1–1000 ng g−1 for fenitrothion, parathion and methidathion, respectively. The coefficients of correlation were ≥0.9992. Validation of the methodology was performed by standard addition method at two concentration levels (2 and 20 ng g−1). The recoveries were ≥90%, indicating satisfactory robustness of the methodology, which could be successfully applied for determination of OPPs in honey samples of different Argentinean regions. Two of the analyzed samples showed levels of methidathion ranged between 1.2 and 2.3 ng g−1.  相似文献   

5.
Elci L  Kolbe N  Elci SG  Anderson JT 《Talanta》2011,85(1):551-555
Solid-phase extraction (SPE) followed by derivatization and gas chromatography-atomic emission detection (GC-AED) was evaluated for the determination of five chlorophenols (CPs) in water samples. The derivatization was based on the esterification of phenolic compounds with ferrocenecarboxylic acid. The determination of the derivatized phenols was performed by GC-AED in the iron selective detection mode at 302 nm. The described method was tested on spiked water samples.The overall method gave detection limits of 1.6-3.7 ng L−1 and recoveries of 90.9-104.5% for the examined mono- to trichlorophenols in 10 mL water samples. The CPs extracted from a 10 mL water sample with SPE were concentrated into 100 μL of organic solvent, a preconcentration factor of 100. The method was applied to lake and tap water samples, and CP contents between 6 and 51 ng L−1 in lake water and between below the detection limit and 8 ng L−1 in tap water were found for different CPs. The method is quick, simple and gives excellent recoveries, limits of detection and standard deviations.  相似文献   

6.
Based on the highly sensitive fluorescence change of water-soluble CdSe/ZnS core-shell quantum dots (QD) by paraquat herbicide, a simple, rapid and reproducible methodology was developed to selectively determine paraquat (PQ) in water samples. The methodology enabled the use of simple pretreatment procedure based on the simple water solubilization of CdSe/ZnS QDs with hydrophilic heterobifunctional thiol ligands, such as 3-mercaptopropionic acid (3-MPA), using microwave irradiation. The resulting water-soluble QDs exhibit a strong fluorescence emission at 596 nm with a high and reproducible photostability. The proposed analytical method thus satisfies the need for a simple, sensible and rapid methodology to determine residues of paraquat in water samples, as required by the increasingly strict regulations for health protection introduced in recent years. The sensitivity of the method, expressed as detection limits, was as low as 3.0 ng L−1. The lineal range was between 10–5 × 103 ng L−1. RSD values in the range of 71–102% were obtained. The analytical applicability of proposed method was demonstrated by analyzing water samples from different procedence.  相似文献   

7.
This paper presents the development, optimization and validation of a LC–MS/MS methodology to determine the antiparasitic veterinary drug toltrazuril and its two main metabolites, toltrazuril sulfoxide and toltrazuril sulfone, in environmental surface water, soil and animal manure. Using solid phase extraction and selective pressurized liquid extraction with integrated clean-up, the analytical method allows for the determination of these compounds down to 0.06–0.13 ng L−1 in water, 0.01–0.03 ng g−1 dw in soil and 0.22–0.51 ng g−1 dw in manure. The deuterated analog of toltrazuril was used as internal standard, and ensured method accuracy in the range 96–123% for water and 77–110% for soil samples. The developed method can also be applied to simultaneously determine steroid hormones in the solid samples. The antiparasitic drug and its metabolites were found in manure and soil up to 114 and 335 pg g−1 dw, respectively. Little is known regarding the environmental fate and effects of these compounds; consequently more research is urgently needed.  相似文献   

8.
Three preconcentration techniques including solid phase extraction (SPE), dispersive liquid-liquid microextraction (DLLME) and stir-bar sorptive extraction (SBSE) have been optimized and compared for the analysis of six hypolipidaemic statin drugs (atorvastatin, fluvastatin, lovastatin, pravastatin, rosuvastatin and simvastatin) in wastewater and river water samples by high performance liquid chromatography coupled to quadrupole-time-of-flight mass spectrometry (HPLC/Q-TOF-MS). Parameters that affect the efficiency of the different extraction methods such as solid phase material, sample pH and elution solvent in the case of SPE; the type and volume of the extracting and dispersive solvent, pH of sample, salt addition and number of extraction steps in the case of DLLME; and the stirring time, pH of sample, sample volume and salt addition for SBSE were evaluated. SPE allowed the best recoveries for most of the analytes. Pravastatin was poorly extracted by DLLME and could not be determined. SBSE was only applicable for lovastatin and simvastatin. However, despite the limitations of having poorer recovery than SPE, DLLME and SBSE offered some advantages because they are simple, require low organic solvent volumes and present low matrix effects. DLLME required less time of analysis, and for SBSE the stir-bar was re-usable. SPE, DLLME and SBSE provided method detection limits in the range of 0.04-11.2 ng L−1, 0.10-17.0 ng L−1 for 0.52-2.00 ng L−1, respectively, in real samples. To investigate and compare their applicability, SPE, DLLME and SBSE procedures were applied to the detection of statin drugs in effluent wastewater and river samples.  相似文献   

9.
A rapid and sensitive method for the determination of carbendazim (methyl benzimidazole-2-ylcarbamate, MBC) and thiabendazole (TBZ) in water and soil samples was developed by using dispersive liquid-liquid microextraction (DLLME) coupled with high performance liquid chromatography with fluorescence detection. The water samples were directly used for the DLLME extraction. For soil samples, the target analytes were first extracted by 0.1 mol L−1 HCl. Then, the pH of the extract was adjusted to 7.0 with 2 mol L−1 NaOH before the DLLME extraction. In the DLLME extraction method, chloroform (CHCl3) was used as extraction solvent and tetrahydrofuran (THF) as dispersive solvent. Under the optimum conditions, the enrichment factors for MBC and TBZ were ranged between 149 and 210, and the extraction recoveries were between 50.8 and 70.9%, respectively. The linearity of the method was obtained in the range of 5-800 ng mL−1 for water sample analysis, and 10-1000 ng g−1 for soil samples, respectively. The correlation coefficients (r) ranged from 0.9987 to 0.9997. The limits of detection were 0.5-1.0 ng mL−1 for water samples, and 1.0-1.6 ng g−1 for soil samples. The relative standard deviations (RSDs) varied from 3.5 to 6.8% (n = 5). The recoveries of the method for MBC and TBZ from water samples at spiking levels of 5 and 20 ng mL−1 were 84.0-94.0% and 86.0-92.5%, respectively. The recoveries for soil samples at spiking levels of 10 and 100 ng g−1 varied between 82.0 and 93.4%.  相似文献   

10.
A novel ultrasound-assisted surfactant-enhanced emulsification microextraction (UASEME) coupled with high performance liquid chromatography-diode array detection has been developed for the extraction and determination of six carbamate pesticides (metolcarb, carbofuran, carbaryl, pirimicarb, isoprocarb and diethofencarb) in water samples. In the UASEME technique, Tween 20 was used as emulsifier, and chlorobenzene and chloroform were used as dual extraction solvent without using any organic dispersive solvent that is normally required in the previously described common dispersive liquid–liquid microextraction method. Parameters that affect the extraction efficiency, such as the kind and volume of the extraction solvent, the type and concentration of the surfactant, ultrasound emulsification time and salt addition, were investigated and optimized for the method. Under the optimum conditions, the enrichment factors were in the range between 170 and 246. The limits of detection of the method were 0.1–0.3 ng mL−1 and the limits of quantification were between 0.3 and 0.9 ng mL−1, depending on the compounds. The linearity of the method was obtained in the range of 0.3–200 ng mL−1 for metolcarb, carbaryl, pirimicarb, and diethofencarb, 0.6–200 ng mL−1 for carbofuran, and 0.9–200 ng mL−1 for isoprocarb, with the correlation coefficients (r) ranging from 0.9982 to 0.9998. The relative standard deviations varied from 3.2 to 4.8% (n = 5). The recoveries of the method for the six carbamates from water samples at spiking levels of 1.0, 10.0, 50.0 and 100.0 ng mL−1 were ranged from 81.0 to 97.5%. The proposed UASEME technique has demonstrated to be simple, practical and environmentally friendly for the determination of carbamates residues in river, reservoir and well water samples.  相似文献   

11.
Liquid chromatography (LC)/tandem mass spectrometry (MS/MS) after supramolecular solvent-based microextraction (SUSME) was firstly used in this work for the enantioselective determination of chiral pesticides in natural waters. The method developed for the quantitation of the R- and S-enantiomers of mecoprop (MCPP) and dichlorprop (DCPP) involved the extraction of the herbicides in a supramolecular solvent (SUPRAS) made up of reverse aggregates of dodecanoic acid (DoA), analyte re-extraction in acetate buffer (pH = 5.0), separation of the target enantiomers on a chiral column of permethylated α-cyclodextrin under isocratic conditions, and detection of the daughter ions (m/z = 140.9 and 160.6 for MCPP and DCPP, respectively) using a hybrid triple quadrupole mass spectrometer equipped with an electrospray source operating in the negative ion mode. Similar recoveries (ca. 75%) and actual concentration factors (ca. 94) were obtained for both phenoxypropanoic acids (PPAs). The quantitation limits were 1 ng L−1 for R- and S-MCPP, and 4 ng L−1 for R- and S-DCPP, and the precision, expressed as relative standard deviation (n = 6) was in the ranges 2.4–2.7% ([R-MCPP] = [S-MCPP] = 5 ng L−1 and [R-DCPP] = [S-DCPP] = 15 ng L−1) and 1.6–1.8% (100 ng L−1 of each enantiomer). The SUSME-LC–MS/MS method was successfully applied to the determination of the enantiomers of MCPP and DCPP in river and underground waters, fortified at concentrations between 15 and 180 ng L−1 at variable enantiomeric ratios (ER = 1–9).  相似文献   

12.
Sensitive and reliable methods have been developed and validated for determination of commonly consumed azole antifungal pharmaceuticals (clotrimazole, econazole, ketoconazole, and miconazole) and biocides (propiconazole and tebuconazole) in various waters and sewage sludge. Solid phase extraction (SPE) combined with ultra-high performance liquid chromatography–tandem mass spectrometry (UHPLC–MS/MS) was used to determine the azole antifungals in waters. Azole antifungals in sewage sludge were extracted with ultrasonic-assisted extraction, followed by SPE cleanup and UHPLC–MS/MS detection. Quantification was performed by internal standard calibration in multiple reaction monitoring mode. Recoveries were mostly in the range of 52–110% with relative standard deviations generally within 20%. Method quantification limits were 0.5–6 ng L−1 in waters and 3–9 ng g−1 dry weight (dw) in sewage sludge, respectively. The methods were applied to determine the azole antifungals in wastewater, river water, sediment, and sewage sludge sampled from the Pearl River Delta, China. Clotrimazole, ketoconazole, and miconazole were widely detected at low ng L−1 in waters, low ng g−1 dw in river sediment, and low μg g−1 dw in sewage sludge. The methods can provide valuable tools for investigating occurrence and fate of the azole antifungals in the environment.  相似文献   

13.
We describe the development of a liquid chromatography with negative-ion atmospheric pressure photoionization tandem mass spectrometric (LC/NI-APPI/MS/MS) method for the simultaneous determination of tetrabromobisphenol A (TBBP-A) and five polybrominated diphenyl ethers (BDE-47, BDE-99, BDE-100, BDE-153 and BDE-154) in water. A mobile phase methanol/acetone/water was used, where acetone acts also as dopant. NI-APPI produced precursor ions corresponding to [M−H] for TBBP-A, [M−Br+O], and [M−2Br+O] for the BDE congeners studied. Each compound was quantified operating in multiple reaction monitoring mode. Linearity was observed in the range 0.025–10 ng injected for all compounds. Coefficients of determination R2 ranged from 0.9934 to 0.9982. BDEs were poorly retained by solid-phase extraction (SPE) from river water and sewage treatment plant effluent, thus liquid–liquid extraction (LLE) by n-hexane should be used for these samples. The recoveries of TBBP-A and PBDEs from tap water (SPE), river water and industrial wastewater (LLE) were in the range of 81–88%, 78–92%, and 43–99%, respectively, with relative standard deviations below 17%. The limits of detection, based on signal-to-noise ratio of 3, ranged from 0.004 to 0.1 ng injected, and method quantification limits were 0.2–3.3 ng L−1 but BDE47 (20.3 ng L−1). Only TBBP-A was found in a treated industrial sewage at 4 ng L−1, while BDE-99 and BDE-100 were detected on suspended solids.  相似文献   

14.
A simple, sensitive and selective method for the simultaneous determination of five ultraviolet (UV) filters: benzophenone, octyl salicylate, homosalate, 3-(4-methylbenzylidene) camphor, 2-hydroxy-4-methoxybenzophenone in aqueous samples was developed. The analytes were extracted by plunger-in-needle solid-phase microextraction with graphene as sorbent, then silylated on-fiber with N-methyl-N-(trimethylsilyl)trifluoroacetamide, and analyzed by gas chromatography–mass spectrometry. Factors affecting the performance of extraction and derivatization steps were thoroughly evaluated. For the optimization of extraction conditions, six relevant factors (parameters) were investigated, including sample pH, salt concentration, extraction time, extraction temperature, stirring speed and sampling mode. In the first stage, a two-level orthogonal array design OA8 (27) matrix was employed to study the effect of six factors. Based on the results of the first stage, three factors were selected for further optimization with a univariant approach during the second stage. Under the final optimized conditions, the method limits of detection for the five UV filters were determined to be in the range of 0.5 and 6.8 ng L−1 (at a signal/noise ratio of 3) and the precision (% relative standard deviation, n = 5) was 0.8–5.6% at a concentration level of 1 μg L−1. The linearities for different analytes were 10–10,000 or 1–5000 ng L−1. The coefficients of determination for the calibration curves were all greater than 0.994. Finally, the proposed method was successfully applied to the extraction and determination of the UV filters in river water samples.  相似文献   

15.
In this work the development and validation of a new procedure for the simultaneous determination of 9 nitro and polycyclic musk compounds: musk ambrette (MA), musk ketone (MK), musk mosken (MM), celestolide (ADBI), phantolide (AHMI), tonalide (AHTN), traseolide (ATII), cashmeran (DPMI) and galaxolide (HHCB) in environmental water samples (estuarine and wastewater) using microextraction by packed sorbent (MEPS) followed by large volume injection-gas chromatography–mass spectrometry (LVI-GC–MS) was carried out. Apart from the optimization of the different variables affecting MEPS (i.e., nature of the sorbent, nature of the solvent elution, sample load, and elution/injection volume) extraction recovery was also evaluated, not only for water samples but also for environmental water matrices such as estuarine and waste water. The use of two deuterated analogs ([2H3]-AHTN and [2H15]-MX) was successfully evaluated in order to correct matrix effect in complex environmental matrices such as influent samples from wastewater treatment plants. Method detection limits (MDLs) ranged from 5 to 25 ng L−1, 7 to 39 ng L−1 and 8 to 84 ng L−1 for influent, effluent and estuarine samples, respectively. Apparent recoveries were higher than 75% for all target compounds in all the matrices studied (estuarine water and wastewater) and the precision of the method, calculated as relative standard deviation (RSD), was below 13.2% at 200 ng L−1 concentration level and below 14.9% at low level (20 ng L−1 for all the target analytes, except for AHTN which was set at 40 ng L−1 and HHCB at 90 ng L−1, due to the higher MDL values presented by those target compounds). Finally, this MEPS procedure was applied to the determination of the target analytes in water samples, including estuarine and wastewater, from two estuaries, Urdaibai (Spain) and Adour (France) and an established stir-bar sorptive extraction-liquid desorption/large volume injection-gas chromatography–mass spectrometry (SBSE-LD/LVI-GC–MS) method was performed in parallel for comparison. Results were in good agreement for all the analytes determined, except for DPMI.  相似文献   

16.
Polybrominated diphenyl ethers (PBDEs) are flame retardants, which due to their widespread use are frequently present as pollutants in the environment. In the EU Water Framework Directive (WFD) six PBDE congeners (BDE 28, BDE47, BDE 99, BDE 100, BDE 153 and BDE 154) are listed as priority substances. The uncertainty of the analytical method used for their determination in water samples at environmental quality standard (EQS) level (0.5 ng L−1 for the ΣPBDEs) should be equal or less than 50% and the limit of quantification (LOQ) for ΣPBDEs below 0.15 ng L−1. To meet these requirements, an analytical procedure for the determination of these six PBDEs in environmental water samples by gas chromatography–inductively coupled plasma mass spectrometry (GC–ICP-MS) was developed. The acidification of water samples to pH 2 maintained the stability of PBDEs for at least 20 days. The use of Tris–citrate buffer enabled efficient desorption of PBDEs from suspended particulate matter (SPM) and humic acids (HA), and their further quantitative solvent extraction into 2 mL of iso-octane. When 300 mL of water sample was used for analysis and the organic phase concentrated to 25 μL, the expanded uncertainty for determination of PBDEs at EQS level was found to be around 40% (a coverage factor for a confidence level of 95%, k = 2), and the LOQ for the ΣPBDEs 0.109 ng L−1. Finally, to demonstrate the applicability of the newly developed GC–ICP-MS procedure, PBDEs were determined in river and sea water samples.  相似文献   

17.
José Robles-Molina 《Talanta》2010,82(4):1318-1324
In this work, we report the development and validation of an analytical method for the trace level determination of 14 selected (EU-directive) priority organic pollutants (namely, 1,2,3-trichlorobenzene (1,2,3-TCB), 1,2,4-trichlorobenzene, 1,3,5-trichlorobenzene, hexachloro-1,3-butadiene, pentachlorobenzene, hexachlorobenzene, alachlor, α-hexachloro-cyclohexane (α-HCH), β-HCH, γ-HCH (lindane), δ-HCH, tetra-brominated diphenyl ether (tetra-BDE), penta-brominated diphenyl ether and hepta-brominated diphenyl ether) in wastewater samples from 5 different sewage treatment plants (STPs) located in Spain. The proposed methodology is based on liquid-liquid extraction with n-hexane followed by identification and confirmation of the selected pollutants by gas chromatography high-resolution mass spectrometry in selected ion recording acquisition mode. Recovery studies performed with spiked wastewater samples at two different concentration levels (0.1 and 1 μg L−1) gave mean recoveries in the range 80-120% (except for trichlorobenzenes, ca. with 50%) with RSD values below 10% in most cases, thus confirming the usefulness of the proposed methodology for the analyses of this kind of complex samples. The obtained detection limits in effluent wastewater matrices were in the low nanogram per liter range, with values as low as 0.09 ng L−1 for tetra-BDE and 0.3 ng L−1 for hexachlorobenzene. Finally, the proposed methodology was successfully applied to a monitoring study intended to characterize wastewater effluents of 5 different sewage treatment plants with different major activities (Industrial, Coastal, Urban). Most of the compounds targeted were detected in the ng L−1 range at concentrations ranging from 0.19 ng L−1 to 135 ng L−1 (hexachlorobenzene).  相似文献   

18.
The distribution of pyrethroid and phenylpyrazole pesticides in the water environment has raised public concerns because of their potential risks to ecosystem and human health. However, co-extraction of emulsifier type compounds (by liquid–liquid extraction, LLE) present in environmental samples can present a challenge for quantifying typically low concentrations of pesticides. Several methods were evaluated for breaking emulsions in problematic environmental surface water samples extracted by LLE using methylene chloride. Target pesticides included 11 typical pyrethroid and phenylpyrazole pesticides commonly used in agricultural and landscape insect pest control. The most effective method was selected for validation in fortification studies with GC-ECD analysis. The average recoveries of spiked pyrethroid and phenylpyrazole pesticides were 88.2–123.4% for water samples with moderate emulsions and 93.0–117.4% for water samples with severe emulsions. Recoveries of the pesticides ranged 81.0–126.4% (water samples with moderate emulsions) and 95.9–110.6% (water samples with severe emulsions) for lowest fortification level (5–20 ng L−1), 88.2–123.4% (water samples with moderate emulsions) and 93.0–117.4% (water samples with severe emulsions) for middle fortification level (10–40 ng L−1), and 90.2–119.9% (water samples with moderate emulsions) and 91.2–105.9% (water samples with severe emulsions) for highest fortification level (50–200 ng L−1). Relative standard deviations of pesticide recoveries were usually <10%. Results indicate that this method is a robust and reproducible option for LLE of pyrethroid and phenylpyrazole pesticides from emulsion-prone surface water samples.  相似文献   

19.
A new, simple, fast and high sensitive analytical method based on dispersive liquid-liquid microextraction (DLLME) followed by gas chromatography-mass spectrometry (GC-MS) for the simultaneous determination of nitro musks in surface water and wastewater samples is presented. Different parameters, such as the nature and volume of both the extraction and disperser solvents and the ionic strength and pH of the aqueous donor phase, were optimized. Under the selected conditions (injection of a mixture of 1 mL of acetone as disperser solvent and 50 μL of chloroform as extraction solvent, no salt addition and no pH adjustment) the figures of merit of the proposed DLLME-GC-MS method were evaluated. High enrichment factors, ranging between 230 and 314 depending on the target analyte, were achieved, which redound to limits of detection in the ng L−1 range (i.e., 4-33 ng L−1). The relative standard deviation (RSD) was below 5% for all the target analytes. Finally, the recoveries obtained for different water samples of diverse origin (sea, river, irrigation channel and water treatment plant) ranged between 87 and 116%, thus showing no matrix effects.  相似文献   

20.
A simple ultrasound-assisted dispersive liquid–liquid microextraction method combined with liquid chromatography was developed for the preconcentration and determination of six pyrethroids in river water samples. The procedure was based on a ternary solvent system to formatting tiny droplets of extractant in sample solution by dissolving appropriate amounts of water-immiscible extractant (tetrachloromethane) in watermiscible dispersive solvent (acetone). Various parameters that affected the extraction efficiency (such as type and volume of extraction and dispersive solvent, extraction time, ultrasonic time, and centrifuging time) were evaluated. Under the optimum condition, good linearity was obtained in a range of 0.00059–1.52 mg L−1 for all analytes with the correlation coefficient (r2) > 0.999. Intra-assay and inter-assay precision evaluated as the relative standard deviation (RSD) were less than 3.4 and 8.9%. The recoveries of six pyrethroids at three spiked levels were in the range of 86.2–109.3% with RSD of less than 8.7%. The enrichment factors for the six pyrethroids were ranged from 767 to 1033 folds.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号