首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
Benzene is classified as a Group I carcinogen by the International Agency for Research on Cancer (IARC). The risk assessment for benzene can be performed by monitoring environmental and occupational air, as well as biological monitoring through biomarkers. The present work developed and validated methods for benzene analysis by GC/MS using SPME as the sampling technique for ambient air and breath. The results of the analysis of air in parks and avenues demonstrated a significant difference, with average values of 4.05 and 18.26 μg m−3, respectively, for benzene. Sampling of air in the occupational environment furnished an average of 3.41 and 39.81 μg m−3. Moreover, the correlations between ambient air and expired air showed a significant tendency to linearity (R 2 = 0.850 and R 2 = 0.879). The results obtained for two groups of employees (31.91 and 72.62 μg m−3) presented the same trend as that from the analysis of environmental air.  相似文献   

2.
Direct injection of urine has gained interest in the field of analytical toxicology, including doping control analysis. However, implementation of a direct urinalysis method for the LC–MS/MS detection of 34 diuretics and 9 other doping agents yielded several analytical problems, which were not observed using a traditional liquid–liquid extraction. Therefore a comparative study was made between liquid–liquid extraction and direct injection. Comparison of validation results showed that the liquid–liquid extraction at pH 7 allows to analyze samples without major drawbacks regarding matrix effects. Hence, good sensitivity was observed and detection limits ranged between 1 and 250 ng/mL for all compounds. In the direct injection approach shifted retention times were observed for several acidic and basic compounds due to unwanted matrix effects. This shift was reduced by a 25-fold dilution of the urine samples. Besides the improved retention time stability the diluted samples also exhibited lower ion suppression than the undiluted ones. After 25-fold dilution, detection limits ranged between 10 and 250 ng/mL for all compounds. Since these detection limits are at or below the minimum required performance level, imposed by the World Anti-Doping Agency, the method could be applied to routine anti-doping analysis. Samples, previously declared positive, were reanalysed using both the liquid–liquid extraction and direct injection. With both techniques all 26 samples were found to be positive, showing the applicability of direct injection for the analysis of diuretics.  相似文献   

3.
A simple, rapid and sensitive method was developed and validated for the analysis of C2–C5 volatile fatty acids (VFAs) in ambient air. This method involves preconcentration of VFAs with a sodium carbonate-impregnated silica gel tube, ultrasonic extraction with pure water, partition of VFAs to diethyl ether and determination using gas chromatography with a mass selective detector in the selected ion monitoring mode. A water-resistant free fatty acid phase capillary column was used to directly separate C2–C5 VFAs without the time-consuming derivatisation process. The limits of detection ranged from 0.001 to 0.003 µg m?3 and the limits of quantification ranged from 0.003 to 0.010 µg m?3. The validated method was successfully applied to the analysis trace-level VFAs in ambient air and in air samples from a landfill with perceived odour pollution.  相似文献   

4.
Data precision in the analysis by purge-and-trap coupled on-line to gas chromatography–mass spectrometry (P&T-GC–MS) of honey volatiles has been studied by statistical analysis. The contribution of non-random factors to dispersion of quantitative results was proven by comparing several statistical parameters (correlation coefficients, principal component analysis (PCA) eigenvalues and loadings) from both experimental and simulated data. PCA was also useful for grouping volatiles with similar dispersion behaviour; these groups being generally related to compounds with common properties or structural features. The use of area ratios improves data precision for compounds within the same group. Results from this study could be used for a better selection of internal standards in quantitative analysis of volatiles by P&T-GC–MS.  相似文献   

5.
The recent technological advancements of liquid chromatography–tandem mass spectrometry allow the simultaneous determination of tens, or even hundreds, of target analytes. In such cases, the traditional approach to quantitative method validation presents three major drawbacks: (i) it is extremely laborious, repetitive and rigid; (ii) it does not allow to introduce new target analytes without starting the validation from its very beginning and (iii) it is performed on spiked blank matrices, whose very nature is significantly modified by the addition of a large number of spiking substances, especially at high concentration. In the present study, several predictive chemometric models were developed from closed sets of analytes in order to estimate validation parameters on molecules of the same class, but not included in the original training set. Retention time, matrix effect, recovery, detection and quantification limits were predicted with partial least squares regression method. In particular, iterative stepwise elimination, iterative predictors weighting and genetic algorithms approaches were utilized and compared to achieve effective variables selection. These procedures were applied to data reported in our previously validated ultra-high performance liquid chromatography–tandem mass spectrometry multi-residue method for the determination of pharmaceutical and illicit drugs in oral fluid samples in accordance with national and international guidelines. Then, the partial least squares model was successfully tested on naloxone and lormetazepam, in order to introduce these new compounds in the oral fluid validated method, which adopts reverse-phase chromatography. Retention time, matrix effect, recovery, limit of detection and limit of quantification parameters for naloxone and lormetazepam were predicted by the model and then positively compared with their corresponding experimental values. The whole study represents a proof-of-concept of chemometrics potential to reduce the routine workload during multi-residue methods validation and suggests a rational alternative to ever-expanding procedures progressively drifting apart from real sample analysis.  相似文献   

6.
The time-honored convention of concentrating aqueous samples by solid-phase extraction (SPE) is being challenged by the increasingly widespread use of large-volume injection (LVI) liquid chromatography–mass spectrometry (LC–MS) for the determination of traces of polar organic contaminants in environmental samples. Although different LVI approaches have been proposed over the last 40 years, the simplest and most popular way of performing LVI is known as single-column LVI (SC-LVI), in which a large-volume of an aqueous sample is directly injected into an analytical column. For the purposes of this critical review, LVI is defined as an injected sample volume that is ≥10% of the void volume of the analytical column. Compared with other techniques, SC-LVI is easier to set up, because it requires only small hardware modifications to existing autosamplers and, thus, it will be the main focus of this review. Although not new, SC-LVI is gaining acceptance and the approach is emerging as a technique that will render SPE nearly obsolete for many environmental applications. In this review, we discuss: the history and development of various forms of LVI; the critical factors that must be considered when creating and optimizing SC-LVI methods; and typical applications that demonstrate the range of environmental matrices to which LVI is applicable, for example drinking water, groundwater, and surface water including seawater and wastewater. Furthermore, we indicate direction and areas that must be addressed to fully delineate the limits of SC-LVI.  相似文献   

7.
An analytical procedure based on extraction by accelerated solvent extraction (ASE) followed by gas chromatography–mass spectrometry (GC/MS) analysis has been developed for the determination of particulate polycyclic aromatic hydrocarbons (PAHs) from large-volume water samples (20 L). The effect of temperature and number of cycles on the efficiency of ASE was investigated: the best results were obtained by using a temperature of 100°C and one static cycle. A mixture of hexane/acetone 1:1 (v/v) was used as extraction solvent. Mean total method recovery under optimized conditions was 85%. The developed methodology was applied to the analysis of suspended particulate matter from Lake Maggiore waters (north of Italy). Mean PAH concentrations in suspended particulate matter from Lake Maggiore ranged from 0.2 ng L−1 for anthracene to 18.7 ng L−1 for naphthalene.  相似文献   

8.
Gas chromatography–mass spectrometry was used for the determination of 16 priority polycyclic aromatic hydrocarbons (PAHs) in surface soils from seventeen areas in Southeast Romania, including sites placed in the vicinity of Galati iron and steel plant and Lower Prut Meadow natural reserve in Galati County. The total concentration of PAHs (TPAHs) in the investigated soils ranges from 0.003 mg/kg to 38.524 mg/kg dry weight. According to Romanian legislation for trace organic compounds in soils of different uses, the amounts of PAHs in soils from the industrial zone exceed the normal values for the majority of individual PAHs. The lowest concentrations were found in soils sampled from the protected area of Lower Prut Meadow natural reserve and the highest near a zootechnique farm in the Prut River basin, where the alert levels exceeded for the less sensitive area in the case of TPAHs and benzo[b]fluoranthene and for the sensitive area in the case of chrysene, benz[a]anthracene, benzo[k]fluoranthene and benzo[g,h,i]perylene. The sources of PAH contaminating soils are complex, being of both pyrogenic and petrogenic origins.  相似文献   

9.
A bioanalytical method was developed for the simultaneous determination of paracetamol and ketorolac enantiomers in human plasma using two-dimensional liquid chromatography–mass spectrometry. Separation was first achieved in a reversed-phase C18 column by using a gradient solvent system consisting of 0.1% aqueous formic acid and acetonitrile (ACN). The effluent between 8.9 and 9.9 min, corresponding to phenacetin and racemic ketorolac peaks, was transferred to a polysaccharide-based chiral column (ChiralPak AD-RH) by using a six-port switching valve. Ketorolac enantiomers were subsequently separated on the chiral column using an isocratic mobile phase composed of ACN/0.1% formic acid 50:50 (v/v). The total run-time was less than 18 min. This innovative strategy prolongs the lifetime of chiral columns by avoiding damages due to the sample matrix. The detection was carried out with an ion trap mass spectrometer equipped with an electrospray ionisation source. The tested ranges were 0.05–20 μg/ml for paracetamol and 0.005–2 μg/ml for each ketorolac enantiomer. This method was fully validated and showed good performances in terms of trueness (80–110%) and precision (6.7–13.2%). The mean extraction recoveries were 60%, 72% and 76% for paracetamol, R-ketorolac and S-ketorolac, respectively. Finally, this procedure was successfully applied to a pharmacokinetic study.  相似文献   

10.
The analysis of amino acids by gas chromatography mass spectrometry (GC–MS) after their derivatization with N-(t-butyldimethylsilyl)-N-methyltrifluoroacetamide was investigated as an alternative approach for the determination of free (FAA) and combined amino acids (CAA) in aerosols. This technique showed excellent linearity with r2 values ranging from 0.9029 to 0.9995 and instrumental limits of detection ranging from 0.3 to 46 pg for the different amino acids. The quality of water used for sample extraction was found to be of utmost importance for achieving low blank levels of FAA and CAA. The addition of isopropanol during the extraction of aerosols was also shown to minimize the coextraction of inorganic salts that interfered with the analysis of FAA, Moreover, the ascorbic acid was found to be the most effective reagent for preventing the oxidative destruction of CAA during the hydrolysis process. By the analysis of spiked aerosol samples, the average recoveries determined for FAA and CAA were higher than 60% and the associated relative standard deviation was lower than 10% for the majority of amino acids. The application of the adopted method in background aerosols of the eastern Mediterranean enabled the unambiguous identification and quantification of 20 amino acids. The total concentration of FAA and CAA in aerosols ranged from 13 to 34 ng m−3 and from 29 to 79 ng m−3, respectively. The GC–MS based method is proposed to overcome several analytical difficulties usually encountered with the conventional HPLC-fluoresence technique.  相似文献   

11.
In this study, the feasibility of GC–MS was evaluated for the quantification of odorous volatile organic compounds (VOCs) in environmental samples. These included methyl ethyl ketone, isobutyl alcohol, methyl isobutyl ketone, and butyl acetate plus benzene, toluene, and xylene (BTX). For this purpose, the gaseous standard for these VOCs were analyzed by GC–MS with the aid of both direct injection (DI) into the GC injector and solid-phase microextraction (SPME). The liquid phase standard prepared independently was tested additionally by the DI method as a reference to gaseous calibration. The detection limit (DL) values, when tested for basic quality assurance in this study, showed large differences between DI (0.002–0.007 ng) and SPME method (1.03–1.81 ng) in terms of absolute mass. The DL values, when expressed in terms of concentration (v/v), showed considerable improvement in SPME (below 0.40 nmol mol−1) relative to the DI method (∼6–15 nmol mol−1). The reliability of the GC–MS method was further validated through an analysis of real environmental samples collected from an industrial area.  相似文献   

12.
A sensitive and solvent-free method for the determination of ten polycyclic aromatic hydrocarbons, namely, naphthalene, acenaphthylene, acenaphthene, fluorene, phenanthrene, anthracene, fluoranthene, pyrene, benzo[a]anthracene and chrysene, with up to four aromatic rings, in milk samples using headspace solid-phase microextraction and gas chromatography–mass spectrometry detection has been developed. A polydimethylsiloxane–divinylbenzene fiber was chosen and used at 75°C for 60 min. Detection limits ranging from 0.2 to 5 ng L−1 were attained at a signal-to-noise ratio of 3, depending on the compound and the milk sample under analysis. The proposed method was applied to ten different milk samples and the presence of six of the analytes studied in a skimmed milk with vegetal fiber sample was confirmed. The reliability of the procedure was verified by analyzing two different certified reference materials and by recovery studies. Figure Milk is safe, healthy food  相似文献   

13.
Fragrances are ubiquitous pollutants in the environment, present in the most of household products, air fresheners, insecticides and cosmetics. Commercial perfumes may contain hundreds of individual fragrance chemicals. In addition to the widespread use and exposure to fragranced products, many of the raw fragrance materials have limited available health and safety data. Because of their nature as artificial fragrances, inhalation should be considered as an important exposure pathway, especially in indoor environments. In this work, a very simple, fast, and sensitive methodology for the analysis of 24 fragrance allergens in indoor air is presented. Considered compounds include those regulated by the EU Directive, excluding limonene; methyl eugenol was also included due to its toxicity. The proposed methodology is based on the use of a very low amount of adsorbent to retain the target compounds, and the rapid ultrasound-assisted solvent extraction (UAE) using a very low volume of solvent which avoids further extract concentration. Quantification was performed by gas chromatography coupled to mass spectrometry (GC–MS). The influence of main factors involved in the UAE step (type of adsorbent and solvent, solvent volume and extraction time) was studied using an experimental design approach to account for possible factor interactions. Using the optimized procedure, 0.2 m−3 air are sampled, analytes are retained on 25 mg Florisil, from which they are extracted by UAE (5 min) with 2 mL ethyl acetate. Linearity was demonstrated in a wide concentration range. Efficiency of the total sampling-extraction process was studied at several concentration levels (1, 5 and 125 μg m−3), obtaining quantitative recoveries, and good precision (RSD < 10%). Method detection limits were ≤0.6 μg m−3. Finally, the proposed method was applied to real samples collected in indoor environments in which several of the target compounds were determined.  相似文献   

14.
Volatile organic compounds (VOCs) and odors in cattle rumen gas have been characterized by in-vivo headspace sampling by solid-phase microextraction (SPME) and analysis by gas chromatography–mass spectrometry–olfactometry (GC–MS–O). A novel device enabling headspace SPME (HS-SPME) sampling through a cannula was designed, refined, and used to collect rumen gas samples from steers. A Carboxen–polydimethylsiloxane (PDMS) fiber (85 μm) was used for SPME sampling. Fifty VOCs from ten chemical groups were identified in the rumen headspace. The VOCs identified had a wide range of molecular weight (MW) (34 to 184), boiling point (−63.3 to 292 °C), vapor pressure (1.05 × 10−5 to 1.17 × 102 Pa), and water solubility (0.66 to 1 × 106 mg L−1). Twenty-two of the compounds have a published odor detection thresholds (ODT) of less than 1 ppm. More than half of the compounds identified are reactive and have an estimated atmospheric lifetime of <24 h. The amounts of VFAs, sulfide compounds, phenolic compounds, and skatole, and the odor intensity of VFAs and sulfide compounds in the rumen gas were all higher after feeding than before feeding. These results indicate that rumen gases can be an important potential source of aerial emissions of reactive VOCs and odor. In-vivo sampling by SPME then GC–MS–O analysis can be a useful tool for qualitative characterization of rumen gases, digestion, and its relationship to odor and VOC formation. Figure Modified cannula for rumen gas sampling with SPME  相似文献   

15.
Pyrolysis gas chromatography–mass spectroscopy (PGC–MS) has been proved to be a powerful method to analyze both the volatile additives and the macromolecular structure of polymer materials. In this paper, flash evaporation technique was used to analyze the volatile degradation products of polymer materials during natural and artificial aging. In high density polyethylene (HDPE) composites, mainly n-alkanes with carbon number from 14 to 29 were detected after natural aging, while no oxidative product was found. Different composites have different n-alkane distributions. In contrast, various oxidative products including ketones, alcohols, esters and unsaturated species could be found in aged polypropylene (PP) nanocomposites. Nanoparticles accelerated the chain scission of PP and increased the formation of oxidative products significantly. During thermal oxidation of nitrile rubber (NBR) seal rubbers, heat/oxidation-induced extra crosslinking predominated and no volatile degradation products was detected. The main change happened in the volatiles is the decrease of additives, especially paraffins, antioxidant RD and hindered phenol. This resulted in the hardening of the rubber and the weakening of the protection from oxidation. Furthermore, the additive distribution along the depth was investigated, showing different migration speeds of different additives. From the additive levels remained in the NBR rubber, it is possible to predict the degradation status. In summary, PGC–MS can supply abundant information of polymer degradation and is helpful for mechanism research.  相似文献   

16.
Animal-derived products are particularly vulnerable to contamination by volatile organic compounds (VOCs). These lipophilic substances, which are generated by an increasing number of sources, are easily transferred to the atmosphere, water, soil, and plants. They are ingested by livestock and become trapped in the fat fraction of edible animal tissues. The aim of this work was to determine the occurrence, risk for human health and entryways of benzenic and halogenated VOCs (BHVOCs) in meat products, milks and sea foods using gas chromatography– mass spectrometry (GC–MS) techniques. In the first part, the occurrence and levels of the BHVOCs in animal products were studied. One muscle and three fat tissues were analysed by GC–Quad/MS in 16 lambs. Of 52 BHVOCs identified, 46 were found in the three fat tissues and 29 in all four tissues, confirming that VOCs are widely disseminated in the body. Twenty-six BHVOCs were quantified in fat tissues, and risk for consumer health was assessed for six of these compounds regulated by the US Environmental Protection Agency (EPA). The BHVOC content was found to be consistent with previous reports and was below the maximum contaminant levels set by the EPA. In the second part, the performance of GC×GC–TOF/MS for comprehensively detecting BHVOCs and showing their entryways in animal-derived food chains was assessed. Meat, milk and oysters were analysed by GC–Quad/MS and GC×GC–TOF/MS. For all these products, at least a 7-fold increase in the contaminants detected was achieved with the GC×GC–TOF/MS technique. The results showed that the production surroundings, through animal feeding or geographical location, were key determinants of BHVOC composition in the animal products.  相似文献   

17.
A multiresidue method is described for simultaneous estimation of 83 pesticides and 12 dioxin-like polychlorinated biphenyls (PCBs) in red and white wines. The samples (20 mL wine, acidified with 20 mL 1% HCl) were extracted with 10 mL ethyl acetate (+20 g sodium sulphate) and cleaned by dispersive solid-phase extraction (DSPE) with anhydrous calcium chloride and Florisil successively. The final extract (5 mL) was solvent exchanged to 1 mL of cyclohexane:ethyl acetate (9:1), further cleaned by DSPE with 25 mg primary secondary amine sorbent and analyzed by gas chromatography–time-of-flight mass spectrometry (GC–TOF-MS) within 31 min run time. The limits of quantification of most analytes were ≤10–20 μg/L. Acidification of wine prior to extraction prevented hydrolysis of organophosphorous pesticides as well as dicofol, whereas treatment with CaCl2 minimized the fatty acid co-extractives significantly. Solvent exchange to cyclohexane:ethyl acetate (9:1) further minimized the co-extractives. Recoveries at 5, 10 and 20 ng/mL were >80% for most analytes except cyprodinil, buprofezin and iprodione. The expanded uncertainties at 10 ng/mL were <20% for most analytes. Intra-laboratory precision in terms of Horwitz ratio of all the analytes was below 0.5, suggesting ruggedness of the method. Effectively, the method detection limit for most analytes was as low as up to 1 ng/mL in both red and white wine, except for cyfluthrin and cypermethrin.  相似文献   

18.
In this study an on-line column-switching fast LC–MS/MS method was developed to analyze bisphenol A (BPA) and its chlorinated derivatives in water. Fast liquid chromatographic separation was performed on a C18 reversed phase column based on fused-core particle technology (2.7 μm particle size) providing analysis times shorter than 3 min and high peak efficiencies. The main benefit of this LC system is that it can easily be hyphenated to a conventional on-line preconcentration device allowing the direct analysis of water samples without any pretreatment at concentrations levels down to 60 ng L−1 and preventing contaminations frequently reported in the analysis of BPA. This on-line SPE fast LC system was coupled to a triple quadrupole mass spectrometer operating in enhanced mass resolution mode (Q1 FWHM = 0.7 Th, Q3 FWHM = 0.1 Th) in order to minimize interferences and chemical noise. This highly sensitive and selective method was successfully employed to analyze BPA and its chlorinated derivatives in water samples.  相似文献   

19.
The study describes the determination of mono-hydroxylated polycyclic aromatic hydrocarbons (OH-PAHs), metabolites of PAHs, in human hair. Twelve selected OH-PAHs from two to four rings, generally determined in urine analysis, were investigated as markers of human exposure to PAHs. Following hydrolysis of hair specimens of 50–300 mg with 1 M NaOH, OH-PAHs were extracted using dichloromethane and submitted to an optimized derivatization with (2S,4R)-N-heptafluorobutyryl-4-heptafluorobutoyloxy-prolyl chloride. Compounds were then analyzed using gas chromatography–negative chemical ionization mass spectrometry (GC–NCIMS). The average inter-day and intra-day variability was 12% and 17%, respectively. The average recovery was 52% and the limits of detection and quantification ranged from 20 and 66 pmol/g for 1-OH-phenanthrene (i.e., 3.9 and 12.8 pg/mg) to 311 and 1030 pmol/g for 2-OH-benzo(c)phenanthrene (i.e., 75.9 and 251 pg/mg). The influence of hair washing with water as decontamination step, and enzymatic treatment (β-glucuronidase) to hydrolyze conjugated derivatives were also tested. The application of the developed method to the analysis of 30 hair specimens (17 from non-smoker and 13 from smoker volunteers) demonstrated inter-individual qualitative and quantitative variations. According to the easiness of hair sampling and based on the extended detection windows provided by hair analysis, this method is proposed as a new promising tool for the assessment of human chronic exposure to PAHs.  相似文献   

20.
An ultra-high-pressure liquid chromatography–tandem mass spectrometry (UHPLC–MS/MS) method for the determination of 37 pesticides (herbicides, insecticides and fungicides) in environmental and wastewater has been developed. To efficiently combine UHPLC with MS/MS, a fast-acquisition triple quadrupole mass analyzer was used. This analyzer (minimum dwell time, 5 ms) allows acquiring up to three simultaneous transitions in the selected reaction monitoring mode for each compound assuring a reliable identification without resolution or sensitivity losses. A pre-concentration step based on solid-phase extraction using Waters Oasis HLB cartridges (0.2 g) was applied with a 100-fold pre-concentration factor along the whole analytical procedure. The method was validated based on European SANCO guidelines using surface, ground, drinking and treated water (from an urban solid residues treatment plant) spiked at two concentration levels (0.025 and 0.1 μg/L), the lowest having been established as the limit of quantification objective. The method showed excellent sensitivity, with instrumental limits of detection ranging from 0.1 to 7 pg. It was applied to environmental water samples (ground and surface water) as well as to samples of urban solid waste leachates (raw leachate and treated leachate after applying reversed osmosis) collected from a municipal treatment plant. Matrix effects have been studied in the different types of water samples analyzed, and several isotope-labelled internal standards have been evaluated as a way to compensate the signal suppression observed for most of the compounds studied, especially in wastewater samples. As a general remark, only those pesticides which response was corrected using their own isotope-labelled molecule, could be satisfactorily corrected in all type of samples, assuring in this way the accurate quantification in all matrix samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号