首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A simple and fast capillary chromatographic method has been developed to identify and quantify organic pollutants at sub-ppb levels in real water samples. The major groups of pesticides (organic halogens, organic phosphorous, and organic nitrogen compounds), some hydrocarbons (polycyclic aromatic hydrocarbons), phthalates and some phenols such as phenol and bisphenol A (endocrine disruptors) were included in this study. The procedure was based on coupling, in-tube solid-phase microextraction (IT-SPME) by using a conventional GC capillary column (95% methyl–5% phenyl substituted backbone, 80 cm × 0.32 mm i.d., 3 μm film thickness) in the injection valve to capillary liquid chromatography with diode array detection. A comparative study between the IT-SPME manifold and a column-switching device using a C18 column (35 mm × 0.5 mm i.d., 5 μm particle size) has been performed. The IT-SPME procedure was optimal, it allows reaching limits of detection (LODs) between 0.008 and 0.2 μg/L. No matrix effect was found and recoveries between 70 and 116% were obtained. The precision of the method was good, and the achieved intra- and inter-day variation coefficients were between 2 and 30%. This procedure has been applied to the screening analysis of 28 compounds in whole waters from several points of the Mediterranean coast (Valencia Community, Spain).  相似文献   

2.
This article reports on the effective extraction of triazines from environmental water samples using magnetism-enhanced monolith-based in-tube solid phase microextraction (ME-MB/IT-SPME). Firstly, monolithic poly (octyl methacrylate-co-ethyleneglycol dimethacrylate) capillary column doped with magnetic nanoparticles was synthesized inside a fused silica. After that, the monolithic capillary column was placed inside a magnetic coil that allowed the exertion of a variable magnetic field during adsorption and desorption steps. The effects of intensity of magnetic field, adsorption and desorption flow rate, volume of sample and desorption solvent, pH value and ionic strength in sample matrix on the performance of ME-MB/IT-SPME for triazines were investigated in details. Under the optimized conditions, the developed ME-MB/IT-SPME showed satisfactory quantitative extraction efficiencies of the target analytes between 64.8% and 99.7%. At the same time, the ME-MB/IT-SPME was combined with high-performance liquid chromatography with diode array detection to detect six triazines in water samples. The limits of detection (S/N = 3) and limits of quantification (S/N = 10) were in the ranges of 0.074–0.23 μg/L and 0.24–0.68 μg/L, respectively. The precision of the proposed method was evaluated in terms of intra- and inter-assay variability calculated as relative standard deviation, and it was found that the values were all below 10%. Finally, the developed method was successfully applied for environmental water samples such as farmland, lake and river water with spiked recoveries in the range of 70.7–119%.  相似文献   

3.
A new device for carbonyl compounds based on coupling on-line and miniaturizing both, sample pretreatment and chromatographic separation, is reported. Two capillary columns, a GC capillary column (95% methyl-5% phenyl substituted backbone, 70 cm × 0.32 mm i.d., 3 μm film thickness) in the injection valve for in-tube solid-phase microextraction (IT-SPME) and a Zorbax SB C18 (150 mm × 0.5 mm i.d., 5 μm particle diameter) LC capillary column were employed. Different combinations of IT-SPME and derivatization using 2,4-dinitrophenylhydrazine (DNPH) were examined for mixtures containing 15 carbonyl compounds (aliphatic, aromatic and unsaturated aldehydes and ketones). A screening analysis of aqueous extracts of atmospheric particulate PM(10) was carried out. Moreover, the possibility of coupling IT-SPME and conventional liquid chromatography is also tested. Derivatization solution and IT-SPME coupled to capillary liquid chromatography provided the best results for achieving the highest sensitivity for carbonyl compounds in atmospheric particulate analysis. Detection limits (LODs) using a photodiode array detector (DAD) were ranged from 30 to 198 ng L(-1), improving markedly those LODs reported by conventional SPME-LC-DAD.  相似文献   

4.
A poly (methacrylic acid-ethylene glycol dimethacrylate) monolithic capillary column was prepared for in-tube solid-phase microextraction. Comparing with the commonly used open tubular extraction capillary, which cannot provide sufficient extraction efficiency since the ratio of its coating volume to that of the capillary void volume is relatively small, the monolithic column with greater phase ratio combined with convective mass transfer provides the possibility to improve the extraction efficiency with shorter capillary. As to poly (methacrylic acid-ethylene glycol dimethacrylate), its hydrophobic main chains and acidic pendant groups make it a superior material for extraction of basic analytes from aqueous matrix.An on-line monolithic capillary column solid phase microextraction (SPME) method was developed for determination of theobromine, theophylline and caffeine in serum samples. The high extraction efficiency was obtained for all the three analytes, yielding the detection limits of 12, 8 and 6.5 ng/mL by UV detection, respectively. Excellent method reproducibility (R.S.D. < 2.9%) was found over a linear dynamic range of 0.05-2 μg/mL in serum sample. The monolithic capillary column was proved to be reusable in coping with serum samples, which would facilitate practical determination of basic drugs.  相似文献   

5.
Liu AL  He FY  Hu YL  Xia XH 《Talanta》2006,68(4):1303-1308
Rapid separation and determination of acetaminophen and its hydrolysate with end-channel electrochemical (EC) detection integrated on a plastified poly(ethylene terephthalate) (PET)-toner microchip capillary electrophoresis (CE) system was investigated. In this separation and detection system, a Pt ultramicroelectrode integrated on a three-dimensional adjustor was used as working electrode. Factors influencing the separation and detection were investigated and optimized. Results show that acetaminophen and p-aminophenol can be well separated within 84 s with R.S.D. < 1% for migration time and R.S.D. < 3.6% for detection current for both analytes. Detection limits for both analytes are determined to be 5.0 μM (S/N = 3). This method has been successfully applied to the detection of trace p-aminophenol in paracetamol tablets. The results demonstrate that the PET-toner microchips can obtain better performance than PDMS microfluidic devices but at much lower cost.  相似文献   

6.
Two novel methodologies for quantification of C13 norisoprenoids in wines were developed. The first methodology, method A (reference method) was based on the headspace solid-phase microextraction combined with gas chromatography–quadrupole mass spectrometry operating in selected ion monitoring mode (HS-SPME–GC–qMS–SIM). This methodology allowed to select the GC conditions for an adequate chromatographic resolution of wine components. The second methodology, method B (rapid method) was based on the HS-SPME–GC–qMS–SIM, using GC conditions that allowed to obtain a C13 norisoprenoid volatile signature. In the later, the GC capillary column of 30 m at 220 °C was used acting as a transfer line of the components sorbed by the SPME coating fibre to the mass spectrometer, which acts as a sensor for m/z fragments 142 and 192. It does not require any pre-treatment of the sample, and the C13 norisoprenoid composition of the wine was evaluated based on the chromatographic profile and specific m/z fragments, without complete chromatographic separation of its components. For quantification purposes, external calibration curves were constructed with β-ionone chemical standard. Calibration curves with regression coefficient (r2) of 0.9940 and 0.9968, RSD of 1.08% and 12.51%, and detection limits of 1.10 and 1.57 μg L−1 were obtained for methods A and B, respectively. These methodologies were applied to seventeen white and red table wines. Two vitispirane isomers (158–1529 μg L−1) and 1,1,6-trimethyl-1,2-dihydronaphthalene (TDN) (6.42–39.45 μg L−1) were quantified. The data obtained for vitispirane isomers and TDN using the two methods were highly correlated (r2 of 0.9756 and 0.9630, respectively). Associated to the fast and robust character of the proposed rapid method B and considering the extraction time, it is important to focus its selectivity and potential applicability if specific m/z fragments would be established for new analytes.  相似文献   

7.
Ruecha N  Siangproh W  Chailapakul O 《Talanta》2011,84(5):1323-1328
In this work, the rapid detection of cholesterol using poly(dimethylsiloxane) microchip capillary electrophoresis, based on the coupling of enzymatic assays and electrochemical detection, was developed. Direct amperometric detection for poly(dimethylsiloxane) (PDMS) microchip capillary electrophoresis was successfully applied to quantify cholesterol levels. Factors influencing the performance of the method (such as the concentration and pH value of buffer electrolyte, concentration of cholesterol oxidase enzyme (ChOx), effect of solvent on the cholesterol solubility, and interferences) were carefully investigated and optimized. The migration time of hydrogen peroxide, product of the reaction, was less than 100 s when using 40 mM phosphate buffer at pH 7.0 as the running buffer, a concentration of 0.68 U/mL of the ChOx, a separation voltage of +1.6 kV, an injection time of 20 s, and a detection potential of +0.5 V. PDMS microchip capillary electrophoresis showed linearity between 38.7 μg/dL (1 μM) and 270.6 mg/dL (7 mM) for the cholesterol standard; the detection limit was determined as 38.7 ng/dL (1 nM). To demonstrate the potential of this assay, the proposed method was applied to quantify cholesterol in bovine serum. The percentages of recoveries were assessed over the range of 98.9-101.8%. The sample throughput was found to be 60 samples per hour. Therefore, PDMS microchip capillary electrophoresis, based on the coupling of enzymatic assays and electrochemical detection, is very rapid, accurate and sensitive method for the determination of cholesterol levels.  相似文献   

8.
Mai TD  Hauser PC 《Talanta》2011,84(5):1228-1233
Pressure assisted capillary electrophoresis in capillaries with internal diameters of 10 μm was found possible without significant penalty in terms of separation efficiency and sensitivity when using contactless conductivity detection. A sequential injection analysis manifold consisting of a syringe pump and valves was used to impose a hydrodynamic flow in the separation of some inorganic as well as organic cations. It is demonstrated that the approach may be used to optimize analysis time by superimposing a hydrodynamic flow parallel to the electrokinetic motion. It is also possible to improve the separation by using the forced flow to maintain the analytes in the capillary, and thus the separation field, for longer times. The use of the syringe pump allows flexible and precise control of the pressure, so that it is possible to impose pressure steps during the separation. The use of this was demonstrated for the speeding up of late peaks, or forcing repeated passage of the sample plug through the capillary in order to increase separation.  相似文献   

9.
A method based on capillary electrophoresis with electrochemical detection has been developed for the separation and determination of mannitol, sucrose, glucose, and fructose in Ligustrum lucidum Ait. for the first time. Effects of several important factors such as the concentration of NaOH, separation voltage, injection time, and detection potential were investigated to acquire the optimum conditions. The detection electrode was a 300 μm diameter copper disc electrode at a working potential of +0.65 V (versus saturated calomel electrode (SCE)). The four analytes can be well separated within 13 min in a 40 cm length fused-silica capillary at a separation voltage of 12 kV in a 75 mM NaOH aqueous solution. The relation between peak current and analyte concentration was linear over about three orders of magnitude with detection limits (S/N = 3) ranging from 1 to 2 μM for all analytes. The proposed method has been successfully applied to monitor the mannitol and sugar contents in the plant samples at different growth stages with satisfactory assay results.  相似文献   

10.
p-tert-Butylcalix[8]arene bonded capillaries for open-tubular capillary electrochromatography were prepared with γ-glycidoxypropyltrimethoxysilane as a bridge. The bonded capillary displayed low and steady electroosmotic flow (EOF) values over the pH range from 4 to 9. Detection limits for direct spectrophotometric detection at 277 nm for benzenediols (at a signal to noise ratio of 2) were 0.96 mg l−1 for the unbonded capillary and 1.48 mg l−1 for the bonded capillary, showing that the bonded layer did not show significant absorbance and hence decreased sensitivity. The bonded capillaries showed good separation selectivity for o-, m- and p-benzenediols, α- and β-naphthols, and α- and β-naphthylamines. This selectivity was attributed to significant interactions between the analytes and the bonded p-tert-butylcalix[8]arene, which contributed to the electrochromatographic separation mechanism. The bonded capillaries gave high stability and reproducibility.  相似文献   

11.
A monolithic column was prepared using l-phenylalanine as template and a covalent approach through the formation of Schiff base with o-phthalaldehyde (OPA). OPA, allylmercaptan, l-phenylalanine, and triethylamine were stirred at first, then methacrylic acid, 2-vinylpyridine, ethyleneglycol dimethacrylate, α,α-azobisisobutyronitrile, and 1-propanol were added to the reaction mixture. The resulting material was introduced into a capillary column. Following thermal polymerization, the template was then extracted with a mixture of HCl and methanol. The column was employed for the capillary electrochromatographic separation of oligopeptides. A capillary column of 75 (50) cm × 75 μm ID with a mobile phase of phosphate buffer (pH 7.0, 40 mM)/methanol (5%, v/v), an applied voltage of +15 kV, and detection at 214 nm, could baseline separate angiotensin I, angiotensin II, [Sar1, Thr8] angiotensin, oxytocin, vasopressin, tocinoic acid, β-casomorphin bovine, β-casomorphin human, and FMRF amide within 20 min. The separation behavior of the templated polymer was also compared with that of the non-templated polymer. As a result, it can be concluded that the electrochromatographic separation of this set of peptides was mediated by a combination of electrophoretic migration and chromatographic retention involving hydrophobic, hydrogen bonding, electrostatic as well as the Schiff base formation with OPA in the cavity of the templated polymer.  相似文献   

12.
Xu X  Ye H  Wang W  Yu L  Chen G 《Talanta》2006,68(3):759-764
Four flavonoids (rutin, hyperoside, quercitrin and quercetin) in Houttuynia cordata Thunb. and Saururus chinensis (Lour.) Bail. were determined by capillary electrophoresis with wall-jet amperometric detection. The working electrode was a 500 μm diameter carbon disc electrode and the detection potential was +0.95 V (versus Ag/AgCl). Effects of several important factors, such as the running buffer and its corresponding pH and concentration, separation voltage, injection time were investigated to acquire the optimum conditions for separation of these four flavonoids. Baseline separation for the four flavonoids was obtained within 21 min in a 60 cm length capillary at a separation voltage of 15 kV with a 60 mmoL/L Na2B4O7-120 mmoL/L NaH2PO4 buffer (pH 8.8) as running buffer. The relationship between peak currents and analyte concentrations was linear over about two orders of magnitude with detection limits (defined as S/N = 3) ranging from 0.02 to 0.05 μg/mL for all analytes. This method was applied for the determination of the above four flavonoids in H. cordata Thunb. and S. chinensis (Lour.) Bail. with simple extraction procedures, and the assay results were satisfactory.  相似文献   

13.
This paper reports on a new strategy to coat fused silica capillaries through ionic adsorption of gold nanoparticles (AuNPs) on a polyelectrolyte multilayer (PEM) modified capillary wall. The coating was constructed in situ by alternating rinses with positively charged poly(diallydimethylammonium chloride), negatively charged poly(sodium-4-styrenesulfonate), and positively charged AuNPs. After self-assembly of n-octadecanethiol onto the surface of AuNPs, the modified capillary was investigated as a new medium for the separation of neutral analytes and proteins in open-tubular capillary electrochromatography (OT-CEC). The surface coverage of the capillary wall was increased using the high density of AuNPs which were dynamically capped with 4-dimethylaminopyridine (DMAP). The chromatographic performance of the column coated with positively charged AuNPs was remarkably improved compared with a column modified with negatively charged AuNPs. The coating was robust over more than 810 runs in this study and also showed high stability against 0.01 M NaOH, 0.01 M HCl, and electrolyte concentrations up to 70 mM. The run-to-run, day-to-day, and capillary-to-capillary reproducibilities of electroosmotic flow were satisfying with relative standard deviation values of less than 1% in all cases. The AuNP-coated PEM modified capillary column not only showed good performance for neutral analytes but also was suitable for the analysis of both basic and acidic proteins.  相似文献   

14.
The present paper describes the development and validation of a new reversed-phase liquid chromatography–electrospray ionization tandem mass spectrometric method (RP-HPLC–ESI-MS/MS) for simultaneous determination of pyridine, 2-picoline, 4-picoline and quinoline from mainstream cigarette smoke. Liquid–liquid extraction followed by solid-phase extraction was applied to extract the target analytes from cigarette smoke. Baseline chromatographic separation was achieved by utilizing a Zorbax SB-Aq (4.6 × 150 mm, 5 μm) column in gradient chromatographic conditions with acetonitrile and ammonium acetate buffer as mobile phases. Popular commercially available Indian brand filtered and non-filtered cigarettes were analyzed using the same method. The identification of each chemical was established by chromatographic retention times, analyte specific fragmentation patterns and relative peak area ratios of two product/precursor ion pairs. The limit of detection of this method ranged from 1.74 to 14.32 ng/cig using an injection volume of 20 μl. The reproducibility of this method is excellent and better standard deviations were obtained compared to literature reported values for these chemicals. RSD value is less than 9% for all analytes.  相似文献   

15.
A method for preparation of a stationary phase-adjustable column with in-column stationary phase-coated fused-silica fiber annular column was successfully developed. The surface of a 0.12 mm o.d. bare optical fiber was first coated with a stationary phase and then inserted into a fused-silica capillary (non-coated or coated) as an annular column for gas chromatographic study. The optical fiber and capillary were coated with polydimethylsiloxane (SE-30) and polyethylene glycol 20M (PEG-20M) as nonpolar and polar stationary phases, respectively. Among the investigated annular and open tubular columns, the PEG-20M-coated fiber-in-PEG-20M-coated capillary annular column showed the highest column efficiency with a minimum plate height of 0.35 mm and an optimum gas velocity of 25 cm/s. When a SE-30/PEG-20M-coated fiber-in-uncoated capillary annular column was applied to separate a 9-component complex mixture, the total analysis time was 5.3 min and the column length was 12 m. By contrast, when a SE-30-coated fiber-in-PEG-20M-coated capillary annular column was used to separate the same 9-component mixture, the analysis time was reduced to 3.5 min and the column length was shortened by half to 6 m. Our results show that the stationary phase-coated fiber-in-stationary phase-coated capillary annular column is a better choice for gas chromatographic separation as it is more efficient and flexible. In addition, the proposed annular column design provides flexibility in using two or even more types of stationary phases to achieve optimal analytical separation.  相似文献   

16.
A continuous flow liquid membrane extraction (CFLME)-C18 precolumn-liquid chromatography system was developed for preconcentration and determination of chlorinated phenols (CPs). After preconcentration by CFLME, which is based on the combination of continuous flow liquid-liquid extraction and supported liquid membrane, CPs were enriched in 960 μl of 0.5 mol l−1 NaOH used as acceptor. This acceptor was on-line neutralized and transported onto the C18 precolumn where analytes were absorbed and focused. Then the focused analytes were injected onto the C18 analytical column for separation and detected at 215 nm with a diode array detector. CFLME related parameters such as flow rates, pH of donor and acceptor concentration were optimized. The proposed method presents detection limits of 0.02-0.09 μg l−1 (S/N=3) when 100 ml samples were enriched. The proposed method was successfully applied to determine CPs in tap water and river water samples with spiked recoveries in the range of 70-121%.  相似文献   

17.
In the Sequential Injection Chromatography (SIC) only monolithic columns for chromatographic separations have been used so far. This article presents the first use of fused-core particle packed column in an attempt to extend of the chromatographic capabilities of the SIC system. A new fused-core particle column (2.7 μm) Ascentis® Express C18 (Supelco™ Analytical) 30 mm × 4.6 mm brings high separation efficiency within flow rates and pressures comparable to monolithic column Chromolith® Performance RP-18e 100-3 (Merck®) 100 mm × 3 mm. Both columns matches the conditions of the commercially produced SIC system - SIChrom™ (8-port high-pressure selection valve and medium-pressure Sapphire™ syringe pump with 4 mL reservoir - maximal work pressure 1000 PSI) (FIAlab®, USA). The system was tested by the separation of four estrogens with similar structure and an internal standard - ethylparaben. The mobile phase composed of acetonitrile/water (40/60 (v/v)) was pumped isocratic at flow rate 0.48 mL min−1. Spectrophotometric detection was performed at wavelength of 225 nm and injected volume of sample solutions was 10 μL. The chromatographic characteristics of both columns were compared. Obtained results and conclusions have shown that both fused-core particle column and longer narrow shaped monolithic column bring benefits into the SIC method.  相似文献   

18.
A method for the rapid trace analysis of 24 residual pesticides in apple juice by multidimensional gas chromatography–mass spectrometry (MD-GC/MS) using dispersive liquid–liquid microextraction (DLLME) was developed and optimized. Several parameters of the extraction procedure such as type and volume of extraction solvent, type and volume of dispersive solvent and salt addition were evaluated to achieve the highest yield and to attain the lowest detection limits. The DLLME procedure optimized consists in the formation of a cloudy solution promoted by the fast addition to the sample (5 ml) of a mixture of carbon tetrachloride (extraction solvent, 100 μl) and acetone (dispersive solvent, 400 μl). The tiny droplets formed and dispersed among the aqueous sample solution are further joined and sedimented (85 μl) in the bottom of the conical test tube by centrifugation. Once extracted, all the 24 pesticides were directly injected and separated by a dual GC column system, comprising a short wide-bore DB-5 capillary column with low film thickness connected by a Deans switch system to a second chromatographic narrower column, with identical stationary phase. The instrumental setting used, in combination with carefully optimized operational fast GC and MS parameters, markedly decreased the retention times of the targeted analytes. The total chromatographic run was 8 min. Mean recoveries for apple juice spiked at three concentrations ranged from 60% to 105% and the intra-repeatability ranged from 1% to 21%. The limits of detection of the 24 pesticides ranged from 0.06 to 2.20 μg/L. In 2 of a total of 28 analysed samples were found residues of captan, although at levels below the maximum limit legal established.  相似文献   

19.
In this work, a method based on capillary electrophoresis with amperometric detection and far infrared-assisted extraction has been developed for the determination of rutin, gentisic acid, and quercetin in the leaves of Lycium barbarum Linn. The effects of detection potential, irradiation time, and the voltage applied on the infrared generator were investigated to acquire the optimum analysis conditions. The detection electrode was a 300-μm-diameter carbon disc electrode at a detection potential of +0.90 V. The three analytes could be well separated within 12 min in a 40 cm length fused-silica capillary at a separation voltage of 12 kV in a 50 mM borate buffer (pH 9.2). The relation between peak current and analyte concentration was linear over about 3 orders of magnitude with the detection limits (S/N = 3) of 0.31, 0.48, and 0.78 μM for rutin, gentisic acid, and quercetin, respectively. The proposed method has been applied to determine the three bioactive constituents in real plant samples.  相似文献   

20.
A new liquid chromatography–electrospray ionization mass spectrometry (LC–ESI-MS) method for the fast determination of phospholipase A2 (PLA2) activity has been developed. For the first time, the method allows the parallel detection of glycerophosphatidylcholine (GroPCho) as PLA2 substrate as well as of its products fatty acid (FA) and lyso-GroPCho. ESI-MS was carried out in negative ion mode, detecting the FA as [M − H] ions and the lyso-GroPCho and GroPCho as acetate adducts [M + Ac]. Utilizing a fast gradient on a short C5-modified silica gel column with 3 μm particles, five GroPChos, five FAs and six lyso-GroPChos could be separated according to their chain length in less than 3 min. A very high average chromatographic efficiency of 41,200 theoretical plates (plate height 0.5 μm) was achieved for the separation of the GroPChos. The method was applied for monitoring the release of arachidonic acid (20:4 FA) and 1-stearoyl-lyso-sn-GroPCho (18:0 GroPCho) from unilamellar vesicles of 1-stearoyl-2-arachidonoyl-sn-GroPCho (18:0/20:4 GroPCho). With a limit of detection of 0.5 pmol (total amount injected on column) for the FAs and lyso-GroPChos and 1.5 pmol for the GroPChos as well as a linear range of 1.5 decades, the method has proven to be suitable for the monitoring of different secretory PLA2 (sPLA2) conversions. Furthermore, it was applied to screen a small library of PLA2 inhibitors for their activity towards sPLA2 type V and snake venom of Bothrops moojeni. In both cases, active samples could be directly identified. With its short analysis time, its high chromatographic efficiency and the parallel detection of substrate and all products, the developed LC–ESI-MS method is well suited for the analysis of PLA2 activity.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号