首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Fabric phase sorptive extraction (FPSE) is a new, yet very promising member of the sorbent-based sorptive microextraction family. It has simultaneously improved both the extraction sensitivity and the speed of the extraction by incorporating high volume of sol–gel hybrid inorganic–organic sorbents into permeable fabric substrates. The advantages of FPSE have been investigated for the determination of four non-steroidal anti-inflammatory drugs, ibuprofen, naproxen, ketoprofen and diclofenac, in environmental water samples in combination with gas chromatography–mass spectrometry. Initially, the significance of several parameters affecting FPSE: sorbent chemistry, matrix pH and ionic strength were investigated using a mixed level factorial design (31 × 22). Then, other important parameters e.g., sample volume, extraction kinetics, desorption time and volume were also carefully studied and optimized. Due to the high sorbent loading on the FPSE substrate in the form of ultra-thin coating and the open geometry of the microextraction device, higher mass transfer of the target analytes occurs at a faster rate, leading to high enrichment factors in a relatively short period of time (equilibrium times: 45–100 min). Under optimal operational conditions, the limits of detection (S/N = 3) were found to be in the range of 0.8 ng L−1 to 5 ng L−1. The enrichment factors ranged from 162 to 418 with absolute extraction efficiencies varied from 27 to 70%, and a good trueness (82–116% relative recoveries) indicating that the proposed method can be readily deployed to routine environmental pollution monitoring. The proposed method was successfully applied to the analysis of target analytes in two influent and effluent samples from a wastewater treatment plant and two river water samples in Spain.  相似文献   

2.
In this work, we propose solvent-based de-emulsification dispersive liquid–liquid microextraction (SD-DLLME) as a simple, rapid and efficient sample pretreatment technique for the extraction and preconcentration of organochlorine pesticides (OCPs) from environmental water samples. Separation and analysis of fifteen OCPs was carried out by gas chromatography–mass spectrometry (GC/MS). Parameters affecting the extraction efficiency were systematically investigated. The detection limits were in the range of 2–50 ng L−1 using selective ion monitoring (SIM). The precision of the proposed method, expressed as relative standard deviation, varied between 3.5 and 10.2% (n = 5). Results from the analysis of spiked environmental water samples at the low-ppb level met the acceptance criteria set by the EPA.  相似文献   

3.
Dispersive liquid–liquid microextraction with little solvent consumption (DLLME-LSC), a novel dispersive liquid–liquid microextraction (DLLME) technique with few solvent requirements (13 μL of a binary mixture of disperser solvent and extraction solvent in the ratio of 6:4) and short extraction time (90 s), has been developed for extraction of organochlorine pesticides (OCPs) from water samples prior to gas chromatography/mass spectrometry analysis. In DLLME-LSC, much less volume of organic solvent is used as compared to DLLME. The new technique is less harmful to environment and yields a higher enrichment factor (1885–2648-fold in this study). Fine organic droplets were formed in the sample solution by manually shaking the test tube containing the mixture of sample solution and extraction solvent. The large surface area of the organic solvent droplets increases the rate of mass transfer from the water sample to the extractant and produces efficient extraction in a short period of time. DLLME-LSC shows good repeatability (RSD: 4.1–9.7% for reservoir water; 5.6–8.9% for river water) and high sensitivity (limits of detection: 0.8–2.5 ng/L for reservoir water; 0.4–1.3 ng/L for river water). The method can be used on various water samples (river water, tap water, sea water and reservoir water). It can be used for routine work for the investigation of OCPs.  相似文献   

4.
A novel liquid–liquid–solid microextraction (LLSME) technique based on porous membrane-protected molecularly imprinted polymer (MIP)-coated silica fiber has been developed. In this technique, a MIP-coated silica fiber was protected with a length of porous polypropylene hollow fiber membrane which was filled with water-immiscible organic phase. Subsequently the whole device was immersed into aqueous sample for extraction. The LLSME technique was a three-phase microextraction approach. The target analytes were firstly extracted from the aqueous sample through a few microliters of organic phase residing in the pores and lumen of the membrane, and were then finally extracted onto the MIP fiber. A terbutylazine MIP-coated silica fiber was adopted as an example to demonstrate the feasibility of the novel LLSME method. The extraction parameters such as the organic solvent, extraction and desorption time were investigated. Comparison of the LLSME technique was made with molecularly imprinted polymer based solid-phase microextraction (MIP-SPME) and hollow fiber membrane-based liquid-phase microextraction (HF-LPME), respectively. The LLSME, integrating the advantages of high selectivity of MIP-SPME and enrichment and sample cleanup capability of the HF-LPME into a single device, is a promising sample preparation method for complex samples. Moreover, the new technique overcomes the problem of disturbance from water when the MIP-SPME fiber was exposed directly to aqueous samples. Applications to analysis of triazine herbicides in sludge water, watermelon, milk and urine samples were evaluated to access the real sample application of the LLSME method by coupling with high-performance liquid chromatography (HPLC). Low limits of detection (0.006–0.02 μg L−1), satisfactory recoveries and good repeatability for real sample (RSD 1.2–9.6%, n = 5) were obtained. The method was demonstrated to be a fast, selective and sensitive pretreatment method for trace analysis of triazines in complex aqueous samples.  相似文献   

5.
Recently, multi-wall carbon nanotubes (MWCNTs) as adsorbents of solid-phase extraction are attractive because they can be used for enrichment of organic compounds and metal ions at trace levels. In this study, we use the carboxyl modified multi-wall carbon nanotubes (CMMWCNTs) as adsorbents of solid-phase extraction for extraction of linear alkylbenzene sulfonates (LAS), which are widely used anion surfactant with different homologues, and detected by HPLC-UV. The effect of eluent and its volume, sample pH and flow rate, sample volume and the ultrasonic time of sample, the content of the electrolyte (NaCl) were investigated and optimized. The detection limit for LAS homologues was 0.02-0.03 μg L−1 with R.S.D. (n = 6) ranging from 2.04 to 10.03%. The recoveries of LAS homologues in the spiked environmental water samples ranged from 84.8 to 106.1%. The proposed method has been applied successfully to the analysis of LAS in aqueous environmental samples, which demonstrates that CMMWCNTs-based solid-phase extraction is a precision and convenient enrichment method and can be used for analysis of LAS homologues in water samples.  相似文献   

6.
To assess the potential risks associated with the environmental exposure of β-lactam antibiotics (BLAs), the monitoring of the occurrence, distribution, and fate of these emerging contaminants in the environment is required. Herein, we demonstrate a molecularly imprinted solid-phase extraction (MISPE) method for selective and reliable screening of trace BLAs in river and tap water. By developing a low-temperature photopolymerization, highly selective molecularly imprinted polymers (MIPs) for five BLAs (penicillin G, amoxicillin, ampicillin, nafcillin and mezlocillin) were synthesized. Nafcillin was chosen as a pseudo template to make the MIP sorbent (Nafc-MIP), which was used in pseudo-template MISPE for preconcentration of the other four BLAs from river and tap water. The application of pseudo-template MISPE overcomes the template bleeding, which significantly elevates the sample background and restricts the application of MIP for detection of the target BLA below 2 μg/L. The average recoveries of BLAs are in the range of 60–90% when Nafc-MIP was adopted as the selective MISPE sorbent. The developed method was validated, and applied to the screening of trace β-lactam antibiotics in river and tap water. The linearity of the calibration curve for each BLA was observed over the range of 0.1–20 μg/L (r > 0.998). The β-lactam antibiotics were found within the range of 0–9.56 μg/L in river water at the downstream of antibiotics manufacturers, and none were detected in the tap water.  相似文献   

7.
By using ionic liquid as membrane liquid and tri-n-octylphosphine oxide (TOPO) as additive, hollow fiber supported liquid phase microextraction (HF-LPME) was developed for the determination of five sulfonamides in environmental water samples by high-performance liquid chromatography with ultraviolet detection The extraction solvent and the parameters affecting the extraction enrichment factor such as the type and amount of carrier, pH and volume ratio of donor phase and acceptor phase, extraction time, salt-out effect and matrix effect were optimized. Under the optimal extraction conditions (organic liquid membrane phase: [C8MIM][PF6] with 14% TOPO (w/v); donor phase: 4 mL, pH 4.5 KH2PO4 with 2 M Na2SO4; acceptor phase: 25 μL, pH 13 NaOH; extraction time: 8 h), low detection limits (0.1–0.4 μg/L, RSD ≤ 5%) and good linear range (1–2000 ng/mL, R2 ≥ 0.999) were obtained for all the analytes. The presence of humic acid (0–25 mg/L dissolved organic carbon) and bovine serum albumin (0–100 μg/mL) had no significant effect on the extraction efficiency. Good spike recoveries over the range of 82.2–103.2% were obtained when applying the proposed method on five real environmental water samples. These results indicated that this present method was very sensitive and reliable with good repeatabilities and excellent clean-up in water samples. The proposed method confirmed hollow fiber supported ionic liquid membrane based LPME to be robust to monitoring trace levels of sulfadiazine, sulfamerazine, sulfamethazine, sulfadimethoxine and sulfamethoxazole in aqueous samples.  相似文献   

8.
A solid-phase extraction (SPE) using multi-walled carbon nanotubes (MWCNTs) as adsorbent coupled with gas chromatography–mass spectrometry (GC–MS) method was developed for the determination of 16 polycyclic aromatic hydrocarbons (PAHs) in environmental water samples. Several condition parameters, such as extraction adsorbents, elution solvents and volumes, and sample loading flow rate and volume were optimized to obtain high SPE recoveries and extraction efficiency. 150 mg MWCNTs as sorbent presented high extraction efficiency of 16 PAHs due to the large specific surface area and high adsorption capacity of MWCNTs compared with the commercial C18 column (250 mg/2 mL). The calibration curves of 16 PAHs extracted were linear in the range of 20–5000 ng L−1, with the correlation coefficients (r2) between 0.9848 and 0.9991. The method attained good precisions (relative standard deviation, RSD) from 1.2% to 12.1% for standard PAHs aqueous solutions; method recoveries ranged in 76.0–125.5%, 74.5–127.0%, and 70.0–122.0% for real spiked samples from river water, tap water and seawater, respectively. Limits of detection (LODs, S/N = 3) of the method were determined from 2.0 to 8.5 ng L−1. The optimized method was successfully applied to the determination of 16 PAHs in real environmental water samples.  相似文献   

9.
Graphene is a good adsorbent for organic pollutants, especially for compounds containing benzene rings. When used in TiO2 nanotube arrays for micro-solid phase extraction (μ-SPE), the combination of graphene’s strong adsorptive properties with its good separation capabilities results in excellent sample preconcentration performance. In the present study, graphene-modified TiO2 nanotube arrays were prepared by electrodeposition using a cyclic voltammetric reduction method. Four carbamate pesticides, including metolcarb, carbaryl, isoprocarb, and diethofencarb, were used as model analytes to validate the enrichment properties of the prepared adsorbent in μ-SPE. Factors affecting the enrichment efficiency of the μ-SPE procedure were optimized and included sample pH, elution solvents, salting-out effect, adsorption time and desorption time. Under optimal conditions, graphene-modified TiO2 nanotube arrays exhibited excellent enrichment efficiency for carbamate pesticides. The detection limits of these carbamate pesticides ranged from 2.27 to 3.26 μg L−1. The proposed method was validated using four environmental water samples, and yields of pesticides recovered from spiked test samples of the four analytes were in the range of 83.9–108.8%. These results indicate that graphene-modified TiO2 nanotube arrays exhibit good adsorption to the target pollutants, and the method described in this work could be used as a faster and easier alternative procedure for routine analysis of carbamate pesticides in real water samples.  相似文献   

10.
Yongjiang Zhang  Lu Li  Jia Cao 《Talanta》2010,80(5):1907-57
The eggshell membrane (ESM) contains several surface functional groups such as amines, amides and carboxylic groups with potential as SPE adsorbent for the retention of target species of interest. In this paper, the potential use of ESM, a typical biomaterial, as solid-phase extraction (SPE) adsorbent is evaluated for analysis of trace arsenic(V) in environmental water samples in combination with hydride generation atomic fluorescence spectrometry (HG-AFS). In order to obtain the satisfactory recovery of arsenic(V), various parameters including the desorption and enrichment conditions such as pH, the flow rate and the volume of sample solution, the amount of ESM and the content of sodium chloride were systematically optimized and the effects of co-existed ions were also investigated in detail. Under the optimal conditions, arsenic(V) could be easily extracted by the ESM packed cartridge and the breakthrough adsorption capacity was found to be 3.9 μg g−1. The favorable limit of detection (LOD) for arsenic(V) was found to be 0.001 μg L−1 with an enrichment factor of 33.3, and the relative standard deviations (R.S.Ds) was 2.1% for 0.6 μg L−1 arsenic (n = 11). The reproducibility among columns was satisfactory (R.S.D. among columns is less than 5%). The proposed method has been successfully applied to analysis of arsenic(V) in aqueous environmental samples, which suggests the ESM can be an excellent SPE adsorbent for arsenic(V) pretreatment and enrichment from real water samples.  相似文献   

11.
In this work, a headspace-solid-phase micro-extraction (HS-SPME) combined with gas chromatography–mass spectrometry (GC–MS) method for multielemental speciation of organometallic compounds of mercury, lead and tin in water samples was upgraded by the introduction of tandem mass spectrometry (MS/MS) as detection technique. The analytical method is based on the ethylation with NaBEt4 and simultaneous headspace-solid-phase micro-extraction of the derivative compounds followed by GC–MS/MS analysis. The main experimental parameters influencing the extraction efficiency such as derivatisation time, extraction time and extraction temperature were optimized. The overall optimum extraction conditions were the following: a 50 μm/30 μm divinyl-benzene/carboxen/polydimethylsiloxane (DVB/CAR/PDMS) SPME fibre, 150 min derivatisation time, 15 min extraction time, sample agitation at 250 rpm and 40 °C extraction temperature. The analytical characteristics of the HS-SPME method combined with GC–MS and GC–MS/MS were evaluated. The combination of both techniques HS-SPME and GC–MS/MS allowed to attain lower limits of detection (4–33 ng l−1) than those obtained by HS-SPME–GC–MS (17–45 ng l−1). The proposed method presented good linear regression coefficients (r2 > 0.9970) and repeatability (4.8–21.0%) for all the compounds under study. The accuracy of the method measured as the average percentage recovery of the compounds in spiked river water and seawater samples was higher than 80% for all the compounds studied, except for monobutyltin in the river water sample. A study of the uncertainty associated with the analytical results was also carried out.  相似文献   

12.
A procedure involving the simultaneous performance of liquid–liquid microextraction and polypropylene microporous membrane solid-phase extraction was carried out. The applicability of the proposed procedure was evaluated through extraction of several organochlorine pesticides from river water, tomato and strawberry samples. The parameters affecting the extraction efficiency were optimized by multivariable designs, and the analytical features were estimated. Under optimized conditions, analytes were concentrated onto 1.5 cm long microporous membranes placed directly into the sample containing 15 mL of water with 20 μL of 1-octanol. The best extraction conditions were achieved at 59 °C, with 60 min of extraction time and 2.91 g of sodium chloride. The desorption of the analytes was carried out using 30 μL of a mixture of toluene and hexane in the proportion of 60:40% (v/v) for 10 min. Detection limits in the range of 2.7–20.0 ng L−1, 0.50–1.15 μg kg−1, and 1.53–12.77 μg kg−1 were obtained for river water, strawberry and tomato samples, respectively. Good repeatability was obtained for all three sample types. The results suggest that the proposed procedure represents a very simple and low-cost microextraction alternative rendering adequate limits of quantification for the determination of organochlorine pesticides in environmental and food samples.  相似文献   

13.
The paper described a new ionic liquid, 1,3-dibutylimidazolium hexafluorophosphate, as extraction solvent for extraction and preconcentration of organophosphorus pesticides (fenitrothion, parathion, fenthion and phoxim) from water and fruit samples by dispersive liquid–liquid microextraction combined with high-performance liquid chromatography. The effects of experimental parameters, such as extraction solvent volume, disperser solvent and its volume, extraction and centrifugal time, sample pH, extraction temperature and salt addition, on the extraction efficiency were investigated. An extraction recovery of over 75% and enrichment factor of over 300-fold were obtained under the optimum conditions. The linearity relationship was also observed in the range of 5–1000 μg L−1 with the correlation coefficients (r2) ranging from 0.9988 to 0.9999. Limits of detection were 0.01–0.05 μg L−1 for four analytes. The relative standard deviations at spiking three different concentration levels of 20, 100 and 500 μg L−1 varied from 1.3–2.7, 1.4–1.9 and 1.1–1.7% (n = 7), respectively. Three real samples including tap water, Yellow River water and pear spiked at three concentration levels were analyzed and yielded recoveries ranging from 92.7–109.1, 95.0–108.2 and 91.2–108.1%, respectively.  相似文献   

14.
Present study developed a new method for the sensitive determination of pyrethroid insecticides with solid phase extraction in combination with high performance liquid chromatography and UV detector. SiO2 microspheres, a new SiO2 based material, was investigated for the enrichment ability and applicability as the solid phase extraction sorbent. Four pyrethroid pesticides such as fenpropathrin, cyhalothrin, fenvalevate and biphenthrin were used as the target analytes. Parameters that maybe influence the extraction efficiency such as the eluent type and its volume, sample flow rate, sample pH, and the sample volume were optimized in detail, and the optimal conditions were as followed: sample volume, 100 mL; concentration of methanol, 30%; acetone volume, 5 mL; sample flow rate, 4.2 mL min−1; sample pH, 7. The experimental results indicated that there was good linearity in the concentration range of 0.1–50 μg L−1 except biphenthrin in the range of 0.05–25 μg L−1. The detection limits for fenpropathrin, cyhalothrin, fenvalevate and biphenthrin were in the range of 0.02–0.08 μg L−1. The intra-day and day to day precisions (RSDs, n = 6) were in the ranges of 2.6–4.4% and 5.3–7.2%, respectively. The method was validated with five real environmental water samples, and all these results proved that proposed method could be used as a good alternative for the routine analysis for such pollutants in environmental samples.  相似文献   

15.
A sensitive and reliable method using capillary HPLC with UV-diode array detection (DAD) has been developed and validated for the trace determination of residues of 10 β-lactam antibiotics of human and veterinary use, in milk, chicken meat and environmental water samples. The analytes included ampicillin, amoxicillin, penicillin V, penicillin G, cloxacillin, oxacillin, dicloxacillin, nafcillin, piperacillin and clavulanic acid. Legal levels are regulated by the EU Council regulation 2377/90 in animal edible tissues for these compounds. For food analysis, a solid-phase extraction (SPE) procedure consisting in a tandem of Oasis HLB and Alumina N cartridges was applied for off-line preconcentration and cleanup. For water analysis, the first step was only necessary. The limits of detection for the studied compounds were between 0.04–0.06 μg l−1 for water samples and 0.80–1.40 μg l−1 (or μg kg−1) in the case of foods derived from animals. Average recoveries for fortified samples at different concentration levels ranged between 82.9% and 98.2%, with relative standard deviations (RSDs) lower than 9%. The method showed the advantages of capillary HPLC for the detection of these widely applied antibiotics in different samples at very low concentration levels.  相似文献   

16.
In this work, a rapid, simple and efficient homogeneous liquid–liquid microextraction via flotation assistance (HLLME-FA) method was developed based on applying low density organic solvents without no centrifugation. For the first time, a special extraction cell was designed to facilitate collection of the low-density solvent extraction in the determination of four polycyclic aromatic hydrocarbons (PAHs) in water samples followed by gas chromatography-flame ionization detector (GC-FID). The effect of different variables on the extraction efficiency was studied simultaneously using experimental design. The variables of interest in the HLLME-FA were selected as extraction and homogeneous solvent volumes, ionic strength and extraction time. Response surface methodology (RSM) was applied to investigate the optimum conditions of all the variables. Using optimized variables in the extraction process, for all target PAHs, the detection limits, the precisions and the linearity of the method were found in the range of 14–41 μg L−1, 3.7–10.3% (RSD, n = 3) and 50–1000 μg L−1, respectively. The proposed method has been successfully applied to the analysis of four target PAHs in the water samples, and satisfactory results were obtained.  相似文献   

17.
A novel multi-templates molecularly imprinted polymer (MIP), using acidic pharmaceuticals mixture (ibuprofen (IBP), naproxen (NPX), ketoprofen (KEP), diclofenac (DFC), and clofibric acid (CA)) as the template, was prepared as solid-phase extraction (SPE) material for the quantitative enrichment of acidic pharmaceuticals in environmental samples and off-line coupled with liquid chromatography–mass spectrometry (LC/MS/MS). Washing solvent was optimized in terms of kind and volume for removing the matrix constituents nonspecifically adsorbed on the MIP. When 1 L of water sample spiked at 1 μg/L was loaded onto the cartridge, the binding capacity of the MIP cartridge were 48.7 μg/g for KEP, 60.7 μg/g for NPX, 52 μg/g for CA, 61.3 μg/g for DFC and 60.7 μg/g for IBP, respectively, which are higher than those of the commercial single template MIP in organic medium (e.g. toluene) reported in the literature. Recoveries of the five acidic pharmaceuticals extracted from 1 L of real water samples such as lake water and wastewater spiked at 1 μg/L were more than 95%. The recoveries of acidic pharmaceuticals extracted from 10-g sediment sample spiked at the 10 ng/g level were in the range of 77.4–90.6%. To demonstrate the potential of the MIP obtained, a comparison with commercial C18 SPE cartridge was performed. Molecularly imprinted solid-phase extraction (MISPE) cartridge showed higher recoveries than commercial C18 SPE cartridge for acidic pharmaceuticals. These results showed the suitability of the MISPE method for the selective extraction of a group of structurally related compounds such as acidic pharmaceuticals.  相似文献   

18.
In this study, an electrochemically enhanced solid-phase microextraction (EE-SPME) approach based on molecularly imprinted polypyrrole/multi-walled carbon nanotubes (MIPPy/MWCNTs) composite coating on Pt wire was developed for selective extraction of fluoroquinolone antibiotics (FQs) in aqueous samples. During the extraction, a direct current potential was applied to the MIPPy/MWCNTs/Pt fiber as working electrode in a standard three-electrode system, FQ ions suffered electrophoretic transfer to the coating surface and then entered into the shape-complimentary cavities by hydrogen-bonding and ion-exchange interactions. After EE-SPME extraction, the fiber was desorbed with desorption solvent for high-performance liquid chromatography (HPLC) analysis. Some parameters influencing EE-SPME extraction such as applied potential, extraction time, solution pH, ionic strength, and desorption solvent were optimized. EE-SPME showed good selectivity and higher extraction efficiency to FQs compared with that of traditional solid-phase microextraction. EE-SPME coupled with HPLC to determine FQs in water samples, the limits of detection (S/N = 3) for the selected FQs are 0.5–1.9 μg L−1. The proposed method was successfully used to the analysis of FQs spiked urine and soil samples, with recoveries of 85.1–94.2% for the urine samples and 89.8–95.5% for the soil samples.  相似文献   

19.
A method for the determination of 11 UV-filter compounds in sludge has been developed and evaluated. The procedure includes the use of non-porous polymeric membranes in combination with pressurised liquid extraction (PLE). Firstly, the solid sample, wetted with the extraction solvent, was enclosed into tailor-made bags prepared with low density polyethylene. Secondly, these packages were submitted to a conventional PLE (70 °C, 4 cycles of 5 min static time). Finally, the analytes were determined by liquid chromatography–atmospheric pressure photoionisation–tandem mass spectrometry. The main advantage of this procedure is the reduction of time, solvent and labour effort ought to the combination of extraction and clean-up in a single step. Although the extraction is not quantitative (thus, standard addition is recommended for quantification) selectivity is clearly gained using the membrane as a consequence of the differences of permeation and transport through the membrane between the analytes and other sample matrix components. The optimised protocol provides limits of detection ranging from 0.3 ng g−1 (ethylhexyl dimethyl p-aminobenzoate (OD-PABA)) to 25 ng g−1 (ethylhexyl triazone (EHT)) with only 0.5 g of sludge sample. All the studied UV filters were found in the samples at concentration levels between 1.4 and 2479 ng g−1, emphasising the high adsorption potential of this kind of environmental pollutants onto solid samples such as sludge. Also, this method has permitted the determination of seven of the studied UV filters in sludge samples for the first time.  相似文献   

20.
In this paper, bamboo charcoals were modified using Fe3O4 nanosheets for the first time. The composites, as a novel solid-phase microextraction (SPME) fiber coating, were used for the extraction of seven polybrominated diphenyl ethers (PBDEs) in environmental water samples. The extraction factors (stirring rate, extraction time, and ionic strength) and desorption factors (desorption time and desorption temperature) of the fibers were systematically investigated and optimized. Under optimum conditions, the linear range was 1–1000 ng L−1. Based on the ratio of chromatographic signal to base line noise (S N−1 = 3), the limits of detection (LODs) can reach 0.25–0.62 ng L−1. The novel method was successful in the analysis of PBDEs in real environmental water samples. The results indicate that bamboo charcoal/Fe3O4 as an SPME coating material coupled with gas chromatography–negative chemical ionization-mass spectrometry is an excellent method for the routine analysis of PBDEs at trace levels in environmental water samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号