首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
A novel selectable one-dimensional (1D) or two-dimensional (2D) gas chromatography–mass spectrometry (selectable 1D/2D GC–MS) system with selective detection was developed by using capillary flow technology and low thermal mass GC (LTM-GC). The main advantages of this system are the simple and fast selection of 1D GC–MS or 2D GC–MS operation without any instrumental set-up change (e.g.2D GC–MS can be run just after 1D GC–MS run), and simultaneous mass spectrometric and olfactometry or element-specific detection for both 1D and 2D separation to assure selection of a heart-cut region and correct identification of compounds of interest. The feasibility and benefit of the proposed system with selective detection, e.g. olfactometry, nitrogen phosphorus detection (NPD), and pulsed flame photometric detection (PFPD), was demonstrated with an identification of trace amounts of aroma components in beverages (beer and coffee). Using stir bar sorptive extraction (SBSE) and selectable 1D/2D GC–Olfactometry/MS on a beer sample, β-damascenone could be determined at 1.9 ng mL−1 (RSD 3.1%, n = 6) as a potent aroma compound. In a coffee sample, two odor active compounds were clearly resolved from a 4.2 s heart-cut and were assigned probable identifications as 4,5-dimethyl thiazole and dimethyl trisulfide based on a NIST library search, dual linear retention indices (dual LRI) and elemental information obtained by SBSE in combination with selectable 1D/2D GC–NPD/PFPD/MS.  相似文献   

2.
A method for the rapid simultaneous screening and identification of multiple pesticide residues in vegetables was established using a novel database and gas chromatography in combination with hybrid quadrupole time-of-flight mass spectrometry (GC–QTOF MS). A total of 187 pesticides with different chemical species were measured by GC–QTOF MS to create the database, which collected the retention time and exact masses of ions from the first-stage mass spectrum (MS1 spectrum) and second-stage mass spectrum (MS2 spectrum) for each pesticide. The workflow of the created database consisted of “MS1 screening” for possible pesticides by chemical formula match and “MS2 identification” for structural confirmation of product ion by accurate mass measurement. To evaluate the applicability of the database, a spinach matrix was prepared by solid phase extraction, spiked with a mixture of 50 pesticides at seven concentrations between 0.1 and 10 ppb, and analyzed by GC–QTOF MS. It was found that all of the 50 pesticides with concentrations as low as 5 ppb were detected in the “MS1 screening” step and accurate masses were identified with errors less than 2.5 mDa in the “MS2 identification” step, indicating high sensitivity, accuracy, selectivity and specificity. Finally, to validate the applicability, the new method was applied to four fresh celery, rape, scallion and spinach vegetables from a local market. As a result, a total of 13 pesticides were found, with 11 in celery, 9 in rape, 3 in scallion and 2 in spinach. In conclusion, GC–QTOF MS combined with an exact mass database is one of the most efficient tools for the analysis of pesticide residues in vegetables.  相似文献   

3.
In this work, a headspace-solid-phase micro-extraction (HS-SPME) combined with gas chromatography–mass spectrometry (GC–MS) method for multielemental speciation of organometallic compounds of mercury, lead and tin in water samples was upgraded by the introduction of tandem mass spectrometry (MS/MS) as detection technique. The analytical method is based on the ethylation with NaBEt4 and simultaneous headspace-solid-phase micro-extraction of the derivative compounds followed by GC–MS/MS analysis. The main experimental parameters influencing the extraction efficiency such as derivatisation time, extraction time and extraction temperature were optimized. The overall optimum extraction conditions were the following: a 50 μm/30 μm divinyl-benzene/carboxen/polydimethylsiloxane (DVB/CAR/PDMS) SPME fibre, 150 min derivatisation time, 15 min extraction time, sample agitation at 250 rpm and 40 °C extraction temperature. The analytical characteristics of the HS-SPME method combined with GC–MS and GC–MS/MS were evaluated. The combination of both techniques HS-SPME and GC–MS/MS allowed to attain lower limits of detection (4–33 ng l−1) than those obtained by HS-SPME–GC–MS (17–45 ng l−1). The proposed method presented good linear regression coefficients (r2 > 0.9970) and repeatability (4.8–21.0%) for all the compounds under study. The accuracy of the method measured as the average percentage recovery of the compounds in spiked river water and seawater samples was higher than 80% for all the compounds studied, except for monobutyltin in the river water sample. A study of the uncertainty associated with the analytical results was also carried out.  相似文献   

4.
An acetonitrile-based extraction method for the analysis of 169 pesticides in soya grain, using liquid chromatography–tandem mass spectrometry (LC–MS/MS) in the positive and negative electrospray ionization (ESI) mode, has been optimized and validated. This method has been compared with our earlier published acetone-based extraction method, as part of a comprehensive study of both extraction methods, in combination with various gas chromatography–(tandem) mass spectrometry [GC–MS(/MS)] and LC–MS/MS techniques, using different detection modes. Linearity of calibration curves, instrument limits of detection (LODs) and matrix effects were evaluated by preparing standards in solvent and in the two soya matrix extracts from acetone and acetonitrile extractions, at seven levels, with six replicate injections per level. Limits of detection were calculated based on practically realized repeatability relative standard deviations (RSDs), rather than based on (extrapolated) signal/noise ratios. Accuracies (as % recoveries), precision (as repeatability of recovery experiments) and method limits of quantification (LOQs) were compared. The acetonitrile method consists of the extraction of a 2-g sample with 20 mL of acetonitrile (containing 1% acetic acid), followed by a partitioning step with magnesium sulphate and a subsequent buffering step with sodium acetate. After mixing an aliquot with methanol, the extract can be injected directly into the LC–MS/MS system, without any cleanup. Cleanup hardly improved selectivity and appeared to have minor changes of the matrix effect, as was earlier noticed for the acetone method. Good linearity of the calibration curves was obtained over the range from 0.1 or 0.25 to 10 ng mL−1, with r2 ≥ 0.99. Instrument LOD values generally varied from 0.1 to 0.25 ng mL−1, for both methods. Matrix effects were not significant or negligible for nearly all pesticides. Recoveries were in the range 70–120%, with RSD ≤ 20%. If not, they were still mostly in the 50–70% range, with good precision (RSD ≤ 20%). The method LOQ values were most often 10 μg kg−1 for almost all pesticides, with good repeatability RSDs. Apart from some minor pros and cons, both compared methods are fast, efficient and robust, with good method performances. The two methods were applied successfully in a routine analysis environment, during surveys in 2007 and 2008.  相似文献   

5.
In this study, a new modulator that is simple, robust and presents low operation costs, was developed. This modulator uses compressed air to cool two small portions in the first centimeters of the second chromatographic column of a comprehensive multidimensional gas chromatography (GC × GC) system. The results show a variation in the peak area less than 3 and 5% to alkanes and pesticides, respectively. The standard deviations for the retention times in the first and second dimension are around 0.05 min and 0.05 s for all the compounds. The system was optimized with n-alkanes. The GC × GC system proposed was applied in the determination of pyrethroid pesticides (bifenthrin, cypermethrin, deltamethrin, fenvalerate, esfenvalerate, cis- and trans-permethrin) in grape samples. Samples were extracted by the mini-Luke modified method and pesticides were quantified by comprehensive multidimensional gas chromatography with micro electron-capture detection (μECD). The values of method limit of quantification (LOQ) were 0.01–0.02 mg kg−1 for all studied pyrethroid and the values of recovery were between 94.3 and 115.2%, with good precision (RSD < 18.4%), demonstrating that the performance of the total method consisting of a modified Luke extraction method and determination by GC × GC-μECD are satisfactory. This study also showed that the system using a modulator with a double jet of compressed air has the potential for application in the analysis of a wider range of pesticide residues in other commodities since it provides low values of LOQ with acceptable accuracy and precision.  相似文献   

6.
An optimized analytical method employing gas chromatography–tandem quadrupole mass spectrometry (GC–MS/MS) has been developed for the simultaneous screening of roughly 150 pesticides in honeybees suspected of poisoning by pesticides during field spraying. In this work, a sample preparation approach based on acetonitrile extraction followed by dispersive solid-phase extraction (d-SPE) cleanup was implemented and validated for pesticides in honeybees for the first time. The procedure involved homogenization of a 2 g sample (23 insects on average) with acetonitrile–water mixture followed by salting out with citrate buffer, magnesium sulphate and sodium chloride. An amount of matrix constituents with limited solubility in acetonitrile was reduced in the extract by precipitation at low-temperature (freezing-out cleanup). Hereafter, d-SPE cleanup was carried out using primary secondary amine (PSA), octadecyl (C18) and graphitized carbon black (GCB). This combination of cleanup steps ensured efficient extract purification. Linearity of the calibration curves was studied using matrix-matched standards in the concentration range between 4 and 500 ng mL−1 (equivalent to 10 and 1250 ng g−1), and coefficients of determination (R2) were ≥0.99 for approximately 90% of the targeted compounds. The recovery data were obtained by spiking honeybees samples free of pesticides at three concentration levels of 10, 50, and 500 ng g−1 (approximately 0.9, 4.3, 43.5 ng per bee). At these spiking levels 47, 77 and 92% of the targeted compounds were recovered, respectively. Generally the recoveries were in the range between 70 and 120% with precision values, expressed as relative standard deviation (RSD) ≤ 20%. The expanded uncertainty was estimated following a “top down” empirical model as being 28% on average (coverage factor k = 2, confidence level 95%). Preliminary results from practical application to analysis of real samples are presented. A total of 25 samples of honeybees from suspected pesticides poisoning incidents were analyzed, in which 10 different pesticides were determined.  相似文献   

7.
Polybrominated diphenyl ethers (PBDEs) are a class of flame retardants used globally in many consumer products and industrial applications. Traditionally, gas chromatography–high resolution mass spectrometry (GC–HR-MS) is the method of choice for analysis of PBDEs in environmental samples because it offers high sensitivity and selectivity, resulting in less interferences. However, the specificity offered by gas chromatography-triple quadrupole tandem mass spectrometry (GC–QQQ-MS/MS), operated in selected reaction monitoring mode, provides a more affordable alternative to GC–HR-MS for the analysis of PBDEs in complex environmental samples. In this study, an analytical method was developed for the analysis of 41 PBDE congeners in fish using GC–QQQ-MS/MS. Results from the analysis of three fish species [lake trout (Salvelinus namaycush), yellow perch (Perca flavescens), and round goby (Neogobius melanostomus)] using GC–QQQ-MS/MS were compared with those obtained by GC–HR-MS. These species were selected because they represent varying levels of lipid-rich matrix and contaminant loads. Instrumental limits of detection for the GC–QQQ-MS/MS ranged from 0.04 pg to 41 pg, whereas those for the GC–HR-MS ranged from 5 pg to 85 pg. The PBDE values obtained from these two methods were highly correlated, R2 values >0.7, for all three fish species, supporting the suitability of GC–QQQ-MS/MS for analysis of PBDEs in fish with varying fat content.  相似文献   

8.
A novel and highly selective method has been developed for the determination of aromatic primary amines by their conversion to dithiocarbamates by reaction with carbon disulphide, and then to isothiocyanates, which are volatile, by heating in the presence of a heavy metal ion. Zinc(II) was selected owing to its low toxicity and optimum yield of isothiocyanates. The latter were sampled by headspace-solid phase microextraction (HS-SPME) on divinylbenzene-carboxen-polydimethylsiloxane fibre, 50/30 μm. The HS-SPME procedure was optimized to provide adequate limits of detection in the analysis of aromatic amines in their real samples by gas chromatography with mass spectrometry (GC–MS) or flame ionization detection (GC–FID). The method gave rectilinear calibration graph, correlation coefficient and limit of detection, respectively, over the range 0.08–100 μg L−1, 0.9950–0.9990 and 25–240 ng L−1 in gas chromatography–mass spectrometry, and 0.01–10 mg L−1, 0.9910–0.9991 and 0.8–3.0 μg L−1 in gas chromatography–flame ionization detection. At two different levels, 10 and 40 μg L−1, the range of intra-day RSD was 3.7–8.5% (GC–MS) and 3.3–9.2% (GC–FID), respectively. The proposed method is simple and rapid, and has been applied to determine aromatic primary amines in the environmental waters, food samples of ice cream powder and soft drinks concentrate, and food colours. The intra-day RSD in the analysis of real samples by GC–MS was in the range 3.6–6.2%. The food/colour samples were found to contain elevated levels of aniline and 2-toluidine.  相似文献   

9.
Comprehensive two-dimensional gas chromatography coupled to mass spectrometry (GC × GC–MS) is a powerful tool for comprehensive analysis of organic pollutants. In this study, we developed a powerful analytical method using GC × GC for rapid and accurate identification and quantification of compounds in environmental samples with complex matrices. Specifically, we have developed an automatic peak sentinel tool, T-SEN, with free programming software, R. The tool, which consists of a simple algorithm for on peak finding and peak shape identification, allows rapid screening of target compounds, even for large data sets from GC × GC coupled to high resolution time of flight mass spectrometry (HRTOFMS). The software tool automatically assigns and quantifies compounds that are listed in user databases. T-SEN works on a typical 64 bit workstation, and the reference calculation speed is 10–20 min for approximately 170 compounds for peak finding (five ion count setting) and integration from 1–2 GB of sample data acquired by GC × GC–HRTOFMS. We analyzed and quantified 17 PCDD/F congeners and 24 PCB congeners in a crude lake sediment extract by both GC × GC coupled to quadrupole mass spectrometry (qMS) and GC × GC–HRTOFMS with T-SEN. While GC × GC–qMS with T-SEN resulted in false identification and inaccurate quantification, GC × GC–HRTOFMS with T-SEN provided correct identification and accurate quantification of compounds without sample pre-treatment. The differences between the values measured by GC × GC–HRTOFMS with T-SEN and the certified values for the certified reference material ranged from 7.3 to 36.9% for compounds with concentrations above the limit of quantification. False positives/negatives were not observed, except for when co-elution occurred. The technique of GC × GC–HRTOFMS in combination with T-SEN provides rapid and accurate screening and represents a powerful new approach for comprehensive analysis.  相似文献   

10.
In this study we developed a GC–MS method for the analysis of priority pollutants, personal care products (PCPs) and other emerging contaminants in waters using large volume injection with backflushing. Analyses are performed in the SIM/scan mode, so that in addition to the targeted organic contaminants, this method allows the simultaneous screening of non-target compounds. The scan data are analysed using Deconvolution Reporting Software (DRS) which screens the results for 934 organic contaminants. Deconvolution helps identify contaminants that are buried in the chromatogram by co-extracted materials and significantly reduces chromatographic resolution requirements, allowing shorter analysis times. All compounds have locked retention times and we can continually update and extend the mass spectral library including new compounds. Linearity and limits of detection in SIM and full-scan mode were studied. Method detection limits (MDLs) in effluent wastewater ranged in most of the cases from 1 to 36 ng/L in SIM mode and from 4 to 66 ng/L in full-scan mode; while in river water from 0.4 to 14 and 2–29 ng/L in SIM and full-scan mode, respectively. We obtained a linearity of the calibration curves over two orders of magnitude. The method has been applied to the screening of a large number of organic contaminants – not only to a subset of targets – in urban wastewaters from different wastewater treatment plants and also in river waters. Most of the target compounds were detected at concentration levels ranging from 11 to 8697 ng/L and from 7 to 1861 ng/L in effluent wastewater and river waters, respectively. Additionally, a group of 12 new compounds were automatically identified using the AMDIS and NIST libraries. Other compounds, such as the 4-amino musk xylene, a synthetic fragrance metabolite, which was not included in the databases, but has been manually searched in the full-scan chromatograms.  相似文献   

11.
Two screening methods have been developed for simultaneous determination of ten extensively used personal care products (PCPs) and two alkylphenol surfactants in fish. The methods consisted of extraction, clean-up, derivatization and analysis by gas chromatography–mass spectrometry with selected ion monitoring (GC–SIM–MS) or gas chromatography–tandem mass spectrometry (GC–MS/MS) techniques. Among solvents tested to assess recovery of target compounds from 1-g tissue homogenates, acetone was selected as optimal for extracting compounds with dissimilar physicochemical properties from fish tissue. Initial experiments confirmed that GC–SIM–MS could be applied for analysis of lean fillet tissue (<1% lipid) without gel-permeation chromatography (GPC), and this approach was applied to assess the presence of target analytes in fish fillets collected from a regional effluent-dominated stream in Texas, USA. Benzophenone, galaxolide, tonalide, and triclosan were detected in 11 of 11 environmental samples at concentrations ranging from; 37 to 90, 234 to 970, 26 to 97, and 17 to 31 ng/g, respectively. However, performance of this analytical approach declined appreciably with increasing lipid content of analyzed tissues. Successful analysis of samples with increased lipid content was enabled by adding GPC to the sample preparation protocol and monitoring analytes with tandem mass spectrometry. Both analytical approaches were validated using fortified fillet tissue collected from locations expected to be minimally impacted by anthropogenic influences. Average analyte recoveries ranged from 87% to 114% with RSDs <11% and from 54% to 107% with RSDs <20% for fish tissue containing <1% and 4.9% lipid, respectively. Statistically derived method detection limits (MDLs) for GC–SIM–MS and GC–MS/MS methodologies ranged from 2.4 to 16 ng/g, and 5.1 to 397 ng/g, respectively.  相似文献   

12.
Two-dimensional gas chromatography (GC × GC) coupled with time-of-flight mass spectrometric (TOFMS) method was optimized for simultaneous analysis of 160 pesticides, 12 dioxin-like polychlorinated biphenyls (PCBs), 12 polyaromatic hydrocarbons (PAHs) and bisphenol A in grape and wine. GC × GC–TOFMS could separate all the 185 analytes within 38 min with >85% NIST library-based mass spectral confirmations. The matrix effect quantified as the ratio of the slope of matrix-matched to solvent calibrations was within 0.5–1.5 for most analytes. LOQ of most of the analytes was ≤10 μg/L with nine exceptions having LOQs of 12.5–25 μg/L. Recoveries ranged between 70 and 120% with <20% expanded uncertainties for 151 and 148 compounds in grape and wine, respectively, with intra-laboratory Horwitz ratio <0.2 for all analytes. The method was evaluated in the incurred grape samples where residues of cypermethrin, permethrin, chlorpyriphos, metalaxyl and etophenprox were detected at below MRL.  相似文献   

13.
In this paper, a novel and recyclable amino-functionalized nano-composite material (NCM) using tetraethylenepentamine (TEPA) as a coupling agent was synthesized. The properties of the TEPA-NCM were characterized by transmission electron microscopy (TEM), Fourier transform infrared analysis (FTIR), thermogravimetric analysis (TGA) and elemental analysis (EA). An effective dispersive solid-phase extraction (dSPE) procedure using the TEPA-NCM was developed, and comparative studies were carried out among Carbon/NH2 SPE, primary secondary amine (PSA) dSPE and TEPA-NCM dSPE. The results showed that TEPA-NCM dSPE was faster, easier and more effective to clean and enrich than the Carbon/NH2 cartridges, and the TEPA-NCM was much more effective to remove the pigments in vegetable samples than the PSA materials. The TEPA-NCM could be reused at least five times without much sacrifice of the cleanup efficiency. Furthermore, a gas chromatography–triple quadrupole mass spectrometry (GC–QqQ-MS/MS) method was established for the simultaneous determination of 29 pesticides (such as organochlorine and organophosphorus pesticides) in vegetables by dSPE using acetonitrile as an extraction solvent and TEPA-NCM as an adsorbent instead of PSA. The recoveries were in the range of 75–114% for all analytes except for trans-chlordane. The RSDs were in the range of 2–17%. The linearities were in the range of 0.4–100.0 μg/kg with determination coefficients (r2) higher than 0.986 for all compounds. The limits of detection (LODs) for all pesticides were less than 0.29 μg/kg and the limits of quantification (LOQs) were between 0.17 and 0.95 μg/kg. The developed method was applied to fifteen real vegetable samples, and it was confirmed that the TEPA-NCM was one of a kind of highly effective dSPE materials used for the pesticides analyses.  相似文献   

14.
The gas chromatographic–mass spectrometric (GC–MS) separation of all 209 polychlorinated biphenyl (PCB) congeners was studied on an extremely efficient 80 m × 0.1 mm i.d. capillary column coated with a 0.1 μm film of poly(5%-phenyl methyl)siloxane stationary phase. The quality of the separation and the number of resolved and coeluting peaks were compared to predictions according to the statistical overlap theory (SOT) and to literature data on PCB separations obtained by one-dimensional and comprehensive two-dimensional GC (GC × GC) and GC–MS. Mass spectral and chemometric deconvolution procedures were used to resolve overlapping peaks. On the highly efficient column, 195 PCB congeners were resolved in 96 min separation time using spectral and chemometric deconvolution. This number is comparable to the best separations described in GC × GC–MS mode. The novel method was developed for spectral deconvolution of overlapped PCB congeners which was verified determining the most toxic, dioxin-like PCBs both in the model mixture of 209 PCBs as well as in the Aroclor 1242 and Aroclor 1254 formulations.  相似文献   

15.
A rapid, specific and sensitive multiresidue method to determine 42 pesticides in made tea, tea infusion and spent leaves has been developed and validated for the routine analysis by liquid chromatography–tandem mass spectrometry (LC–MS/MS). The method was reproducible (Horwitz ratio (HorRat) <0.5 at 50 ng/g) and validated by the analysis of sample spiked at 50 and 100 ng/g in made tea, tea infusion and spent leaves. The samples were extracted with ethyl acetate + cyclohexane (9:1; v/v), and the extracts were cleaned up by dispersive solid phase extraction with primary secondary amine sorbent + graphitized carbon black + Florisil. The recoveries of all the pesticides were between 70% and 120% with a relative standard deviation of less than 15% and correlation coefficient for each pesticide was R2 ≥0.99. The matrix effect on signal of respective compounds was measured by comparing matrix-matched calibration standards with those in solvent-only. The limits of quantitation (LOQ) met the requirements of the maximum residue limits (MRLs) for pesticides in tea as recommended by the European Union.  相似文献   

16.
Pre-concentration and determination of 8 phenolic compounds in water samples has been achieved by in situ derivatization and using a new liquid–liquid microextraction coupled GC–MS system. Microextraction efficiency factors have been investigated and optimized: 9 μL 1-undecanol microdrop exposed for 15 min floated on surface of a 10 mL water sample at 55 °C, stirred at 1200 rpm, low pH level and saturated salt conditions. Chromatographic problems associated with free phenols have been overcome by simultaneous in situ derivatization utilizing 40 μL of acetic anhydride and 0.5% (w/v) K2CO3. Under the selected conditions, pre-concentration factor of 235–1174, limit of detection of 0.005–0.68 μg/L (S/N = 3) and linearity range of 0.02–300 μg/L have been obtained. A reasonable repeatability (RSD ≤ 10.4%, n = 5) with satisfactory linearity (0.9995 ≥ r2 ≥ 0.9975) of results illustrated a good performance of the present method. The relative recovery of different natural water samples was higher than 84%.  相似文献   

17.
A novel approach for the determination of seven fungicides (metalaxyl-M, penconazole, folpet, diniconazole, propiconazole, difenoconazole and azoxystrobin) in wine samples is presented. Analytes were extracted from the matrix and transferred to a small volume of a high density, water insoluble solvent using solid-phase extraction (SPE) followed by dispersive liquid–liquid microextraction (DLLME). Variables affecting the performance of both steps were thoroughly investigated (metalaxyl-M was not included in some optimisation studies) and their effects on the selectivity and efficiency of the whole sample preparation process are discussed. Under optimised conditions, 20 mL of wine were first concentrated using a reversed-phase sorbent and then target compounds were eluted with 1 mL of acetone. This extract was mixed with 0.1 mL of 1,1,1-trichloroethane (CH3CCl3) and the blend added to 10 mL of ultrapure water. After centrifugation, an aliquot (1–2 μL) of the settled organic phase was analyzed by gas chromatography (GC) with electron capture (ECD) and mass spectrometry (MS) detection. The method provided enrichment factors (EFs) around 200 times and an improved selectivity in comparison to use of SPE as single sample preparation technique. Moreover, the yield of the global process was similar for red and white wine samples and the achieved limits of quantification (LOQs) (from 30 to 120 ng L−1 and from 40 to 250 ng L−1, for GC–ECD and GC–MS, respectively) were low enough for the determination of target species in commercial wines. Among compounds considered in this work, metalaxyl-M and azoxystrobin were found in several wines at concentrations from 0.8 to 32 ng mL−1.  相似文献   

18.
Gas chromatography with electron capture detector (ECD), nitrogen-phosphorus detector (NPD), and tandem mass spectrometry (MS/MS) was used to identify 36 pesticides, widely used to control various pest and diseases in vegetables, in water after a preconcentration step on C18 cartridges. The recoveries obtained ranged from 70 to 135% at a fortification level of 100 ng/L with relative standard deviations of <36.2%. The limits of detection and quantitation were < or =48 and < or =160 ng/L, respectively. Important advantages of MS/MS over ECD and NPD in the determination of pesticides are also presented. The proposed analytical methodology was applied to the determination of pesticides in groundwater samples from an agricultural area, the Campo de Dalías (Almería, Spain). The most frequently encountered pesticides were endosulfan sulfate and metalaxyl, whereas the pesticide found at the highest concentration was fenamiphos.  相似文献   

19.
Complementary methods using liquid chromatography–tandem quadrupole mass spectrometry (LC–MS/MS) and comprehensive two-dimensional gas chromatography–time-of-flight mass spectrometry (GC × GC–TOF-MS) were developed and applied to determine targeted metabolites involved in central carbon metabolism [including tricarboxylic acid cycle, serine cycle, ethylmalonyl-coenzyme A (ethylmalonyl-CoA) pathway and poly-β-hydroxybutyrate cycle] of the bacterium Methylobacterium extorquens AM1 grown on two carbon sources, ethylamine (C2) and succinate (C4). Nucleotides, acyl-CoAs and a few volatile metabolites in cell extracts of M. extorquens AM1 were readily separated using either hydrophilic interaction liquid chromatography or reversed-phase liquid chromatography, and detected with good sensitivity by MS/MS. However, volatile intermediates within a low mass range (<300 m/z), especially at low abundance (such as glyoxylic acid and others <500 nM), were more effectively analyzed by GC × GC–TOF-MS which often provided better sensitivity, resolution and reproducibility. The complementary nature of the LC-based and GC-based methods allowed the comparison of 39 metabolite concentrations (the lowest level was at 139.3 nM). The overlap between the LC-based and GC-based methods of seven metabolites provided a basis to check for consistency between the two methods, and thus provided some validation of the quantification accuracy. The abundance change of 20 intermediates further suggested differences in pathways linked to C2 and C4 metabolism.  相似文献   

20.
In this study, the feasibility of GC–MS was evaluated for the quantification of odorous volatile organic compounds (VOCs) in environmental samples. These included methyl ethyl ketone, isobutyl alcohol, methyl isobutyl ketone, and butyl acetate plus benzene, toluene, and xylene (BTX). For this purpose, the gaseous standard for these VOCs were analyzed by GC–MS with the aid of both direct injection (DI) into the GC injector and solid-phase microextraction (SPME). The liquid phase standard prepared independently was tested additionally by the DI method as a reference to gaseous calibration. The detection limit (DL) values, when tested for basic quality assurance in this study, showed large differences between DI (0.002–0.007 ng) and SPME method (1.03–1.81 ng) in terms of absolute mass. The DL values, when expressed in terms of concentration (v/v), showed considerable improvement in SPME (below 0.40 nmol mol−1) relative to the DI method (∼6–15 nmol mol−1). The reliability of the GC–MS method was further validated through an analysis of real environmental samples collected from an industrial area.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号