首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 36 毫秒
1.
Two methods for determining the central-acting muscle relaxant afloqualone in human plasma were developed and compared using API2000 and API4000 liquid chromatography tandem mass spectrometry (LC/MS/MS) systems. In the API2000 LC/MS/MS system, afloqualone and the internal standard methaqualone were extracted from plasma using a methyl-tertiary ether. After drying the organic layer, the residue was reconstituted in a mobile phase (0.1% formic acid-acetonitrile:0.1% formic acid buffer, 80:20 v/v) and injected onto a reversed-phase C18 column. The isocratic mobile phase was eluted at 0.2 ml/min. The ion transitions monitored in multiple reaction-monitoring mode were m/z 284 → 146 and 251 → 117 for afloqualone and methaqualone, respectively.Sample preparation for the API4000 LC/MS/MS system involved simple protein precipitation with an organic mixture (methanol:10% ZnSO4 = 8:2). The ion transitions monitored in multiple reaction-monitoring mode were m/z 284 → 146 and 251 → 131 for afloqualone and methaqualone, respectively.In both assays, the coefficient of variation of the precision was less than 11.8%, the accuracy exceeded 91.5%, the limit of quantification was 0.5 ng/ml, and the limit of detection was 0.1 ng/ml for afloqualone. Two methods were used to measure the plasma afloqualone concentration in healthy subjects after a single oral 20-mg dose of afloqualone. During subsequent application of the methods, we observed that high-concentration plasma samples (>7 ng/ml) prepared using the protein precipitation method resulted in about 20% higher afloqualone concentrations than with plasma samples prepared using the liquid-liquid extraction method. We believe that this phenomenon was related to the cleanness of the sample and its chemical nature.  相似文献   

2.
We developed a sensitive and useful method for the determination of five fluoroquinolones (FQs), enoxacin, ofloxacin, ciprofloxacin, norfloxacin, and lomefloxacin in environmental waters, using a fully automated method consisting of in-tube solid-phase microextraction (SPME) coupled with liquid chromatography-tandem mass spectrometry (LC/MS/MS). These compounds were analysed within 7 min by high-performance liquid chromatography (HPLC) using a CAPCELL PAK C8 column and aqueous ammonium formate (pH 3.0, 5 mM)/acetonitrile (85/15, v/v) at a flow rate of 0.2 mL/min. Electrospray ionization conditions in the positive ion mode were optimized for MS/MS detection. In order to optimize the extraction of FQs, several in-tube SPME parameters were examined. The optimum in-tube SPME conditions were 20 draw/eject cycles of 40 μL of sample at a flow-rate of 150 μL/min, using a Carboxen 1010 PLOT capillary column as an extraction device. The extracted compounds were easily desorbed from the capillary by passage of the mobile phase. Using the in-tube SPME LC/MS/MS method, good linearity of the calibration curve (r ≥ 0.997) was obtained in the concentration range from 0.1 to 10 ng/mL for all compounds examined. The limits of detection (S/N = 3) of the five FQs ranged from 7 to 29 pg/mL. The in-tube SPME method showed 60-94-fold higher sensitivity than the direct injection method (5 μL injection). This method was applied successfully to the analysis of environmental water samples without any other pretreatment and interference peaks. Several surface waters and wastewaters were collected from the area around Asahi River, and ofloxacin was detected in wastewater samples of a sewage treatment plant and other two hospitals at 17.5-186.2 pg/mL. The recoveries of FQs spiked into river water were above 81% for a 0.1 or 0.2 ng/mL spiking concentration, and the relative standard deviations were below 1.9-8.6%.  相似文献   

3.
19-Nortestosterone (nandrolone) major metabolites in human urine are excreted as sulfoconjugated and glucuroconjugated forms. A sensitive and selective liquid chromatography/tandem mass spectrometry (LC/MS/MS) method in negative ESI mode was developed for direct quantification of 19-norandrosterone sulfate (19-NAS) and 19-noretiocholanolone sulfate (19-NES). For both sulfoconjugates, the [M−H] ion at m/z 355 and the fragment ion at m/z 97 were used as the precursor and product ions, respectively. The purification method involved a complete and rapid separation of sulfates and glucuronides in two extracts after loading the sample on a weak anion exchange solid phase extraction support (SPE Oasis® WAX). Then, sulfates were separated by LC (Uptisphere® ODB, 150 mm × 3.0 mm, 5 μm) and analyzed on a linear trap and a triple quadrupole mass spectrometer. The lower limit of detection (LLOD) and lowest limit of quantification (LLOQ) were of 100 pg mL−1 and 1 ng mL−1, respectively. Assay validation demonstrated good performances in terms of trueness (92.0-104.9%), repeatability (0.6-7.2%) and intermediate precision (1.3-10.8%) over the range of 1-2500 ng mL−1. Finally, 19-NAS and 19-NES in urine samples collected after intake of 19-norandrostenedione (nandrolone precursor) were quantified. This assay may be easily implemented to separate glucuronide and sulfate steroids from urine specimens prior to quantification by LC/MS/MS.  相似文献   

4.
Lopinavir and ritonavir are co-formulated in Kaletra® approved for the treatment of human immunodeficiency virus infection. A validated analytical method is mandatory for clinical development and therapeutic drug monitoring. Here we are reporting a method for rapid, simultaneous determination of lopinavir and ritonavir in human plasma with stacked protein precipitations and salting-out assisted extraction (SALLE), and ultrafast LC-MS/MS detection. With stacked protein precipitations and SALLE, the sample preparation for a 96-well plate can be completed within 20 min by an automated pipette. Due to the unique cleanliness of SALLE extracts post double protein precipitations, the extracts were injected into an ultrafast liquid chromatography and tandem mass spectrometry system (LC-MS/MS) after simple dilution. An Agilent Zobax Extend-C18 Rapid resolution HT column (1.8 μm, 2.1 mm × 30 mm) was used for the separation. A mixture of acetonitrile:water (55:45, v/v) with 0.1% formic acid was used as the mobile phase. LC ran for approximately 48 s at a flow rate of 0.5 mL min−1, tandem mass spectrometric data collection started at 15 s and lasts for 30 s. The method was validated with reference to Industry Guidance for Bioanalytical Method Validation and then used for clinical samples. The method is ultrafast, and robust. Results of incurred samples demonstrated excellent method of reproducibility. This ultrafast analysis speed did not compromise with the data quality. To our knowledge, this is the fastest analytical method for simultaneous determination of lopinavir and ritonavir.  相似文献   

5.
We developed a new analysis method for the nine N-methyl carbamate pesticides in fruits and vegetables using ESI LC/MS/MS with direct sample injection into a short column. After extraction of the pesticides with ethyl acetate from sample, the extract is evaporated to dryness and redissolved in ultra pure water before injection into LC/MS/MS. The method needs no cleanup steps. The average recoveries from fruits and vegetables fortified at the level of 0.01 μg/g ranged from 56.0 to 119.1% with the coefficients of variation ranging from 0.2 to 7.6% for intra-day (n = 5 × 3 days) and from 0.8 to 18.4% for inter-day (n = 15). At the fortified level of 0.5 μg/g, the recoveries ranged from 67.7 to 119.3% with the coefficients of variation ranging from 0.5 to 7.8% for intra-day (n = 5 × 3 days) and from 0.9 to 14.8% for inter-day (n = 15). The method is considered to be satisfactory for the monitoring of the carbamate pesticide residues in fruits and vegetables, suggesting that the present method is applicable to other pesticide residues in foods.  相似文献   

6.
New hyphenated technique for the extraction and determination of isoflavones in sea and freshwater algae and cyanobacteria was developed. The method consists of sonication sample pretreatment, extraction by supercritical CO2 modified by 3% (v/v) of MeOH/H2O mixture (9:1, v/v) at 35 MPa and 40 °C for 60 min, fast chromatography analysis by the means of Agilent 1200 Series Rapid Resolution and MS/MS determination. Agilent 1200 Series RRLC was used with Zorbax SB-CN chromatographic column (100 mm × 2.1 mm, particle size 3.5 μm), 3 μl injection volume, mobile phase consisting of 0.2% (v/v) acetic acid in water (solvent A) and acetonitrile (solvent B) and used with linear gradient (30% B at 0 min, from 0 min to 3 min up to 50% B, from 3 to 6 min up to 80% B and from 6 to 10 min down to 30% B). The flow-rate was 0.4 mL/min, column oven temperature 35 °C. MS detector Agilent Technologies 6460 Triple quadrupole LC/MS with Agilent Jet Stream was used in a negative ESI mode under following conditions: gas temperature 350 °C, gas flow 13 L/min, nebulizer gas pressure 50 psi, sheath gas temperature 400 °C, sheath gas flow 12 L/min, capillary voltage was 4 kV. Samples were analysed in the multiple reaction monitoring (MRM) mode. Eight isoflavone compounds were found for the first time in seven real samples of sea algae and in three control samples of freshwater algae and cyanobacteria. Usual optimisation study of extraction parameters was performed. Pressure and temperature optima for algae matrix are different from those obtained sooner for other matrices for most of the analytes, but the results of modifier optimisation study are in good accordance with those obtained sooner for spiked samples and red clover matrix. It seems that matrix has very small or no effect on the modifier selection. Two different approaches of sonication pretreatment were tested: sonication bath and the thorn instrument. In longer extraction time experiments, thorn sonication was more efficient and recovery of following supercritical fluid extraction was higher.  相似文献   

7.
A new simple, sensitive and selective liquid chromatography coupled with mass spectrometry (LC/MS) method for quantification of captopril after precolumn derivatization with p-bromo-phenacyl-bromide in human plasma was validated. Plasma samples were analysed on a monolithic column (Cromolith Performance-RP 18e, 100 mm × 4.6 mm I.D., 3 μm) under isocratic conditions using a mobile phase of a 40:60 (v/v) mixture of acetonitrile and 0.1% (v/v) formic acid in water. The flow rate was 1 mL/min at the column temperature of 30 °C. In these chromatographic conditions, the retention time was 4.4 min for captopril derivative. The detection of the analyte was in MRM mode using an ion trap mass spectrometer with electrospray positive ionisation. The monitored ions were 216, 253, 255, 268, 270 m/z derived from 415 m/z for derivatized captopril. The sample preparation was very simple and consisted in plasma protein precipitation from 0.2 mL plasma using 0.3 mL methanol after the derivatization reaction was completed. Calibration curves were generated over the range of 10-3000 ng/mL with values for coefficient of correlation greater than 0.993 and by using a weighted (1/y2) quadratic regression. The values for precision (CV %) and accuracy (relative error %) at quantification limit were less than 9.9% and 3.9%, for within- and between-run, respectively. The mean recovery of the analyte was 99%. Derivatized samples demonstrated good short-term, long-term, post-preparative and freeze-thaw stability. This is the first reported LC-MS/MS method for analysis of captopril in human plasma that uses protein precipitation as sample processing procedure. The method is very simple and allows obtaining a very good recovery of the analyte. The validated LC-MS/MS method has been applied to a pharmacokinetic study of 50 mg captopril tablets on healthy volunteers.  相似文献   

8.
A procedure for the determination of Imidacloprid and its main metabolites was set up by means of liquid chromatography with an electrochemical detector and post-column photochemical reactor (LC--ED). Sample clean-up was developed for bees, filter paper and maize leaves. Chromatographic conditions were based on a reversed-phase C-18 column operated by phosphate buffer 50 mM/CH3CN (80/20, v/v) at pH 2.9. Detection of Imidacloprid and its metabolites was performed at a potential of 800 mV after photoactivation at 254 nm. Compared to conventional techniques such as gas chromatography/mass spectrometry (GC/MS) or LC coupled to other detectors, the present method allows simultaneous trace-level determination of both Imidacloprid (0.6 ng ml−1) and its main metabolites (2.4 ng ml−1).  相似文献   

9.
In the present study, we have developed a method based on pressurized liquid extraction (PLE) and liquid chromatography with fluorescence detection (LC-FLD) for the determination of residues of fluoroquinolones (FQs) in infant food products. PLE extraction has been optimized by the application of experimental design methodologies. Initially, a fractional factorial design (FFD) was used to screen the significance of four extraction parameters: solvent composition, temperature, pressure and number of cycles. The most significant factors, identified by ANOVA analysis, were the solvent composition, temperature and pressure, which were further optimized with the aid of a face centred design (FCD) and the desirability function. The optimized operating PLE conditions were as follows: ACN/o-phosphoric acid 50 mM pH 3.0 (80:20, v/v), 80 °C, 2000 psi and three extraction cycles of 5 min. Under these conditions, recoveries of the target FQs varied between 69% and 107% with RSDs below 9%. The whole method was validated according to the Commission Decision 2002/657/EC guidelines. The proposed method has been successfully applied to the analysis of different infant food products bought in local supermarkets and pharmacies. The results showed the presence of residues of enrofloxacin in a non-compliant baby food sample corresponding to a chicken-based formulation, which were also confirmed and quantified by LC–MS/MS analysis.  相似文献   

10.
This paper describes an analytical method involving a simple solvent extraction for the simultaneous liquid chromatography coupled to quadrupole tandem mass spectrometry (LC-MS/MS) determination of carbosulfan, its most toxic metabolite -carbofuran -, and its other main metabolites - 3-hydroxycarbofuran, 3-ketocarbofuran, 3-hydroxy-7-phenolcarbofuran, 3-keto-7-phenolcarbofuran, 7-phenolcarbofuran and dibutylamine - in oranges. Chromatography was performed on a Zorbax Bonus-RP (150 mm × 2.1 mm, 5 μm). The mobile phase was a ternary gradient water-methanol-acetonitrile with 1.0 mM ammonium acetate at flow rate of 0.2 ml min−1. The LC separation and MS/MS optimization were studied to select the most appropriate operating conditions. The method developed has also been validated. The limits of quantification (LOQs) were from 1 μg kg−1 for carbofuran to 10 μg kg−1 for 3-keto-7-phenolcarbofuran. Extracts spiked with carbosulfan and its metabolites, at LOQ level, yielded average recoveries in the range 60-94%, with relative standard deviations (R.S.D.s) less than 15%. Calibration curves for carbosulfan and its metabolites (range LOQ-1000LOQ) were linear, with coefficients of correlations better than 0.990. The method was successfully applied to establish the primary degradation products in oranges treated with carbosulfan. The LC-MS/MS method developed is simple, rapid, and suitable for the quantification and confirmation of carbosulfan and seven of its main metabolites in orange at levels lower than 10 μg kg−1.  相似文献   

11.
We have developed and validated a sensitive method for the simultaneous determination of some monoamine neurotransmitters like dopamine (DA), norepinephrine (NE) and serotonin (5-HT) in rat brain microdialysate using high-performance liquid chromatography coupled to tandem mass spectrometry (LC/MS/MS). Sensitivity enhancement has been achieved by amine derivatization with the reagent (5-N-succinimidoxy-5-oxopentyl)triphenylphosphonium bromide (SPTPP) under mild conditions. The use of the selected reaction monitoring (SRM) mode has allowed detection of the analytes at a concentration of 30 pM (lower limit of quantification, LLOQ, signal-to-noise ratio higher than 5) with an accuracy of ≤3.80% and a precision of ±7.39 (%CV) for all neurotransmitters. Derivatization improves resolution and chromatographic retention times (3 min) by lipophilization. Linearity has been good (R > 0.99) over a large concentration range (30–50,000 pM). The intra and inter-batch accuracy and precision were not greater than 4.8% and 6.4%, respectively. Therefore, the method was successfully applied for monitoring the concentration changes of neurotransmitters in microdialysis samples deriving from striatum rat brain region after amphetamine administration (3 mg kg−1, i.p.).  相似文献   

12.
A rapid method for the identification and quantification of l-ascorbic acid in wines by direct injection liquid chromatography equipped with a UV detection was developed. The levels of ascorbic acid were determined using a polymeric PLRP-S 100 A (5 μm) column (150 mm × 4.6 mm) with a mobile water/trifluoroacetic acid (99/1, v/v) phase. The method is rapid (less than 5 min) and sensitive (LOQ of 5 mg L−1). The calibration curve of ascorbic acid was linear (r = 0.999) over a concentration range between 1 and 200 mg L−1. Repeatability was less than 2.5% and the recovery over 95%.  相似文献   

13.
Xanthones are well known for their interesting phytochemical properties, which make them attractive to the pharmaceutical and medicinal industry. We have therefore developed a method to analyse the major xanthones in Garcina mangostana. The xanthones were extracted by pressurized liquid extraction with ethanol and separated at the semi-preparative scale by centrifugal partition chromatography (CPC) with a biphasic solvent system consisting of heptane/ethyl acetate/methanol/water (2:1:2:1, v/v/v/v). A CPC-electrospray ionisation MS coupling was performed and used to simultaneously separate and identify the compounds. Thanks to a variable flow splitter and an additional stream of ethanol/1 mol L−1 ammonium acetate (95:5, v/v), all the compounds were ionised, detected and monitored whatever the solvents used in mobile phase for the CPC separation. The dual mode or elution–extrusion which are less solvent-consuming and faster than the elution mode were used without loss of ionisation and detection.  相似文献   

14.
Heon-Woo Lee 《Talanta》2007,71(1):62-67
A simple, rapid, and sensitive high-performance liquid chromatography (HPLC)-electrospray ionization (ESI) tandem mass spectrometric method (LC-MS/MS) has been developed for simultaneous determination of cilazapril levels and its active metabolite, cilazaprilat, in human plasma using enalapril as internal standard. The acquisition was performed in the multiple reaction monitoring mode; monitoring the transitions: m/z 418.4 > 211.1 for cilazapril and m/z 390.3 > 211.1 for cilazaprilat. The method involves a simple single-step liquid-liquid extraction with ethyl acetate. The analyte was chromatographed on an YMC C8 reversed-phase chromatographic column by isocratic elution with 10 mM ammonium formate buffer-methanol (10:90, v/v; pH 3.2 with formic acid). Numerous compounds did not interfere with specific multiple reaction monitoring in tandem mass spectrometric detection following C8 reversed-phase chromatographic separation under conditions that eluted cilazapril, cilazaprilat, and enalapril within 2 min. This method was validated over 0.1-500 ng ml−1 of cilazapril and 0.5-50 ng ml−1 of cilazaprilat. Cilazapril and cilazaprilat were stable in standard solution and in plasma samples under typical storage and processing conditions. The assay was successfully applied to a pharmacokinetic study of cilazapril given as a single oral dose (5 mg) to healthy volunteers.  相似文献   

15.
A simple method using a one-step liquid-liquid extraction (LLE) with butyl acetate followed by high-performance liquid chromatography (HPLC) with positive ion electrospray ionization tandem mass spectrometric (ESI-MS/MS) detection was developed for the determination of itopride in human plasma, using sulpiride as an internal standard (IS). Acquisition was performed in multiple reaction monitoring (MRM) mode, by monitoring the transitions: m/z 359.5 > 166.1 for itopride and m/z 342.3 > 111.6 for IS, respectively. Analytes were chromatographed on an YMC C18 reverse-phase chromatographic column by isocratic elution with 1 mM ammonium acetate buffer-methanol (20: 80, v/v; pH 4.0 adjusted with acetic acid). Results were linear (r2 = 0.9999) over the studied range (0.5-1000 ng mL−1) with a total analysis time per run of 2 min for LC-MS/MS. The developed method was validated and successfully applied to bioequivalence studies of itopride hydrochloride in healthy male volunteers.  相似文献   

16.
A new method based on enzymatic probe sonication extraction prior to high-performance liquid chromatography (HPLC) has been developed for the determination of 11 antibiotics (drugs) and the main metabolites of five of them in fish tissue and mussel samples. The analytes belong to four different classes of antibiotics (sulfonamides, tetracyclines, penicillins and amphenicols). The analysed compounds were sulfadiazine (SDI) and N4-acetylsulfadiazine (NDI) metabolite, sulfamethazine (SMZ) and N4-acetylsulfamethazine (NMZ), sulfamerazine (SMR) and N4-acetylsulfamerazine (NMR), sulfamethoxazole (SMX), trimetroprim (TMP), amoxicillin (AMX) and its main metabolite amoxicilloic acid (AMA), ampicillin (AMP) and its main metabolite ampicilloic acid (APA), chloramphenicol (CLF), thiamphenicol (TIF), oxytetracycline (OXT) and chlortetracycline (CLT).The main factors affecting the extraction efficiency (type of enzyme, type and volume of extractant, ultrasounds power and extraction time) were optimised in tissue of hake (Merluccius merluccius), anchovy (Engraulis encrasicolus), mussel (Mytilus sp.) and wedge sole (Solea solea). The extraction was carried out using an extraction time of 5 min with 5 mL of water and subsequent clean-up with dichloromethane.High-performance liquid chromatography (HPLC) with diode array (DAD) and fluorescence (FLD) detectors was used for the determination of the antibiotics. The separation of the analysed compounds was conducted by means of a Phenomenex® Gemini C18 (150 mm × 4.6 mm I.D., particle size 5 μm) analytical column with LiChroCART® LiChrospher® C18 (4 mm × 4 mm, particle size 5 μm) guard-column. Analysed drugs were determined using formic acid 0.1% (v/v) in water and acetonitrile in gradient elution mode as mobile phase. The proposed method was also evaluated by a laboratory assay consisting of the determination of the targeted analytes in samples of Cyprinus carpio which had previously administered the antibiotics.  相似文献   

17.
A simple and sensitive high performance liquid chromatography method with photodiode array detection (HPLC-DAD) was developed for simultaneous determination of eight bioactive constituents (schisandrin, schisandrol B, schisantherin A, schisanhenol, anwulignan, deoxyshisandrin, schisandrin B and schisandrin C) in the ripe fruit of Schisandra sphenanthera and its traditional Chinese herbal preparations Wuzhi-capsule by optimizing the extraction, separation and analytical conditions of HPLC-DAD. The chemical fingerprint of S. sphenanthera was established using raw materials of 15 different origins in China. The chromatographic separations were obtained by an Agilent Eclipse XDB-C18 reserved-phase column (250 mm × 4.6 mm i.d., 5 μm) using gradient elution with water-formic acid (100:0.1, v/v) and acetonitrile, at a flow rate of 1.0 mL min−1, an operating temperature of 35 °C, and a wavelength of 230 nm. The constituents were confirmed by (+) electrospray ionization LC-MS. The new method was validated and was successfully applied to simultaneous determination of components in 13 batches of Wuzhi-capsule. The results indicate that this multi-component determination method in combination with chromatographic fingerprint analysis is suitable for quantitative analysis and quality control of S. sphenanthera.  相似文献   

18.
Tussilago farfara (Kuan Donghua) is an important Chinese herbal medicine which has been shown to contain many bioactive compounds and widely used to relieve cough and resolve phlegm. However, besides therapeutic bioactive compounds, this herb has been found to contain toxic pyrrolizidine alkaloids (PAs), mainly senkirkine and traces of senecionine. In this report, conditions for microwave-assisted extraction (MAE) and pressurized hot water extraction (PHWE) were optimized for the extraction of the PAs. The results were compared against heating under reflux. It was found that the binary mixture of MeOH:H2O (1:1) acidified using HCl to pH 2-3 was the optimal solvent for the extraction of the PAs in the plant materials. Liquid chromatography (LC) with ultra-violet (UV) detection and electrospray ionization mass spectrometry (ESI-MS) in the positive mode was used for the determination and quantitation of senkirkine and senecionine in the botanical extract. The proposed extraction methods with LC/MS allow for the rapid detection of the major and the minor alkaloids in T. farfara in the presence of co-eluting peaks. With LC/MS, the quantitative analysis of PAs in the extract was done using internal standard calibration and the precision was found to vary from 0.6% to 5.4% on different days. The limits of detection (LODs) and limits of quantitation (LOQs) for MAE and PHWE were found to vary from 0.26 μg/g to 1.04 μg/g and 1.32 μg/g to 5.29 μg/g, respectively. The method precision of MAE and PHWE were found to vary from 3.7% to 10.4% on different days. The results showed that major and minor alkaloids extracted using MAE and PHWE were comparable to that by heating under reflux. Our data also showed that significant ion suppression was not observed in the analysis of senkirkine and senecionine in the botanical extracts with co-eluting peaks.  相似文献   

19.
Hydrophilic interaction liquid chromatography (HILIC)–electrospray ionization-mass spectrometry (ESI-MS) was evaluated for the analysis of tributyltin (TBT) and triphenyltin (TPT) in water samples. Separation was performed in isocratic mode on an Atlantis HILIC silica (2.1 mm × 150 mm, 5 μm) column with a mobile phase of acetonitrile–0.1% aqueous HCOOH (86:14, v/v) at a flow rate of 0.2 mL/min. Under optimum conditions, limits of detection for TBT and TPT were 10 and 20 pg injected onto the column, respectively. The extraction of triorganotin compounds from seawater samples was carried out using a polymer-based solid phase extraction cartridge of mixed modes with reversed-phase and weak anion exchange. Tributyltin-d27 chloride and triphenyltin-d15 chloride were used as internal standards. The relative standard deviations for the analysis were less than 4%. Using the proposed method, it was possible to analyze concentrations of TPT and TBT in seawater at ppt levels.  相似文献   

20.
We describe a sensitive and rapid method to assay urinary cotinine levels among non-smokers using liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI/MS/MS) and its application in studies assessing exposures to second hand smoke (SHS). Cotinine was initially extracted from 1 ml of urine with methylene chloride by using a liquid-liquid extraction Chem Elut™ column. The extracted sample was further separated by using a BetaBasic C18 column (1 mm × 150 mm, 3 μm) with isocratic elution (60:40 acetonitrile and 5 mM ammonium acetate at pH 5), and then examined using a triple quadrupole mass spectrometer with an electrospray ionization (ESI) source in multiple-reaction-monitoring (MRM) mode. The elution of cotinine from the LC column took approximately 2.3 min and the detection of cotinine by ESI/MS/MS provided a limit of detection (LOD) of 0.3 ng/ml. The ESI/MS/MS detection was able to easily distinguish between cotinine and nicotine. This method, validated using a cotinine concentration range from 0.8 to 102.4 ng/ml, was successfully applied in a cross-sectional study examining differences in levels and sources of second hand smoke (SHS) exposure among non-smokers. Self-reported measures of SHS exposure were significantly associated with urinary cotinine levels. This urinary cotinine assay using LC-ESI/MS/MS provides a robust, high throughput and very sensitive method for the evaluation of SHS exposure for use in epidemiologic and clinical research studies.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号