首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 78 毫秒
1.
Counter-current chromatographic separation of proteins was performed using a rotary-seal-free nonsynchronous coil planet centrifuge (CPC) fabricated in our laboratory. This apparatus has a unique feature that allows a freely adjustable rotational rate of the coiled separation column at a given revolution speed. The separation was performed using a set of stable proteins including cytochrome c, myoglobin and lysozyme with two different types of aqueous-aqueous polymer phase systems, i.e., PEG (polyethylene glycol) 1000-dibasic potassium phosphate, and PEG 8000-dextran T500 in 5 mM potassium phosphate buffer. Using a set of multilayer coiled columns prepared from 0.8 mm I.D. PTFE tubing with different volumes (11, 24, 39 ml), the effect of the column capacity on the partition efficiency was investigated under a given set of experimental conditions. Among these experiments, the best separation of proteins was attained using the 39 ml capacity column with a 12.5% (w/w) PEG 1000-12.5% (w/w) dibasic potassium phosphate system at 10 rpm of coil rotation under 800 rpm. With lower phase mobile at 0.2 ml/min in the head-to-tail elution, the resolution between cytochrome c and myoglobin was 1.6 and that between myoglobin and lysozyme, 1.9. With upper phase mobile in the head-to-tail elution, the resolution between lysozyme and myoglobin peaks was 1.5. In these two separations, the stationary phase retention was 35.0 and 33.3%, respectively. Further studies were carried out using a pair of eccentric coil assemblies with 0.8 mm I.D. PTFE tubing at a total capacity of 20 ml. A comparable resolution was obtained using both lower and upper phases as a mobile phase in a head-to-tail elution. The results of our studies demonstrate that the nonsynchronous CPC is useful for protein separation with aqueous-aqueous polymer phase systems.  相似文献   

2.
Traditional Chinese medicines (TCMs) have attracted much attention in recent years. Elution-extrusion and/or back-extrusion counter-current chromatography (EECCC/BECCC) both take full advantage of the liquid nature of the stationary phase. They effectively extend the solute hydrophobicity window that can be studied and rendered the CCC technique particularly suitable for rapid analysis of complex samples. In this paper, a popular traditional Chinese medicine, Evodia rutaecarpa, was used as the target complex mixture for extrusion CCC separations. With a carefully selected biphasic liquid system (n-hexane/ethyl acetate/methanol/water, 3/2/3/2, v/v) and optimized conditions (VCM = VC, mobile phase flow rate: 3 mL/min in descending mode, sample loading: 100 mg), five fractions could be obtained in only 100 min on a 140-mL capacity CCC instrument using both elution- and back-extrusion methods. Each fraction was analyzed and identified compared with the data of major standards using LC/MS. Moreover, the performance of both extrusion protocols was systematically compared and summarized. EECCC could be operated continuously and was found extremely suitable for high-throughput separation; however, post-column addition of a clarifying reagent is recommended to smooth the UV-signal during the extrusion process. Considering BECCC, the practical operation is very simple by just switching a 4-port valve to change the flow direction. The change of flowing direction should be done after a sufficient amount of mobile phase has flushed the column in the classical mode so that solutes with small and medium distribution constants have been eluted. Otherwise, a significant portion of the solutes will stay in the mobile phase inside the column, mix together and produce a broad peak showing in the mobile phase eluting after the stationary phase extrusion. Compared with classical CCC or other preparative separation tools, extrusion CCC approaches exhibit distinguished superiority in the modernization process of traditional Chinese medicines.  相似文献   

3.
A pyrimethanil-imprinted polymer (P1) was prepared by iniferter-mediated photografting a mixture of methacrylic acid and ethylene dimethacrylate onto homemade near-monodispersed chloromethylated polydivinylbenzene beads. The chromatographic behaviour of a column packed with these imprinted beads was compared with another column packed with irregular particles obtained by grinding a bulk pyrimethanil-imprinted polymer (P2). The comparison was made using the kinetic model of non-linear chromatography, studying the elution of the template and of two related substances, cyprodinil and mepanipyrim. Extension of the region of linearity, capacity factors for the template and the related substances, column selectivity, binding site heterogeneity, apparent affinity constant (K) and lumped kinetic association (ka) and dissociation rate constant (kd) were studied during a large interval of solute concentration, ranging between 1 and 2000 μg/ml. From the experimental results obtained, in the linearity region of solute concentration column selectivity and binding site heterogeneity remained essentially the same for the two columns, while column capacity (at 20 μg/ml, P1 = 23.1, P2 = 11.5), K (at 20 μg/ml, P1 = 8.3 × 106 M−1, P2 = 2.5 × 106 M−1) and ka (at 20 μg/ml, P1 = 3.5 μM−1 s−1, P2 = 0.47 μM−1 s−1) significantly increased and kd (at 20 μg/ml, P1 = 0.42 s−1, P2 = 0.67 s−1) decreased for the column packed with the imprinted beads. These results are consistent with an influence of the polymerisation method on the morphology of the resulting polymer and not on the molecular recognition properties due to the molecular imprinting process.  相似文献   

4.
The present research is focused on the GC-FID determination of fatty acid methyl esters (FAMEs) in diesel blends, by means of an ionic liquid stationary phase, characterized by a dicationic 1,9-di(3-vinyl-imidazolium)nonane bis(trifluoromethyl)sulfonylimidate structure (SLB-IL100). The high polarity of the ionic liquid stationary phase allowed the separation of the FAMEs, from the less-retained hydrocarbons, thus avoiding the requirement of a hydrocarbon LC pre-separation. The results derived from the analyses of a soybean FAMEs B20 sample, carried out on an SLB-IL100 conventional column (30 m × 0.25 mm i.d. × 0.20 mm df), were compared with those attained on a polyethylene glycol column, of equivalent dimensions. Conventional and fast GC methods, for the analysis of FAMEs in diesel blends, were developed on an SLB-IL100 30 m × 0.25 mm i.d. × 0.20 μm df and on an SLB-IL100 12 m × 0.10 mm i.d. × 0.08 μm df column, respectively. The optimized IL methods were subjected to validation: retention time and peak area intra-day precision (n = 5) were good, with CV % values lower than 0.08% and 4.9%, respectively. With regards to the quantitation of FAMEs in biodiesel blends, a five points calibration curve was constructed, using C17:0 as internal standard.  相似文献   

5.
A new Dynamic Extractions Maxi-counter-current chromatography (CCC) centrifuge with a column volume of 18-l has been installed in the Advanced Bioprocessing Centre at Brunel. This instrument has four times the capacity of the 4.6-l Maxi-CCC centrifuge which has been operating robustly for 3 years. Tests using the model sample system benzyl alcohol and p-cresol with a heptane:ethyl acetate:methanol:water (HEMWat) phase system (1.4:0.1:0.5:1.0) show that resolution is almost double with this new high capacity device. Commissioning tests with a mixture of caffeine, KD = 0.21; ferulic acid, KD = 0.82; umbelliferone, KD = 1.2 and vanillin, KD = 1.49 using a HEMWat phase system of 1:1.5:1:1.5 on the 9-l column show that resolutions equivalent to analytical instruments will be possible using the full 18-l capacity. They also show that predictable scale-up from simple test tube tests is feasible with knowledge of the stationary phase retention for the planned process scale run.  相似文献   

6.
Yan H  Row KH 《Analytica chimica acta》2007,584(1):160-165
A sensitive, simple, and accurate method for determination of levofloxacin and its (R)-enantiomer was developed to determine the chiral impurity of levofloxacin in Cravit Tablets material by ligand-exchange high performance liquid chromatography. The effects of different kinds of ligands, concentration of ligands in mobile phase, organic modifier, pH of mobile phase, and temperature on enantioseparation were investigated and evaluated. Chiral separation was performed on a conventional C18 column, where the mobile phase consisted of a methanol-water solution (containing10 mmol L−1l-leucine and 5 mmol L−1 copper sulfate) (88:12, v/v) and its flow-rate was set at 1.0 mL min−1. The conventional C18 column offers baseline separation of two enantiomers with a resolution of 2.4 in less than 20 min. Thermodynamic data (ΔΔH and ΔΔS) obtained by Van’t Hoff plots revealed the chiral separation is an enthalpy-controlled process. The standard curves showed excellent linearity over the concentration range from 0.5 to 400 mg L−1 for levofloxacin and its (R)-enantiomer. The linear correlation equations are: y = 1.33 × 105x + 6297 (r = 0.9991) and y = 1.34 × 105x + 3565 (r = 0.9997), respectively. The relative standard deviation (RSD) of the method was below 2.3% (n = 3).  相似文献   

7.
Pseudo-SMB, often called “J-O process”, is a modified SMB process to completely separate a ternary mixture with two discrete steps per one cycle. For improved separation, two new design parameters, the position of step 1 (χS1) and the number of port switches during step 2 (nSMB), were introduced. A multi-objective optimization method was used to optimize the operating conditions of the pseudo-SMB process with four average zone flow-rate ratios for one cycle. Nadolol isomers were selected for the model solutes and the global objective for the design of the pseudo-SMB was to collect 99% of the intermediate retained solute. The separation was optimized for 8-column pseudo-SMB system with three column lengths (2.5, 5.0, and 10 cm) and three feed composition ratios (1/1/1, 1/2/1, and 2/1/2). The simulation results showed that productivity was increased 4.3 times (nSMB = 20, χS1 = 0.5, 1/1/1) and desorbent to feed ratio D/F was decreased 45% (nSMB = 16, χS1 = 0.5, 1/1/1) compared to normal operation (nSMB = 8, χS1 = 0.5, 1/1/1). Productivity and D/F were significantly improved when short columns were used in the pseudo-SMB process. The pseudo-SMB was compared with recycle chromatography and SMB cascades for the same total amount of adsorbent. Recycle chromatography and 8-column SMB cascades using 20 cm and 40 cm of total column lengths were not able to separate the intermediate component with the target purity and the same feed rate of the pseudo-SMB process.  相似文献   

8.
Gong B  Zhu J  Li L  Qiang K  Ren L 《Talanta》2006,68(3):666-672
The monodisperse, 5.0 μm non-porous poly(glycidylmethacrylate-co-ethylenedimethacrylate) (PGMA/EDMA) beads were prepared by a single-step swelling and polymerization method. The seed particles prepared by dispersion polymerization exhibited good absorption of the monomer phase. Based on this media, a weak cation exchange (WCX) stationary phase for high performance liquid chromatography (HPLC) was synthesized by a new chemical modification method. The prepared resin has advantages of biopolymer separation, high column efficiency, low column backpressure, high protein mass recovery and good resolution for proteins. The measured bioactivity recovery for lysozyme was 97 ± 5%. The dynamic protein loading capacity of the synthesized WCX packings was 20.5 mg/g. Four proteins were completely separated in 3.0 min using the synthesized WCX stationary phase. The experimental results show that the obtained WCX resin has very weak hydrophobicity. The WCX resin was also used for the rapid separation and purification of lysozyme from egg white in 3.0 min with only one step. The purity and specific bioactivity of the purified lysozyme was found more than 95% and 70.264 IU/mg, respectively.  相似文献   

9.
A simple accurate method for determining amino acid composition of wheat gluten proteins and their gliadin and glutenin fractions using high-performance anion-exchange chromatography with integrated pulsed amperometric detection is described. In contrast to most conventional methods, the analysis requires neither pre- or post-column derivatization, nor oxidation of the sample. It consists of hydrolysis (6.0 M hydrochloric acid solution at 110 °C for 24 h), evaporation of hydrolyzates (110 °C), and chromatographic separation of the liberated amino acids. Correction factors (f) accounted for incomplete cleavage of peptide bonds involving Val (f = 1.07) and Ile (f = 1.13) after hydrolysis for 24 h and for Ser (f = 1.32) losses during evaporation. Gradient conditions including an extra eluent (0.1 M acetic acid solution) allowed multiple sequential sample analyses without risk of Glu contamination on the anion-exchange column. While gluten amino acid compositions by the present method were mostly comparable to those obtained by a conventional method involving oxidation, acid hydrolysis and post-column ninhydrin derivatization, the latter method underestimated Tyr, Val and Ile levels. Results for the other amino acids obtained by the different methods were linearly correlated (r > 0.99, slope = 1.03).  相似文献   

10.
Porous layer open tubular (PLOT) polystyrene divinylbenzene columns have been used for separating intact proteins with gradient elution. The 10 μm I.D. × 3 m columns were easily coupled to standard liquid chromatography–mass spectrometry (LC–MS) instrumentation with commercially available fittings. Standard proteins separated on PLOT columns appeared as narrow and symmetrical peaks with good resolution. Average peak width increased linearly with gradient time (tG) from 0.14 to 0.33 min (tG 20 and 120 min, respectively) using a 3 m column. With shorter columns, peak widths were larger and increased more steeply with gradient time. Theoretical peak capacity (nc) increased with column length (tested up to 3 m). The nc increased with tG until a plateau was reached. The highest peak capacity achieved (nc = 185) was obtained with a 3 m column, where a plateau was reached with tG 90 min. The within- and between column retention time repeatabilities were below 0.6% and below 2.5% (relative standard deviation, RSD), respectively. The carry-over following injection of 0.5 ng per protein was less than 1.1%. The retention time dependence on column temperature was investigated in the range 20–50 °C. Proteins in a skimmed milk sample were separated using the method.  相似文献   

11.
A simple, stability-indicating high-performance thin-layer liquid chromatographic (HPTLC) method for analysis of minocycline was developed and validated. The densitometric analysis was carried out at 345 nm using methanol-acetonitrile-isopropyl alcohol-water (5:4:0.5:0.5, v/v/v/v) as mobile phase.The method employed TLC aluminium plates pre-coated with silica gel 60F-254 as the stationary phase. To achieve good result, plates were sprayed with a 10% (w/v) solution of disodium ethylene diaminetetraacetic acid (EDTA), the pH of which was adjusted to 9.0. Compact spots of minocycline were found at Rf = 0.30 ± 0.02. For proposed procedure, linearity (r = 0.9997), limit of detection (3.7 ng spot−1), recovery (99.23-100.16%), and precision (% R.S.D. ≤ 0.364) was found to be satisfactory. The drug undergoes acidic and basic degradation, oxidation and photodegradation. All the peaks of degradation products were well resolved from the pure drug with significantly different Rf values. The acidic and alkaline degradation kinetics of minocycline, evaluated using this method, is found to be of first order.  相似文献   

12.
In the present work, the separations of calixarene derivatives have been investigated using both high-performance liquid chromatography (HPLC) and nonaqueous capillary electrophoresis (NACE) techniques. HPLC-1 method with LC-318 (pore size = 300 Å) column and MeCN mobile phase was optimized for the separation of calixarenes. At the flow-rate of 1 ml/min p-nitrocalix[6]arene, calix[4]arene and calix[6]arene could be well baseline and symmetrically separated within 5 min. For the separation of p-tert-butylcalix[n]arenes (n = 4, 6, 8), HPLC-2 and NACE methods have been optimized. The optimal conditions in HPLC-2 method included NH2 column and MeCN mobile phase, and p-tert-butylcalix[n]arenes (n = 4, 6, 8) were baseline separated within 10 min at 0.8 min/min. The optimal conditions for NACE method employed MeCN-H2O (8:2, v/v) as the nonaqueous medium and 120 mM Tris/HCl (pH 9.0) as the buffer, and p-tert-butylcalix[n]arenes (n = 4, 6, 8) were successfully baseline resolved within 16 min. With the detection at 280 nm, the calibration lines were linear in the ranges of 1-200 μg/ml for calixarene derivatives by HPLC-1 and HPLC-2 methods, and of 2.5-200 μg/ml for p-tert-butylcalix[n]arenes (n = 4, 6, 8) by NACE method, respectively. The detection limits (S/N = 3) and recoveries ranged from 0.5 to 1.4 μg/ml and from 98.1 to 102.4% by both HPLC-1 and HPLC-2 methods, and from 1.3 to 2.0 μg/ml and from 97.9 to 105.1% by NACE method, respectively. The intra-day reproducibility of the methods was determined with satisfactory results. The proposed HPLC and NACE methods were accurate and reproducible, and could be utilized to separate and determine calixarene derivatives.  相似文献   

13.
The role of electrostatics is studied in the adsorption of cationic proteins to zwitterionic phosphatidylcholine (PC) and anionic PC/phosphatidylglycerol (PG) mixed small unilamellar vesicles (SUVs). For model proteins the interaction is monitored vs. PG content at low ionic strength. The adsorption of lysozyme and myoglobin (isoelectric point, pI 7-11) is investigated in SUVs, along with changes of the fluorescence emission spectra of the cationic proteins, via their adsorption on SUVs. In the Gouy-Chapman formalism, the activity coefficient goes with the square of charge number. Deviations from the ideal model could indicate the asymmetric location of the anionic phospholipid in the bilayer inner leaflet, in mixed zwitterionic/anionic SUVs for both lysozyme- and myoglobin-PC/PG systems, in agreement with experiments and molecular dynamics simulations. Fitted effective SUV charge stays constant. Effective—formal difference increases 0.417 e.u. Effective protein charge increases as PC/PG < PC being greater for myoglobin. The molar free energies of the protein in aqueous and lipid phases increase as PC < PC/PG. Both free-energy changes are greater for myoglobin. Effective interfacial charge stays constant for anionic PC/PG SUVs being greater for myoglobin.  相似文献   

14.
A compact type-I coil planet centrifuge has been developed for performing counter-current chromatography. It has a revolution radius of 10 cm and a column holder height of 5 cm compared with 37 and 50 cm in the original prototype, respectively. The reduction in the revolution radius and column length permits application of higher revolution speed and more stable balancing of the rotor which leads us to learn more about its performance and the future potential of type-I coil planet centrifuge. The chromatographic performance of this apparatus was evaluated in terms of retention of the stationary phase (Sf), peak resolution (Rs), theoretical plate (N) and peak retention time (tR). The results of the experiment indicated that increasing the revolution speed slightly improved both the retention of the stationary phase and the peak resolution while the separation time is remarkably shortened to yield an excellent peak resolution at a revolution speed of 800 rpm. With a 12 ml capacity coiled column, DNP-DL-glu, DNP-β-ala and DNP-l-ala were resolved at Rs of 2.75 and 2.16 within 90 min at a flow rate of 0.4 ml/min. We believe that the compact type-I coil planet centrifuge has a high analytical potential.  相似文献   

15.
A sensitive and specific liquid chromatography-electrospray ionization-mass spectrometry (LC-ESI-MS) method for the separation and analysis of d- and l-thyroxine was developed using R(−)/S(+)-4-(3-isothiocyanatopyrrolidin-1-yl)-7-(N,N-dimethylaminosulfonyl-2,1,3-benzoxadiazole, [R(−)/S(+)-DBD-PyNCS] as a chiral derivatization reagents. The T4 derivatives with R(−)-DBD-PyNCS were efficiently separated on a reversed-phase column with water-acetonitrile containing 0.1% formic acid (41:59, v/v) as the eluent and analyzed using ESI-MS with negative selected ion monitoring (SIM) mode. The calibration curves of both the d-T4 and l-T4 were linear over the concentration range of 0.13-13 μg/ml. The detection limits (S/N = 3) were 28 ng/ml for d-T4 and 40 ng/ml for l-T4, respectively. The relative standard deviations (RSD, n = 5) were less than 3.6% at 1.3 μg/ml for both T4 enantiomers. The proposed method was applied to the determination of l-T4 enantiomer in a pharmaceutical formulation.  相似文献   

16.
Hydrated layered crystalline barium phenylarsonate, Ba(HO3AsC6H5)2·2H2O was used as host for intercalation of n-alkylmonoamine molecules CH3(CH2)n-NH2 (n = 1-4) in aqueous solution. The amount intercalated (nf) was followed batchwise at 298 ± 1 K and the variation of the original interlayer distance (d) for hydrated barium phenylarsonate (1245 ppm) was followed by X-ray powder diffraction. Linear correlations were obtained for both d and nf as a function of the number of carbon atoms in the aliphatic chain (nc): d = (2225 ± 32) + (111 ± 11)nc and nf = (2.28 ± 0.15) − (11.50 ± 0.03)nc. The exothermic enthalpies of intercalation increased with nc, which was derived from the monomolecular amine layer arrangements with the longitudinal axis inclined by 60° to the inorganic sheets. The intercalation was followed by titration with amine at the solid/liquid interface and gave the enthalpy/number of carbons correlation: ΔH = −(7.25 ± 0.40) − (1.67 ± 0.10)nc. The negative Gibbs free energies and positive entropic values reflect the favorable host/guest intercalation processes for this system.  相似文献   

17.
Two phenanthroline derivatives containing a hole transporting triphenylamine and an electron transporting 1,3,4-oxadiazole unit have been prepared with high yield. UV-vis absorption and fluorescence measurement indicated they are high efficient light-emitting materials. The compounds are 6-(5-(4-N,N′-diphenylaminophenyl)-1,3,4-oxadiazol-2-yl) quinoxalino[2,3-f] phenanthroline (9, λmax = 635 nm, 40% quantum yield), and 1-ethyl-2-(4-(5-(4-N,N′-diphenylaminophenyl)-1,3,4-oxadiazol-2-yl)phenyl)imidazo[4,5-f]phenanthroline (14, λmax = 461 nm, 78% quantum yield). Preliminary study on electroluminescence for the two fluorescent dyes prepared from vacuum evaporation resulted in blue and red light emitting organic light emitting diodes (OLED).  相似文献   

18.
In this study, an ultra-sensitive method for the quantification of lysozyme based on the Gd3+ diethylenetriamine-N,N,N′,N″,N″-pentaacetic acid labeling and capillary electrophoresis–inductively coupled plasma mass spectrometry (CE–ICP–MS) was described. The Gd3+-tagged lysozyme was effectively separated by capillary electrophoresis (CE) and sensitively determined by inductively coupled plasma mass spectrometry (ICP–MS). Based on the gadolinium-tagging and CE–ICP–MS, the lysozyme was determined within 12 min with an extremely low detection limit of 3.89 attomole (3.89 × 10−11 mol L−1 for 100 nL of sample injection) and a RSD < 6% (n = 5). The proposed method has been successfully used to detect lysozyme in saliva samples with a recovery of 91–106%, suggesting that our method is sensitive and reliable. The success of the present method provides a new potential for the biological assays and sensitive detection of low-abundant proteins.  相似文献   

19.
A new thermometric sensor, which is a transistor (OC71), has been introduced to follow thermometric titrations successfully to clear end points. The sensor was suitable in both normal and differential modes of titration. It is possible to titrate down to 1.32 μmol of HCl and 26.4 μmol of H3BO3in a final 20 ml solution with accuracy and precision of 1%, 2.2% and 1.4%, 2.2%, respectively. The sensor, in association with a pH glass electrode, was used for the determination of pK values of some well established weak acids such as, acetic acid (4.77), phosphoric acid (pK1 = 2.18, pK2 = 7.20 and pK3 = 12.32) as well as for a very weak acid of uncertain pK values H3BO3 (pK1 = 9.20, pK2 = 12.7 and pK3 = 13.80). The sensor was also examined for kinetic catalytic determination of iron(III) in water, milk and pharmaceuticals.  相似文献   

20.
A sensitive and selective preconcentration method has been developed for mercury using naphthalene-methyltrioctylammonium chloride (Aliquat 336s) as an adsorbent. Mercury as HgI42− was retained by the adsorbent in the column at a flow rate of 1 ml min−1. The column was washed by a solution of sodium tetraphenylborate and sodium iodide to elute the adsorbed mercury. The eluents were collected in a 10 ml volumetric flask and diluted to the mark with water, transferred to a voltammetric cell and anodic stripping-differential pulse voltammetry was performed. Preconcentration factors of 40 and 80 could be achieved when using a 10 and 5 ml voltammetric cell, respectively. The calibration graph was linear in the range of 1.2-8.7 ng ml−1 Hg(II) in the initial solution with r=0.9998 (n=6) and the 3 s detection limit was 0.13 ng ml−1 when using a 10 ml cell. The relative standard deviation for eight replicate measurements of 1.2, 5.0 and 8.7 ng ml−1 of Hg(II) in the initial solution was 0.51, 0.71 and 0.80%, respectively. The proposed method was successfully applied to determination of mercury in natural waters, wastewater and synthetic samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号