首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A new method based on combination of solid- and liquid-phase microextraction was developed. For the first time, porous flower-like silica microstructures with nanometric layers were created on the surface of the stainless steel wire by a new facile hydrothermal process. The fiber, coated with a suitable organic solvent, was applied for microextraction of some organophosphorus pesticides from aqueous samples followed by gas chromatography-nitrogen phosphorous detection. Method detection limits were between 0.6 and 3 ng L−1. Relative standard deviations for intra- and inter-day precision were 4.4–7.3% and 5.1–7.8%, respectively. Fiber-to-fiber reproducibility for five prepared fibers was 6.3–8.4%. Tap, river and waste water samples were analyzed for evaluation of the method in real sample analysis. Relative recoveries for spiked tap, river and waste water samples were in the range of 94–101%, 89–97% and 82–103%, respectively. In addition, the method was compared with two commercial solid-phase microextraction (SPME) fibers, single drop microextraction (SDME) and liquid-phase microextraction (LPME). The present method showed higher extraction efficiency as compared with SDME, LPME and commercial SPME fibers.  相似文献   

2.
A new hyphenated technique couples supercritical fluid extraction in situ derivatization and on-line headspace solid-phase microextraction to gas chromatography-mass spectrometry (SFE in situ derivatization on-line HS-SPME-GC-MS) for the determination of paraben preservatives and polyphenolic antioxidants in cosmetics. The preservatives and antioxidants were extracted from the cosmetic matrices with supercritical carbon dioxide at a pressure of 13,840 kPa. The supercritical fluid extraction was performed at 55 °C for 10 min of static extraction then 15 min of dynamic extraction. The extractant subsequently was derivatized in situ with the silylation reagent N,O-bis(trimethylsilyl)trifluoroacetamide with 0.1% trimethylchlorosilane. The product was then adsorbed on a polyacrylate solid-phase microextraction (SPME) fiber in the headspace. Sea sand was used as a dispersive material in the SFE step. The analytical linear ranges for the preservatives and antioxidants were found to be from 10 to 1000 ng g−1 with RSD values below 7.8%. The detection limits ranged from 0.5 to 8.3 ng g−1. These results are better than those obtained by using only SPME or SFE for trace preservatives and antioxidants analysis in cosmetic matrices. The new method was successfully utilized to determine the amounts of preservatives and antioxidants in real cosmetics without the need for tedious pretreatments.  相似文献   

3.
This work is a first study on extraction efficiency and thermal stability of nano-structured self-doped polyaniline (SPAN) as a coating of solid-phase microextraction (SPME) fibers. SPAN-based fibers were prepared using electrochemical deposition on platinum wires. The particle sizes of prepared nano-structure were in the range of 50–100 nm. Extraction properties of the fiber to 1,4-dioxane were examined using headspace solid-phase microextraction (HS-SPME) coupled to gas chromatography-flame ionization detection (GC-FID). The results have proved higher thermal stability of the proposed fiber compared to common PANI fiber. The SPAN coating was proved to be very stable at relatively high temperatures (up to 350 °C) with high extraction capacity and long lifespan (more than 50 times). Therefore, it can be a good substitute of polyaniline (PANI) as a SPME coating. The extraction procedure was optimized by selecting the appropriate extraction parameters including extraction time, extraction temperature, salt concentration, stirring rate and headspace volume. Calibration graph was linear in the concentration range of 1–100 ng mL−1 (R2 > 0.993) with detection limit of 0.1 ng mL−1. Single fiber and fiber-to-fiber repeatability were lower than 6.0% and 10.4%, respectively. Different water samples were analyzed as real samples and good recoveries (98–120%) were obtained.  相似文献   

4.
A suitable analytical procedure based on static headspace solid-phase microextraction (SPME) followed by thermal desorption gas chromatography-ion trap mass spectrometry detection (GC-(ITD)MS), was developed and applied for the qualitative and semi-quantitative analysis of volatile components of Portuguese Terras Madeirenses red wines. The headspace SPME method was optimised in terms of fibre coating, extraction time, and extraction temperature. The performance of three commercially available SPME fibres, viz. 100 mum polydimethylsiloxane; 85 mum polyacrylate, PA; and 50/30 mum divinylbenzene/carboxen on polydimethylsiloxane, was evaluated and compared. The highest amounts extracted, in terms of the maximum signal recorded for the total volatile composition, were obtained with a PA coating fibre at 30 degrees C during an extraction time of 60 min with a constant stirring at 750 rpm, after saturation of the sample with NaCl (30%, w/v). More than sixty volatile compounds, belonging to different biosynthetic pathways, have been identified, including fatty acid ethyl esters, higher alcohols, fatty acids, higher alcohol acetates, isoamyl esters, carbonyl compounds, and monoterpenols/C(13)-norisoprenoids.  相似文献   

5.
Ji J  Deng C  Shen W  Zhang X 《Talanta》2006,69(4):894-899
In this work, portable gas chromatography-microflame ionization detection (portable GC-μFID) coupled to headspace solid-phase microextraction (HS-SPME) was developed for the field analysis of benzene, toluene, ethylbenzene and xylene (BTEX) in water samples. The HS-SPME parameters such as fiber coating, extraction times, stirring rate, the ratio of headspace volume to sample volume, and sodium chloride concentration were studied. A 65 μm poly(dimethylsiloxane)-divinylbenzene (PDMS-DVB) SPME fiber, 900 rpm, 3.0 ml of headspace (1.0 ml water sample in 4.0 ml vial), and 35% sodium chloride concentration (w/v) were respectively chosen for the best extraction response. An extraction time of 1.0 min was enough to extract BTEX in water samples. The relative standard deviation (R.S.D.) for the procedure varied from 5.4% to 8.3%. The method detection limits (MDLs) found were lower than 1.5 μg/l, which was enough sensitive to detect the BTEX in water samples. The optimized method was applied to the field analysis of BTEX in wastewater samples. These experiment results show that portable GC-μFID combined with HS-SPME is a rapid, simple and effective tool for field analysis of BTEX in water samples.  相似文献   

6.
Solid-phase microextraction of polychlorinated biphenyls   总被引:8,自引:0,他引:8  
The extraction and analysis of 21 polychlorinated biphenyls (PCBs) ranging from di- to decachlorobiphenyls in ocean, wetland and leachate water samples were achieved using solid-phase microextraction (SPME) with a 100-μm poly(dimethylsiloxane) (PDMS) fiber and gas chromatography–electron-capture detection (GC–ECD). Severe carryover between samples (e.g., 20%) occurs on both stir bars and the SPME fibers demonstrating that it is important to use a new stir bar for each sample, as well as to perform SPME–GC blanks between samples to avoid quantitative errors. The equilibrium partitioning coefficients of individual PCB congeners between PDMS and water were found to be surprisingly different compared to their octanol–water partitioning coefficient (Kow), demonstrating that Kow cannot be used to estimate the partitioning behavior of PCBs in the SPME process. Using a 15-min SPME extraction, SPME analysis with GC–ECD was linear (r2≥0.97) from 5 pg/ml to the solubility limit of each congener. Concentrations in water samples obtained by 15-min SPME extractions compared favorably with those obtained by toluene extractions, demonstrating that SPME combined with GC is a useful technique for the rapid determination of PCBs in water samples.  相似文献   

7.
A solid-phase microextraction (SPME) method for the determination of five amphetamine type stimulants (ATSs) in water and urine samples is presented. Analytes were simultaneously derivatized with iso-butyl chloroformate (iBCF) in the aqueous sample while being extracted, improving in this way the extractability of ATSs and permitting their determination by gas chromatography–mass spectrometry (GC–MS). The SPME procedure was carefully optimized in order to achieve adequate limits of detection (LODs) for environmental concentrations. Hence, different operational parameters were considered: type of SPME coating, ionic strength, basic catalyzer and derivatizing agent amount, extraction time and temperature. The final SPME procedure consists into the extraction of 100 mL of sample containing 2 g of dipotassium monohydrogen phosphate trihydrate and 100 μL of iBCF (1:1 in acetonitrile), for 40 min at 60 °C with a polydimethylsiloxane-divinylbenzene (PDMS-DVB) fiber. Under these conditions, LODs in wastewater ranged from 0.4 to 2 ng L−1, relative recoveries in the 84–114% range and relative standard deviations (RSD) lower than 15% were obtained. The application of the method to wastewater and river water samples showed the ecstasy ATS, 3,4-methylenedioxymethamphetamine (MDMA), as the most frequently detected, followed by methamphetamine, in concentrations around 20 ng L−1. Finally, the method was downscaled and also validated with urine samples, proving its good performance with this matrix too: RSD < 11%, recoveries in the 98–110% range and LODs lower than 0.1 μg L−1.  相似文献   

8.
Yan CT  Shih TS  Jen JF 《Talanta》2004,64(3):650-654
Microwave-assisted desorption (MAD) coupled to in situ headspace solid-phase microextraction (HS-SPME) was first proposed as a possible alternative pretreatment of samples in absorbent collected from workplace monitoring. Aniline collected on silica gel was investigated. Under microwave irradiation, the aniline was desorbed from silica gel and directly absorbed onto the SPME fiber in the headspace. Having been sampled on the SPME fiber, and desorbed in the GC injection port, aniline was analyzed using a GC-FID system. Parameters that affect the proposed extraction efficiency, including the extraction media and its pH, the microwave irradiation power and the irradiation time as well as desorption parameters of the GC injector, were investigated. Experimental results revealed that the extraction of a 150-mg silica gel sample using a 0.8-ml aqueous solution (pH 12) and a PDMS/DVB fiber under medium-high-powered irradiation (345 W) for 3 min maximized the efficiency of extraction. Desorption of aniline from the SPME fiber was optimal at 230 °C held for 3 min. The detection limit was 0.09 ng. The proposed method provided a simple, fast, and organic solvent-free procedure to analyze aniline from a silica gel matrix.  相似文献   

9.
A method based on solid-phase microextraction (SPME) and gas chromatography-mass spectrometry (GC-MS) has been optimized for the determination of fragrance allergens in water samples. This is the first study devoted to this family of cosmetic ingredients performed by SPME. The influence of parameters such as fibre coating, extraction and desorption temperatures, salting-out effect and sampling mode on the extraction efficiency has been studied by means of a mixed-level factorial design, which allowed the study of the main effects as well as two-factor interactions. Excluding desorption temperature, the other parameters were, in general, very important for the achievement of high response. The final procedure was based on headspace sampling at 100 °C, using polydimethylsiloxane/divinylbenzene fibres. The method showed good linearity and precision for all compounds, with detection limits ranging from 0.001 to 0.3 ng mL−1. Reliability was demonstrated through the evaluation of the recoveries in different real water samples, including baby bathwater and swimming pool water. The absence of matrix effects allowed the use of external standard calibration to quantify the target compounds in the samples. The proposed procedure was applied to the determination of allergens in several real samples. All the target compounds were found in the samples, and, in some cases, at quite high concentrations. The presence and the levels of these chemicals in baby bathwater should be a matter of concern. Baby exposure to fragrance allergens and other cosmetic ingredients through the daily bath  相似文献   

10.
A simple and rapid solid-phase microextraction (SPME) method is presented based on activated charcoal–PVC fiber for determination of some organophosphorus pesticides from aqueous samples in direct mode SPME. After optimization of the experimental variables affecting SPME of the target compounds from aqueous solutions, the proposed method was applied to determine pesticides in fruit juice. The analytes in this procedure were preconcentrated for 15 min on the SPME fiber and subsequently desorbed by heating the fiber at 200 °C for 5 min in the GC injection port. Separation was on a capillary column GC followed by flame ionization detection. Recoveries of the pesticides studied in aqueous samples ranged 42%–63% and repeatability for all analytes was < 9% for a single fiber. Fiber-to-fiber reproducibility was < 18%.  相似文献   

11.
An in-syringe ultrasound-assisted emulsification microextraction (USAEME) was developed for the extraction of organophosphorus pesticides (OPPs) from water samples. The OPPs subsequently analyzed gas chromatography (GC) using a microelectron capture detector (μECD). Ultrasound radiation was applied to accelerate the emulsification of μL-level low-density organic solvent in aqueous solutions to enhance the microextraction efficiency of OPPs in the sample preparation for GC-μECD. Parameters affecting the efficiency of USAEME, such as the extraction solvent, solvent volume, pH, salt-addition, and extraction time were thoroughly investigated. Based on experimental results, OPPs were extracted from a 5 mL aqueous sample by the addition of 20 μL toluene as the extraction solvent, followed by ultrasonication for 30 s, and then centrifugation for 3 min at 3200 rpm, offered the best extraction efficiency. Detections were linear in the concentration of 0.01–1 μg/L with detection limits between 1 ng/L and 2 ng/L for OPPs. Enrichment factors ranged from 330 to 699. Three spiked aqueous samples were analyzed, and recovery ranged from 90.1% to 104.7% for farm-field water, and 90.1% to 101.8% for industrial wastewater. The proposed method provides a simple, rapid, sensitive, inexpensive, and eco-friendly process for determining OPPs in water samples.  相似文献   

12.
Benzophenones (BPs) are extensively used in a wide variety of cosmetic products and other materials (e.g., textiles or plastics) to avoid damaging effects of UV radiation. In the present work, we compared two extraction methods for the determination of BPs, namely, 2,4-dihydroxybenzophenone (BP-1), 2-hydroxy-4-methoxybenzophenone (BP-3) and 2,2-dihydroxy-4-methoxybenzophenone (BP-8), in water and cosmetics samples. The following extraction methods were used for the research: solid-phase extraction (SPE) and microextraction by packed sorbent (MEPS), whereas analysis was performed by gas chromatography with mass spectrometric detection. A comparison between the methods indicates that the MEPS technique(s) can be reliably used for analysis of BPs (sunscreen residue) in water samples and cosmetic samples with satisfactory results. This microextraction technique is cheap, easy, quick to implement, and consumes small amounts of solvents. On the other hand, the main advantage of the SPE method are low detection limits for the determination of BPs in water samples, i.e., from 0.034 to 0.067 µg L−1, while, for the MEPS method, LODs were at the level of 1.8–3.2 µg L−1. For both methods, the recoveries of BPs were 96–107% and 44–70% for water and cosmetics samples, respectively. The presented methods are suitable for use in cosmetics quality control and environmental pollution assessment.  相似文献   

13.
In this study, poly(ethylene glycol) (PEG) grafted multi-walled carbon nanotubes (PEG-g-MWCNTs) were synthesized by the covalent functionalization of MWCNTs with hydroxyl-terminated PEG chains. PEG-g-MWCNTs was used as a novel stationary phase to prepare the sol–gel solid-phase microextraction (SPME) fiber in combination with gas chromatography–flame ionization detector (GC–FID) for the determination of ibuprofen, naproxen and diclofenac in real water samples.  相似文献   

14.
Criado MR  Pereiro IR  Torrijos RC 《Talanta》2004,63(3):533-540
A procedure for the determination of several coplanar and non coplanar PCBs in ash samples is described. Analytes were extracted from the samples using dimethylsulfoxide (DMSO) under the action of a microwave field, and then they were concentrated on a PDMS-DVB solid-phase microextraction (SPME) fibre using the headspace mode, after water dilution of the DMSO extract. Determinations were carried out using GC-ECD and GC-MS detection. Influences of microwave extraction (solvent volume, temperature and time) and SPME conditions (stirring, kind of SPME fibre, salt and water addition, sampling time and temperature) on the performance of the whole analytical procedure were systematically investigated. Working under optimal conditions quantification limits from 0.2 to 1.5 ng g−1 were obtained for all the compounds, except for PCB 209, which could not be consistently extracted from the sample using the proposed conditions.  相似文献   

15.
In the study, nanoporous array anodic alumina (NAAA) prepared by a simple, rapid and stable two-step anodic oxidization method was introduced as a novel solid-phase microextraction (SPME) fiber coating. The regular nanoporous array structure and chemical composition of NAAA SPME fiber coating was characterized and validated by scanning electron microscopy and energy dispersive spectroscopy, respectively. Compared with the commercial polydimethylsiloxane (PDMS) SPME fiber coating, NAAA SPME fiber coating achieved the higher enrichment capability (1.7–4.7 folds) for the mixed standards of volatile organic compounds (VOCs). The selectivity for volatile alcohols by NAAA SPME fiber coating demonstrated an increasing trend with the increasing polarity of alcohols caused by the gradually shortening carbon chains from 1-undecanol to 1-heptanol or the isomerization of carbon chains of some typical volatile alcohols including 2-ethyl hexanol, 1-octanol, 2-phenylethanol, 1-phenylethanol, 5-undecanol, 2-undecanol and 1-undecanol. Finally, NAAA SPME fiber coating was originally applied for the analysis of biological VOCs of Bailan flower, stinkbug and orange peel samples coupled with gas chromatography–mass spectrometry (GC–MS) detection. Thirty, twenty-seven and forty-four VOCs of Bailan flower, stinkbug and orange peel samples were sampled and identified, respectively. Moreover, the contents of trace 1-octanol and nonanal of real orange peel samples were quantified for the further method validation with satisfactory recoveries of 106.5 and 120.5%, respectively. This work proposed a sensitive, rapid, reliable and convenient analytical method for the potential study of trace and small molecular biological VOCs by the novel NAAA SPME fiber coating.  相似文献   

16.
The complex aroma of wine is derived from many sources, with grape-derived components being responsible for the varietal character. The ability to monitor grape aroma compounds would allow for better understanding of how vineyard practices and winemaking processes influence the final volatile composition of the wine. Here, we describe a procedure using GC–MS combined with headspace solid-phase microextraction (HS-SPME) for profiling the free volatile compounds in Cabernet Sauvignon grapes. Different sample preparation (SPME fiber type, extraction time, extraction temperature and dilution solvent) and GC–MS conditions were evaluated to optimize the method. For the final method, grape skins were homogenized with water and 8 ml of sample were placed in a 20 ml headspace vial with addition of NaCl; a polydimethylsiloxane SPME fiber was used for extraction at 40 °C for 30 min with continuous stirring. Using this method, 27 flavor compounds were monitored and used to profile the free volatile components in Cabernet Sauvignon grapes at different maturity levels. Ten compounds from the grapes, including 2-phenylethanol and β-damascenone, were also identified in the corresponding wines. Using this procedure it is possible to follow selected volatiles through the winemaking process.  相似文献   

17.
The feasibility of solid-phase microextraction (SPME) for the determination of several organophosphorus flame retardants and plastizicers in water samples by gas chromatography-nitrogen phosphorous detection (GC-NPD) is evaluated. These compounds have a wide range of polarities and volatilities and require a thorough optimisation of the different SPME parameters. Considering also possible contamination and carryover sources, the best compromise microextraction conditions were found to be direct extraction of 22 ml samples, containing 300 mg/ml of NaCl, with a PDMS-DVB coated fibre at room temperature. Although equilibrium was not achieved, an extraction time of 40 min allowed obtaining a good sensitivity (quantification limits between 0.010 and 0.025 ng/ml), comparable to that achieved by solid-phase extraction (SPE) of 1l samples, producing both similar values of precision and accuracy. Furthermore, the SPME method has shown to be free of matrix effects, avoiding the need of employing the standard addition procedure for quantification, and was suitable for the determination of eight of the nine considered compounds. Only tris-(2-ethylhexyl)-phosphate was neither determinable by SPME nor by SPE. Finally, the application of the developed methodology to the analysis of wastewater samples, showed that important concentrations of these compounds (up to 10 ng/ml) have been detected in treated sewage water, being discharged into the aquatic environment.  相似文献   

18.
In this study, the feasibility of GC–MS was evaluated for the quantification of odorous volatile organic compounds (VOCs) in environmental samples. These included methyl ethyl ketone, isobutyl alcohol, methyl isobutyl ketone, and butyl acetate plus benzene, toluene, and xylene (BTX). For this purpose, the gaseous standard for these VOCs were analyzed by GC–MS with the aid of both direct injection (DI) into the GC injector and solid-phase microextraction (SPME). The liquid phase standard prepared independently was tested additionally by the DI method as a reference to gaseous calibration. The detection limit (DL) values, when tested for basic quality assurance in this study, showed large differences between DI (0.002–0.007 ng) and SPME method (1.03–1.81 ng) in terms of absolute mass. The DL values, when expressed in terms of concentration (v/v), showed considerable improvement in SPME (below 0.40 nmol mol−1) relative to the DI method (∼6–15 nmol mol−1). The reliability of the GC–MS method was further validated through an analysis of real environmental samples collected from an industrial area.  相似文献   

19.
A solid-phase microextraction method has been developed for the determination of 19 chlorophenols (CPs) in environmental samples. The analytical procedure involves direct sampling of CPs from water using solid-phase microextraction (SPME) and determination by liquid chromatography with electrochemical detection (LC-ED). Three kinds of fibre [50 microm carbowax-templated resin (CW-TPR), 60 microm polydimethylsiloxane-divinylbenzene (PDMS-DVB) and 85 microm polyacrylate (PA)] were evaluated for the analysis of CPs. Of these fibres, CW-TPR is the most suitable for the determination of CPs in water. Optimal conditions for both desorption and absorption SPME processes, such as composition of the desorption solvent (water-acetonitrile-methanol, 20:30:50) and desorption time (5 min), extraction time (50 min) and temperature (40 degrees C) as well as pH (3.5) and ionic strength (6 g NaCl) were established. The precision of the SPME-LC-ED method gave relative standard deviations (RSDs) of between 4 and 11%. The method was linear over three to four orders of magnitude and the detection limits, from 3 to 8 ng l(-1), were lower than the European Community legislation limits for drinking water. The method was applied to the analysis of CPs in drinking water and wood samples.  相似文献   

20.
Exposure to fragrance substances is exponentially increasing in our daily life due to the enhanced use of scented products. Some fragrances are known to be important sensitizers, inhalation being an important exposure pathway in indoor environments. A simple and sensitive method based on solid-phase enrichment and solid-phase microextraction (SPME) followed by gas chromatography–mass spectrometry (GC–MS) has been developed for the analysis of 24 volatile fragrance allergens in indoor air. Suspected allergens present in the air (0.2 m3) were adsorbed onto a very small quantity of florisil (25 mg) and then transferred to a SPME fiber in the headspace mode (HS). To the best of our knowledge, this paper describes the first application of SPME for the determination of these compounds in air samples. The experimental parameters affecting the microextraction process have been optimized using a multifactor experimental design strategy. Accuracy, linearity, precision and detection limits (LODs) were evaluated to assess the performance of the proposed method. External calibration, using spiked sorbent standards, and not requiring the complete sampling process (only the SPME step), demonstrated to be suitable for the quantification of all suspected allergens. Recovery studies were performed at three concentration levels (0.04, 1.00 and 50 μg m−3), obtaining quantitative recoveries (≥85%) in most cases. LOD values at the low ng m−3 level were achieved for all the target compounds. The application of the method to daily home air samples demonstrated the ubiquity of this kind of fragrance ingredients in quotidian indoor environments, finding 18 of the 24 considered compounds in concentrations ranging from 0.01 to 56 μg m−3. Benzyl alcohol, linalool, citronellol, ionone and lilial were found in most analyzed samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号