首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Bin Chen  Yingxiang Du  Ping Li 《Electrophoresis》2009,30(15):2747-2754
A wide number of chiral selectors have been employed in CE and among them macrocyclic antibiotics exhibited excellent enantioselective properties toward plenteous racemic drugs. Different from macrocyclic antibiotics, the use of lincomycin antibiotics as chiral selectors has not been reported previously. In this study clindamycin phosphate belonging to the group of lincomycin antibiotics is first used as a novel chiral selector for the enantiomeric separations of several racemic basic drugs, which possess high separability, consisting of nefopam, citalopram, tryptophan, chlorphenamine and propranolol. Other basic drugs giving partial enantioseparation include tryptophan methyl ester, metoprolol and atenolol. Clindamycin phosphate possesses advantages such as high solubility and low viscosity in the water and very weak UV absorption. In the course of this work we observed that both migration time and enantioseparation were influenced by several parameters such as pH of the BGE, clindamycin concentration, capillary temperature, applied voltage and organic modifier. The optimum pH that was in the neutral or weak basic region but varied among drugs, a low capillary temperature and a clindamycin concentration of 60 or 80 mM are recommended as the optimum conditions for chiral separation of these drugs. Moreover, comparison of the influences of the studied parameters was further investigated by means of Statistical Product and Service Solutions in this paper.  相似文献   

2.
3.
Chen J  Du Y  Zhu F  Chen B 《Journal of chromatography. A》2010,1217(45):7158-7163
Several chiral reagents including cyclodextrins (CDs) and derivatives, crown ethers, proteins, chiral surfactants and polymers have been involved in dual selector systems for enantioseparation of a series of chiral compounds by capillary electrophoresis (CE). In comparison to the chiral reagents above-mentioned, there is no report concerning the use of polysaccharides in dual chiral CE system. In this paper we first investigate the enantioselectivity of polysaccharide-based dual selector systems towards some chiral drugs. During our recent work, glycogen belonging to the class of branched polysaccharides has been used as a novel chiral selector in CE. In this study, three glycogen-based dual chiral CE systems have been established for enantiomeric separations of several racemic basic drugs consisting of duloxetine, cetirizine, citalopram, sulconazole, laudanosine, amlodipine, propranolol, atenolol and nefopam. These three dual systems combined glycogen (neutral polysaccharide) with chondroitin sulfate A (CSA, ionic polysaccharide), β-CD and HP-β-CD, respectively. It was found that the dual system of glycogen/CSA exhibited good enantioselective properties toward the tested drugs. More importantly, compared to the single selector systems, synergistic effect was observed when glycogen was used with CSA for most of the analytes. This indicated the enhancement of enantioseparation observed for these analytes in glycogen/CSA system might be due to some favorable interaction effects between glycogen and CSA. Moreover, in order to evaluate the stereoselectivity of glycogen/CSA, the influences of buffer pH and selector concentration on enantioseparation of the studied drugs were also investigated.  相似文献   

4.
Introducing a new class of chiral selectors is an interesting work and this issue is still one of the hot topics in separation science and chirality. In this study, for the first time, sulfated maltodextrin (MD) was synthesized as a new anionic chiral selector and then it was successfully applied for the enantioseparation of five basic drugs (amlodipine, hydroxyzine, fluoxetine, tolterodine, and tramadol) as model chiral compounds using CE. This chiral selector has two recognition sites: a helical structure and a sulfated group which contribute to three corresponding driving forces; inclusion complexation, electrostatic interaction, and hydrogen binding. Under the optimized condition (buffer solution: 50 mM phosphate (pH 3.0) and 2% w/v sulfated MD; applied voltage: 18 kV; temperature: 20°C), baseline enantioseparation was observed for all mentioned chiral drugs. When instead of sulfated MD neutral MD was used under the same condition, no enantioseparation was observed which means the resolution power of sulfated MD is higher than neutral MD due to the electrostatic interaction between sulfated groups and protonated chiral drugs. Also, the countercurrent mobility of negatively charged MD (sulfated MD) allows more interactions between the chiral selector and chiral drugs and this in turn results in a successful resolution for the enantiomers. Furthermore, a higher concentration of neutral MD (approximately five times) is necessary to achieve the equivalent resolution compared with the negatively charged MD.  相似文献   

5.
Tao Yu  Yingxiang Du  Bin Chen 《Electrophoresis》2011,32(14):1898-1905
Nowadays, macrocyclic antibiotics are presenting an increasing number of enantioseparation applications. The macrocyclic antibiotics used as chiral selectors in capillary electrophoresis (CE) include the ansamycins and the glycopeptides. The macrolides, another important class of macrocyclic antibiotics, have been reported as a new type of chiral selectors recently. In this study, clarithromycin lactobionate (CL), belonging to the group of macrolide antibiotics, was first investigated for its potential as a novel chiral selector in CE for enantiomeric separation of several basic drugs. As observed, CL allowed excellent separation of the enantiomers of metoprolol, atenolol, propranolol, bisoprolol, esmolol, ritodrine, and amlodipine, as well as partial enantioresolution of labetalol and nefopam. In addition, CL possesses advantages such as high solubility and low viscosity in the solvent and very weak UV absorption. In the course of this study, it was found that both migration times and enantioseparation of the basic drugs were influenced by several experimental parameters, e.g. selector concentration, the composition and pH of the BGE, the type and concentration of organic modifier, and applied voltage. Thus, the effects of these factors were systematically investigated, and satisfactory enantioseparations of the studied drugs were achieved at the buffer pH range of 7.3–7.5 using 12.5 mM borax buffer with 50% v/v methanol, 60 mM CL, and 20 kV applied voltage. Moreover, comparison of the influences of the studied parameters was further investigated by means of Statistical Product and Service Solutions (SPSS) in this article.  相似文献   

6.
7.
A fast and simple micellar electrokinetic capillary chromatographic method was developed for the analysis of piribedil in pharmaceutical formulations. The effects of buffer concentration, buffer pH, sodium dodecyl sulphate (SDS) concentration, organic modifier, applied voltage and injection time were investigated. Optimum results were obtained with a 50 mM borate buffer at pH 8.0 containing 50 mM SDS by using a fused silica capillary (50 m internal diameter, 72 cm effective length). The sample was injected hydrodynamically for 4 s at 50 mbar pressure and the applied voltage was +30 kV. The detection wavelength was set at 205 nm. Diflunisal was used as an internal standard. The analysis was performed at 25 °C and the total run time was 14 min. The method was suitably validated with respect to linearity range, limit of detection and quantification, precision, accuracy, specificity and robustness. The linear calibration range was 5–100 g mL–1 and the limit of detection was determined as 1 g mL–1. The method developed was successfully applied to the determination of piribedil in pharmaceutical formulations. The results were compared with a spectrophotometric method reported in the literature and no significant difference was found statistically.  相似文献   

8.
Park H  Jung S 《Electrophoresis》2005,26(20):3833-3838
Neutral cyclosophoraoses (Cys) and highly sulfated cyclosophoraoses (HS-Cys) were successfully applied as chiral selectors with SDS for the separation of some chiral flavonoids in MEKC. HS-Cys were synthesized by the chemical modification of a family of neutral Cys isolated from a soil microorganism, Rhizobium meliloti 2011. Chiral catechin was separated with a resolution (R(s)) of 0.754 by neutral Cys and SDS. In the case of isosakuranetin and neohesperidin, resolution (R(s)) values of 1.483 and 1.306 were obtained with HS-Cys and SDS, respectively.  相似文献   

9.
A vesicle-forming chiral cationic surfactant (1R,2S)-(-)-N-dodecyl-N-methyl-ephedrinium bromide was evaluated as a pseudo-stationary phase in micellar electrokinetic chromatography (MEKC) for enantioseparation of eight non-steroidal anti-inflammatory drugs e.g., carprofen, flurbiprofen, fenoprofen, ibuprofen, indoprofen, ketoprofen, naproxen and suprofen by capillary electrophoresis. The effects of varying experimental conditions such as pH and concentration of surfactant in the running buffer on the enantiomer separation of the drugs are reported. A mixture of five of the above drugs was separated and each enantiomeric pair was also separated simultaneously in a single run by use of the surfactant. The strong electrostatic interactions between the analytes and the vesicles seemed to have a major role in the enantiomeric separation of the profens.  相似文献   

10.
《Electrophoresis》2018,39(17):2202-2209
The synergistic effect of two acidic amino acids, aspartic and glutamic acid, on the electrophoretic enantioseparation of four basic drugs was evaluated in the BGE containing a CD and at different pHs. Chlorpheniramine, hydroxyzine, propranolol and tramadol were used as the basic model drugs. However, no enantioseparations were achieved with a BGE containing sole amino acid, but the combined use of an acidic amino acid and a CD showed improved enantioseparations (synergistic effect) compared with the single CD system. The results demonstrated that at optimized pH, the electrostatic interactions of the anionic amino acids with the positively charged basic drugs could result in a decrease of the analyte migration velocity and it consequently improved the enantioseparation. The effective parameters such as the amino acid and chiral selector type and concentration, buffer pH, applied voltage, and capillary temperature were optimized. Favorable enantiomeric resolution and migration times of the model drugs were achieved with a 100 mM phosphate buffer solution (pH 3.0) containing 5.0 mM HP‐α‐CD/HP‐β‐CD and 20 mM aspartic acid with an 18 kV applied voltage at 25°C. 1H NMR experiments were also carried out in a mixture of an analyte and CD in the absence and presence of aspartic acid. The NMR results were consistent with the results obtained by CE which showed the synergistic effect of amino acid.  相似文献   

11.
Summary Computer-assisted procedures for the one-parameter optimization of the surfactant concentration and the concentration of urea or D-glucose as modifiers in micellar electrokinetic capillary chromatography have been developed. These procedures permit a rapid optimization of one parameter on the basis of only two experiments. Predicted values are compared to empirically obtained optimum values. The influence of the modifier concentration on the critical micelle concentration of sodium dodecyl sulfate was experimentally determined in buffers commonly employed in micellar electrokinetic chromatography. The alteration of retention factors of solutes caused by the influence of urea addition on the critical micelle concentration of sodium dodecyl sulfate was calculated under the assumption of constant distribution coefficients and compared to experimentally obtained values. It was demonstrated that the addition of urea or of D-glucose does not alter the phase ratio substantially.  相似文献   

12.
13.
采用胶束扫集毛细管电动色谱技术,建立了测定药物中邻苯二甲酸二甲酯(DMP)、邻苯二甲酸二乙酯(DZP)和邻苯二甲酸二丁酯(DBP)的方法。电泳缓冲体系含80 mmol/L SDS,20 mmol/L NaH2PO4(pH 2.20),5%甲醇(V/V),分离电压-18 kV,重力进样80s×15.0cm,检测波长225 nm,使用Φ50μm×62.0 cm石英毛细管,有效长度50.0 cm。讨论了磷酸盐浓度、有机改善剂、SDS浓度、分离电压、进样时间等因素的影响,并考察了胶束扫集法对DMP、DEP和DBP的富集能力。在优化条件下,线性关系良好,相关系数大于0.9986,DMP、DEP和DBP的线性范围分别为1.25~240,1.04~200和1.56~200 mg/L,检出限分别为0.26,0.26和0.39 mg/L。方法应用于肠溶片中DMP、DEP和DBP的测定,回收率在93.3%~108%之间,RSD≤5.2%。每次样品测定可在10 min内完成。  相似文献   

14.
Summary Two modes of capillary electrophoresis (CE), capillary zone electrophoresis (CZE) and micellar electrokinetic chromatography (MEKC), were investigated for the separation of 12 aromatic sulphonate compounds. In CZE, although the voltage applied, the buffer concentration and the pH were optimized for effective separation of the compounds studied, under the best conditions four of the five amino compounds coeluted, as did naphthalene-1-sulphonic acid and naphthalene-2-sulphonic acid. In MEKC, sodium dodecyl sulphate (SDS) and Brij 35 were chosen as the anionic and nonionic surfactants and the effect of the concentration of micelles was examined. The effect of adding methanol as the organic modifier was also investigated with each of these micellar systems. All the analytes, including the isomers, were completely separated by use of MEKC with Brij 35 but when SDS was used only 11 compounds were separated because two amino compounds coeluted.  相似文献   

15.
Summary A simple and practical micellar electrokinetic capillary chromatography (MEKC) method is proposed for the quantitation of immunosuppressive drugs such as azathioprine (AZA), mycophenolate mofetil (MMF), cyclosporine A (CyA) and tacrolimus (FK 506). The electrophoretic separation of the analytes was performed with a background electrolyte containing 20 mM phosphate buffer at pH 7.5, 50 mM SDS and methanol as an organic modifier. Fused silica capillaries 75 μm i.d. and 60 cm in length were employed and detection of analytes was performed at 214 nm. Thorough validation according to international guidelines showed that the proposed method is reliable and appropiate for the routine analysis of immunosuppressants. Moreover, it may be an advantageous alternative to the traditional chromatographic methodologies currently employed in the pharmaceutical and bioanalysis fields.  相似文献   

16.
17.
Lan Zhang  Jinfeng Chen  Yu He  Guonan Chen 《Talanta》2009,77(3):1002-2154
A simple, rapid and low-costing new mixed surfactant MEKC method has been developed for the analysis of five neutral anabolic steroids in this paper. It was found that the bile salt coupling with Triton X-100 was a suitable bi-micellar surfactant for the separation of these anabolic steroids with similar structure. The separation conditions were optimized in detail. The five natural and synthetic anabolic steroids, such as androstenedione (AD), 19-norandrostenedione (NAD), 1,4-androstadiene-3,17-dione (ADD), methandrostenolone (MA) and methyltestosterone (MT) were separated and detected in an alkaline buffer system (pH 9.0) containing 15 mM Britton-Robinson (BR) buffer, 50 mM sodium cholate (SC) and 0.1% (v/v) Triton X-100 with detection wavelength at 241 nm and 18 kV of separation voltage. Under the optimal conditions, five coexistence neutral steroids were completely separated within 12 min with the detection limits ranged from 0.20 to 0.51 μg/mL. This method was successfully used for detection and confirmation of the anabolic steroid methandrostenolone in methandrostenolone tablets and in the real human urine, GC-MS method was applied to confirm the free methandrostenolone existence in the urine sample in order to validate the reliability of MEKC method.  相似文献   

18.
The limited peak capacity of neutral compounds in micellar electrokinetic chromatography (MEKC) causes peak overlap in a simple 38-compound sample that is predicted by statistical-overlap theory (SOT). The low-concentration sample was prepared in-house from several compound classes to span the entire migration-time range and was resolved partially in a pH=7 phosphate buffer containing 50 mM sodium dodecyl sulfate. Peaks, singlets, doublets, and other multiplets were identified on the basis of known migration times and were counted at 13 voltages spanning 4 – 26 kV. These numbers agreed well with predictions of a simple SOT based on the assumption of an inhomogeneous Poisson distribution of migration times. Because the dispersion theory of MEKC is simple, the standard deviations of single-component peaks were modeled theoretically. As part of a new way to implement SOT, probability distributions of the numbers of peaks, singlets, and so on, were computed by Monte Carlo simulation. These distributions contain all theoretical information on peak multiplicity predictable by SOT and were used to evaluate the agreement between experiment and theory. The peak capacity of MEKC was calculated numerically and substituted into the simplest equations in SOT, affirming that peak overlap arises from limited peak capacity.  相似文献   

19.
Summary A sensitive and selective laser-induced luminescence detection scheme for orotic acid in urine, separated by micellar electrokinetic capillary chromatography (MEKC) has been developed. The 325 nm line from a helium cadmium laser is used to excite orotic acid, which transfers its energy to terbium. Resultant luminescence of terbium is linear with orotic acid concentration over more than 2.5 orders of magnitude. This novel and practical system enables the detection of 50 nm orotic acid in urine in less than 1.5 minutes while using only nanoliters of sample. The significant decrease in analysis time over traditional methods (spectrophotometric and chromatographic) comes from the high efficiency of MEKC. A dramatic improvement in sensitivity and selectivity over UV detection in capillary electrophoresis is achieved through the use of laser-induced lanthanide ion energy transfer luminescence detection. Finally, no sample pretreatment is needed and the method is free from any known interferences in urine.  相似文献   

20.
Tao Wen  Guoan Luo  Jian Wang  Bo Yao  Jun Zhu 《Talanta》2007,71(2):854-860
Microemulsion electrokinetic chromatography (MEEKC) and solvent modified micellar electrokinetic chromatography (MEKC) were investigated with the goal of the rapid separation of complex heroin and amphetamine samples. The rapid simultaneous separation of 17 species of heroin, amphetamine and their basic impurities and adulterants was performed within about 10 min using MEEKC for the first time, whereas solvent modified MEKCs were unable to resolve all the components. The comparisons between MEEKC and solvent modified MEKC proved internal lipophilic organic phase in microemulsions played an important role in improving the separation performance with respect to efficiency. However, the role of internal lipophilic organic phase in MEEKC was disgusted at high concentrations of cosurfactant, and the separations of MEEKC and 1-butanol modified MEKC became similar at high concentrations of 1-butanol. The evaluation of reproducibility, linearity and detection limit of optimized MEEKC method provided good results for all the analytes investigated, thus allowing its application to real controlled drug preparation analysis.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏