首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
建立了高效液相色谱–四极杆飞行时间串联质谱快速检测饮料中糖精钠、甜蜜素、安赛蜜、阿斯巴甜、纽甜、三氯蔗糖6种人工合成甜味剂的方法。样品经水提取,采用C18色谱柱,以甲醇和0.1%甲酸–10 mmol/L甲酸铵溶液为流动相,梯度洗脱,四极杆飞行时间串联质谱电喷雾负离子模式检测。各化合物在0.02~2.0 mg/L范围内均呈现良好的线性关系,相关系数均大于0.998。样品平均添加回收率为63.0%~113.2%,测定结果的相对标准偏差均小于9.6%(n=5)。该方法简便快捷,选择性好,灵敏度高,可满足国内外现行法规的限量要求。  相似文献   

2.
An analytical method was developed for the analysis of sucralose, a persistent chlorinated calorie-free sugar substitute, in surface waters. The method is based on solid-phase extraction (SPE) of 400 mL water using Oasis HLB (Waters) adsorber material, followed by negative electrospray ionization (ESI) triple quadrupole LC–MS–MS detection. Quantification was performed by external calibration, as well as by isotope dilution with deuterated sucralose d6 internal standard. Extraction with Oasis HLB, a polymeric adsorbent suited for polar compounds, was much more efficient at neutral pH than at pH 3; a recovery of 62 ± 9% (n = 6; determined at 1 μg/L) could be achieved. Strong ion suppression caused by matrix substances was observed for sucralose in the SPE extracts. The analysis of 120 river surface water samples from 27 European countries showed that sucralose, which is in use in Europe since beginning 2005, can be found in the aquatic environment, at concentrations up to 1 μg/L. Sucralose was predominately found in samples from the UK, Belgium, the Netherlands, France, Switzerland, Spain, Italy, Norway, and Sweden, suggesting an increased use of the substance in Western Europe.  相似文献   

3.
A novel solid-phase extraction (SPE) method is presented whereby 15 basic, neutral and acidic pharmaceuticals in wastewater were simultaneously extracted and subsequently separated into different fractions. This was achieved using mixed-mode cation- and anion-exchange SPE (Oasis MCX and MAX) in series. Analysis was performed by high-performance liquid chromatography–quadrupole time-of-flight mass spectrometry (HPLC/QTOF-MS). A fast separation was achieved, with all compounds eluting within 6 min, narrow chromatographic peaks, with a peak base width of 6 s on average, and a high mass accuracy of quantified wastewater sample ions, with average mass errors in absolute value of 0.7 mDa or 2.7 ppm. The recovery of the SPE method in the analysis of sewage treatment plant (STP) influent and effluent wastewater was on average 80% and the ion suppression 30%. For less demanding samples Oasis MCX used alone may be an alternative method, although for STP influent waters containing high loads of organic compounds the clean-up achieved using only Oasis MCX was insufficient, leading to unreliable quantitation. Furthermore, serial SPE separation according to molecular charge added an additional degree of analyte confirmation. For quantitation, an approach combining external standard calibration curves, isotopically labelled surrogate standards and single-point standard addition was used. The applicability of the method was demonstrated in the analysis of influent and effluent wastewater from an STP, using small sample volumes (25–50 mL). The effluent wastewater had been subjected to three different treatments; activated sludge, activated sludge followed by ozonation, and a membrane bioreactor (MBR). Ozone treatment proved superior in removal of the analysed pharmaceuticals, while the MBR provided higher removal efficiencies than the activated sludge process.  相似文献   

4.
An alternative method for the sensitive determination of several drugs of abuse and some of their metabolites in surface and sewage water samples is proposed. Analytes are concentrated using a solid-phase extraction (SPE) sorbent, converted into the corresponding trimethylsilyl derivatives and selectively determined by gas chromatography (GC) with tandem mass spectrometry (MS/MS) detection. Parameters affecting the performance of extraction, derivatisation and determination steps are systematically investigated. Moreover, the stability of target analytes in sewage water samples is discussed. Under final working conditions, water samples were adjusted at pH 8.5 and concentrated using a 200 mg OASIS HLB SPE cartridge. Analytes were sequentially eluted with ethyl acetate followed by acetone and silylated using N-methyl-N-(trimethylsilyl)trifluoroacetamide (MSTFA). The reaction was completed in 60 min at 80 °C and the mixture injected directly in the GC–MS/MS system without further purification. In most cases, analytes presented a poor stability in sewage water samples; however, once they are submitted to the SPE process, cartridges can be stored at −20 °C for at least 3 months without significant degradation and/or inter-conversion reactions of illicit drugs. The proposed method provided recoveries over 74% and LODs between 0.8 and 15 ng/L for river and treated wastewater samples. In the case of raw wastewater slightly worse recoveries, between 63 and 137%, and similar LODs were attained. Analysis of a limited number of waste and surface water samples confirmed the presence of several illicit drugs in the aquatic environment, with the highest levels and frequency corresponding to benzoylecgonine, the main metabolite of cocaine.  相似文献   

5.
In this work, an ultra high-pressure liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method has been developed for the simultaneous quantification and confirmation of the 20 most consumed pharmaceuticals in Spain in urban wastewater and surface water samples. The scope of the method included acidic, neutral and basic compounds belonging to different therapeutic classes and allows their simultaneous determination in just a single injection, giving realistic information of the most widely consumed pharmaceuticals in only one analysis. An enrichment step based on solid-phase extraction using Oasis HLB cartridges was carried out, followed by UHPLC-MS/MS measurement with a fast-acquisition triple quadrupole mass analyzer. It allowed working with short dwell times and made possible to acquire three simultaneous SRM transitions per compound to assure a reliable identification. Several isotope-labelled internal standards were used as surrogates to correct SPE losses, as well as matrix effects that notably affect quantification of analytes. The method was validated in surface water and effluent and influent urban wastewater at different concentrations from 0.005 μg/L (surface water) to 1.25 μg/L (influent wastewater). The optimized method was applied to the analysis of 84 urban wastewater samples (influent and effluent), with the result that 17 out of 20 compounds monitored were detected in the samples. Analgesics and anti-inflamatories, cholesterol lowering statin drugs and lipid regulators were the major groups found, with diclofenac, ketoprofen, naproxen, 4-aminoantipyrine, bezafibrate, gemfibrozil and venlafaxine being the most frequently detected. The highest concentration level reached was 277 μg/L for salicylic acid in influent wastewater.  相似文献   

6.
A new solid phase extraction (SPE) method coupled to a high throughput sample analysis technique was developed for the simultaneous determination of nine selected emerging contaminants in wastewater (atrazine, desethylatrazine, 17β-estradiol, ethynylestradiol, norethindrone, caffeine, carbamazepine, diclofenac and sulfamethoxazole). We specifically included pharmaceutical compounds from multiple therapeutic classes, as well as pesticides. Sample pre-concentration and clean-up was performed using a mixed-mode SPE cartridge (Strata ABW) having both cation and anion exchange properties, followed by analysis by laser diode thermal desorption atmospheric pressure chemical ionization coupled to tandem mass spectrometry (LDTD-APCI-MS/MS). The LDTD interface is a new high-throughput sample introduction method, which reduces total analysis time to less than 15 s per sample as compared to minutes with traditional liquid-chromatography coupled to tandem mass spectrometry (LC–MS/MS). Several SPE parameters were evaluated in order to optimize recovery efficiencies when extracting analytes from wastewater, such as the nature of the stationary phase, the loading flow rate, the extraction pH, the volume and composition of the washing solution and the initial sample volume. The method was successfully applied to real wastewater samples from the primary sedimentation tank of a municipal wastewater treatment plant. Recoveries of target compounds from wastewater ranged from 78% to 106%, the limit of detection ranged from 30 to 122 ng L−1 while the limit of quantification ranged from 90 to 370 ng L−1. Calibration curves in the wastewater matrix showed good linearity (R2 ≥ 0.991) for all target analytes and the intraday and interday coefficient of variation was below 15%, reflecting a good precision.  相似文献   

7.
This paper describes the development of a multi-residue method for the determination of 36 emerging organic pollutants (26 biocides, 5 UV-filters and 5 benzothiazoles) in raw and treated wastewater, activated sludge and surface water using liquid chromatography–tandem mass spectrometry (LC–MS/MS). The target analytes were enriched from water samples adjusted to pH 6 by solid-phase extraction (SPE) on Oasis HLB 200 mg cartridges and eluted with a mixture of methanol and acetone (60/40, v/v). Extraction of freeze-dried sludge samples was accomplished by pressurized liquid extraction (PLE) using a mixture of methanol and water (50/50, v/v) as extraction solvent followed by SPE. LC–tandem MS detection was compared using electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI) in positive and negative ionization mode. ESI exhibited strong ion suppression for most target analytes, while APCI was generally less susceptible to ion suppression but partially leading to ion enhancement of up to a factor of 10. In general, matrix effects could be compensated using stable isotope-labeled surrogate standards, indicated by relative recoveries ranging from 70% to 130%. In wastewater, activated sludge and surface water up to 33 analytes were detected. Maximum concentrations up to 5.1 and 3.9 μg L−1 were found in raw wastewater for the water-soluble UV-filters benzophenone-4 (BZP-4) and phenylbenz-imidazole sulfonic acid (PBSA), respectively. For the first time, the anti-dandruff climbazole was detected in raw wastewater and in activated sludge with concentrations as high as 1.4 μg L−1 and 1.2 μg g TSS−1, respectively. Activated sludge is obviously a sink for four benzothiazoles and two isothiazolones, as concentrations were detected in activated sludge between 120 ng g TSS−1 (2-n-octyl-4-isothiazolin-3-one, OIT) to 330 ng g TSS−1 (benzothiazole-2-sulfonic acid, BTSA).  相似文献   

8.
A simple, precise, and accurate hydrophilic interaction liquid chromatographic (HILIC) method has been developed for the determination of five aromatic amines in environmental water samples. Chromatography was carried out on a bare silica column, using a mixture of acetonitrile and a buffer of NaH2PO4–H3PO4 (pH 1.5, containing 10 mM NaH2PO4) (85:15, v/v) as a mobile phase at a flow rate of 1 mL min−1. Aromatic amines were detected by UV absorbance at 254 nm. The linear range of amines was good (r2 > 0.998) and limit of detection (LOD) within 0.02–0.2 mg L−1 (S/N = 3). The retention mechanism for the analytes under the optimum conditions was determined to be a combination of adsorption, partition and ionic interactions. The proposed method was applied to the environmental water samples. Aromatic amines were isolated from aqueous samples using solid-phase extraction (SPE) with Oasis HLB cartridges. Recoveries of greater than 75% with precision (RSD) less than 12% were obtained at amine concentrations of 5–50 μg L−1 from 100 mL river water and influents from a wastewater treatment plant (WWTP). The present HILIC technique proved to be a viable method for the analysis of aromatic amines in the environmental water samples.  相似文献   

9.
This work presents a new extraction material, namely, Q‐100, based on hypercrosslinked magnetic particles, which was tested in dispersive solid‐phase extraction for a group of sweeteners from environmental samples. The hypercrosslinked Q‐100 magnetic particles had the advantage of suitable pore size distribution and high surface area, and showed good retention behavior toward sweeteners. Different dispersive solid‐phase extraction parameters such as amount of magnetic particles or extraction time were optimized. Under optimum conditions, Q‐100 showed suitable apparent recovery, ranging in the case of river water sample from 21 to 88% for all the sweeteners, except for alitame (12%). The validated method based on dispersive solid‐phase extraction using Q‐100 followed by liquid chromatography with tandem mass spectrometry provided good linearity and limits of quantification between 0.01 and 0.1 μg/L. The method was applied to analyze samples from river water and effluent wastewater, and four sweeteners (acesulfame, saccharin, cyclamate, and sucralose) were found in both types of sample.  相似文献   

10.
Three preconcentration techniques including solid phase extraction (SPE), dispersive liquid-liquid microextraction (DLLME) and stir-bar sorptive extraction (SBSE) have been optimized and compared for the analysis of six hypolipidaemic statin drugs (atorvastatin, fluvastatin, lovastatin, pravastatin, rosuvastatin and simvastatin) in wastewater and river water samples by high performance liquid chromatography coupled to quadrupole-time-of-flight mass spectrometry (HPLC/Q-TOF-MS). Parameters that affect the efficiency of the different extraction methods such as solid phase material, sample pH and elution solvent in the case of SPE; the type and volume of the extracting and dispersive solvent, pH of sample, salt addition and number of extraction steps in the case of DLLME; and the stirring time, pH of sample, sample volume and salt addition for SBSE were evaluated. SPE allowed the best recoveries for most of the analytes. Pravastatin was poorly extracted by DLLME and could not be determined. SBSE was only applicable for lovastatin and simvastatin. However, despite the limitations of having poorer recovery than SPE, DLLME and SBSE offered some advantages because they are simple, require low organic solvent volumes and present low matrix effects. DLLME required less time of analysis, and for SBSE the stir-bar was re-usable. SPE, DLLME and SBSE provided method detection limits in the range of 0.04-11.2 ng L−1, 0.10-17.0 ng L−1 for 0.52-2.00 ng L−1, respectively, in real samples. To investigate and compare their applicability, SPE, DLLME and SBSE procedures were applied to the detection of statin drugs in effluent wastewater and river samples.  相似文献   

11.
A method using automated on-line solid phase extraction (SPE) directly coupled to liquid chromatography/tandem mass spectrometry (LC-MS/MS) has been developed for the analysis of six pharmaceuticals by isotope dilution. These selected pharmaceuticals were chosen as representative indicator compounds and were used to evaluate the performance of the on-line SPE method in four distinct water matrices. Method reporting limits (MRLs) ranged from 10 to 25 ng/L, based on a 1 mL extraction volume. Matrix spike recoveries ranged from 88 to 118% for all matrices investigated, including finished drinking water, surface water, wastewater effluent and septic tank influent. Precision tests were performed at 50 and 1000 ng/L with relative standard deviations (RSDs) between 1.3 and 5.7%. A variety of samples were also extracted using a traditional off-line automated SPE method for comparison. Results for both extraction methods were in good agreement; however, on-line SPE used approximately 98% less solvent and less time. On-line SPE coupled to LC-MS/MS analysis for selected indicators offers an alternative, more environmentally friendly, method for pharmaceutical analysis in water by saving time and costs while reducing hazardous waste and potential environmental pollution as compared with off-line SPE methods.  相似文献   

12.
A method for the simultaneous determination of seven commonly used artificial sweeteners in water is presented. The analytes were extracted by solid phase extraction using Bakerbond SDB 1 cartridges at pH 3 and analyzed by liquid chromatography electrospray ionization tandem mass spectrometry in negative ionization mode. Ionization was enhanced by post-column addition of the alkaline modifier Tris(hydroxymethyl)amino methane. Except for aspartame and neohesperidin dihydrochalcone, recoveries were higher than 75% in potable water with comparable results for surface water. Matrix effects due to reduced extraction yields in undiluted waste water were negligible for aspartame and neotame but considerable for the other compounds. The widespread distribution of acesulfame, saccharin, cyclamate, and sucralose in the aquatic environment could be proven. Concentrations in two influents of German sewage treatment plants (STPs) were up to 190 μg/L for cyclamate, about 40 μg/L for acesulfame and saccharin, and less than 1 μg/L for sucralose. Removal in the STPs was limited for acesulfame and sucralose and >94% for saccharin and cyclamate. The persistence of some artificial sweeteners during soil aquifer treatment was demonstrated and confirmed their environmental relevance. The use of sucralose and acesulfame as tracers for anthropogenic contamination is conceivable. In German surface waters, acesulfame was the predominant artificial sweetener with concentrations exceeding 2 μg/L. Other sweeteners were detected up to several hundred nanograms per liter in the order saccharin ≈ cyclamate > sucralose. Figure Some artificial sweeteners are excreted unchanged and in particular acesulfame is a perfect tracer for municipal waste water Electronic supplementary material  The online version of this article (doi:) contains supplementary material, which is available to authorized users.  相似文献   

13.
A novel multi-templates molecularly imprinted polymer (MIP), using acidic pharmaceuticals mixture (ibuprofen (IBP), naproxen (NPX), ketoprofen (KEP), diclofenac (DFC), and clofibric acid (CA)) as the template, was prepared as solid-phase extraction (SPE) material for the quantitative enrichment of acidic pharmaceuticals in environmental samples and off-line coupled with liquid chromatography–mass spectrometry (LC/MS/MS). Washing solvent was optimized in terms of kind and volume for removing the matrix constituents nonspecifically adsorbed on the MIP. When 1 L of water sample spiked at 1 μg/L was loaded onto the cartridge, the binding capacity of the MIP cartridge were 48.7 μg/g for KEP, 60.7 μg/g for NPX, 52 μg/g for CA, 61.3 μg/g for DFC and 60.7 μg/g for IBP, respectively, which are higher than those of the commercial single template MIP in organic medium (e.g. toluene) reported in the literature. Recoveries of the five acidic pharmaceuticals extracted from 1 L of real water samples such as lake water and wastewater spiked at 1 μg/L were more than 95%. The recoveries of acidic pharmaceuticals extracted from 10-g sediment sample spiked at the 10 ng/g level were in the range of 77.4–90.6%. To demonstrate the potential of the MIP obtained, a comparison with commercial C18 SPE cartridge was performed. Molecularly imprinted solid-phase extraction (MISPE) cartridge showed higher recoveries than commercial C18 SPE cartridge for acidic pharmaceuticals. These results showed the suitability of the MISPE method for the selective extraction of a group of structurally related compounds such as acidic pharmaceuticals.  相似文献   

14.
The paper reports a direct method for the determination of pyridine in water and wastewater samples based on ultraviolet spectrophotometric measurements using multi-way modeling techniques. Parallel factor analysis (PARAFAC) and multi-way partial least squares (N-PLS) regression methods were employed for the decomposition of spectra and quantification of pyridine. The study was carried out in the pH range of 1.0-12.0 and concentration range of 0.67-51.7 μg mL−1 of pyridine. Both the three-way PARAFAC and tri-PLS1 models successfully predicted the concentration of pyridine in synthetic (spiked) river water and field wastewater samples. The mean recovery obtained from PARAFAC regression model were 97.39% for the spiked and 99.84% for the field wastewater samples, respectively. The sensitivity and precision of the method for pyridine determination were 0.58% and 5.95%, respectively. The N-PLS regression model yielded mean recoveries of 99.29% and 100.18% for the spiked and field wastewater samples, respectively. The prediction accuracy of the methods was evaluated through the root mean square error of prediction (RMSEP). For PARAFAC, it was 0.65 and 0.82 μg mL−1 for spiked river water and field wastewater samples, respectively, while for N-PLS, it was 0.25 and 0.37 μg mL−1, respectively. Both the PARAFAC and N-PLS methods, thus, yielded satisfactory results for the prediction of pyridine concentration in water and wastewater samples.  相似文献   

15.
An alternative analysis technique for the quantitation of 15 poly- and perfluoroalkyl substances (PFASs) in water matrices is reported. Analysis time between each sample was reduced to less than 20 s, all target molecules being analyzed in a single run with the use of laser diode thermal desorption atmospheric pressure chemical ionization (LDTD/APCI) coupled with high resolution accurate mass (HRMS) orbitrap mass spectrometry. LDTD optimal settings were investigated using either one-factor-at-a-time or experimental design methodologies, while orbitrap parameters were optimized simultaneously by means of a Box–Behnken design. Following selection of an adequate sample concentration and purification procedure based on solid-phase extraction and graphite clean-up, the method was validated in an influent wastewater matrix. Environmentally significant limits of detection were reported (0.3–4 ng L−1 in wastewater and 0.03–0.2 ng L−1 in surface water) and out of the 15 target analytes, 11 showed excellent accuracies (±20% of the target values) and recovery rates (75–125%). The method was successfully applied to a selection of environmental samples, including wastewater samples in 7 locations across Canada, as well as surface and tap water samples from the Montreal region, providing insights into the degree of PFAS contamination in this area.  相似文献   

16.
A molecularly imprinted polymer (MIP) designed to enable the selective extraction of carbamazepine (CBZ) from effluent wastewater and urine samples has been synthesised using a non-covalent molecular imprinting approach. The MIP was evaluated chromatographically in the first instance and its affinity for CBZ also confirmed by solid-phase extraction (SPE). The optimal conditions for SPE consisted of conditioning of the cartridge using acidified water purified from a Milli-Q system, loading of the sample under basic aqueous conditions, clean-up using acetonitrile and elution with methanol. The attractive molecular recognition properties of the MIP gave rise to good CBZ recoveries (80%) when 100 mL of effluent water spiked with 1 μg L−1 was percolated through the polymer. For urine samples, 2 mL samples spiked with 2.5 μg L−1 CBZ were extracted with a recovery of 65%. For urine, the linear range was 0.05-24 mg L−1, the limit of detection was 25 μg L−1 and precision, expressed as relative standard deviation at 0.5 mg L−1 (n = 3), was 3.1% and 12.6% for repeatability and reproducibility between days, respectively.  相似文献   

17.
This study presents the development of an automated on-line solid phase extraction (SPE)-liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the determination of 23 antibiotics in environmental water samples. After optimisation of LC-MS/MS conditions, SPE parameters such as sorbent type, sample pH or sample volume were optimised. Antibiotic recoveries ranged from 64% to 98% and compared favourably with those achieved using off-line SPE. Limits of detection were in the range 0.5-13.7 ng L−1.This on-line SPE-LC-MS/MS procedure was applied to the analysis of water samples taken in three rivers within the Seine River basin, near Paris (France). The obtained results revealed the occurrence of 12 antibiotics, including tylosin, erythromycin, tetracycline, amoxicillin, trimethoprim, sulfamethoxazole, oxolinic acid, flumequine, norfloxacin, ciprofloxacin, ofloxacin, and vancomycin (2-1435 ng L−1).  相似文献   

18.
We describe the development and validation of an on-line solid-phase extraction of large-volume injections coupled to liquid chromatography-tandem mass spectrometry method for the simultaneous quantitation and confirmation of 14 selected trace organic contaminants in drinking and surface water. Selected compounds were: anti-infectives (clarithromycin, sulfamethoxazole and trimethoprim), an anticonvulsant (carbamazepine) and its transformation product 10,11-dihydrocarbamazepine, an antihypertensive (enalapril), antineoplastics (cyclophosphamide and methotrexate), herbicides (atrazine, cyanazine, and simazine) and two of their transformation products (deethylatrazine and deisopropylatrazine) and an antiseptic (triclocarban). The breakthrough volume determinations showed that out of all the investigated sorbents, the Strata-X on-line solid-phase extraction column showed the best performance. The method used a load volume of 10.0 mL and was validated using the corresponding matrices, yielding for most compounds, R2 > 0.99. Extraction recoveries ranged from 60 to 109%. The intra- and inter-day precision were <14 and <16%, respectively. The method detection limits ranged from 0.6 to 6 ng L−1. Matrix effects were in general low. The performance of the on-line method was demonstrated with the analysis of real water samples. The application of alternative techniques of confirmation was also explored using accurate mass measurements on a time-of-flight mass spectrometer and the data-dependent reverse energy ramp scan on a triple quadrupole.  相似文献   

19.
唐吉旺  袁列江  肖泳  王秀  王淑霞 《色谱》2019,37(6):619-625
建立了固相萃取-高效液相色谱-串联质谱快速检测食品中安赛蜜、糖精钠、甜蜜素、三氯蔗糖、阿斯巴甜、阿力甜、纽甜、甘素及新橙皮甙二氢查尔酮等9种人工合成甜味剂的方法。样品中的甜味剂经三乙胺缓冲溶液(pH 4.5)提取,采用亲水亲脂平衡填料固相萃取柱净化,经Phenomenex Knietex® F5色谱柱(100 mm×2.1 mm,2.6 μm)分离,以0.1%(v/v)甲酸-5 mmol/L甲酸铵溶液和甲醇为流动相,进行梯度洗脱,以电喷雾离子源正负离子切换多反应监测(MRM)模式进行质谱检测。采用内标法定量,进一步降低样品基质效应的影响。结果表明:本方法在去除样品基质干扰方面取得良好效果,9种甜味剂的检出限和定量限分别在2~30 μg/L和6~100 μg/L之间,在各自的线性范围内线性关系良好(相关系数r2>0.999)。9种甜味剂空白样品在3个水平下的加标回收率在86.3%~106.3%之间,相对标准偏差(RSD)在1.2%~5.9%之间。本方法快捷、高效、准确可靠,可用于复杂食品基质中9种人工合成甜味剂的快速检测。  相似文献   

20.
A. Hibberd 《Talanta》2009,77(4):1315-8272
This paper describes an improved method for the extraction and analysis of seven endocrine disrupting chemicals with wide-ranging polarities from water and sediments using gas chromatography-tandem mass spectrometry (GC-MS/MS). The analytes were 4-tert-octylphenol, 4-nonylphenol, bisphenol A, estrone, 17β-estradiol, 17α-ethynylestradiol and 16α-hydroxyestrone. The optimised GC-MS/MS method produces increased selectivity and sensitivity compared to GC-MS, with limit of detection ranging from 0.01 to 0.49 ng L−1 in water and from 0.05 to 0.14 ng g−1 in sediment. Extraction from aqueous samples was performed by solid-phase extraction (SPE) and from sediment samples by microwave-assisted extraction (MAE). The improved method for the clean-up of sediment extracts carried out by SPE enhanced EDC recovery (86-102%) while reducing matrix interference and sample drying time. Derivatisation of final sample extracts was achieved using N,O-bis(trimethylsilyl)trifluoroacetamide and pyridine, and their stability was enhanced by reconstituting the derivatised extracts with hexane. The method was validated by spiking experiments which showed good recovery and reproducibility. The method was applied to samples taken from the Medway estuary in Kent, UK, where non-conservative behaviour of EDCs was demonstrated.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号