首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到18条相似文献,搜索用时 15 毫秒
1.
A method for the determination of polymer additives like antioxidants, UV absorbers and processing stabilizers using liquid chromatography (LC) coupled with atmospheric pressure photoionization mass spectrometry (APPI-MS) is presented. Ion source parameters were optimized regarding temperatures, gas flow rates, and voltages applied. Detection limits were determined using APPI with or without dopant and were compared with electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI). Differences between APPI, ESI and APCI are pointed out and the effect of the dopant toluene and acetone is discussed. The optimized method yielded detection limits between 0.001 mg L−1 and 0.022 mg L−1 for 15 different analytes. Linear calibration plots could be obtained for all solutes over a wide concentration range showing satisfying repeatability with standard deviations of peak areas between 3.4% and 7.6%. The results indicate that the developed method can be regarded as suitable for the quantitative determination of polymer additives even at low concentration levels.  相似文献   

2.
Although the coupling of GC/MS with atmospheric pressure ionization (API) has been reported in 1970s, the interest in coupling GC with atmospheric pressure ion source was expanded in the last decade. The demand of a “soft” ion source for preserving highly diagnostic molecular ion is desirable, as compared to the “hard” ionization technique such as electron ionization (EI) in traditional GC/MS, which fragments the molecule in an extensive way. These API sources include atmospheric pressure chemical ionization (APCI), atmospheric pressure photoionization (APPI), atmospheric pressure laser ionization (APLI), electrospray ionization (ESI) and low temperature plasma (LTP). This review discusses the advantages and drawbacks of this analytical platform. After an introduction in atmospheric pressure ionization the review gives an overview about the history and explains the mechanisms of various atmospheric pressure ionization techniques used in combination with GC such as APCI, APPI, APLI, ESI and LTP. Also new developments made in ion source geometry, ion source miniaturization and multipurpose ion source constructions are discussed and a comparison between GC-FID, GC-EI-MS and GC-API-MS shows the advantages and drawbacks of these techniques. The review ends with an overview of applications realized with GC-API-MS.  相似文献   

3.
In this work new high performance liquid chromatographic methods in combination with mass spectrometry have been developed for the quantitation of hindered amine light stabilizers (HALS) which are commonly used as monomeric and oligomeric species for stabilization of plastic materials. These analytes are difficult to separate under traditional reversed phase conditions. In the present study new silica-based pH stable reversed phases that had become available recently were investigated for HALS analysis, and turned out to be well suited employing mobile phases at a pH of around 11 adjusted by addition of ammonia. Detection was done by mass spectrometry employing both time-of-flight and triple quadrupole mass analyzers. The performance of electrospray ionization (ESI) as well as atmospheric pressure photoionization (APPI) was investigated and compared. Despite the high pH of the mobile phase, an excellent ionization could be obtained in the positive ion mode. ESI provided slightly lower limits of quantitation (on average a factor of 2) in comparison with APPI. The method allowed the quantitation of a range of different HALS down to 0.05–0.005% (depending on the HALS) in polymeric materials. Sample preparation consisted in dissolving the sample in toluene and precipitation of the polymer with acetone. The procedure can be routinely applied to aging tests of plastic materials in order to predict the lifetime of plastic components.  相似文献   

4.
Eight polybrominated diphenyl ether (PBDE) congeners of primary interest to the US EPA were separated using reverse-phase liquid chromatography on an octadecylsilane column. BDE-28, BDE-47, BDE-99, BDE-100, BDE-153, BDE-154, BDE-183, and BDE-209 were baseline-resolved under isocratic conditions in 92:8 methanol/water (v/v). Negative-ion atmospheric pressure photoionization (NI-APPI) with a toluene dopant produced precursor ions corresponding to [M–Br+O] for the eight congeners studied. Each congener was quantified by tandem mass spectrometry through a unique multiple reaction monitoring (MRM) transition. On-column limits of detection were between 2.4 and 27.8 pg for the eight congeners studied, with an intra-day method precision of 9%. The LC/NI-APPI/MS/MS method was validated for the analysis of the eight PBDE congeners in NIST SRM 2585 (Organics in House Dust). Pressurized liquid extraction (PLE) with subsequent LC/NI-APPI/MS/MS analysis afforded quantitative recovery for all eight PBDE congeners with recoveries ranging from 92.7 to 113%. The liquid-phase separation of the LC/NI-APPI/MS/MS method is not prone to the thermal degradation issues that plague splitless GC based analyses of highly brominated PBDEs such as BDE-209.  相似文献   

5.
Summary This study demonstrated the utility of high-performance liquid chromatography/atmospheric pressure ionization mass spectrometry (HPLC/API-MS) in the investigation of 10-methoxy-1,6-dimethylergoline-8-methanol 5-bromonicotinic acid ester (Nicergoline) and its related substances. The analysis was performed by using an ODS column with ammonium acetate and methanol mixture as the mobile phase. Nicergoline and its related compounds could be characterized by HPLC/API-MS in terms of their molecular weight. The use of multiple ion detection techniques for the quantitation of these compounds was also investigated. The detection limits of nicergoline and its related substances were 5 to 10 ng each at a signal-to-noise ratio of 4. The method was also applied to the study of the decomposition products of nicergoline in simulated gastric and intestinal fluids.  相似文献   

6.
Polycyclic aromatic hydrocarbons (PAHs) are common pollutants present in atmospheric aerosols and other environmental mixtures. They are of particular air quality and human health concerns as many of them are carcinogenic toxins. They also affect absorption of solar radiation by aerosols, therefore contributing to the radiative forcing of climate. For environmental chemistry studies, it is advantageous to quantify PAH components using the same analytical technics that are commonly applied to characterize a broad range of polar analytes present in the same environmental mixtures. Liquid chromatography coupled with photodiode array and high-resolution mass spectrometric detection (LC-PDA-HRMS) is a method of choice for comprehensive characterization of chemical composition and quantification of light absorption properties of individual organic compounds present in the environmental samples. However, quantification of non-polar PAHs by this method is poorly established because of their imperfect ionization in electrospray ionization (ESI) technique. This tutorial article provides a comprehensive evaluation of the quantitative analysis of 16 priority pollutant PAHs in a standard reference material using the LC–MS platform coupled with the ESI source. Results are further corroborated by the quantitation experiments using an atmospheric pressure photoionization (APPI) method, which is more sensitive for the PAH detection. The basic concepts and step-by-step practical guidance for the PAHs quantitative characterization are offered based on the systematic experiments, which include (1) Evaluation effects of different acidification levels by formic acid on the (+)ESI-MS detection of PAHs. (2) Comparison of detection limits in ESI+ versus APPI+ experiments. (3) Investigation of the PAH fragmentation patterns in MS2 experiments at different collision energies. (4) Calculation of wavelength dependent mass absorption coefficient (MACλ) of the standard mixture and its individual PAHs using LC-PDA data. (5) Assessment of the minimal injected mass required for accurate quantification of MACλ of the standard mixture and of a multi-component environmental sample.  相似文献   

7.
An ultra-sensitive liquid chromatography/tandem mass spectrometry (LC/MS/MS) method for the analysis of oral contraceptive ethinyl estradiol (EE) was developed and validated over the curve range of 2.5-500 pg/mL using 1 mL of human plasma sample. Ethinyl estradiol and the internal standard, ethinyl estradiol tetra-deuterated (EE-d4), were extracted from the plasma matrix with methyl t-butyl ether, derivatized with dansyl chloride and then back-extracted into hexane. The hexane phase was evaporated to dryness, reconstituted and injected onto the LC/MS/MS system. The chromatographic separation was achieved on a Luna C(18) column (50 x 2 mm, 5 micro m) with an isocratic mobile phase of 20:80 (v/v) water:acetonitrile with 1% formic acid. The offline derivatization procedure introduced the easily ionizable tertiary amine function group to EE. This greatly improved analyte sensitivity in electrospray ionization and enabled us to achieve the desired lower limit of quantitation at 2.5 pg/mL. This high sensitivity method can be used for therapeutic drug monitoring or supporting bio-equivalence and drug-drug interaction studies in human subjects.  相似文献   

8.
The Quick Easy Cheap Effective Rugged and Safe multiresidue method (QuEChERS) has been validated for the extraction of 80 pesticides belonging to various chemical classes from various types of representative commodities with low lipid contents. A mixture of 38 pesticides amenable to gas chromatography (GC) were quantitatively recovered from spiked lemon, raisins, wheat flour and cucumber, and determined using gas chromatography-tandem mass spectrometry (GC-MS/MS). An additional mixture of 42 pesticides were recovered from oranges, red wine, red grapes, raisins and wheat flour, using liquid chromatography-tandem mass spectrometry (LC-MS/MS) for determination. The pesticides chosen for this study included many of the most frequently detected ones and/or those that are most often found to violate the maximum residue limit (MRL) in food samples, some compounds that have only recently been introduced, as well as a few other miscellaneous compounds. The method employed involved initial extraction in a water/acetonitrile system, an extraction/partitioning step after the addition of salt, and a cleanup step utilizing dispersive solid-phase extraction (D-SPE); this combination ensured that it was a rapid, simple and cost-effective procedure. The spiking levels for the recovery experiments were 0.005, 0.01, 0.02 and 0.2 mg kg(-1) for GC-MS/MS analyses, and 0.01 and 0.1 mg kg(-1) for LC-MS/MS analyses. Adequate pesticide quantification and identity confirmation were attained, even at the lowest concentration levels, considering the high signal-to-noise ratios, the very good accuracies and precisions, as well as the good matches between the observed ion ratios. Mean recoveries mostly ranged between 70 and 110% (98% on average), and relative standard deviations (RSD) were generally below 10% (4.3% on average). The use of analyte protectants during GC analysis was demonstrated to provide a good alternative to the use of matrix-matched standards to minimize matrix-effect-related errors. Based on these results, the methodology has been proven to be highly efficient and robust and thus suitable for monitoring the MRL compliance of a wide range of commodity/pesticide combinations.  相似文献   

9.
柱前荧光衍生脂肪醇的高效液相色谱分离及质谱鉴定   总被引:1,自引:0,他引:1  
利用新型荧光试剂1,2-苯并-3,4-二氢咔唑-9-乙酸(BCAA)作为柱前衍生化试剂,以乙腈为溶剂,1-乙基-3-(3-二甲氨基丙基)环己碳二亚胺(EDAC)作为缩合剂,4-二甲氨基吡啶(DMAP)为催化剂,55℃下衍生反应25 min后获得稳定的荧光产物。在Eclipse XDB-C8色谱柱上,通过梯度洗脱对12种游离脂肪醇进行了分离和在线质谱定性。激发和发射波长分别为λex=333 nm,λem=390nm。采用大气压化学电离源(APCI)正离子模式,对洗发水(含十二烷基硫酸钠)中游离脂肪醇进行定性及测定。脂肪醇的线性回归相关系数大于0.9997,检出限在9.40-25.32 fmol。  相似文献   

10.
We report herein an extraction method for the analysis of perfluorinated compounds in human serum based on magnetic core–mesoporous shell microspheres with decyl-perfluorinated interior pore-walls (Fe3O4@mSiO2-F17). Thanks to the unique properties of the Fe3O4@mSiO2-F17 microspheres, macromolecules like proteins could be easily excluded from the mesoporous channels due to size exclusion effect, and perfluorinated compounds (PFCs) in protein-rich biosamples such as serum could thus be directly extracted with the fluorocarbon modified on the channel wall without any other pretreatment procedure. The PFCs adsorbed Fe3O4@mSiO2-F17 microspheres could then be simply and rapidly isolated by using a magnet, followed by being identified and quantified by LC–MS/MS (high-performance liquid chromatography coupled to tandem mass spectrometry). Five perfluorinatedcarboxylic acids (C6, C8–C11) and perfluorooctane sulfonate (PFOS) were selected as model analytes. In order to achieve the best extraction efficiency, some important factors including the amount of Fe3O4@mSiO2-F17 microspheres added, adsorption time, type of elution solvent, eluting solvent volume and elution time were investigated. The ranges of the LOD were 0.02–0.05 ng mL−1 for the six PFCs. The recovery of the optimized method varies from 83.13% to 92.42% for human serum samples.  相似文献   

11.
An analytical method using liquid chromatography‐atmospheric pressure photoionization tandem mass spectrometry with toluene as a dopant was developed for the determination of triterpenes in medicinal plant extracts. The 12 compounds determined have been shown to exhibit biological activity, such as gastroprotective, hepatoprotective, anti‐inflammatory, antiviral and anti‐tumor effects. The parameters of the atmospheric pressure photoionization interface were optimized to obtain the highest possible sensitivity for all of the compounds. The limits of detection and quantification ranged from 0.4 to 157.9 µg l?1 and 1.3 to 526.4 µg l?1, respectively. The method was validated and applied to extracts of five medicinal plants species (Mansoa alliacea (Lam.) A.H.Gentry, Bauhinia variegata var variegata, Bauhinia variegata var alboflava, Cecropia obtuse Trécul and Cecropia palmate Willd) from the Amazonian region. The concentrations of the six triterpenes quantified in the samples ranged from 0.424 mg kg?1 for ursolic acid to 371.96 mg kg?1 for β‐amyrin, which were quantified by using the standard addition method (n = 3). Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

12.
Biological functions in organisms are usually controlled by a set of interacting proteins, and identifying the proteins that interact is useful for understanding the mechanism of the functions. Immunoprecipitation is a method that utilizes the affinity of an antibody to isolate and identify the proteins that have interacted in a biological sample. In this study, the FD‐LC–MS/MS method, which involves fluorogenic derivatization followed by separation and quantification by HPLC and finally identification of proteins by HPLC–tandem mass spectrometry, was used to identify proteins in immunoprecipitated samples, using heat shock protein 90 (HSP90) as a model of an interacting protein in HepaRG cells. As a result, HSC70 protein, which was known to form a complex with HSP90, was isolated, together with three different types of HSP90‐beta. The results demonstrated that the proposed immunoaffinity–FD‐LC–MS/MS method could be useful for simultaneously detecting and identifying the proteins that interact with a certain protein.  相似文献   

13.
A simple and sensitive method for the analysis of sterols, tocopherols and triterpenic dialcohols from the unsaponifiable fraction from oil samples in a single analytical run using liquid chromatography coupled to mass spectrometry was developed. With this method, the compounds could be detected directly after dissolving the unsaponifiable fraction in acetonitrile without necessity of time-consuming sample pre-treatment or derivatization. Separation of the analytes was carried out at room temperature, by using a C18 column (5 μm i.d. 3.0 mm × 250 mm) with a linear gradient of acetonitrile/water (0.01% acetic acid) at a flow rate of 1.5 mL/min. The full scan mass spectra of the investigated compounds were measured by an ion trap mass spectrometer equipped with an APCI ion source. The optimized methodology was suitable for the identification of 23 compounds belonging to different families present in olive oil and other kinds of oils, as well as for the quantification of 15 analytes (vs. their commercial standards).  相似文献   

14.
Tigecycline (TIG), a derivative of minocycline, is the first in the novel class of glycylcyclines and is currently indicated for the treatment of complicated skin structure and intra‐abdominal infections. A selective, accurate and reversed‐phase high‐performance liquid chromatography‐tandem mass spectrometry (HPLC‐MS/MS) method was developed for the determination of TIG in rat brain tissues. Sample preparation was based on protein precipitation and solid phase extraction using Supel‐Select HLB (30 mg/1 mL) cartridges. The samples were separated on a YMC Triart C18 column (150 mm x 3.0 mm. 3.0 µm) using gradient elution. Positive electrospray ionization (ESI+) was used for the detection mechanism with the multiple reaction monitoring (MRM) mode. The method was validated over the concentration range of 150–1200 ng/mL for rat brain tissue. The precision and accuracy for all brain analyses were within the acceptable limit. The mean extraction recovery in rat brain was 83.6%. This validated method was successfully applied to a pharmacokinetic study in female Sprague Dawley rats, which were given a dose of 25 mg/kg TIG intraperitoneally at various time‐points. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

15.
Rhodiola rosea L. (Golden Root) has been used for a long time as an adaptogen in Chinese traditional medicine and is reported to have many pharmacological properties. A liquid chromatographic (LC) method with mass spectrometric (MS) detection based on selected ion monitoring (SIM) was developed for determining salidroside, sachaliside 1, rosin, 4-methoxycinnamyl-O-beta-glucopyranoside, rosarin, rosavin, cinnamyl-(6'-O-beta-xylopyranosyl)-O-beta-glucopyranoside, 4-methoxy-cinnamyl-(6'-O-alpha-arabinopyranosyl)-O-beta-glucopyranoside, rosiridin and benzyl-O-beta-glucopyranoside from the callus and plant extracts in one chromatographic run. Good linearity over the range 0.5-500 ng ml(-1) for salidroside, 2-2000 ng ml(-1) for rosavin and 2-500 ng ml(-1) for benzyl-O-beta-glucopyranoside was observed. The intra-assay accuracy and precision within quantitation ranges varied between -10.0 and +13.2% and between 0.7 and 9.0%, respectively. Optimization of the ionization process was performed with electrospray and atmospheric pressure chemical ionization techniques using four different additive compositions for eluents in the LC/MS scan mode, using both positive and negative ion modes. The best ionization sensitivity for the compounds studied was obtained with electrospray ionization when using pure water without any additives as the aqueous phase.  相似文献   

16.
A chemical characterization of major lipid components, namely, triacylglycerols, fatty acids and the unsaponifiable fraction, in a Quinoa seed lipids sample is reported. To tackle such a task, non‐aqueous reversed‐phase high‐performance liquid chromatography with mass spectrometry detection was employed. The latter was interfaced with atmospheric pressure chemical ionization for the analysis of triacylglycerols. The main triacylglycerols (>10%) were represented by OLP, OOL and OLL (P = palmitoyl, O = oleoyl, L = linoleoyl); the latter was present in the oil sample at the highest percentage (18.1%). Furthermore, fatty acid methyl esters were evaluated by gas chromatography with flame ionization detection. 89% of the total fatty acids was represented by unsaturated fatty acid methyl esters with the greatest percentage represented by linoleic and oleic acids accounting for approximately 48 and 28%, respectively. An extensive characterization of the unsaponifiable fraction of Quinoa seed lipids was performed for the first time, by using comprehensive two‐dimensional gas chromatography with dual mass spectrometry/flame ionization detection. Overall, 66 compounds of the unsaponifiable fraction were tentatively identified, many constituents of which (particularly sterols) were confirmed by using gas chromatography with high‐resolution time‐of‐flight mass spectrometry.  相似文献   

17.
A rapid and sensitive liquid chromatography/electrospray ionization tandem mass spectrometric (LC/ESI-MS/MS) method has been developed to determine 1, 2-[bis(1,2-benzisoselenazolone-3(2H)-ketone)]-ethane (BBSKE), a novel antineoplastic agent, in rat plasma. The analytes were separated on a C18 column with a mobile phase of methanol-water (75:25, v/v) and detected using a triple-quadrupole mass spectrometer in positive mode with the selective reaction monitoring. The characteristic ion dissociation transitions were m/z 603.0 --> 448.9 for derivatized BBSKE and m/z 631.0 --> 476.8 for derivatized internal standard. The assay was linear over a range of 1-1000 ng/mL with a lower limit of quantification of 1 ng/mL. Intra- and inter-day precisions were less than 9.6 and 5.0%, respectively, and the accuracy ranged from -5.2 to 4.0%. The validated method was successfully applied to the characterization of pharmacokinetic profile of BBSKE after oral administration in rats. Cop  相似文献   

18.
A simple, sensitive, and mild method for the determination of amino compounds based on a condensation reaction with 1-ethyl-3-(3-dimethylaminopropyl)-carbodiimide hydrochloride (EDC·HCl) as the dehydrant with fluorescence detection has been developed. Amines were derivatized to their acidamides with labeling reagent 2-(2-phenyl-1H-phenanthro-[9,10-d]imidazole-1-yl)-acetic acid (PPIA). Studies on derivatization conditions indicated that the coupling reaction proceeded rapidly and smoothly in the presence of a base catalyst in acetonitrile to give the corresponding sensitively fluorescent derivatives with an excitation maximum at λex 260 nm and an emission maximum at λem 380 nm. The labeled derivatives exhibited high stability and were enough to be efficiently analyzed by high-performance liquid chromatography. Identification of derivatives was carried out by online post-column mass spectrometry (LC/APCI-MS/MS) and showed an intense protonated molecular ion corresponding m/z [MH]+ under APCI in positive-ion mode. At the same time, the fluorescence properties of derivatives in various solvents or at different temperature were investigated. The method, in conjunction with a gradient elution, offered a baseline resolution of the common amine derivatives on a reversed-phase Eclipse XDB-C8 column. LC separation for the derivatized amines showed good reproducibility with acetonitrile-water as mobile phase. Detection limits calculated from 0.78 pmol injection, at a signal-to-noise ratio of 3, were 3.1-18.2 fmol. The mean intra- and inter-assay precision for all amine levels were <3.85% and 2.11%, respectively. Excellent linear responses were observed with coefficients of >0.9996. The established method for the determination of aliphatic amines from real wastewater and biological samples was satisfactory.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号