首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Gradient elution provides significantly higher peak capacity in comparison to the isocratic elution mode, hence it is very useful in online comprehensive two-dimensional liquid chromatography (LC). We compared suitability of five commercial core-shell columns and one monolithic column for fast gradients in the second LC dimension, where the time of separation is strictly limited by the fraction cycle time. In two-dimensional reversed-phase systems with partially correlated retention, the resolution, the peak capacity, and the regularity of coverage of the second-dimension retention space can be improved by appropriate adjusting the gradient time and the gradient range to suit the sample properties. We developed a new strategy for adjusting the gradient mobile phase composition range in the second-dimension, employing the retention data of representative sample standards characterizing the sample properties, which can be calibrated using the reference alkylbenzene series. Optimized second-dimension gradients with single-step or segmented profiles covering two or more fraction ranges, employed for the separation of subsequent fractions from the first-dimension, improve significantly the resolution, the separation time, and the regularity of coverage of the two-dimensional retention plane. The approach was applied to the two-dimensional comprehensive separation of phenolic acids and flavonoid compounds occurring as natural antioxidants.  相似文献   

2.
A 2-D separation platform was constructed using micro strong cation-exchange liquid chromatography (μ-SCXLC) and reversed-phase pressurized capillary electrochromatography (RP-pCEC) for the analysis of complex samples. Samples were fractionated by the first-dimension μ-SCXLC with a linear solvent gradient and then injected into the second-dimension RP-pCEC for further separation. The μ-SCXLC/RP-pCEC 2-D system with three separation mechanisms, namely strong cation-exchange, reversed-phase chromatography and electrophoresis, provided high selectivity, high resolution and high peak capacity compared to one-dimensional chromatographic approaches. Separation effectiveness of this 2-D system was demonstrated by the analysis of different kinds of complex samples, such as traditional Chinese medicine Cortex Phellodendri, bovine serum albumin (BSA) tryptic digest and real serum tryptic digest. A theoretical peak capacity of approximately 1200 was achieved, which proves its promising potential for the separation and analysis of complex samples.  相似文献   

3.
Z Liu  D Zhu  Y Qi  X Chen  Z Zhu  Y Chai 《Journal of separation science》2012,35(17):2210-2218
In the work presented here, a novel approach to comprehensive two-dimensional liquid chromatography is evaluated. Reversed-phase liquid chromatography was employed for the first-dimension separation and polyamine chromatography was chosen for the second-dimension separation mode. The two dimensions are highly orthogonal and the separation efficacy of the developed octadecylsilica × polyamine was tested by separating an extract from Anemarrhena asphodeloides. The steroid glycosides identified by comprehensive two-dimensional liquid chromatography in this experiment were compared to those obtained for monodimensional liquid chromatography. The comprehensive two-dimensional liquid chromatography system, thanks to the complementary separation selectivity and enhanced peak capacity provided by the two columns, allowed to distribute five compounds of low amounts otherwise unachievable by monodimensional liquid chromatography. In addition, four steroid isomers with similar fragmentation characteristics in MS/MS spectra, were newly separated based on their different chemical structures.  相似文献   

4.
In this work, devices for two-dimensional separations are considered. The device contains a flow distributor, a first-dimension channel, and 17 second-dimension outlets. In the design, all connections between the first-dimension channel, the flow distributor, and the second-dimension outlets were tapered, with a minimal diameter of 20 μm. The use of photo-masking is explored for the fabrication of monolithic frits in all tapered connections. Monolithic frits with optimized permeability and length were successfully fabricated in all 33 tapered channels through light-induced polymerization, photo-masking, and selective exposure. The efficacy of the monolithic frits was demonstrated by creating a packed bed of 15-μm particles, confined within the first-dimension channel. The outlet of the first-dimension channel was successfully connected to a mass spectrometer. Effective flow confinement was demonstrated with a reversed-phase separation of a mixture of five standard peptides.  相似文献   

5.
A multiplexed dual-secondary column comprehensive two-dimensional gas chromatography approach (GC × 2GC) designed for complex sample analysis is introduced. The approach splits the first-dimension column effluent into two second-dimension columns with different stationary phases, and recombines the two streams into one detector post-separation. The approach produces two single two-dimensional chromatograms for each injection. Careful manipulation of thermal modulator timing parameters combined with a novel contra-directional modulation regime facilitates this approach. A selection of 34 laboratory reference compounds containing n-alkanes, alcohols, aromatic hydrocarbons, ketones, esters and halogenated hydrocarbons were analysed to demonstrate the approach. The dual two-dimensional chromatogram from this single detector system provides complementary information due to the unique selectivity of the three separation columns. The results of this proof-of-principle investigation provide significant impetus for further development of GC × 2GC–MS methodology.  相似文献   

6.
This work compares the performance of the three different schemes implementing two-dimensional liquid chromatography (2D-LC) in terms of the peak capacity that they can generate and of the time that they need to complete a two-dimensional analysis. We discuss in detail how time is spent in these two-dimensional liquid chromatography×liquidchromatography×liquid chromatography (LC×LCLC×LC) schemes and how to compare them. Keeping constant the characteristics of the first-dimension separation, we systematically varied those of the second-dimension separation and of its coupling to the first-dimension. In the process, five systems were created, based on the principles of the three known implementations of comprehensive 2D-LC. This work demonstrates an original method for the selection of the best comprehensive 2D-LC approach, depending on the desired peak capacity and on time constraints. The decision to use a 2D-LC method arises from the need to achieve a given resolution (i.e., a target peak capacity) within as short a time as possible or to reach the highest possible resolution in a given analysis time. Using the most appropriate schemes, we suggest how it is realistically possible to generate peak capacities ranging from 266 in just over 20 min or about 2800 in 2.3 h. When the time available for a two-dimensional separation is very short and the desired peak capacity cannot be achieved in 1D-LC, an on-line 2D-LC approach is unquestionably best. However, if a longer analysis time is acceptable, a 10-fold increase in the peak capacity can be obtained at the cost of a mere 7-fold increase in total analysis time.  相似文献   

7.
Comprehensive two-dimensional liquid chromatography (LC x LC) is a powerful tool for the separation of complex biological samples. This technique offers the advantage of simplified automation and greater reproducibility in a shorter analysis time than off-line two-dimensional separation systems. In the present study, an LC x LC system is developed enabling simultaneous UV and MS detection, and which can be easily converted to a conventional reversed-phase LC-UV/MS system. In LC x LC, a 60-min reversed-phase LC separation with a linear solvent gradient in the first dimension is coupled to a second-dimension separation on a mixed-mode cation-exchange/reversed-phase column with a modulation time of 60s. The isocratic separation in the second-dimension column is optimized by the use of a multi-step gradient where the organic and the ionic modifier are varied independently. Intraday (n=3) and interday (n=4) variability of the retention times were evaluated with the complete system and found to be 0.5% and 0.7%, respectively. Good linearity was observed in calibration curves for three different compounds varying in polarity.  相似文献   

8.
To obtain the best compromise between peak capacity and analysis time in one-dimensional and two-dimensional (2D) liquid chromatography (LC), column technology and operating conditions were optimized. The effects of gradient time, flow rate, column temperature, and column length were investigated in one-dimensional reversed-phase (RP) gradient nano-LC, with the aim of maximizing the peak per unit time for peptide separations. An off-line two-dimensional LC approach was developed using a micro-fractionation option of the autosampler, which allowed automatic fractionation of peptides after a first-dimension ion-exchange separation and re-injection of the fractions onto a second-dimension RP nano-LC column. Under the applied conditions, which included a preconcentration/desalting time of 5 min, and a column equilibration time of 12.5 min, the highest peak capacity per unit time in the 2D-LC mode was obtained when applying a short (10 min) first-dimension gradient and second-dimension RP gradients of 20 min duration. For separations requiring a maximum peak capacity of 375, one-dimensional LC was found to be superior to the off-line strong cation-exchange/×/RPLC approach in terms of analysis time. Although a peak capacity of 450 could be obtained in one-dimensional LC when applying 120-min gradients on 500-mm long columns packed with 3-μm particles, for separations requiring a peak capacity higher than 375 2D-LC experiments provide a higher peak capacity per unit time. Finally, the potential of off-line 2D-LC coupled to tandem mass spectrometry detection is demonstrated with the analysis of a tryptic digest of a mixture of nine proteins and an Escherichia coli digest.  相似文献   

9.
Comprehensive two-dimensional liquid chromatography (LC x LC) connected on-line to electrospray ionisation time-of-flight mass spectrometry (ESI-TOF-MS) was employed for analysis of aqueous extract of Stevia rebaudiana. Different combinations of strong cation-exchange (SCX), amino (NH2), and octadecyl siloxane (C18) stationary phases were tested in the separation of all nine known sweet Stevia glycosides. A combination of C18 as the first-dimension column and NH2 as the second-dimension column fully separated all the glycosides from the matrix. The method proved to be quantitative and repeatable. The limit of detection (S/N=3) for stevioside, a widely used natural sweetener, was 43.4 ng/g in dry leaves. The RSD for retention times was <0.1% and that of peak areas 4.5%.  相似文献   

10.
A comprehensive two-dimensional liquid chromatography system in combination with photodiode array and mass spectrometry detection was developed for analysis of polyphenols in sugarcane (Saccharum spp.) leaf extracts. To achieve this, a micro cyano column and a partially porous octodecylsilica column were used in the first and the second dimension, respectively. The choice of the cyano column over other reversed-phase columns tested for the first-dimension separation was due to its lower correlation selectivity with respect to the octodecylsilica column, which was used for the second-dimension separation. Even when reversed-phase mode was used in both dimensions, a satisfactory degree of orthogonality was achieved by use of different gradient elution modes in the second dimension. By means of the setup investigated, 38 polyphenolic compounds were detected, and among them 24 were positively identified by means of complementary data from photodiode array and mass spectrometry detection and an in-house database. This is the first time such a powerful analytical technique has been used for polyphenolic characterization of sugarcane extracts.
Figure
RP-LC×RP-LC contour plot of a sugarcane leaf extract  相似文献   

11.
Chen X  Fazal MA  Dovichi NJ 《Talanta》2007,71(5):1981-1985
Two-dimensional capillary electrophoresis was used for the separation of proteins and biogenic amines from the mouse AtT-20 cell line. The first-dimension capillary contained a TRIS–CHES–SDS–dextran buffer to perform capillary sieving electrophoresis, which is based on molecular weight of proteins. The second-dimension capillary contained a TRIS–CHES–SDS buffer for micellar electrokinetic capillary chromatography. After a 61-s preliminary separation, fractions from the first-dimension capillary were successively transferred to the second-dimension capillary, where they further separated by MECC. The two-dimensional separation required 60 min.  相似文献   

12.
Many samples contain compounds with various numbers of two or more regular structural groups. Such "multidimensional" samples (according to the Giddings' notation) are best separated in orthogonal chromatographic systems with different selectivities for the individual repeat structural groups, described by separation factors. Correlations between the repeat group selectivities characterize the degree of orthogonality and suitability of chromatographic systems for two-dimensional (2D) separations of two-dimensional samples. The range of the structural units in that can be resolved in a given time can be predicted on the basis of a model describing the repeat group selectivity in the first- and second-dimension systems. Two-dimensional liquid chromatographic system combining reversed-phase (RP) mode in the first dimension and normal-phase (NP) mode in the second dimension were studied with respect to the possibilities of in-line fraction transfer between the two modes. Hydrophilic interaction liquid chromatography (HILIC) with an aminopropyl silica column (APS) is more resistant than classical non-aqueous NP systems against adsorbent desactivation with aqueous solvents transferred in the fractions from the first, RP dimension to the second dimension. Hence, HILIC is useful as a second-dimension separation system for comprehensive RP-NP LCxLC. A comprehensive 2D RP-NP HPLC method was developed for comprehensive 2D separation of ethylene oxide-propylene oxide (EO-PO) (co)oligomers. The first-dimension RP system employed a 120 min gradient of acetonitrile in water on a C18 microbore column at the flow-rate of 10 microL/min. In the second dimension, isocratic HILIC NP with ethanol-dichloromethane-water mobile phase on an aminopropyl silica column at 0.5 mL/min was used. Ten microliter fractions were transferred from the RP to the HILIC NP system at 1 min switching valve cycle frequency.  相似文献   

13.
14.
Summary An optimization strategy for the separation of a small number of peptides from a complex biological sample by two-dimensional liquid chromatography is presented. Ion-exchange chromatography is followed by reversed-phase separation. The ion-exchange separation is performed with a step gradient which admits a high sample load and simplifies instrumentation. The reversed-phase separation complements the first dimension with a different retention mechanism and higher resolution by linear gradient elution.Chromatographic theory is combined with experimental design to find separation conditions, for both dimensions, that allow the fastest gradient in the second dimension, giving short separation time, low detection limits and high load capacity. This is illustrated by the separation of a peptide from rat brain tissue, with a simple off-line arrangement. The strategy presented is useful in both analytical and preparative applications, and is widely applicable as it does not rely on special instrumentation or extensive knowledge of the sample.Dedicated to Professor Leslie S. Ettre on the occasion of his 70th birthday.  相似文献   

15.
In comprehensive two-dimensional gas chromatography (GC x GC), samples experience two-dimensional separation implemented by a modulator which helps preserve the first-dimension separation and facilitates the second-dimension separation by periodically collecting, focusing and launching the material from the primary column onto the secondary column with a different stationary phase. Column overloading in GC x GC is a considerable problem, aggravated by the fact that two columns are involved. Broad first-dimension peaks of an analyte help produce smaller fractions of the analyte in the second-dimension, reducing the chance of secondary column overloading. One of the means to generate broad peaks in the first-dimension is to use thick film primary columns. A series of primary columns of various film thickness were tested in the study, and the results indicate that when other conditions are kept constant, 1 microm film columns often provide better resolution in both first and second-dimension but at the expense of a much longer separation time; 0.1 microm is clearly inadequate for GC x GC separation; 0.5 and 0.25 microm film columns seem to be the best compromises.  相似文献   

16.
In recent years, two-dimensional liquid chromatography (2D-LC) has been used increasingly for the analysis of synthetic polymers. A 2D-LC analysis provides richer information than a single chromatography analysis at the cost of longer analysis time. The time required for a comprehensive 2D-LC analysis is essentially proportional to the analysis time of the second dimension separation. Many of 2D-LC analyses of synthetic polymers have employed size exclusion chromatography (SEC) for the second-dimension analysis due to the relatively short analysis time in addition to the wide use in the polymer analysis. Nonetheless, short SEC columns are often used for 2D-LC analyses to reduce the separation time, which inevitably deteriorates the resolution. In this study, we demonstrated that high temperature SEC can be employed as an efficient second-LC in the 2D-LC separation of synthetic polymers. By virtue of high temperature operation (low solvent viscosity and high diffusivity of the polymer molecules), a normal length SEC column can be used at high flow rate with little loss in resolution.  相似文献   

17.
Comprehensive two-dimensional gas chromatography (GC×GC) has been applied to the quantitative analysis of benzene, toluene, ethylbenzene, xylenes (BTEX), and all heavier aromatic compounds in gasoline. The two-dimensional chromatographic separation used volatility selection on the first-dimension column and polarity selection on the second-dimension column. In the resulting GC×GC chromatogram, aromatic species were resolved from other compound classes. Moreover, structurally related aromatics were grouped in a manner that facilitated identification and integration. The response of a flame ionization detector to each major aromatic group in gasoline was calibrated using internal standards. Quantitation produced results directly comparable with ASTM standard methods. The present GC×GC method can be expanded to analyze other gasoline components.  相似文献   

18.
A comprehensive orthogonal two-dimensional liquid chromatography (2D-LC) based on the modification of mobile phases was developed with a sample loop–valve interface. To improve the compatibility of mobile phases and analysis speed, some special solvents were chosen as the mobile phases, and the column temperature was elevated to decrease the viscosity of mobile phases of reversed-phase liquid chromatography (RPLC). Based on this principle, the first dimension was normal-phase liquid chromatography (NPLC) with a SiO2 column, and the second dimension was reversed-phase liquid chromatography containing two tandem C18 columns. 1,4-Dioxane was used in the NPLC mobile phase, and isopropyl alcohol was employed in the RPLC mobile phase. Moreover, the elevated column temperature enabled the reduction of the backpressure and using tandem C18 columns to improve the resolving power in RPLC. The new comprehensive 2D-LC system and applied strategy offered a novel idea for construction of 2D-LC system. A traditional Chinese medicine, Zhengtian pill, was used as the test sample to evaluate the constructed 2D-LC system. 876 peaks were detected, and the peak capacity reached 1740.  相似文献   

19.
The proteomic analysis of plasma and serum samples represents a formidable challenge due to the presence of a few highly abundant proteins such as albumin and immunoglobulins. Detection of low abundance protein biomarkers therefore requires either the specific depletion of high abundance proteins using immunoaffinity columns and/or optimized protein fractionation methods based on charge, size or hydrophobicity. Here we describe a two-dimensional (2D) liquid chromatography separation method for the fractionation of rat plasma. In the first dimension proteins were separated by chromatofocusing according to their isoelectric point (pI). In the second dimension, proteins were further fractionated by non-porous, reversed-phase chromatography according to their hydrophobicity. The data from both separations was displayed as a 2D protein expression map of pI versus retention time (relative hydrophobicity). Both separations were carried out on the ProteomeLab PF 2D system (Beckman Coulter), an instrument platform that provides a high degree of automation and real-time monitoring of the separation process. The reproducibility of the first-dimension separation was evaluated in terms of pH gradient formation. The second-dimension separation was evaluated in terms of peak retention times on the reversed-phase column. We found in four consecutive chromatofocusing separations that the pH gradient differed by less than 0.2 pH units at any time during the elution step. Second dimension retention times of peaks from identical pI fractions differed by less than 7 s in six consecutive separations. Each 2D separation generated a total of 540 fractions which were analyzed by matrix assisted laser desorption ionization time of flight mass spectrometry (MALDI-TOF MS). We detected approximately 275 peptides and proteins with molecular masses ranging from 3 to 225 kDa. Most fractions were found to contain multiple low and high molecular weight proteins. Differential display of 2D protein expression maps from retinol-sufficient and -deficient rat plasma samples identified a fraction with several proteins that appeared to be down-regulated in the vitamin A-deficient animal. Quantitative proteomic analysis of complex samples such as plasma is still a difficult task. We discuss the potential of this approach for biomarker discovery and address the experimental challenges that remain.  相似文献   

20.
The theoretical advantages and drawbacks of using a multiple-, parallel column approach in on-line multidimensional liquid chromatography systems were investigated. Much time or peak capacity can be gained with the use of multiple parallel columns at the second-dimension while the aggregate time of separation increases only by the increment of the gradient time of the second-dimension. Multidimensional chromatographic systems are now used to perform many tasks ranging from routine, fast analyses to specialized, arduous separations. In this work, we focus on the advantages of a multiple, parallel columns approach to on-line multidimensional liquid chromatography systems. Calculations of the achievable peak capacities were made as functions of the number of columns operated in parallel. Increasing the number of second-dimension columns from one to two or three causes the largest increase in peak capacity with only a slight increase of aggregate time. We also present some practical aspects to consider when attempting multidimensional separations with multiple columns operated in parallel.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号