首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The present research is based on the full exploitation of the separation power of a 0.05 mm internal diameter (ID) capillary, as a comprehensive two-dimensional (2D) GC (GC × GC) secondary column, with the objective of attaining very high-resolution second dimension separations. The aim was achieved by using a split-flow system developed in previous research [P.Q. Tranchida, A. Casilli, P. Dugo, G. Dugo, L. Mondello, Anal. Chem. 79 (2007) 2266], and a dual-oven GC × GC instrument. The column combination employed consisted of a polar 30 m × 0.25 mm ID column connected, by means of a T union, to a detector-linked high-resolution 1.1 m × 0.05 mm ID apolar analytical column and to a 0.33 m × 0.05 mm ID retention gap; the latter was connected to a manually operated split valve. As previously demonstrated, the use of a split valve enables the regulation of gas flows through both analytical columns, generating the most appropriate gas linear velocities. Comprehensive 2D GC experiments were carried out on Arabica roasted coffee volatiles (previously extracted by means of solid-phase microextraction) with the split-valve closed (equal to what can be defined as conventional GC × GC) and with the split-valve opened at various degrees. The reasons why it is absolutely not effective to use a 0.05 mm ID column as second dimension in a conventional GC × GC instrument will be discussed and demonstrated. On the contrary, the use of a 0.05 mm ID column as second dimension, under ideal conditions in a split-flow, twin-oven system, will also be illustrated and discussed.  相似文献   

2.
This paper reports the conditions of online hyphenation of supercritical fluid chromatography (SFC) with twin comprehensive two-dimensional gas chromatography (twin-GC × GC) for detailed characterization of middle distillates; this is essential for a better understanding of reactions involved in refining processes. In this configuration, saturated and unsaturated compounds that have been fractionated by SFC are transferred on two different GC × GC columns sets (twin-GC × GC) placed in the same GC oven. Cryogenic focusing is used for transfer of fractions into the first dimension columns before simultaneous GC × GC analysis of both saturated and unsaturated fractions. The benefits of SFC–twin-GC × GC are demonstrated for the extended alkane, iso-alkane, alkene, naphthenes and aromatics analysis (so-called PIONA analysis) of diesel samples which can be achieved in one single injection. For that purpose, saturated and unsaturated compounds have been separated by SFC using a silver loaded silica column prior to GC × GC analysis. Alkenes and naphthenes are quantitatively recovered in the unsaturated and saturated fractions, respectively, allowing their identification in various diesel samples. Thus, resolution between each class of compounds is significantly improved compared to a single GC × GC run, and for the first time, an extended PIONA analysis of diesel samples is presented.  相似文献   

3.
Comprehensive two-dimensional gas chromatography (GC × GC) time-of-flight mass spectrometry (ToFMS) was applied to the analysis of urinary organic acids from patients with inborn errors of metabolism. Abnormal profiles were obtained from all five patients studied. Methylmalonic academia and deficiencies of 3-methylcrotonyl-CoA carboxylase and medium chain acyl-CoA dehydrogenase gave diagnostic profiles while deficiencies of very long chain acyl-CoA dehydrogenase and mitochondrial 3-hydroxy-3-methylglutaryl CoA synthase gave profiles with significant increases in dicarboxylic acids suggestive of these disorders. The superior resolving power of GC × GC with ToFMS detection was useful in separating isomeric organic acids that were not resolved using one-dimensional GC. A novel urinary metabolite, crotonyl glycine, was also discovered in the mitochondrial 3-hydroxy-3-methylglutaryl CoA synthase sample which may be a useful specific diagnostic marker for this disorder. The quantitative aspects of GC × GC were investigated using stable isotope dilution analyses of glutaric, glyceric, orotic, 4-hydroxybutyric acids and 3-methylcrotonylglycine. Correlation coefficients for linear calibrations of the analytes ranged from 0.9805 to 0.9993 (R2) and analytical recoveries from 77% to 99%. This study illustrates the potential of GC × GC–ToFMS for the diagnosis of organic acidurias and detailed analysis of the complex profiles that are often associated with these disorders.  相似文献   

4.
In this work, a methodology to characterise the volatile and semi-volatile compounds from marine salt by headspace solid-phase microextraction (HS-SPME) and comprehensive two-dimensional gas chromatography time-of-flight mass spectrometry (GC × GC/TOFMS) was developed. Samples from two saltpans of Aveiro, in Portugal, with diverse locations, obtained over three years (2004, 2005, and 2007) were analysed. A 50/30 μm divinylbenzene/carboxen/polydimethylsiloxane SPME fibre was used. The volatiles present in the headspace of the solid salt samples (crystals) were equilibrated overnight at 60 °C and extracted for 60 min prior to injection in the GC × GC/TOFMS. 157 compounds, distributed over the chemical groups of hydrocarbons, aldehydes, esters, furans, haloalkanes, ketones, ethers, alcohols, terpenoids, C13 norisoprenoids, and lactones were detected across the samples. Furans, haloalkanes and ethers were identified for the first time in marine salt. The large number of co-elutions on the first column that were resolved by the GC × GC system revealed the complexity of marine salt volatile composition. The existence of a structured 2D chromatographic behaviour according to volatility, in the first dimension (1D), and primarily polarity, in the second dimension (2D), was demonstrated, allowing more reliable identifications. The resolution and sensitivity of GC × GC/TOFMS enabled the separation and identification of a higher number of volatile compounds compared to GC–qMS, allowing a deeper characterisation of this natural product.  相似文献   

5.
With the analysis of Chinese liquor Moutai as an example, the effect of different column combinations was studied on two-dimensional separation in comprehensive two-dimensional gas chromatography (GC × GC). A method to optimize column combinations was developed for achieving maximum orthogonality. Using a geometric approach to factor analysis, the degree of separation orthogonality was quantitatively estimated. The parameters evaluated include peak spreading angle, retention correlation, and practical peak capacity. When using the “reversed-type” column combinations (a polar column as the first dimension and a non- or less polar one as the second dimension), correlation coefficient was lower than or equal to 0.221, the spreading angle was higher than or equal to 77°, and more than 92% of the theoretical peak capacity was reasonably used. For Moutai liquor mainly consisting of some polar compounds, the HP-Innowax + DB1701 column combination was optimal. In addition, through the test of Grob mixture and McReynolds constant, the mechanism of solute-stationary phase interactions was disclosed in details, which validated the estimation of GC × GC orthogonality in a molecular level.  相似文献   

6.
A sample of tobacco essential oil was analyzed using gas chromatography-mass spectrometry (GC/MS) and comprehensive two-dimensional gas chromatography coupled to a time-of-flight mass spectrometry (GC × GC/TOFMS), respectively. In the GC/MS analysis, serially coupled columns were used. By comparing the GC/MS results with GC × GC/TOFMS results, many more components in the essential oil could be found within the two-dimensional separation space of GC × GC. The quantitative determination of components in the essential oil was performed by GC × GC with flame ionization detection (FID), using a method of multiple internal standards calibration.  相似文献   

7.
In this study, a new system for analysis using a dual comprehensive two-dimensional gas chromatography/targeted multidimensional gas chromatography (switchable GC × GC/targeted MDGC) analysis was developed. The configuration of this system not only permits the independent operation of GC, GC × GC and targeted MDGC analyses in separate analyses, but also allows the mode to be switched from GC × GC to targeted MDGC any number of times through a single analysis. By incorporating a Deans switch microfluidics transfer module prior to a cryotrapping device, the flow stream from the first dimension column can be directed to either one of two second dimension columns in a classical heart-cutting operation. Both second columns pass through the cryotrap to allow solute bands to be focused and then rapidly remobilized to the respective second columns. A short second column enables GC × GC operation, whilst a longer column is used for targeted MDGC. Validation of the system was performed using a standard mixture of compounds relevant to essential oil analysis, and then using compounds present at different abundances in lavender essential oil. Reproducibility of retention times and peak area responses demonstrated that there was negligible variation in the system over the course of multiple heart-cuts, and proved the reliable operation of the system. An application of the system to lavender oil, as a more complex sample, was carried out to affirm system feasibility, and demonstrate the ability of the system to target multiple components in the oil. The system was proposed to be useful for study of aroma-impact compounds where GC × GC can be incorporated with MDGC to permit precise identification of aroma-active compounds, where heart-cut multidimensional GC-olfactometry detection (MDGC-O) is a more appropriate technology for odour assessment.  相似文献   

8.
The separation characteristics of alkylchloroformate-derivatised amino acids (AAs) by using comprehensive two-dimensional gas chromatography (GC×GC) is reported. The use of a low-polarity/polar column set did not provide as good a separation performance as that achieved with a polar/non-polar column set, where the latter appeared to provide less correlation over the separation space. The degree of component correlation in each column set was estimated by using the correlation coefficient (r2; for 1tR and 2tR data) with the low-polarity/polar and polar/low-polarity sets returning correlation coefficients of 0.86, and 0.00 respectively, under the respective conditions employed for the experiments. The 1.5-m non-polar 2D column (0.1-mm ID; 0.1-m film thickness) gave peak halfwidths of the order of 50–80 ms. Linearity of detection was good, over a three order of magnitude concentration range, with typical lower detection limit of ca. 0.01 mg L–1, compared with 0.5 mg L–1 for normal GC operation with splitless injection. The method was demonstrated for analysis of AAs in a range of food and beverage products, including wine, beer and honey. The major AA in these samples was proline. The Heineken beer sample had a relatively more complex and more abundant AA content compared with the other beer sample. The wine and honey samples also gave a range of AA compounds. Repetition of the sample preparation/analysis procedure for the honey sample gave acceptable reproducibility for individual AAs.  相似文献   

9.
The application of comprehensive two-dimensional gas chromatography coupled to time-of-flight mass spectrometry (GC × GC-TOFMS) for the analysis of six anabolic agents (AAs) in doping control is investigated in this work. A non-polar–polar column configuration with 0.2 μm film thickness (df) second dimension (2D) column was employed, offering much better spread of the components on 2D when compared to the alternative 0.1 μm df2D column. The proposed method was tested on the “key” AA that the World Anti-Doping Agency (WADA) had listed at the low ng mL−1 levels (clenbuterol, 19-norandrosterone, epimethendiol, 17α-methyl-5α-androstane-3α,17β-diol, 17α-methyl-5β-androstane-3α,17β-diol and 3′-OH-stanozolol). The compounds were spiked in a blank urine extract obtained by solid-phase extraction, hydrolysis and liquid–liquid extraction; prior to analysis they were converted to the corresponding trimethylsilyl (TMS) derivatives. The limit of detection (LOD) was below or equal to the minimum required performance limit (MRPL) of 2 ng mL−1 defined by WADA, and the correlation coefficient was in the range from 0.995 to 0.999. The method allows choosing an ion from the full mass spectra which shows the least interference from the matrix and/or the best sensitivity; this can only be done if full scan mass spectral data are available. The advantage of GC × GC over classical one-dimensional GC (1D GC), in terms of separation efficiency and sensitivity, is demonstrated on a positive urine control sample at a concentration of 5 ng mL−1. The obtained similarity to the in-house created TOFMS spectra library at this level of concentration was in the range from 822 to 932 (on the scale from 0 to 999). Since full mass spectral information are recorded, the method allows the retro-search of non-target compounds or new “designer steroids”, which cannot be detected with established GC–MS methods that use selected ion monitoring (SIM) mode.  相似文献   

10.
Multi-dimensional chromatographic techniques, such as (comprehensive) two-dimensional liquid chromatography and (comprehensive) two-dimensional gas chromatography, are increasingly popular for the analysis of complex samples, such as protein digests or mineral oils. The reason behind the popularity of these techniques is the superior performance, in terms of peak-production rate (peak capacity per unit time), that multi-dimensional separations offer compared to their one-dimensional counterparts. However, to fully utilize the potential of multi-dimensional chromatography it is essential that the separation mechanisms used in each dimension be independent of each other. In other words, the two separation mechanisms need to be orthogonal. A number of algorithms have been proposed in the literature for measuring chromatographic orthogonality. However, these methods have their limitations, such as reliance on the division of the separation space into bins, need for specialist software or requirement of advanced programming skills. In addition, some of the existing methods for measuring orthogonality include regions of the separation space that do not feature peaks. In this paper we introduce a number of equations which provides information on the spread of the peaks within the separation space in addition to measuring orthogonality, without the need for complex computations or division of the separation space into bins.  相似文献   

11.
The present investigation is focused on a simple flow modulator (FM), for comprehensive two-dimensional gas chromatography (GC×GC). The interface is stable at high temperatures, and consists of a metallic disc (located inside the GC oven) with seven ports, which are connected to an auxiliary pressure source via two branches, to the first and second dimension, to a waste branch (linked to a needle valve) and to an exchangeable modulation loop (2 ports). The ports are connected via micro-channels, etched on one of the inner surfaces of the disc. Modulation is achieved using a two-way electrovalve, connected on one side to the additional pressure source, and to the two metal branches, on the other. An FM enantio-GC×polar-GC method (using a flame ionization detector) was optimized (a 40-μL loop was employed), for the analysis of essential oils. As an example, an application on spearmint oil is shown; the method herein proposed was subjected to validation. Finally, an FM GC×GC diesel experiment was carried out, using an apolar-polar column combination, to demonstrate the effectiveness of the modulator in the analysis of a totally different sample-type.  相似文献   

12.
Two-dimensional gas chromatography (GC × GC) coupled with time-of-flight mass spectrometric (TOFMS) method was optimized for simultaneous analysis of 160 pesticides, 12 dioxin-like polychlorinated biphenyls (PCBs), 12 polyaromatic hydrocarbons (PAHs) and bisphenol A in grape and wine. GC × GC–TOFMS could separate all the 185 analytes within 38 min with >85% NIST library-based mass spectral confirmations. The matrix effect quantified as the ratio of the slope of matrix-matched to solvent calibrations was within 0.5–1.5 for most analytes. LOQ of most of the analytes was ≤10 μg/L with nine exceptions having LOQs of 12.5–25 μg/L. Recoveries ranged between 70 and 120% with <20% expanded uncertainties for 151 and 148 compounds in grape and wine, respectively, with intra-laboratory Horwitz ratio <0.2 for all analytes. The method was evaluated in the incurred grape samples where residues of cypermethrin, permethrin, chlorpyriphos, metalaxyl and etophenprox were detected at below MRL.  相似文献   

13.
In a tense energetic context, the characterization of heavy petroleum fractions becomes essential. Conventional comprehensive two-dimensional gas chromatography (2D-GC or GC × GC) is widely used for middle distillates analysis, but only a few applications are devoted to these heavier fractions. In this paper, it is shown how the optimization of GC × GC separation allowed the determination of suitable high-temperature (HT) conditions, adjusting column properties and operating conditions. 2D separations were evaluated using 2D separation criteria and a new concept of 2D asymmetry (As2D). New HT conditions allowed the extension of GC × GC range of applications to heavier hydrocarbons, up to nC60. A first application of high-temperature two-dimensional gas chromatography (HT-2D-GC) to a full vacuum gas oil (VGO) feed stock is described. Comparisons with other standardized methods illustrate the high potential of HT-2D-GC for heavy fractions analysis.  相似文献   

14.
Comprehensive two-dimensional gas chromatography coupled with time-of-flight mass spectrometry (GC × GC–TOFMS) is a well-established instrumental platform for complex samples. However, chemometric data analysis is often required to fully extract useful information from the data. We demonstrate that retention time shifting from one modulation to the next, Δ2tR, is not sufficient alone to quantitatively describe the trilinearity of a single GC × GC–TOFMS run for the purpose of predicting the performance of the chemometric method parallel factor analysis (PARAFAC). We hypothesize that analyte peak width on second dimension separations, 2Wb, also impacts trilinearity, along with Δ2tR. The term trilinearity deviation ratio, TDR, which is Δ2tR normalized by 2Wb, is introduced as a quantitative metric to assess accuracy for PARAFAC of a GC × GC–TOFMS data cube. We explore how modulation ratio, MR, modulation period, PM, temperature programming rate, Tramp, sampling phase (in-phase and out-of-phase), and signal-to-noise ratio, S/N, all play a role in PARAFAC performance in the context of TDR. Use of a PM in the 1–2 s range provides an optimized peak capacity for the first dimension separation (500–600) for a 30 min run, with an adequate peak capacity for the second dimension separation (12–15), concurrent with an optimized two-dimensional peak capacity (6000–7500), combined with sufficiently low TDR values (0–0.05) to facilitate low quantitative errors with PARAFAC (0–0.5%). In contrast, use of a PM in the 5 s or greater range provides a higher peak capacity on the second dimension (30–35), concurrent with a lower peak capacity on the first dimension (100–150) for a 30 min run, and a slightly reduced two-dimensional peak capacity (3000–4500), and furthermore, the data are not sufficiently trilinear for the more retained second dimension peaks in order to directly use PARAFAC with confidence.  相似文献   

15.
The present work is focused on the development/optimization of a comprehensive two-dimensional gas chromatography method, with dual detection [flame ionization (FID) and mass spectrometric], for the simultaneous identification and quantification of mineral-oil contaminants in a variety of food products. The two main classes of contaminants, namely saturated and aromatic hydrocarbons, were previously fractionated on a manually-packed silver silica solid-phase extraction (SPE) cartridge. The quantitative results were compared with those obtained by performing a large volume injection, in a GC-FID system, after the same SPE process and by an on-line liquid–gas chromatography method, with very similar results observed. The presence of a series of unknown compounds, that appeared when using the off-line methods, was investigated using the mass spectrometric data, and were tentatively-identified as esterified fatty acids, most probably derived from vegetable oil based ink.  相似文献   

16.
A method was developed to calculate the second dimension retention index of comprehensive two-dimensional gas chromatography time-of-flight mass spectrometry (GC×GC/TOF-MS) data using n-alkanes as reference compounds. The retention times of the C(7)-C(31) alkanes acquired during 24 isothermal experiments cover the 0-6s retention time area in the second dimension retention time space, which makes it possible to calculate the retention indices of target compounds from the corresponding retention time values without the extension of the retention space of the reference compounds. An empirical function was proposed to show the relationship among the second dimension retention time, the temperature of the second dimension column, and the carbon number of the n-alkanes. The proposed function is able to extend the second dimension retention time beyond the reference n-alkanes by increasing the carbon number. The extension of carbon numbers in reference n-alkanes up to two more carbon atoms introduces <10 retention index units (iu) of deviation. The effectiveness of using the proposed method was demonstrated by analyzing a mixture of compound standards in temperature programmed experiments using 6 different initial column temperatures. The standard deviation of the calculated retention index values of the compound standards fluctuated from 1 to 12 iu with a mean standard deviation of 5 iu.  相似文献   

17.
Considering the global energetic context, diversifying fuels is of growing importance and many new alternatives are promising. Coal liquefaction products definitely appear among the new generation substitutes. These product's characteristics are very far from fuel specifications as they are mainly composed of naphthenes, aromatics, polycondensed naphthenic and aromatic structures and heteroatomic compounds (nitrogen and oxygen), with a very low paraffin content. Identification and quantification of oxygen-containing species in coal-derived liquids are of considerable importance to understand their behaviors in further processing. However, these species have not been characterized as fully as the predominant hydrocarbon components. Literature shows that these compounds consist mainly in alkylated phenolic and furanic structures. Therefore, comprehensive two-dimensional gas chromatography has been investigated to provide enhanced molecular characterization of these complex samples. Several different configurations involving innovative column configurations were tested. Each of them was optimized by testing different column lengths, modulation periods, and oven conditions. A comparison of the contribution of each column configuration was carried out regarding four main criteria: individual separation of oxygenates, group type separation, resolution, and space occupation. One of them enabled an outstanding separation of paraffins, naphthenes, monoaromatics, diaromatics and targeted O-compounds in a direct coal liquefaction product. It was therefore subjected to further experimentations using a time-of-flight mass spectrometer to validate the identification and unravel more than fifty oxygenated molecular structures. A group-type quantification was also established for four column arrangements and gives the distribution of paraffins, naphthenes and aromatics. It can be concluded from this study that a non-orthogonal arrangement involving a highly polar column in the first dimension was the most adapted one.  相似文献   

18.
A number of chiral oxime compounds have been synthesised and their gas chromatographic analysis on both a polyethelene glycol phase column and two chiral column phases was investigated. Of particular interest to this work is the observation of dynamic interconversion behaviour, both in a single dimensional analysis, and by using comprehensive two-dimensional gas chromatography (GC × GC). A number of non-chiral compounds were studied as a means to understand the nature of the behaviour observed. As expected, the achiral compound on both the wax column and the chiral column generated two isomeric compounds—the E and Z isomers. On the wax column, a characteristic interconversion zone representing the dynamic process was observed, with extent of interconversion dependent on the conditions used. For the chiral compounds, two isomers and the interconversion zone were exhibited on the wax column, however on the chiral column 4 isomeric peaks were found—the (R) and (S) enantiomers of each of the E and Z isomers. In the case of the chiral column, the extent of interconversion was negligible, and this appears to correlate with the use of low polarity columns. In order to encourage dynamic interconversion, a polyethylene glycol column was coupled to the chiral column, by placing it either before or after the chiral column. In this case a monitor detector was employed between the two columns in order to isolate the effects of the first column from the behaviour on the second. In a further study, the most appropriate column arrangement from the earlier study was placed into a comprehensive two-dimensional gas chromatography instrument, with a wax-phase column in the second dimension. The unique location of peaks for each of the molecules in 2D space and patterns for the interconversion processes is interpreted phenomenologically.  相似文献   

19.
An image processing approach originating from the proteomics field has been transferred successfully to the processing of data obtained with comprehensive two-dimensional gas chromatographic separations data. The approach described here has proven to be a useful analytical tool for unbiased pattern comparison or profiling analyses, as demonstrated with the differentiation of volatile patterns (“aroma”) from fruits such as apples, pears, and quince fruit. These volatile patterns were generated by headspace solid phase microextraction coupled to comprehensive two-dimensional gas chromatography (HS-SPME-GC × GC). The data obtained from GC × GC chromatograms were used as contour plots which were then converted to gray-scale images and analyzed utilizing a workflow derived from 2D gel-based proteomics. Run-to-run variations between GC × GC chromatograms, respectively their contour plots, have been compensated by image warping. The GC × GC images were then merged into a fusion image yielding a defined and project-wide spot (peak) consensus pattern. Within detected spot boundaries of this consensus pattern, relative quantities of the volatiles from each GC × GC image have been calculated, resulting in more than 700 gap free volatile profiles over all samples. These profiles have been used for multivariate statistical analysis and allowed clustering of comparable sample origins and prediction of unknown samples. At present state of development, the advantage of using mass spectrometric detection can only be realized by data processing off-line from the identified software packages. However, such information provides a substantial basis for identification of statistically relevant compounds or for a targeted analysis.  相似文献   

20.
A detailed mass map of C10's is required to better understand the mechanism of decalin catalytic ring opening/rearrangement. Conventional GC-FID or GC-MSD techniques could not accurately identify these isomers. Comprehensive two-dimensional gas-chromatography with MSD (GC × GC-MSD) proved to be a powerful tool for this purpose, due to its enhanced peak resolution. Analytical response quality was evaluated by the separation of two contiguous peaks and MS profile “clearness”. This allowed fragmentation study for nearly pure species. Tentative attributions, based on fragmentation-rearrangement in the MSD environment, were made after confirming that MS data bases routinely mistake olefins for cyclo-alkanes.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号