首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Polycyclic musks are widely used synthetic fragrances that have been identified during the last few years in biota samples and environmental matrices. Nevertheless, there is a lack of information concerning the photodegradation behavior of these compounds. In this work, the photoinduced degradation of six polycyclic musk compounds (Cashmeran, Celestolide, Phantolide, Galaxolide, Traseolide and Tonalide) was studied using a solid-phase microextraction (SPME) fiber as support. Musk fragrances were extracted from aqueous solutions using SPME fibers that were subsequently exposed to ultraviolet (UV) irradiation for different times. To study the degradation kinetics and to tentatively identify the photoproducts generated, gas chromatography coupled to ion trap mass spectrometry was used. Aqueous photodegradation studies were also performed. The on-fiber photodegradation approach avoids the need for further extraction processes and makes the identification of photoproducts easier, due to their higher concentration on the fibers. All musk compounds were easily photodegraded, suggesting that UV irradiation could work as a decontamination tool for these musks.  相似文献   

2.
Synthetic musks, substitutes for natural musks, are widely distributed in environment. They have been detected in water, sludge, fish, shrimp, mussels and other aquatic animals, and even in human's adipose tissue, blood and breast milk. In this study, a new extraction procedure, based on the accelerated solvent extraction (ASE) and in cell clean-up technique was developed and successfully coupled with gas chromatography-mass spectrometry (GC/MS) for the analysis of musks in sediment samples. With this method, the limits of detection as low as 0.03–0.05?ng?g?1 and the recovery rate of 86.0%–104% are achieved. When compared with soxhlet extraction (SE) and ultrasonic extraction (USE), ASE not only has the best extraction efficiency but also has advantage in extraction time and solvent consumption. Eight synthetic musks, including six polycyclic musks (Tonalide (AHTN), Galaxolide (HHCB), Phantolide (AHDI), Traseolide (ATII), Cashmeran (DPMI) and Celestolide (ADBI)) and two nitro musks (musk xylene (MX) and musk ketone (MK)), were evaluated in sediment samples collected from 15 selected locations of the Taihu lake, one of the largest freshwater lakes in China. The contents of synthetic musks in sediment samples range from 0.336 to 3.10?ng?g?1 for HHCB, 0.184 to 1.21?ng?g?1 for AHTN, below detection limit (BDL) to 0.349?ng?g?1 for MX, and BDL to 0.0786?ng?g?1 for MK. The contents of DPMI, ADBI, AHMI and ATII are below detection limit in all samples. The results reflect current status of fragrance compound pollution in this area, and provide basic data for environmental policy making.  相似文献   

3.
Nowadays, there is a special interest within the pharmaceutical laboratories to develop single enantiomer formulations and consequently a need for analytical methods to determine the enantiomeric purity of drugs. The present paper deals with the enantiomeric separation of promethazine and trimeprazine enantiomers by affinity electrokinetic chromatography (AEKC)-partial filling technique using human serum albumin (HSA) as chiral selector. A multivariate optimization of the most critical experimental variables in enantioresolution, running pH, HSA concentration and plug length, is carried out to obtain enantioresolution of promethazine and trimeprazine. The estimated maximum and optimum resolution of trimeprazine and prometazine enantiomers (Rs = 1.74 and 2.01, respectively) corresponded to the following experimental conditions: pH 7.5; [HSA] 170 μM and plug length 190 s and pH 7.6; [HSA] 170 μM and plug length 170 s, for trimeprazine and prometazine, respectively. The developed methodologies were applied for the enantiomeric quality control of promethazine and trimeprazine enantiomers in commercially available pharmaceutical formulations. Resolution, accuracy, reproducibility, cost and sample throughput of the proposed methodologies make it suitable for quality control of the enantiomeric composition of promethazine and trimeprazine in pharmaceutical preparations.  相似文献   

4.
The present paper deals with the enantiomeric separation of six antihistaminic enantiomers by affinity electrokinetic chromatography (AEKC)-partial filling technique using human serum albumin (HSA) as chiral selector. A multivariate optimization approach of the most critical experimental variables in enantioresolution, running pH, HSA concentration and HSA plug length (SPL) was carried out since there are interactions between variables that could not be considered in an univariate optimization. The estimated and experimental resolution values obtained for antihistaminic enantiomers varied from 1.13 (for orphenadrine) to 2.15 (for brompheniramine). The optimum experimental conditions for enantioresolution of each compound were: brompheniramine, pH 8.5, [HSA] 180 μM, SPL 180 s; chlorcyclizine, pH 6.5, [HSA] 180 μM, SPL 150 s; chlorpheniramine, pH 8.25, [HSA] 160 μM, SPL 150 s; hydroxyzine, pH 7.0, [HSA] 180 μM, SPL 150 s; and orphenadrine, pH 7.8, [HSA] 160 μM, SPL 150 s. pH and the quadratic term of pH seem to be the most critical factors that determine enantioresolution of antihistamines. The validity of the developed methodologies to enantiomeric quality control of antihistamines in pharmaceutical formulations is demonstrated analyzing the content of brompheniramine, chlorpheniramine and hyroxyzine enantiomers in commercially available pharmaceutical formulations containing racemic mixtures of compounds. Resolution, accuracy, reproducibility, cost and sample throughput of the proposed methodologies make them suitable for quality control of the enantiomeric composition of antihistamines in pharmaceutical preparations.  相似文献   

5.
A capillary electrophoretic method for the separation of the enantiomers of both ofloxacin and ornidazole is described. Several parameters affecting the separation were studied, including the type and concentration of chiral selector, buffer pH, voltage and temperature. Good chiral separation of the racemic mixtures was achieved in less than 16 min with resolution factors Rs = 5.45 and 6.28 for ofloxacin and ornidazole enantiomers, respectively. Separation was conducted using a bare fused-silica capillary and a background electrolyte (BGE) of 50 mM H3PO4-1 M tris solution; pH 1.85; containing 30 mg mL−1 of sulfated-β-cyclodextrin (S-β-CD). The separation was carried out in reversed polarity mode at 25 °C, 18 kV, detection wavelength at 230 nm and using hydrodynamic injection for 15 s. Acceptable validation criteria for selectivity, linearity, precision, and accuracy were studied. The limits of detection (LOD) and limits of quantitation (LOQ) of the enantiomers (ofloxacin enantiomer 1 (OF-E1), ofloxacin enantiomer 2 (OF-E2), ornidazole enantiomer 1 (OR-E1) and ornidazole enantiomer 2 (OR-E2)) were (0.52, 0.46, 0.54, 0.89) and (1.59, 1.40, 3.07, 2.70) μg mL−1, respectively. The proposed method was successfully applied to the assay of enantiomers of both ofloxacin and ornidazole in pharmaceutical formulations. The computational calculations for the enantiomeric inclusion complexes rationalized the reasons for the different migration times between the ofloxacin and ornidazole enantiomers.  相似文献   

6.
Stereospecific separations of seven Tic-hydantoin sigma-1 agonists were performed by both HPLC method using derivatized cellulose and amylose chiral stationary phases and capillary electrophoresis (CE) method using neutral and anionic cyclodextrins added in the background electrolyte (BGE). An optimal baseline separation (Rs > 3.3 with analysis times < 25 min) was readily obtained with all silica-based celluloses and amyloses using a normal-phase methodology. CE was used as an alternative technique to HPLC for the Tic-hydantoin derivatives separation. The enantiomers were fully resolved with highly sulfated β-cyclodextrins at pH 2.5 (Rs > 1.5 with analysis times <11 min). Both methods were validated in terms of linearity, detection and quantification limits. They were used to check the enantiomeric purity of the enantiomers.  相似文献   

7.
A fast enantiomeric separation of a chiral aromatic amine was achieved, using ultra high pressure liquid chromatography and highly sulfated beta-cyclodextrin (S-β-CD) as a chiral additive in the mobile phase. The stationary phase consisted of a core–shell support with a particle size of 2.7 μm. Under these conditions the base-line separation was obtained within 2.5 min. The influence of the concentration of the additive, along with the thermodynamics of the separation, was studied. Vibrational circular dichroism (VCD) spectroscopy was applied to assess the absolute configuration of the two enantiomeric analytes, as well as the interaction of these enantiomers with the S-β-CD. The VCD results revealed that S-β-CD undergoes a temperature-induced conformational change. Further, VCD experiments indicate that the interactions of the two enantiomers with the S-β-CD occur through an inclusion of the aromatic part of the analyte, as well as through electrostatic interaction between the protonated amine and the sulfate groups located at the narrow part of the S-β-CD. Molecular mechanics calculations performed according to the VCD results are consistent with experimental data, providing further evidence of these interactions.  相似文献   

8.
A chiral separation method for glycidol enantiomers determination by normal-phase high-performance liquid chromatography coupled to atmospheric pressure chemical ionization mass spectrometry was developed. Two chiral stationary phases, amylose tris-(3,5-dimethylphenylcarbamate) (Chiralpak AD-H) and (S)-indoline-2-carboxylic acid and (R)-1-(α-naphthyl) ethylamine (SUMICHIRAL OA-4900) have been investigated. The effects of the mobile phase composition, elution program and column temperature were also studied. Under the best conditions: Chiralpak AD-H column, mobile phase composition n-hexane:ethanol (70:30, v/v), flow rate of 0.8 mL/min and 40 °C column temperature, a good resolution (Rs = 1.6) for both enantiomers has been achieved with an analysis time of 16 min. The method was found to be linear in the range from 100 to 500 ppm for both glycidol enantiomers with a good determination coefficient (r2 higher than 0.99) and good precision. Limits of detection of 31 and 50 ppm for (R)-(+)-glycidol and (S)-(−)-glycidol, respectively, were obtained. The method was applied to the determination of the enantiomeric excess and yield obtained in a asymmetric epoxidation process of allyl alcohol with a chiral titanium-tartrate complex as catalyst.  相似文献   

9.
The different activity and toxicity that the enantiomers of agrochemicals may have requires the development of stereoselective analytical methodologies enabling the individual determination of each enantiomer. The aim of this work was to develop the first Electrokinetic Chromatography methodology enabling the simultaneous enantiomeric separation of carfentrazone-ethyl herbicide and its hydrolysis metabolite carfentrazone. The use of an anionic cyclodextrin as chiral selector (captisol at 2.5% (w/v)) in a 25 mM acetate buffer, at a temperature of 30 °C, and an applied voltage (reverse polarity) of −30 kV, allowed the simultaneous separation of the four enantiomers of the two compounds studied in 6.8 min with enantiomeric resolutions of 5.0 for carfentrazone-ethyl and 5.1 for carfentrazone. Analytical characteristics of the developed method were evaluated and found adequate to achieve the quantitation of carfentrazone-ethyl and carfentrazone. Analysis of a commercial herbicide formulation showed the potential of the method for the quality control of these agrochemical products. Degradation studies for carfentrazone-ethyl revealed that no significant degradation took place in cleaned sand samples while a significant but not stereoselective degradation took place in soils for the whole period of time considered (seven days).  相似文献   

10.
This work concentrates on a chiral separation technology named biphasic recognition applied to resolution of α-cyclohexylmandelic acid enantiomers by high-speed counter-current chromatography (HSCCC). The biphasic chiral recognition HSCCC was performed by adding lipophilic (−)-2-ethylhexyl tartrate in the organic stationary phase and hydrophilic hydroxypropyl-β-cyclodextrin in the aqueous mobile phase, which preferentially recognized the (−)-enantiomer and (+)-enantiomer, respectively. The two-phase solvent system composed of n-hexane-methyl tert-butyl ether–water (9:1:10, v/v/v) with the above chiral selectors was selected according to the partition coefficient and separation factor of the target enantiomers. Important parameters involved in the chiral separation were investigated, namely the types of the chiral selectors (CS); the concentration of each chiral selector; pH of the mobile phase and the separation temperature. The mechanism involved in this biphasic recognition chiral separation by HSCCC was discussed. Langmuirian isotherm was employed to estimate the loading limits for a given value of chiral selectors. Under optimum separation conditions, 3.5–22.0 mg of α-cyclohexylmandelic acid racemate were separated using the analytical apparatus and 440 mg of racemate was separated using the preparative one. The purities of both of the fractions including (+)-enantiomer and (−)-enantiomer from the preparative CCC separation were over 99.5% determined by HPLC and enantiomeric excess reached 100% for the (±)-enantiomers. Recovery for the target compounds from the CCC fractions reached 85–88% yielding 186 mg of (+)-enantiomer and 190 mg of (−)-enantiomer. The overall experimental results show that the HSCCC separation of enantiomer based on biphasic recognition, in which only if the CSs involved will show affinity for opposite enantiomers of the analyte, is much more efficient than the traditional monophasic recognition chiral separation, since it utilizes the cooperation of both of lipophilic and hydrophilic chiral selectors.  相似文献   

11.
A capillary electrophoretic method for the separation of the aminoglutethimide (AGT) enantiomers using methylated-β-cyclodextrin (M-β-CD) as chiral selector is described. Several parameters affecting the separation were studied, including the type and concentration of chiral selector, buffer pH, voltage and temperature. Good chiral separation of the racemic mixture was achieved in less than 9 min with resolution factor Rs = 2.1, using a fused-silica capillary and a background electrolyte (BGE) of tris-phosphate buffer solution (50 mmol L−1, pH 3.0) containing 30 mg mL−1 of M-β-CD. The separation was carried out in normal polarity mode at 25 °C, 16 kV and using hydrostatic injection. Acceptable validation criteria for selectivity, linearity, precision, and accuracy/recovery were included. The proposed method was successfully applied to the assay of AGT enantiomers in pharmaceutical formulations. The computational calculations for the inclusion complexes of the R- and S-AGT-M-β-CD rationalized the reasons for the different migration times between the AGT enantiomers.  相似文献   

12.
建立了以直链淀粉衍生物为手性固定相的高效液相色谱-串联质谱(HPLC-MS/MS)直接拆分普萘洛尔、美托洛尔、阿罗洛尔和卡维地洛4种β-受体阻滞剂对映体的方法。考察了手性固定相的种类、流动相改性剂和添加剂的体积分数、柱温和流速等对4种药物对映体分离的影响。结果表明:在Chiralpak AD-H手性色谱柱上,在正己烷-乙醇-二乙胺(20∶80∶0.03,v/v/v)为流动相、流速0.550 mL/min、柱温40℃的条件下,普萘洛尔、美托洛尔、阿罗洛尔和卡维地洛对映体均达到基线分离,分离度分别为1.37、1.80、2.09和4.70。通过热力学研究及对映体结构分析对拆分机理进行了探讨,发现4种药物对映体的手性拆分均为焓驱动过程,而固定相的手性空腔对不同药物的拆分影响较大。研究结果为β-受体阻滞剂的深入研究提供了参考方法。  相似文献   

13.
《Analytica chimica acta》2004,507(2):171-178
In the last years, capillary electrophoresis (CE) has gained considerable interest in pharmaceutical laboratories for controlling the chiral purity of drugs. This paper describes a simple and fast method for resolution of propranolol enantiomers by affinity capillary electrophoresis (ACE) using human serum albumin (HSA) as chiral selector. The effect of several experimental variables such as HSA concentration, temperature, chiral selector plug length and addition of organic modifiers, on the separation is evaluated. Complete enantioresolution of R- and S-propranolol was achieved in less than 5 min when the capillary was completely filled with 100 μM HSA solution and the electrophoresis was carried out with 67 mM phosphate buffer (pH 7.4) at 20 kV and 35 °C. Peaks were assigned to each propranolol enantiomer according to their relative affinities to HSA. The proposed method was applied to the analysis of pharmaceutical preparations containing propranolol. Resolution, accuracy, reproducibility, cost and sample throughput of the proposed method make it suitable for quality control of the enantiomeric composition of propranolol in pharmaceuticals.  相似文献   

14.
A direct HPLC enantioseparation of three new chiral oxadiazoline derivatives endowed with potential MAO-B inhibitory activity was accomplished on the immobilised Chiralpak IA chiral stationary phase. Multi-mg amounts of enantiomers with high enantiomeric purity (ee ≥ 98%) were rapidly collected using pure dichloromethane as eluent. The absolute configuration and chiroptical properties of the enantiomers isolated at semipreparative scale were exhaustively determined.  相似文献   

15.
A new capillary zone electrophoresis (CZE) method for the separation of omeprazole enantiomers has been developed. Methyl-β-cyclodextrin (methyl-β-CD) was chosen as the chiral selector, and several parameters, such as cyclodextrin structure and concentration, buffer concentration, pH, and capillary temperature were investigated in order to optimize separation and run times. Analysis times, shorter than 8 min were found using a background electrolyte solution consisting of 40 mM phosphate buffer adjusted to pH 2.2, 30 mM β-cyclodextrin and 5 mM sodium disulphide, hydrodynamic injection, and 15 kV separation voltage. Detection limits were evaluated on the basis of baseline noise and were established 0.31 mg/l for the omeprazole enantiomers. The proposed method was applied to five pharmaceutical preparations with recoveries between 84 and 104% of the labeled contents.  相似文献   

16.
High-performance liquid chromatography (HPLC) enantioseparation of terazosin (TER) was accomplished on the immobilised-type Chiralpak IC chiral stationary phase (CSP) under both polar organic and reversed-phase modes. A simple analytical method was validated using a mixture of methanol–water–DEA 95:5:0.1 (v/v/v) as a mobile phase. Under reversed-phase conditions good linearities were obtained over the concentration range 8.76–26.28 μg mL−1 for both enantiomers. The limits of detection and quantification were 10 and 30 ng mL−1, respectively. The intra- and inter-day assay precision was less than 1.66% (RSD%). The optimised conditions also allowed to resolve chiral and achiral impurities from the enantiomers of TER. The proposed HPLC method supports pharmacological studies on the biological effects of the both forms of TER and analytical investigations of potential drug formulations based on a single enantiomer. At the semipreparative scale, 5.3 mg of racemic sample were resolved with elution times less than 12 min using a mobile phase consisting of methanol–DEA 100:0.1 (v/v) and both enantiomers were isolated with a purity of ≥99% enantiomeric excess (ee). The absolute configuration of TER enantiomers was assigned by comparison of the measured specific rotations with those reported in the literature.  相似文献   

17.
One-step in situ microwave-assisted headspace solid-phase microextraction (MA-HS-SPME) followed by gas chromatography–mass spectrometry (GC–MS) analysis is presented as a fast and solvent-free technique to determine synthetic polycyclic musks in sewage sludge and sediment samples. Six synthetic polycyclic musks (galaxolide (HHCB), tonalide (AHTN), celestolide (ADBI), traseolide (ATII), cashmeran (DPMI) and phantolide (AHMI)) were selected in the method development and validation. The effects of extraction parameters for the quantitative extraction of these analytes by one-step MA-HS-SPME were systematically investigated. The dewatered solid sample mixed with 20-mL deionized water (containing 3 g of NaCl in a 40-mL sample-vial) was efficiently extracted by a polydimethylsiloxane-divinylbenzene (PDMS-DVB) fiber placed in the headspace when the extraction slurry was microwave irradiated at 80 W for 5 min. The limits of detection (LODs) ranged from 0.04 to 0.1 ng/g, and the limits of quantification (LOQs) ranged from 0.1 to 0.3 ng/g (fresh weight). A preliminary analysis of sludge and sediment samples revealed that HHCB and AHTN were the two most commonly detected synthetic polycyclic musks; using a standard addition method, their total concentrations were determined to range from 0.3 to 10.9 ng/g (fresh weight) with relative standard deviation (RSD) ranging from 4% to 10%.  相似文献   

18.
The present work describes for the first time the use of SPME coupled to LC–MS/MS employing the polar organic mode in a stereoselective fungal biotransformation study to investigate the fungi ability to biotransform the drug risperidone into its chiral and active metabolite 9-hydroxyrisperidone (9-RispOH). The chromatographic separation was performed on a Chiralcel OJ-H column using methanol:ethanol (50:50, v/v) plus 0.2% triethylamine as the mobile phase at a flow rate of 0.8 mL min−1. The SPME process was performed using a C18 fiber, 30 min of extraction time and 5 min of desorption time in the mobile phase. The method was completely validated and all parameters were in agreement with the literature recommendations. The Cunninghamella echinulata fungus was able to biotransform risperidone into the active metabolite, (+)-9-RispOH, resulting in 100% of enantiomeric excess. The Cunninghamella elegans fungus was also able to stereoselectively biotransform risperidone into (+)- and (−)-9-RispOH enantiomers at different rates.  相似文献   

19.
Two amino acid-based (leucine and isoleucine) alkenoxy micelle polymers were employed in this study for the separation of multichiral center-bearing beta-blockers, nadolol and labetalol. These polymers include polysodium N-undecenoxy carbonyl-L-leucinate (poly-L-SUCL) and polysodium N-undecenoxy carbonyl-L-isoleucinate (poly-L-SUCIL). Detailed synthesis and characterization were reported in our previous paper [26]. It was found that poly-L-SUCIL gives better chiral separation than poly-L-SUCL for both nadolol and labetalol isomers. The use of 50-100 mM poly-L-SUCIL as a single chiral selector provided separation of four and three isomers of labetalol and nadolol, respectively. Further optimization in separation of both enantiomeric pairs of nadolol and labetalol was achieved by evaluation of type and concentration of organic solvents, capillary temperature as well type and concentration of cyclodextrins. A synergistic approach, using a combination of poly-L-SUCIL and sulfated beta-CD (S-beta-CD) was evaluated and it showed dramatic separation for enantiomeric pairs of nadolol. On the other hand for labetalol enantiomers, separation was slightly decreased or remain unaffected using the dual chiral selector system. Finally, simultaneous separation of both nadolol and labetalol enantiomers was achieved in a single run using 25 mM poly-L-SUCIL and 5% w/v of S-beta-CD in less then 35 min highlighting the importance of high-throughput chiral analysis.  相似文献   

20.
In rural parts of South Africa the organochlorine insecticide DDT (1,1,1-trichloro-2,2-bis(p-chlorophenyl)ethane) is still used for malaria vector control where traditional dwellings are sprayed on the inside with small quantities of technical DDT. Since o,p′-DDT may show enantioselective oestrogenicity and biodegradability, it is important to analyse enantiomers of o,p′-DDT and its chiral degradation product, o,p′-DDD, for both health and environmental-forensic considerations. Generally, chiral analysis is performed using heart-cut multidimensional gas chromatography (MDGC) and, more recently, comprehensive two-dimensional gas chromatography (GC × GC). We developed an off-line gas chromatographic fraction collection (heart-cut) procedure for the selective capturing of the appropriate isomers from a first apolar column, followed by reinjection and separation on a second chiral column. Only the o,p′-isomers of DDT and DDD fractions from the first dimension complex chromatogram (achiral apolar GC column separation) were selectively collected onto a polydimethylsiloxane (PDMS) multichannel open tubular silicone rubber trap by simply placing the latter device on the flame tip of an inactivated flame ionisation detector (FID). The multichannel trap containing the o,p′-heart-cuts was then thermally desorbed into a GC with time-of-flight mass spectrometry detection (GC–TOFMS) for second dimension enantioselective separation on a chiral column (β-cyclodextrin-based). By selectively capturing only the o,p′-isomers from the complex sample chromatogram, 1D separation of ultra-trace level enantiomers could be achieved on the second chiral column without matrix interference. Here, we present solventless concentration techniques for extraction of DDT from contaminated soil and air, and report enantiomeric fraction (EF) values of o,p′-DDT and o,p′-DDD obtained by a new multidimensional approach for heart-cut gas chromatographic fraction collection for off-line second dimension enantiomeric separation by 1D GC–TOFMS of selected isomers. This multidimensional method is compared to the complementary technique of comprehensive GC × GC–TOFMS using the same enantioselective column, this time as the first dimension of separation.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号