共查询到20条相似文献,搜索用时 15 毫秒
1.
Eghbali H Sandra K Detobel F Lynen F Nakanishi K Sandra P Desmet G 《Journal of chromatography. A》2011,1218(21):3360-3366
A systematic study is reported on the performance of long monolithic capillary columns in gradient mode. Using a commercial nano-LC system, reversed-phase peptide separations obtained through UV-detection were conducted. The chromatographic performance, in terms of conditional peak capacity and peak productivity, was investigated for different gradient times (varying between 90 and 1320min) and different column lengths (0.25, 1, 2 and 4m) all originating from a single 4m long column. Peak capacities reaching values up to n=10(3) were measured in case of the 4m long column demonstrating the high potential of these long monoliths for the analysis of complex biological mixtures, amongst others. In addition, it was found that the different column fragments displayed similar flow resistance as well as consistent chromatographic performance in accordance with chromatographic theory indicating that the chromatographic bed of the original 4m long column possessed a structural homogeneity over its entire length. 相似文献
2.
Jaafar J Watanabe Y Ikegami T Miyamoto K Tanaka N 《Analytical and bioanalytical chemistry》2008,391(7):2551-2556
An anion exchange monolithic silica capillary column was prepared by surface modification of a hybrid monolithic silica capillary
column prepared from a mixture of tetramethoxysilane (TMOS) and methyltrimethoxysilane (MTMS). The surface modification was
carried out by on-column copolymerization of N-[3-(dimethylamino)propyl]acrylamide methyl chloride-quaternary salt (DMAPAA-Q) with 3-methacryloxypropyl moieties bonded
as an anchor to the silica surface to form a strong anion exchange stationary phase. The columns were examined for their performance
in liquid chromatography (LC) and capillary electrochromatography (CEC) separations of common anions. The ions were separated
using 50 mM phosphate buffer at pH 6.6. Evaluation by LC produced an average of 30,000 theoretical plates (33 cm column length)
for the inorganic anions and nucleotides. Evaluation by CEC, using the same buffer, produced enhanced chromatographic performance
of up to ca. 90,000 theoretical plates and a theoretical plate height of ca. 4 μm. Although reduced efficiency was observed
for inorganic anions that were retained a long time, the results of this study highlight the potential utility of the DMAPAA-Q
stationary phase for anion separations.
Figure Micro-LC performance evaluation of a strong anion exchange silica monolith column, 100H-MOP-DMAPAA-Q, 33 cm in length, with
a mobile phase of 50 mM phosphate buffer, pH 2.8; linear velocity: u = 1.8 mm/s; UV-Vis detection at 254 nm. Sample solution (5 mg/mL of each component, 4 mL) was injected in split flow injection
mode at a split ratio of ca. 1:1900 with a pump flow rate of 1.5 mL/min 相似文献
3.
A novel stationary phase triacontyl-functionalized monolithic silica capillary column was successfully prepared for reversed-phase capillary liquid chromatography. The performance of the monolithic silica capillary column coated with triacontyl chain for the separation of alkylbenzenes, xylene isomers, polycyclic aromatic hydrocarbons, and mixture of α- and β-carotenes was studied, which was compared to that using the monolithic silica capillary column coated with octadecyl chain. The comparison results showed that triacontyl-functionalized monolithic silica capillary column would be a promising media to be used for the separation of isomeric solutes with long chain in reversed-phase capillary liquid chromatography. 相似文献
4.
Hydrothermal preparation of hybrid carbon/silica monolithic capillary column for liquid chromatography
下载免费PDF全文
![点击此处可从《Journal of separation science》网站下载免费的PDF全文](/ch/ext_images/free.gif)
A simple, easy and economical approach for the preparation of a hybrid carbon/silica monolithic capillary column was described for the first time by using silica monolith as framework in combination with hydrothermal carbonization at 180°C. During the preparation process, formamide was introduced to the reaction solutions to reduce the dissolution rate of monolithic silica skeleton and its optimal concentration was 1.5 M. Fourier transform infrared spectrometry, scanning electron microscopy, energy dispersive X‐ray spectrometry, and inverse size exclusion chromatography were carried out to characterize the as‐prepared column. The results demonstrated that carbon spheres ranging from 150 to 1000 nm were successfully attached to the surface of silica skeleton. The prepared hybrid carbon/silica column had a permeability of 4.4 × 10?14 m2. Chromatographic performance of the column was evaluated by separation of various compounds including alkylbenzenes, nucleosides and bases, and aromatic acids. The column exhibited an efficiency of 75 000 plates/m for butylbenzene at the optimal linear velocity of 0.23 mm/s. The successful separation of these compounds and the study on mechanism indicated that the column can be applied in mixed‐mode chromatography. 相似文献
5.
A polydimethylsiloxane (PDMS)-modified monolithic silica column was prepared for performing reversed-phase capillary liquid chromatography. The prepared PDMS column has a permeability of 6.4×10(-14) m(2) with a plate height <9.2 μm. Alkylbenzenes and polycyclic aromatic hydrocarbons (PAHs) were well separated with the PDMS stationary phase, which exhibited similar selectivity and separation mechanism to that of octadecyl stationary phase. The hydrophobic interactions between the analytes and the PDMS stationary phase mainly play the roles for the separation of alkylbenzenes and PAHs. The characteristics of the PDMS column for the separation of alkylbenzenes and PAHs demonstrated that it would be a promising alternative to the octadecyl column. 相似文献
6.
Zian Lin Hui Huang Shihua LiJuan Wang Xiaoqing TanLan Zhang Guonan Chen 《Journal of chromatography. A》2013,1271(1):115-123
A phenylboronic acid-silica hybrid monolithic column for capillary liquid chromatography (cLC) was prepared through one-pot process by using 4-vinylphenylboronic acid (VPBA) and alkoxysilanes simultaneously. The effects of the molar ratio of tetramethyloxysilane/γ-methacryloxypropyltrimethoxysilane (TMOS/γ-MAPS), amount of VPBA, and the volume of diethylene glycol (DEG) on the morphologies, permeabilities and pore properties of the prepared VPBA-silica hybrid monolithic columns were studied in detail. A relatively uniform monolithic structure with high porosity was obtained with optimized ingredients. A series of cis-diol-containing compounds, alkylbenzenes, amides, and anilines were utilized to evaluate the retention behaviors of the VPBA-silica hybrid monolithic column. The result demonstrated that the prepared VPBA-silica hybrid monolithic column exhibited multiple interactions including hydrophobicity, hydrophilicity, as well as cation exchange apart from the expected affinity interaction. The run-to-run, column-to-column and batch-to-batch reproducibility of the VPBA-silica hybrid monolith were satisfactory with the relative standard deviations (RSDs) less than 1.63% (n = 5), 2.02% (n = 3) and 2.90% (n = 5), respectively, indicating the effectiveness and practicability of the proposed method. In addition, the VPBA-silica hybrid monolithic column was further applied to the separation of proteins and tryptic digest of bovine serum albumin (BSA), respectively. The successful applications suggested the potential of the VPBA-silica hybrid monolith in proteome analysis. 相似文献
7.
8.
Lianbing Ren Yunchun LiuMingming Dong Zhen Liu 《Journal of chromatography. A》2009,1216(47):8421-8425
Boronate affinity chromatography is an important tool for specific isolation of cis-diol-containing compounds such as glycoproteins, RNA and carbohydrates. Boronate functionalized monolithic capillaries have been recently developed for specific capture of cis-diol-containing small biomolecules, but the apparent hydrophobicity of the columns prevents them from specific capture of glycoproteins. In this paper, a hydrophilic boronate affinity monolithic capillary was prepared by in situ free radical polymerization, using 4-vinylphenylboronic acid (VPBA) and N, N′-methylenebisacrylamide (MBAA) as functional monomer and cross-linker, respectively. The prepared poly(VPBA-co-MBAA) monolithic capillary exhibited uniform open channel network and high density of accessible boronic acid. Due to the utilization of hydrophilic cross-linker, the prepared column was hydrophilic, allowing for specific capture of glycoproteins. 相似文献
9.
A simple cladding procedure was developed to apply monolithic silica rods in chromatography. This was used to evaluate the performances of new monolithic silica phases synthesised using a triblock copolymer as a phase separation inducer. The cladding procedure is found efficient after several tests, including scanning electron microscopy and mercury porosimetry, and the obtained columns present a relatively good efficiency in adsorption chromatography (H min is about 50 μm) as compared to other lab-scale developed columns. 相似文献
10.
Minghuo Wu Yingzhuang Chen Ren’an Wu Ruibing Li Hanfa Zou Bo Chen Shouzhuo Yao 《Journal of chromatography. A》2010,1217(26):4389-4394
A chloropropyl-functionalized silica (CP-silica) hybrid monolithic column was synthesized within the confines of a capillary via the sol–gel process using tetramethoxysilane (TMOS) and (3-chloropropyl)-trimethoxysilane (CPTMS) as the precursors. The resulting CP-silica hybrid monolith inside the capillary showed homogeneous macroporous morphology and was well attached to the inner wall of the capillary. The obtained CP-silica hybrid monolithic capillary column demonstrated the inherent hydrophobic property and could be applied as a reversed-phase stationary phase in CEC directly. Due to the great chemical reactivity of the incorporated chloro groups on the hybrid silica monolithic matrix, the chloropropyl moieties on the surface of the hybrid silica monolith matrix could be conveniently further modified by a tertiary amine of N,N-dimethyl-N-dodecylamine (DMDA) via the nucleophilic substitution reaction at 70 °C to introduce a dodecyl groups (C12) onto the CP-silica hybrid monolithic matrix. The resulting C12-silica hybrid monolithic column not only demonstrated the significantly enhanced hydrophobic property in the separation of alkylbenzenes in reversed-phase capillary electrochromatography (RP-CEC), but also the strong electroosmotic flow (EOF) in a wide pH range. Five alkylbenzenes could be baseline separated in 3 min with column efficiency ranging from 189 700 to 221 000 N/m with a 70% ACN running buffer in CEC. 相似文献
11.
Kareem Yusuf Amro K. F. Dyab Zeid A. ALOthman Ahmed Yacine Badjah-Hadj-Ahmed 《液相色谱法及相关技术杂志》2016,39(16):752-761
Sporopollenin microparticles have been prepared form Lycopodium clavatum spores, defatted and incorporated into a porous methacrylate polymer monolith to enhance liquid chromatographic performance of different sets of small neutral molecules. A stable suspension between sporopollenin microparticles and porogenic solvents composed of 1-propanol and 1,4-butandiol has proved before preparation, and seven compositions with increasing sporopollenin microparticles were prepared inside fused silica tubing. After optimizing of the preparation conditions, the structure of the stationary phase was characterized by scanning electron microscopy, surface area analysis, thermodynamic study, short- and long-term precision, and hydrodynamic properties including mechanical stability, porosity, and permeability. The columns were successfully applied to improve the separation efficiency of different mixtures using capillary liquid chromatography. Addition of very small amount of sporopollenin microparticles to the methacrylate mixture enhanced the column efficiency from 3 to 5 times for ketonic and phenolic compounds and reduced the retention with the corresponding better resolution and peak shapes for all studied compounds. 相似文献
12.
A novel designed electro-osmotic pump (EOP) with simple structure was assembled using three 20 cm x 530 microm i.d. fused-silica capillaries packed with 20 +/- 5 nm silica grains for capillary liquid chromatography. It was found that the pump could generate pressures over 20 MPa and several microL/min flow rate for most of the liquids being delivered with the applied voltage less than 10 kV. By increasing the pressure, decreasing the applied voltage and the electrical current, the thermodynamic efficiency was about 1-4%. A practical application of the EOP in a 20cm x 150 microm i.d. 3 microm C18 fused-silica analytical capillary column demonstrated the applicability of the pump. 相似文献
13.
A novel ionic liquid (IL) monolithic capillary column was successfully prepared by thermal free radical copolymerization of IL (1-vinyl-3-octylimidazolium chloride, ViOcIm+Cl−) together with lauryl methacrylate (LMA) as the binary functional monomers and ethylene dimethacrylate (EDMA) as the cross-linker in binary porogen. The proportion of monomers, porogens and cross-linker in the polymerization mixture was optimized in detail. The resulting IL-monolithic column could not only generate a stable reversed electroosmotic flow (EOF) in a wide pH range (2.0–12.0), but also effectively eliminate the wall adsorption of the basic analytes. The obtained IL-monolithic columns were examined by scanning electron microscopy (SEM) and Fourier transform infrared (FT-IR). These results indicated that the IL-monolithic capillary column possessed good pore properties, mechanical stability and permeability. The column performance was also evaluated by separating different kinds of compounds, such as alkylbenzenes, thiourea and its analogues, and amino acids. The lowest plate height of ∼6.8 μm was obtained, which corresponded to column efficiency (theoretical plates, N) of ∼147,000 plates m−1 for thiourea. ILs, as a new type of functional monomer, present a promising option in the fabrication of the organic polymer-based monolithic columns in CEC. 相似文献
14.
A simple approach to fabricate hybrid monolithic column within the confines of fused-silica capillaries (75 μm i.d.) was introduced. A polyhedral oligomeric silsesquioxanes (POSS) reagent containing a methacrylate group was selected as functional monomer, and copolymerized with bisphenol A dimethacrylate (BPADMA) or ethylene dimethacrylate (EDMA) in the presence of porogenic solvents via thermally initiated free radical polymerization. After optimization of the preparation conditions, two POSS-containing hybrid monoliths were successfully prepared and exhibited good permeability and stability. By comparison of the separation efficiencies of the resulting poly(POSS-co-BPADMA) and poly(POSS-co-EDMA) monoliths in capillary electrochromatography (CEC) and capillary liquid chromatography (cLC), it was indicated the former has better column efficiencies for alkylbenzenes, phenols, anilines and PAHs in CEC and cLC than the latter. Particularly, the hybrid poly(POSS-co-BPADMA) monolith is more suitable for separation of PAHs due to π–π interaction between the analytes and aromatic rings in the surface of monolithic stationary phase. 相似文献
15.
A silica-based CEC monolithic column with mixed modes of RP and weak anion-exchange (WAX) was successfully prepared by using the sol-gel technique at mild temperature. The synthesizing procedure was optimized by changing the ratios of tetraethoxysilane (TEOS), aminopropyltriethoxysilane (APTES), and octyltriethoxysilane (C(8)-TEOS) in the mixture. While serving as WAX group, the amino group dominated the charge on the surface of the capillary column and generated an EOF from cathode to anode at low pH. At pH above 7.5, a cathodic EOF was observed due to the full ionization of silanol group and the suppression in the ionization of amino group. The morphology of monolithic columns was examined by SEM, and the performance of column was evaluated in detail by separating different kinds of compounds. As expected, the monolithic column exhibited RP chromatographic behavior for neutral solutes. Fast and efficient separation of six aromatic acids was obtained using acidic mobile phase with column efficiency up to 160,000 plates/m. Symmetrical peaks can be obtained for aromatic amines because positively charged amino groups on the surface can effectively minimize the adsorption of positively charged analytes to the stationary phase. 相似文献
16.
An ionic liquid, 1-butyl-3-methylimidazolium tetrafluoroborate ([BMIM][BF4]) was introduced as dynamic coating of a silica monolithic column for capillary electrochromatography of phenols and nucleoside monophosphates. The run-to-run and column-to-column repeatability of migration time for six phenols were satisfactory on this column with relative standard deviation values less than 0.90 and 4.31%, respectively. Anodic electroosmotic flow (EOF) was observed, which increased with the increase of [BMIM][BF4] concentration within 120 mM and when [BMIM][BF4] concentration was above 120 mM, EOF leveled off due to the saturation of [BMIM][BF4] on the monolith. Efficient separation of phenols and nucleoside monophosphates on this dynamically coated monolithic column was obtained, compared with a dynamically coated fused-silica column and unmodified silica monolithic column. The retention behavior of uncharged phenols is mainly manipulated by hydrophobic interactions due to the presence of butyl groups, and that of nucleoside monophosphates is governed by the electrostatic attraction mechanism based on the interaction between positively charged [BMIM][BF4] moieties and negatively charged phosphate groups. In addition, silica matrix also contributes to the separation resolution. 相似文献
17.
A novel cationic hydrophilic interaction monolithic stationary phase based on the chemical modification of carboxymethyl chitosan (CMCH) to the monolithic silica skeleton using carbodiimide as an activation reagent was prepared for performing capillary liquid chromatography. The amino and hydroxy moieties of CMCH functioned as both the ion-exchange sites and polar providers. The performance of the column was studied by the separation of polar acidic compounds. The chitosan functionalized monolithic silica column showed good selectivity for nucleosides, nucleotides, aromatic acids and aliphatic acids. The mechanism for the separation of these compounds was also studied. The results showed that these compounds were separated primarily based on the hydrophilic interaction mechanism. 相似文献
18.
19.
A facile approach was exploited for fast preparation of polymer-based monoliths in UV-transparent fused-silica capillaries via “one-pot” photo-initiated thiol-acrylate polymerization reaction of dipentaerythritolpenta-/hexaacrylate (DPEPA) and 1-octadecanethiol (ODT) in the presence of porogenic solvents (1-butanol and ethylene glycol). Due to relative insensitivity of oxygen inhibition in thiol-ene free-radical polymerization, the polymerization could be performed within 5 min. The effects of composition of prepolymerization solution on the morphology and permeability of poly(ODT-co-DPEPA) monoliths were investigated in detail by adjusting the content of monomer and binary porogen ratio. The physical properties of poly(ODT-co-DPEPA) monoliths were characterized by Fourier transform infrared spectroscopy (FT-IR), mercury intrusion porosimetry (MIP) and nitrogen adsorption/desorption measurement. The evaluation of chromatographic performance was carried out by capillary liquid chromatography (cLC). The results indicated that the poly(ODT-co-DPEPA) monolith was homogeneous and permeable, and also possessed a typical reversed-phase retention mechanism in cLC with high efficiency (∼75,000 N m−1) for separation of alkylbenzenes. Eventually, the further separation of tryptic digest of proteins by cLC tandem mass spectrometry (cLC-MS/MS) demonstrated its potential in the analysis of biological samples. 相似文献
20.
Shu S Kobayashi H Kojima N Sabarudin A Umemura T 《Journal of chromatography. A》2011,1218(31):5228-5234
Poly(lauryl methacrylate-co-ethylene dimethacrylate) monoliths were in situ synthesized within the confines of a silicosteel tubing of 1.02 mm i.d. and 1/16" o.d. for microbore reversed-phase HPLC. In order to obtain practically useful monoliths with adequate column efficiency, low flow resistance, and good mechanical strength, some parameters such as total monomer concentration (%T), cross-linking degree (%C) and polymerization temperature were optimized. High-efficiency monoliths were successfully obtained by thermal polymerization of a monomer mixture (40%T, 10%C) with a binary porogenic solvent consisting of 1-propanol and 1,4-butandiol (7:4, v/v) at a high temperature of 90 °C. The morphology and porous structure of the resulting monoliths were assessed by scanning electron microscope (SEM) and inverse size exclusion chromatography (ISEC), while the column performance was evaluated through the separations of a series of alkylbenzenes in acetonitrile-water (50:50, v/v) eluent. At a normal flow rate of 50 μL/min (corresponding to 1.66 mm/s), the optimized monolithic columns typically exhibited theoretical plate numbers of 6000 plates/10 cm-long column for amylbenzene (k>40), and the pressure drop was always less than 1 MPa/10 cm. The monoliths, which were chemically anchored to the tube inner wall surface using a bifunctional silylation agent, exhibited adequate mechanical strength of up to 12-13 MPa, and were properly operated at 10 times higher flow rate than normal, reducing the separation time to one tenth. The lauryl methacrylate-based monolithic column was applied to a rapid and efficient separation of ten common proteins such as aprotinin, ribonuclease A, insulin, cytochrome c, trypsin, transferrin, conalbumin, myoglobin, β-amylase, and ovalbumin in the precipitation-redissolution mode. Using a linear CH(3)CN gradient elution at a flow rate of 500 μL/min (10-times higher flow rate), 10 proteins were baseline separated within 2 min. 相似文献