首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
In order to analyze amino acids sensitively without derivatization, we have developed carrier-mediated single drop microextraction (SDME). Nonane-1-sulfonic acid was added to an acidic sample donor solution as a carrier to form neutral ion pair complexes with amino acids. The ion pair complexes were extracted to the organic phase, covering a drop of an aqueous basic acceptor phase hanging at the tip of a capillary, and then back-extracted to the basic acceptor phase, where both the amino acids and the carrier have negative charges and the ion pair complexes are broken. The resulting extract of enriched amino acids was injected into the capillary and analyzed by capillary electrophoresis. With 20-min SDME with agitation of the donor phase, enrichment factors of four aromatic amino acids were up to 120-fold, yielding the LOD of 70-500 nM. The linear dynamic ranges for corrected peak areas were 1-100 μM with linear correlation coefficients larger than 0.9959. With internal standardization, the intraday RSDs of migration times and corrected peak areas were 0.01-0.04% and 2.0-3.7%, respectively. The capabilities of sample cleanup including desalting and preconcentration of carrier-mediated SDME were demonstrated with the analysis of human urine after minimal pretreatment of acidification and centrifugation.  相似文献   

2.
Automated coupling of headspace‐single drop microextraction (HS‐SDME) and CE has been demonstrated using a commercial CE instrument. When a drop hanging at the inlet tip of a capillary for CE is used as the acceptor phase, HS‐SDME becomes a simple but powerful sample pretreatment technique for CE before injection to facilitate sample cleanup and enrichment. By combining HS‐SDME with an on‐line sample preconcentration technique, large volume sample stacking using an electroosmotic flow pump, the sensitivity can be improved further. The overall enrichment factors for phenolic compounds were from 1900 to 3400. HS‐SDME large volume sample stacking using an electroosmotic flow pump was successfully applied to a red wine sample to obtain an LOD of 4 nM (0.8 ppb) for 2,4,6‐trichlorophenol which is a precursor for 2,4,6‐trichloroanisole causing the foul odor in wine called cork taint.  相似文献   

3.
Single drop microextraction (SDME) is a convenient and powerful preconcentration method for CE before injection. By simple combination of sample‐handling sequences without modification of the CE apparatus, a drop of an aqueous acceptor phase covered with a thin organic layer was formed at the tip of a capillary; 10 min SDME of fluorescein and 6‐carboxyfluorescein from a donor phase of pH 1 to an acceptor phase of pH 9 provided 110‐fold enrichments without stirring the donor phase. To improve the concentration effect further, SDME was coupled with an on‐line (after injection) sample preconcentration method, sweeping, in which analytes in a long sample zone are accumulated at the boundary of a pseudostationary phase penetrating into the sample zone. It is thus necessary to inject a sample of much larger volume than that of a drop in typical SDME. A Teflon sleeve over the capillary inlet allowed a large volume drop to be held stably during extraction. By in‐line coupling 10 min SDME and sweeping of a 30 nL sample using a cationic surfactant dodecyltrimethylammonium, enrichment factors of the double preconcentration were increased up to 32 000.  相似文献   

4.
A highly sensitive method for chiral analysis of amino acids by in-line single drop microextraction (SDME) and chiral capillary electrophoresis (CE) with laser-induced fluorescence (LIF) detection was developed. In SDME, a drop of a basic aqueous acceptor phase covered with a thin organic layer was formed at the tip of a capillary by simple combination of sample-handling sequences of a CE apparatus. Then fluorescein isothiocyanate (FITC)-derivatized amino acids in an acidic donor solution were enriched into the drop through the organic layer. The enriched enantiomers were then resolved using a dual chiral selector of β-cyclodextrin (β-CD) and sodium taurodeoxycholate (STC). Here, in addition to serving as a labeling reagent providing high fluorescence signal, hydrophobic FITC was primarily used as a modifier aiding the extraction of zwitterionic amino acids by blocking the amino groups and increasing the hydrophobicity, yielding 220 times increase in extraction efficiency. Several hundred-fold enrichments were achieved with 10 min SDME, yielding LODs of 30-60 pM and enabling direct analysis of d-AAs in a 99% enantiomeric excess mixture. In view of no additional modification of the existing commercial CE instrument, this method without stirring can be easily realized using known operations. When a microstirrer was customized to the CE instrument several thousand-fold enrichments could be obtained with LODs in the low picomolar range of 1-3 pM.  相似文献   

5.
A simple in‐line single drop liquid–liquid–liquid microextraction (SD‐LLLME) coupled with CE for the determination of two fluoroquinolones was developed. The method is capable to quantify trace amount of analytes in water samples and to improve the sensitivity of CE detection. For the SD‐LLLME, a thin layer of organic phase was used to separate a drop of 0.1 M NaOH hanging at the inlet of the capillary from the aqueous donor phase. By this way, the analytes were extracted to the acceptor phase through the organic layer based on their acidic/basic dissociation equilibrium. The drop was immersed into the organic phase during 10 min for extraction and then it is directly injected into the capillary for the analysis. Parameters such as type and volume of organic solvent phase, aqueous donor, and acceptor phases and extraction time and temperature were optimized. The enrichment factor was calculated, resulting 40‐fold for enrofloxacin (ENR) and sixfold for ciprofloxacin (CIP). The linear range were 20–400 μg/L for ENR and 60–400 μg/L for CIP. The detection limits were 10.1 μg/L and 55.3 μg/L for ENR and CIP, respectively, and a good reproducibility was obtained (4.4% for ENR and 5.6% for CIP). Two real water samples were analysed applying the new method and the obtained results presented satisfactory recovery percentages (90–100.3%).  相似文献   

6.
Headspace (HS) extraction is a sample pretreatment technique for volatile and semivolatile organic compounds in a complex matrix. Recently, in-tube microextraction (ITME) coupled with CE using an acceptor plug placed in the capillary inlet was developed as a simple but powerful HS extraction method. Here, we present single bubble (SB) ITME using a bubble hanging to the capillary inlet immersed in a sample donor solution as a HS of submicroliter volume (∼200 nL). The analytes evaporated to the bubble were extracted into the acceptor phase through the capillary opening, then electrophoresis of the enriched extract was carried out. Since the bubble volume was much smaller than a conventional HS volume (∼1 mL), it was filled with the evaporated analytes rapidly and the analytes could be enriched much faster compared to conventional HS-ITME. Owing to the high surface-to-volume ratio of the SB, 5 min SB-ITME yielded the enrichment factor values similar to those of 10 min HS-ITME. When 5 min SB-ITME at room temperature was applied to a tap water sample, the enrichment factors of 2,4,6-trichlorophenol (TCP), 2,3,6-TCP, and 2,6-dichlorophenol were 53, 41, and 60, respectively, and the LOQs obtained by monitoring the absorbance at 214 nm were 5.6–8.3 ppb, much lower than 200 ppb, the World Health Organization guideline for the maximum permissible concentration of 2,4,6-TCP in drinking water.  相似文献   

7.
Gao W  Chen G  Chen T  Zhang X  Chen Y  Hu Z 《Talanta》2011,83(5):259-1679
A simple and novel method of directly suspended droplet microextraction (DSDME) combined with single drop back-extraction prior to capillary electrophoresis (CE) measurement is developed. In this technique, DSDME was firstly carried out under the maximum stirring rate for a desired time. Then, an aqueous droplet as back-extractive phase suspended at the needle tip was immersed in droplet of organic phase for back-extracted. After extraction, the aqueous droplet was transferred into a suitable vial and injected into CE for analysis. Three alkaloids were selected as model compounds for developing and evaluating the method performance. Under the optimum conditions, the enrichment factors ranged from 231 to 524. The relative standard deviations for five replicates were in the range of 4.8-8.1%. The calibration graph was linear in the range of 20-1000 ng mL−1 yielding correlation coefficients higher than 0.9983. The limit of detections varied from 8.1 to 14.1 ng mL−1. Human urine samples were spiked with three alkaloids standard to assess the matrix effects and satisfactory results were obtained. The advantages of this method are simplicity of operation, rapid detection, low cost, high enrichment factor and little solvent consumption.  相似文献   

8.
In the present work the determination of benzene, toluene, ethylbenzene and o-xylene (BTEX) in environmental sample solutions using gas chromatography with flame ionisation detection (GC-FID) combined with three different sampling techniques, such as; direct single drop microextraction (DI-SDME), headspace single drop microextraction (HS-SDME) and ultrasonic assisted HS-SDME, were compared. In all of these techniques, for the determination of BTEX, the experimental parameters such as organic solvent effect, extraction time, agitation speed and salting effect were optimised. At their optimised conditions of operation the detection limits, times of extraction and precision for the three techniques are established. A detailed comparison of the analytical performance characteristics of these techniques for final GC-FID determination of BTEX in water samples was given. The technique provided a linear range of 50–20000?ng?mL–1 for DI-SDME and 10–20000?ng?mL–1 for HS-SDME methods, good repeatability (RSDs <4.72–7.74% for DI-SDME and 1.80–7.05% for HS-SDME (n?=?5), good linearity (r?≥?0.9978) and limits of detection (LODs) in the range of 0.006–10?ng?mL?1 for DI-SDME, 0.1–3?ng?mL–1 for HS-SDME methods (S/N?=?3). Then the optimised techniques were also applied to real samples (river and waste waters) containing BTEX and similar precision (RSD?<?8.2,?n?=?3) was obtained.  相似文献   

9.
An analytical technique of in-line coupling headspace liquid-phase microextraction (HS-LPME) with capillary electrophoresis (CE) was proposed to determine volatile analytes. A special cover unit of the sample vial was adopted in the coupling method. To evaluate the proposed method, phenols were used as model analytes. The parameters affecting the extraction efficiency were investigated, including the configuration of acceptor phase, kind and concentration of acceptor solution, extraction temperature and time, salt-out effect, sample volume, etc. The optimal enrichment factors of HS-LPME were obtained with the sample volume of about half of sample vials, which were confirmed by both the theoretical prediction and experimental results. The enrichment factors were obtained from 520 to 1270. The limits of detection (LODs, S/N = 3) were in the range from 0.5 to 1 ng/mL each phenol. The recoveries were from 87.2% to 92.7% and the relative standard deviations (RSDs) were lower than 5.7% (n = 6). The proposed method was successfully applied to the quantitative analysis of the phenols in tap water, and proved to be a simple, convenient and reliable sample preconcentration and determination method for volatile analytes in water samples.  相似文献   

10.
朱婧  李明昕  王倩  任琳  郑波  雍莉  邹晓莉 《色谱》2016,34(11):1120-1125
建立了悬浮固化分散液液微萃取-毛细管电泳法同时测定水中磺酰脲类除草剂残留的方法。以十二醇为萃取剂、甲醇为分散剂,采用悬浮固化分散液液微萃取技术对水样进行分离提取,并结合毛细管电泳法进行测定。该方法可以有效提取、分离、检测水中残留的微量苯磺隆、吡嘧磺隆、苄嘧磺隆等9种磺酰脲类除草剂,各待测物在10.0~1000 μg/L范围内线性关系良好,相关系数r≥0.992,方法检出限为2.40~7.50 μg/L,方法精密度为6.55%~13.9%。将该方法用于实际水样的测定,取得了较满意的结果,加标回收率为82.0%~104%。该方法简便快速,适合水中磺酰脲类除草剂的同时测定。  相似文献   

11.
Twenty underivatized essential amino acids were separated using capillary zone electrophoresis and consequently detected with contactless conductivity detection (CCD). A simple acidic background electrolyte (BGE) containing 2.3 M acetic acid and 0.1% w/w hydroxyethylcellulose (HEC) allowed the electrophoretic separation and sensitive detection of all 20 essential amino acids in their underivatized cationic form. The addition of HEC to the BGE suppressed both, electroosmotic flow and analyte adsorption on the capillary surface resulting in an excellent migration time reproducibility and a very good analyte peak symmetry. Additionally, the HEC addition significantly reduced the noise and long-term fluctuations of the CCD baseline. The optimized electrophoretic separation method together with the CCD was proved to be a powerful technique for determination of amino acid profiles in various natural samples, like beer, yeast, urine, saliva, and herb extracts.  相似文献   

12.
Wang J  Chen G 《Talanta》2003,60(6):1239-1244
A method based on microchip capillary electrophoresis with amperometric detection was developed for the rapid separation and direct detection of oxidizable aromatic amino acids (without prior derivatization). The working electrode was a thick-film carbon strip electrode positioned opposite the outlet of the separation channel. Factors influencing the separation and detection processes were examined and optimized. The five aromatic amino acids, tyrosine, 5-hydroxytryptophan, tryptophan, p-aminobenzoic acid, and m-aminobenzoic acid, can be well separated within 5 min using a separation voltage of 2000 V and a 25 mM phosphate buffer (pH 7.0) run buffer containing 50 mM sodium dodecylsulfate. Most favorable amperometric detection was obtained at +0.95 V. Linear calibration plots are observed for micromolar concentrations of the oxidizable amino acids. The new protocol offers good stability and for reproducibility, with relative S.D. of less than 5% for both migration times and peak currents (n=8). It should be useful for the analysis of aromatic amino acids, as desired for life sciences.  相似文献   

13.
In this work, we developed a novel molecularly imprinted solid‐phase microextraction with capillary electrophoresis method for the selective extraction and determination of protoberberines in complicated samples. The imprinted monolith was prepared in a micropipette tip‐based device by using acrylamide as the functional monomer, ethyleneglyoldimethacrylate as the cross‐linker and dimethylsulfoxide as the porogen, and exhibited an imprinting factor of 2.41 to berberine, 2.36 to palmatine and 2.38 to jatrorrhizine. Good capillary electrophoresis separation was achieved by using 20 mM phosphate buffer at pH 7 as running buffer with the addition of organic modifier of 10% methanol. Parameters such as sample pH value, sample flow rate and sample volume were investigated for imprinted monolith‐based solid‐phase microextraction. An imprinted solid‐phase microextraction with capillary electrophoresis method was developed, the method showed a wide linear range (0.3–50 μg/mL), good linearity (R2 ≥ 0.9947) and good reproducibility (relative standard deviations ≤ 0.73%), the limit of detection was as low as 0.1 μg/mL, which was lower than some reported methods based on capillary electrophoresis for protoberberines. The method has been applied for determination of three common protoberberines in Cortex Phellodendri Chinensis, by using a molecularly imprinted monolith as the selective sorbent, most of the matrices in the Cortex Phellodendri Chinensis sample were removed and three protoberberines were selectively enriched and well determined.  相似文献   

14.
This is an original report proposed a CE method for direct analysis of the underivatized amino acids using UV detection with relatively higher sensitivity, which was based on coordination interactions between amino acids and Cu (II) ions. In addition, an online sweeping preconcentration technique was easily combined to improve the detection sensitivity. Satisfying separations of the amino acids were obtained under optimized conditions: 50 mmol/L CuSO4–0.05% HAc–H2O (pH 4.5), and the separation voltage of 15 kV. The LODs for the analytes ranged from 0.1 to 0.5 μmol/L. The linearity of detection for all analytes was two orders of magnitude with the correlation coefficients greater than 0.99. The repeatability was displayed with an RSD less than 3% for migration time and peak height (n = 5). Moreover, some amino acids in real samples of human saliva and green tea were analyzed by this direct UV detection CE method with acceptable sensitivity.  相似文献   

15.
In order to improve the concentration sensitivity of capillary electrophoresis (CE), two sample preconcentration techniques, single drop microextraction (SDME) and large volume stacking using an electroosmotic flow pump (LVSEP), were coupled in-line in a commercial CE instrument. By simple programming of liquid handling sequences, a pentanol drop was prepared at the tip of a fused silica capillary over which a Teflon tube had been sleeved to serve as a hydrophobic support. After extraction of the analytes from an aqueous donor solution into the drop, the entire capillary column was filled with enriched pentanol extract. LVSEP, in which the sample matrix is automatically removed by the EOF, was then carried out using a methanolic run buffer. The overall enrichment factors for the analytes pentachlorophenol (PCP), 3-bromobenzoic acid (3-BBA), and 4-iodobenzoic acid (4-IBA), from a combination of 30 min SDME and LVSEP on a 27 cm capillary, were about 7000, even without agitation of the donor solution. The resulting limits of detection for PCP, 3-BBA, and 4-IBA were 0.7, 0.3 and 0.7 nM, respectively. Since no modification of the existing CE instrument is necessary and a bare capillary is used for LVSEP, this scheme can be adapted quite easily for many CE applications that require high concentration sensitivity.  相似文献   

16.
This study describes a method to determine nonsteroidal anti‐inflammatory drugs (NSAIDs) in urine samples based on the use of single‐drop microextraction (SDME) in a three‐phase design as a preconcentration technique coupled in‐line to capillary electrophoresis. Different parameters affecting the extraction efficiency of the SDME process were evaluated (e.g. type of extractant, volume of the microdroplet, and extraction time). The developed method was successfully applied to the analysis of human urine samples with LODs ranging between 1.0 and 2.5 μg/mL for all of the NSAIDs under study. This method shows RSD values ranging from 8.5 to 15.3% in interday analysis. The enrichment factors were calculated, resulting 27‐fold for ketoprofen, 14‐fold for diclofenac, 12‐fold for ibuprofen, and 44‐fold naproxen. Samples were analyzed applying the SDME–CE method and the obtained results presented satisfactory recovery values (82–115%). The overall method can be considered a promising approach for the analysis of NSAIDs in urine samples after minimal sample pretreatment.  相似文献   

17.
The combination of capillary electrophoresis (CE) and light-emitting diode-induced fluorescence (LED-IF) detection has been demonstrated in the analysis of major amino acids in tea leaves and beverages. The separation efficiency of amino acids, which were derivatized with naphthalene-2,3-dicarboxaldehyde (NDA), depended on the capillary length and PEO concentration. We suggested that the interactions between the NDA derivatives and poly(ethylene oxide) (PEO) molecules are based on hydrogen bonding, hydrophobic patches, and Van der Waals forces. The magnitude of EOF and the interactions between them can be further controlled by the capillary length. The separation of 17 NDA-amino acids derivatives was completed within 16 min using 0.5% PEO and 60 cm capillary length. The relative standard deviations (R.S.D.) of their migration times (n = 5) were less than 2.7%. Additionally, the limits of detection at signal-to-noise ratio 3 for the tested amino acids ranged from 3.6 to 28.3 nM. Quantitative determination of amino acids in tea leaves and beverages was accomplished by our proposed method. This study showed that amino acid present in highest concentration in tea leaves and beverages is γ-aminobutyric acid and theanine, respectively. The experimental results suggest that our proposed methods have great potential in the investigation of the biofunction of different tea samples.  相似文献   

18.
A sensitive capillary electrophoretic separation method with contactless conductivity detection (C4D) for analysis of five priority haloacetic acids (HAA5) is presented. The analytes were baseline separated in an electrolyte composed of 20 mM 2-(N-Morpholino) ethanesulfonic acid (MES), 20 mM L-histidine (HIS), and 30 μM cetyltrimethylammonium bromide (CTAB) at pH 6.0 in less than 4 min. A simplified solid-phase extraction (SPE) preconcentration procedure on highly cross-linked polystyrene-divinylbenzene (PS-DVB) type sorbent was developed and optimized with respect to short preconcentration time. HAA5 from a 25-mL sample aliquot of tap and swimming pool water could be preconcentrated in less than 5 min using an in-house made SPE column with recoveries ranging from 23 to 98%. Combining the SPE preconcentration procedure with capillary electrophoretic analysis, the attained limits of detection were between 6.1 and 12.2 μg/L with total analysis time of less than 10 min.  相似文献   

19.
毛细管电泳-间接紫外检测法测定蜂蜜中的氨基酸   总被引:2,自引:0,他引:2  
周贤婧  师彦平 《色谱》2013,31(7):661-666
采用毛细管电泳-间接紫外检测法同时分离测定蜂蜜中的赖氨酸、色氨酸、谷氨酸等9种氨基酸。考察了磷酸浓度、进样方式和缓冲液pH对分离效率和重现性的影响。在分离电压为-15 kV、检测波长为220 nm条件下,以含有0.5 mmol/L十六烷基三甲基溴化铵、20 mmol/L烟酸、10%甲醇的10 mmol/L磷酸二氢钠缓冲溶液(pH 10.2)为运行缓冲液,9种组分在11 min内达到基线分离;检出限最低可达到0.3 mg/L;线性范围为1.0~1000 mg/L;日间及日内精密度为0.64%~5.83%。实际样品中除甲硫氨酸外的8种氨基酸的加标回收率为60.00%~118.37%。将该方法应用于不同蜜源植物和产地的蜂蜜样品的测定,在市售的5种蜂蜜中均检测到脯氨酸、丝氨酸和天冬氨酸,而只在荔枝蜜中检测到苏氨酸。该方法可以为蜂蜜的蜜源鉴别及质量评估提供借鉴方法。  相似文献   

20.
An improved automated continuous sample introduction system for microfluidic capillary electrophoresis (CE) is described. A sample plate was designed into gear-shaped and was fixed onto the shaft of a step motor. Twenty slotted reservoirs for containing samples and working electrolytes were fabricated on the “gear tooth” of the plate. A single 7.5-cm long Teflon AF-coated silica capillary serves as separation channel, sampling probe, as well as liquid-core waveguide (LCW) for light transmission. Platinum layer deposited on the capillary tip serves as the electrode. Automated continuous sample introduction was achieved by scanning the capillary tip through the slots of reservoirs. The sample was introduced into capillary and separated immediately in the capillary with only about 2-nL gross sample consumption. The laser-induced fluorescence (LIF) method with LCW technique was used for detecting fluorescein isothiocyanate (FITC)-labeled amino acids. With electric-field strength of 320 V/cm for injection and separation, and 1.0-s sample injection time, a mixture of FITC-labeled arginine and leucine was separated with a throughput of 60/h and a carryover of 2.7%.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号