首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Ma Q  Yu Q  Luo Y  Feng Y 《色谱》2011,29(7):624-630
将聚(甲基丙烯酸-乙二醇二甲基丙烯酸酯) (poly(MAA-co-EDMA))聚合物原位聚合于玻璃内插管外表面上,得到一种多孔聚合物涂层;将其作为搅拌棒吸附萃取的萃取介质,考察了其对磺胺类药物的萃取性能;最后将其与高效液相色谱-电喷雾质谱(HPLC-ESI-MS)联用,建立了一种牛奶中4种磺胺类药物的检测方法。在最佳条件下,牛奶中4种磺胺类药物的检出限(S/N=3)和定量限(S/N=10)分别为0.11~0.52 μg/L和0.35~1.72 μg/L。在1~500 μg/L的范围内峰面积与质量浓度具有良好的线性关系,日内、日间测定的相对标准偏差不高于11.3%。结果表明,该方法简便、灵敏度高且成本低,适合于牛奶中磺胺类药物的检测。  相似文献   

2.
In this study, a novel stir bar sorptive extraction (SBSE) based on monolithic material (SBSEM) was prepared. The monolithic material was obtained by in situ copolymerization of vinylpyrrolidone and divinylbenzene in the presence of a porogen solvent containing cyclohexanol and 1-dodecanol with azobisisobutyronitrile as initiator. The influences of polymerization conditions on the extraction efficiencies were investigated, using phenol and p-nitrophenol as detected solutes. The monolithic material was characterized by various techniques, such as elemental analysis, scanning electron microscopy, mercury intrusion porosimetry, infrared spectroscopy. Polycyclic aromatic hydrocarbons were used to investigate the extraction efficiencies of SBSEM for apolar analytes. Hormones, aromatic amines and phenols were selected as test analytes to investigate the extraction efficiencies of SBSEM for weakly and strongly polar compounds. The results showed that the new SBSEM could enrich the above-mentioned organic compounds effectively. It is worthy to mention that the SBSEM can enrich some heavy metal ions, such as Cu2+, Pb2+, Cr3+ and Cd2+, through coordination adsorption. To our best knowledge, that is the first to use SBSE to enrich heavy metal ions.  相似文献   

3.
A novel anionic exchange stir bar sorptive extraction (SBSE) coating based on poly(2-(methacryloyloxy)ethyltrimethylammonium chloride-co-divinylbenzene) monolithic material for the extraction of inorganic anion was prepared. The effect of preparation conditions such as ratio of functional monomer to cross-linker, content of porogenic solvent on the extraction efficiencies were investigated in detailed. The monolithic material was characterized by elemental analysis, scanning electron microscopy and infrared spectroscopy. In order to investigate the extraction capacity of the new coating for inorganic anion, the new SBSE was combined with ionic chromatography with conductivity detection, Br, NO3, PO43− and SO42− were selected as detected solutes. Several extractive parameters, including pH value and ionic strength in sample matrix, desorption solvent, extraction and desorption time were optimized. The results showed that strongly ionic strength did not favor the extraction of anlaytes. Under the optimum experimental conditions, low detection limits (S/N = 3) and quantification limits (S/N = 10) of the proposed method for the target anions were achieved within the range of 0.92–2.62 and 3.03–9.25 μg/L, respectively. The method also showed good linearity, simplicity, practicality and low cost for the extraction inorganic anions. Finally, the proposed method was successfully used to detect the two different trademarks of commercial purified water with satisfactory recovery in the range of 70.0–92.6%. To the best of our knowledge, this is the first to use SBSE to enrich inorganic anions.  相似文献   

4.
A simple and sensitive method for the determination of polar aromatic amines (PAAs) was developed using stir bar sorptive extraction (SBSE) coupling to high-performance liquid chromatography. A hydrophilic poly(vinylimidazole-divinylbenzene) (VIDB) monolithic material was prepared and acted as SBSE coating. The influences of polymerization conditions for VIDB on the extraction efficiency were investigated using aniline and 2,4-dinitroaniline as detected solutes. To achieve optimum extraction performance for PAAs, several parameters including extraction and desorption time, desorption solvent, ionic strength and pH value of sample matrix were investigated. The results showed that under the optimized experimental conditions, the method showed good sensitivity and excellent recoveries, as well as advantages such as linearity, simplicity, low cost and high feasibility. The extraction performance of present method to the target compounds also compared with commercial SBSE which using polydimethylsiloxane as coating and other SBSE which based on monolithic materials. Finally, the proposed method was successfully applied to the determination of PAAs in lake and sea waters, and excellent recoveries of spiked target compounds in real samples were obtained.  相似文献   

5.
A stir bar microextraction (SBSE) procedure for the determination of seven strobilurin fungicides in fruit samples using liquid chromatography (LC) and diode array detection (DAD) has been developed. The samples were sonicated in the presence of ethanol before submitting the extracts to SBSE. The incorporation of drazoxolon as an internal standard before SBSE allowed calibration without the need to use the standard additions method. Under the optimized conditions, detection limits were in the 0.3–2 ng g−1 range, corresponding to trifloxystrobin and metominostrobin, respectively. The SBSE–LC–DAD procedure showed good repeatability (RSD below 11% in all cases) and provided recoveries of 80–105% from spiked samples. The method was applied to fifteen fruit samples, and low levels of pyraclostrobin and trifloxystrobin were found in two of them.  相似文献   

6.
In the present study, a stir bar coated with hydrophilic polymer based on poly(N-vinylpyrrolidone-co-divinylbenzene) was prepared for the sorptive extraction of polar compounds. The main parameters affecting the polymerisation of the coating were investigated.The new stir bar was applied successfully in stir bar sorptive extraction with liquid desorption followed by liquid chromatography–mass spectrometry in tandem with a triple quadrupole for the determination of a group of polar pharmaceuticals and personal care products (PPCPs) in environmental water matrices. Different variables affecting extraction and desorption such as agitation speed, temperature, ionic strength and extraction time were optimised. The results showed that the stir bar is able to enrich the selected analytes effectively.The developed method was applied to determine a group of PPCPs in different complex environmental samples, including river, effluent and influent waste water.  相似文献   

7.
A simple, rapid, and sensitive method for the quantitative monitoring of five sulfonamide antibacterial residues (SAs) in milk was developed by stir bar sorptive extraction (SBSE) coupling to high performance liquid chromatography with diode array detection. The analytes were concentrated by SBSE based on poly (vinylimidazole–divinylbenzene) monolithic material as coating. The extraction procedure was very simple, milk was diluted with water then directly sorptive extraction without elimination of fats and protein in samples was required. To achieve optimum extraction performance for SAs, several parameters, including extraction and desorption time, desorption solvent, ionic strength and pH value of sample matrix were investigated. Under the optimized experimental conditions, low detection limits (S/N = 3) quantification limits (S/N = 10) of the proposed method for the target compounds were achieved within the range of 1.30–7.90 ng/mL and 4.29–26.3 ng/mL from spiked milk, respectively. Good linearities were obtained for SAs with the correlation coefficients (R2) above 0.996. Finally, the proposed method was successfully applied to the determination of SAs compounds in different milk samples and satisfied recoveries of spiked target compounds in real samples were obtained.  相似文献   

8.
农舒予  林福华  黄晓佳  袁东星 《色谱》2012,30(11):1133-1142
以己烯雌酚为替代模板,利用整体材料的“原位”合成技术制备了分子印迹聚合物,并将其作为固相萃取搅拌棒的涂层(MIP-SBSE)制备了新的搅拌棒。详细考察了分子印迹聚合物制备条件中模板分子及功能单体用量对MIP-SBSE选择性萃取性能的影响,同时利用元素分析、扫描电镜和红外光谱对聚合物进行表征。以双烯雌酚(DS)和己烷雌酚(HS)为目标化合物,将MIP-SBSE与高效液相色谱-二极管阵列检测器联用,建立起复杂样品中DS和HS的分离分析方法。考察了吸附和解吸时间、解吸溶剂、离子强度和样品pH值等萃取条件对MIP-SBSE选择性萃取性能的影响。结果表明,在最佳萃取条件下,MIP-SBSE对DS和HS具有较高的选择性萃取性能,线性范围分别为1.0~400.0 μg/L和5.0~400.0 μg/L,利用氮吹再定容的方法,对DS和HS的检出限(S/N=3)分别可低至0.04和0.14 μg/L。在对实际污水、蜂蜜和牛尿样品的分析中取得了良好的加标回收率,其值为61.3%~120%。所建方法具有简便、高选择性和灵敏等特点,可用于复杂样品中双烯雌酚和己烷雌酚的分析监测。  相似文献   

9.
An optimised method using stir bar sorptive extraction (SBSE) and a thermal desorption‐GC‐electron capture detector (GC‐ECD) for the determination of short‐chain chlorinated paraffins from water samples was developed. Recoveries near to 100% were obtained by using 20 mm×0.5 mm (length×film thickness) PDMS commercial stir bars from 200 mL spiked water samples and 20% methanol addition with an extraction period of 24 h. Method sensitivity, linearity and precision were evaluated for surface water and wastewater spiked samples. A LOD of 0.03 and 0.04 μg/L was calculated for surface and wastewater, respectively. The precision of the method given as an RSD was below 20% for both matrices. The developed method was applied for the analysis of two real samples from a contaminated river and a wastewater treatment plant. Results were in accordance with those obtained using a previously developed method based on solid phase microextraction (SPME).  相似文献   

10.
A method for the trace analysis of methylmercury (MeHg) and Hg(II) in water sample was developed, which involved stir bar sorptive extraction (SBSE) with in situ alkylation with sodium tetraethylborate and thermal desorption (TD)-gas chromatography-mass spectrometry (GC-MS). The limits of quantification of MeHg and Hg(II) are 20 and 10 ng L−1 (Hg), respectively. The method shows good linearity and the correlation coefficients are higher than 0.999. The average recoveries of MeHg and Hg(II) in tap or river water sample are 102.1-104.3% (R.S.D.: 7.0-8.9%) and 105.3-106.2% (R.S.D.: 7.4-8.5%), respectively. This simple, accurate, sensitive, and selective analytical method may be used in the determination of trace amounts of MeHg and Hg(II) in tap and river water samples.  相似文献   

11.
An effective and simple method for polar phenols in water matrix was developed by using stir bar sorptive extraction (SBSE) based on a hydrophilic poly(vinylpyrrolididone‐divinylbenzene) (VPDB) monolithic material and HPLC analysis. To achieve optimum extraction performance for phenols, several parameters, including extraction and desorption time, desorption solvent, pH value, and ionic strength of sample matrix, were investigated. Under the optimized experimental conditions, eight phenols were directly enriched from water samples and analyzed by HPLC‐DAD. The detection limits (S/N = 3) and quantification limits (S/N = 10) of the proposed method for the target compounds were achieved within the range of 0.72–1.37 and 2.40–4.27 ng/mL from spiked water, respectively. Recoveries of eight phenolic compounds were found in the range of 55.2–95.9%. The calibration curves showed the linearity ranging from 5 to 150 ng/mL with linear regression coefficient R2 values above 0.98. Method repeatability presented as intra‐ and interday precisions were also found with the RSDs less than 4.10 and 7.61%, respectively. The distribution coefficients between VPDB and water (KVPDB/W) for phenolic compounds were also calculated and compared with KO/W. Finally, the proposed method was successfully applied to the determination of the target compounds in tap water, sea water and wastewater samples.  相似文献   

12.
In the present study, a convenient and sensitive method for determination of six penicillin antibiotics (amoxicillin, ampicillin, penicillin G, oxacillin, cloxacillin, and dicloxacillin) in milk and honey samples was developed. Milk and honey samples were diluted with water, then directly treated by stir bar sorptive extraction based on poly (vinylimidazole‐divinylbenzene) monolithic material as coating. The analytes were analyzed by LC/ESI‐ MS/MS. Several extraction parameters including extraction and desorption time, pH value, and ionic strength in sample matrix were investigated in detail. Under the optimized extraction conditions, the calculated detection limits for the target compounds were as low as 0.23–2.66 ng/kg in milk and 0.18–1.42 ng/kg in honey, respectively. Good linearity was obtained for analytes with the correlation coefficients (R2) above 0.997. Excellent method reproducibility was achieved in terms of intraday and interday precisions, indicated by the RSDs of <5.0 and <10.0%, respectively. Finally, the proposed method was successfully applied to the determination of penicillin antibiotics residues in different milk and honey samples.  相似文献   

13.
In this article, a novel polydimethylsiloxane/activated carbon (PDMS‐ACB) material is proposed as a new polymeric phase for stir bar sorptive extraction (SBSE). The PDMS‐ACB stir bar, assembled using a simple Teflon®/glass capillary mold, demonstrated remarkable stability and resistance to organic solvents for more than 150 extractions. The SBSE bar has a diameter of 2.36 mm and a length of 2.2 cm and is prepared to contain 92 μL of polymer coating. This new PDMS‐ACB bar was evaluated for its ability to determine the quantity of pesticides in sugarcane juice samples by performing liquid desorption (LD) in 200 μL of ethyl acetate and analyzing the solvent through gas chromatography coupled with mass spectrometry (GC‐MS). A fractional factorial design was used to evaluate the main parameters involved in the extraction procedure. Then, a central composite design with a star configuration was used to optimize the significant extraction parameters. The method used demonstrated a limit of quantification (LOQ) of 0.5–40 μg/L, depending on the analyte detected; the amount of recovery varied from 0.18 to 49.50%, and the intraday precision ranged from 0.072 to 8.40%. The method was used in the analysis of real sugarcane juice samples commercially available in local markets.  相似文献   

14.
A new method, stir bar sorptive extraction (SBSE) with in situ derivatization and thermal desorption (TD)-gas chromatography-mass spectrometry (GC-MS), which is used for the determination of trace amounts of chlorophenols, such as 2,4-dichlorophenol (2,4-DCP), 2,4,6-trichlorophenol (2,4,6-TrCP), 2,3,4,6-tetrachlorophenol (2,3,4,6-TeCP) and pentachlorophenol (PCP), in tap water, river water and human urine samples, is described. The derivatization conditions with acetic acid anhydride and the SBSE conditions such as extraction time are investigated. Then, the stir bar is subjected to TD followed by GC-MS. The detection limits of the chlorophenols in tap water, river water and human urine samples are 1-2, 1-2, and 10-20 pg ml−1 (ppt), respectively. The calibration curves for the chlorophenols are linear and have correlation coefficients higher than 0.99. The average recoveries of the chlorophenols in all the samples are higher than 95% (R.S.D. < 10%) with correction using added surrogate standards, 2,4-dichlorophenol-d5, 2,4,6-trichlorophenol-13C6, 2,3,4,6-tetrachlorophenol-13C6 and pentachlorophenol-13C6. This simple, accurate, sensitive and selective analytical method may be applicable to the determination of trace amounts of chlorophenols in liquid samples.  相似文献   

15.
In this study, a simple and rapid method was developed for the determination of seven steroid hormones in wastewater. Sample preparation and analysis were performed by stir bar sorptive extraction (SBSE) based on poly(vinylpyridine-ethylene dimethacrylate) monolithic material (SBSEM) combined with high-performance liquid chromatography with diode array detection. To achieve the optimum extraction performance, several main parameters, including extraction and desorption time, pH value and contents of inorganic salt in the sample matrix, were investigated. Under the optimized experimental conditions, the method showed good linearity and repeatability, as well as advantages such as sensitivity, simplicity, low cost and high feasibility. The extraction performance of SBSEM to the target compounds also compared with commercial SBSE which used polydimethylsiloxane as coating. Finally, the proposed method was successfully applied to the determination of the target compounds in wastewater samples. The recoveries of spiked target compounds in real samples ranged from 48.2% to 110%.  相似文献   

16.
In this study, a new stir bar sorptive extraction (SBSE) coating based on poly(vinylphthalimide-co-N,N'-methylenebisacrylamide) monolith (SBSE-VPMB) was prepared. The influences of the contents of monomer in polymerization mixture and the percentage of porogen solvent on the extraction performance were investigated thoroughly. Several characteristic techniques, such as elemental analysis, scanning electron microscopy, mercury intrusion porosimetry and infrared spectroscopy, were used to characterize the monolithic material. The analysis of oxfendazole (OFZ) and mebendazole (MBZ) in milk and honey samples by the combination of SBSE with HPLC with diode array detection was selected as paradigms for the practical evaluation of the new coating. Under the optimized extraction conditions, the limits of detection (S/N=3) for OFZ and MBZ were 0.23-0.60 μg/L in milk and 0.24-1.08 μg/L in honey, respectively. The method also showed good linearity, repeatability, high feasibility and acceptable recoveries for real samples. At the same time, the extraction performance and the distribution coefficients (K(VPMB/W)) of OFZ and MBZ on SBSE-VPMB were compared with other SBSEs based on porous monoliths and commercial SBSE.  相似文献   

17.
Xu Z  Song C  Hu Y  Li G 《Talanta》2011,85(1):97-103
A novel sulfamethazine molecularly imprinted polymer (MIP)-coated stir bar for sorptive extraction of eight sulfa drugs from biological samples was prepared. The MIP-coating was about 20 μm thickness with the relative standard deviation (RSD) of 6.7% (n = 10). It was characterized by scanning electron microscope, infrared spectrum, thermogravimetric analysis, and solvent-resistant investigation, respectively. The non-imprinted polymer (NIP)-coating was used for comparison. The adsorptive capacity and selectivity of MIP-coating were evaluated in detail. The MIP-coating showed higher adsorption capability and selectivity than the NIP-coating. The saturated adsorption amount of the MIP-coating was 4.6 times over that of the NIP-coating in toluene. Sulfamethazine could be detected after the MIP-coated stir bar sorptive extraction even at a low concentration of 0.2 μg/L. The MIP-coating also exhibited selective adsorption ability to analogues of the template. A method for the determination of eight sulfa drugs in biological samples by MIP coated stir bar sorptive extraction coupled with high performance liquid chromatography (HPLC) was developed. The extraction conditions, including extraction solvent, extraction time, desorption solvent, desorption time and stirring speed, were optimized. The linear ranges were 1.0-100 μg/L and 2.0-100 μg/L for eight sulfonamides, respectively. The detection limits were within the range of 0.20-0.72 μg/L. The method was successfully applied to simultaneous multi-residue analysis of eight sulfonamides in spiked pork, liver and chicken samples with the satisfactory recoveries.  相似文献   

18.
In this work, we proposed a simple co-mixing method to fabricate magnetic one-dimensional polyaniline (denoted as 1D-PANIs/MNPs). One-dimensional polyanilines (1D-PANIs) and magnetic nanoparticles (MNPs) were prepared by chemical oxidation and solvothermal methods, respectively. When MNPs and 1D-PANIs (with mass ratio 4:1) were co-mixed and vortexed evenly in a solvent (e.g., ethanol, water, acetonitrile), they could assemble into 1D-PANIs/MNPs spontaneously and thus be magnetically separable. To testify the feasibility of 1D-PANIs/MNPs in sample preparation, it was applied as the sorbent for magnetic solid phase extraction (MSPE) of fluoroquinolones (FQs) in honey samples. Under optimized conditions, a rapid, convenient, and efficient method for the determination of four FQs in honey samples by 1D-PANIs/MNPs-based MSPE coupling with high performance liquid chromatography with fluorescence detection (HPLC-FLD) was established. The limits of detection (LODs) for four FQs ranged from 0.4 to 1.4 ng g−1. The intra- and interday relative standard deviations (RSDs) were less than 17.6%. The recoveries of FQs for three spiked honey samples ranged from 86.3 to 121.3%, with RSDs of less than 16.3%.  相似文献   

19.
A method for the determination of ultra-trace amounts of organochlorine pesticides (OCPs) in river water was developed by using stir bar sorptive extraction (SBSE) followed by thermal desorption and comprehensive two-dimensional gas chromatography coupled to high-resolution time-of-flight mass spectrometry (SBSE-TD-GC×GC-HRTOF-MS). SBSE conditions such as extraction time profiles, phase ratio (β: sample volume/polydimethylsiloxane (PDMS) volume), and modifier addition, were examined. Fifty milli-liter sample including 10% acetone was extracted for 3 h using stir bars with a length of 20 mm and coated with a 0.5 mm layer of PDMS (PDMS volume, 47 μL). The stir bar was thermally desorbed and subsequently analyzed by GC×GC-HRTOF-MS. The method showed good linearity over the concentration range from 50 to 1000 pg L(-1) or 2000 pg L(-1) for all analytes, and the correlation coefficients (r(2)) were greater than 0.9903 (except for β-HCH, r(2)=0.9870). The limit of detection (LOD) ranged from 10 to 44 pg L(-1). The method was successfully applied to the determination of 16 OCPs at pg L(-1) to ng L(-1) in river water. The results agree fairly well with the values obtained by a conventional liquid-liquid extraction (LLE)-GC-HRMS (selected ion monitoring: SIM) method using large sample volume (20 L). The method also allows screening of non-target compounds, e.g. pesticides and their degradation products, polyaromatic hydrocarbons (PAHs), polychlorinated biphenyls (PCBs), and pharmaceuticals and personal care products (PPCPs) and metabolites in the same river water sample, by using full spectrum acquisition with accurate mass in GC×GC.  相似文献   

20.
A novel method called thermal desorption (TD) with in tube silylation followed by gas chromatography-mass spectrometry (GC-MS), which is used for the determination of trace amounts of alkylphenols (APs) in river water samples, is described. APs are extracted from river water samples and concentrated by the stir bar sorptive extraction (SBSE) technique. The stir bar coated with polydimethylsiloxane (PDMS) is added to 2.0 ml water sample and stirring is carried out for 60 min at room temperature (25 degrees C) in the vial. Then, the PDMS stir bar is subjected to TD with in tube silylation followed by GC-MS. The detection limit is of the sub pg ml(-1) (ppt) level. The method shows good linearity and the correlation coefficients are higher than 0.99 for all analytes. The average recoveries of APs are higher than 90% (R.S.D.: 3.6-14.8%, n=6). This simple and sensitive analytical method may be used in the determination of trace amounts of APs in river water samples.  相似文献   