首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 625 毫秒
1.
We report a method, based on the principles of origami (paper folding), for fabricating three-dimensional (3-D) paper microfluidic devices. The entire 3-D device is fabricated on a single sheet of flat paper in a single photolithographic step. It is assembled by simply folding the paper by hand. Following analysis, the device can be unfolded to reveal each layer. The applicability of the device to chemical analysis is demonstrated by colorimetric and fluorescence assays using multilayer microfluidic networks.  相似文献   

2.
A microfluidic paper-based analytical device (μPAD) for the separation of blood plasma from whole blood is described. The device can separate plasma from whole blood and quantify plasma proteins in a single step. The μPAD was fabricated using the wax dipping method, and the final device was composed of a blood separation membrane combined with patterned Whatman No.1 paper. Blood separation membranes, LF1, MF1, VF1 and VF2 were tested for blood separation on the μPAD. The LF1 membrane was found to be the most suitable for blood separations when fabricating the μPAD by wax dipping. For blood separation, the blood cells (both red and white) were trapped on blood separation membrane allowing pure plasma to flow to the detection zone by capillary force. The LF1-μPAD was shown to be functional with human whole blood of 24-55% hematocrit without dilution, and effectively separated blood cells from plasma within 2 min when blood volumes of between 15-22 μL were added to the device. Microscopy was used to confirm that the device isolated plasma with high purity with no blood cells or cell hemolysis in the detection zone. The efficiency of blood separation on the μPAD was studied by plasma protein detection using the bromocresol green (BCG) colorimetric assay. The results revealed that protein detection on the μPAD was not significantly different from the conventional method (p > 0.05, pair t-test). The colorimetric measurement reproducibility on the μPAD was 2.62% (n = 10) and 5.84% (n = 30) for within-day and between day precision, respectively. Our proposed blood separation on μPAD has the potential for reducing turnaround time, sample volume, sample preparation and detection processes for clinical diagnosis and point-of care testing.  相似文献   

3.
Sutarlie L  Yang KL 《Lab on a chip》2011,11(23):4093-4098
Monitoring spatial distribution of chemicals in microfluidic devices by using traditional sensors is a challenging task. In this paper, we report utilization of a thin layer of cholesteric liquid crystal for monitoring ethanol inside microfluidic channels. This thin layer can be either a polymer dispersed cholesteric liquid crystal (PDCLC) layer or a free cholesteric liquid crystal (CLC) layer separated from the microfluidic device by using a thin film of PDMS. They both show visible colorimetric responses to 4% of ethanol solution inside the microfluidic channels. Moreover, the spatial distribution of ethanol inside the microfluidic channel can be reflected as a color map on the CLC sensing layers. By using this device, we successfully detected ethanol produced from fermentation taking place inside the microfluidic channel. These microfluidic channels with embedded PDCLC or embedded CLC offer a new sensing solution for monitoring volatile organic compounds in microfluidic devices.  相似文献   

4.
In this paper, we describe a microfluidic device in which solutions with stepwise concentrations can be accurately generated by continuously introducing two kinds of miscible liquids from each inlet, and biochemical processing can be conducted at the various conditions. Introduced liquid flows are geometrically divided into a number of downstream flows through multiple distribution channels, and each divided flow is then mixed with the divided flow of another liquid at a confluent point. The lengths of the precisely designed distribution channels determine the mixing ratio of the two liquids, without the influence of flow rate. In this study, a PDMS microfluidic device able to generate nine different concentrations was fabricated, and the performance of this device was estimated via colorimetric assay. As a biological application of this device, cell cultivation was performed under different concentration conditions. Due to its simplicity of operation, this microfluidic flow distributor will be applied to various kinds of biological analysis and screening systems.  相似文献   

5.
《Electrophoresis》2018,39(12):1443-1451
This paper describes the fabrication of and data collection from two microfluidic devices: a microfluidic thread/paper based analytical device (μTPAD) and 3D microfluidic paper‐based analytical device (μPAD). Flowing solutions of glucose oxidase (GOx), horseradish peroxidase (HRP), and potassium iodide (KI), through each device, on contact with glucose, generated a calibration curve for each platform. The resultant yellow‐brown color from the reaction indicates oxidation of iodide to iodine. The devices were dried, scanned, and analyzed yielding a correlation between yellow intensity and glucose concentration. A similar procedure, using an unknown concentration of glucose in artificial urine, is conducted and compared to the calibration curve to obtain the unknown value. Studies to quantify glucose in artificial urine showed good correlation between the theoretical and actual concentrations, as percent differences were ≤13.0%. An ANN was trained on the four‐channel CMYK color data from 54 μTPAD and 160 μPAD analysis sites and Pearson correlation coefficients of R = 0.96491 and 0.9739, respectively, were obtained. The ANN was able to correctly classify 94.4% (51 of 54 samples) and 91.2% (146 of 160 samples) of the μTPAD and μPAD analysis sites, respectively. The development of this technology combined with ANN should further facilitate the use of these platforms for colorimetric analysis of other analytes.  相似文献   

6.
采用具有紫外光聚合性能的聚乙二醇(PEG)基水凝胶材料, 通过紫外光聚合作用快速加工双层水凝胶微流控芯片, 并验证了其对肿瘤细胞代谢液进行检测的可行性. 与传统微流控芯片材料相比, 该水凝胶芯片材料具有更好的生物相容性及可操控性, 可直接加工成形, 在生物学领域特别是细胞培养过程控制方面具有良好的应用前景. 实验结果表明, 该水凝胶微流控芯片可在微尺度空间有效模拟细胞生长环境, 并实现对细胞连续捕获后的原位培养. 将该芯片与卟啉可视阵列传感器系统结合, 经代谢特征分析可有效区分不同种类肿瘤细胞, 实现芯片细胞培养平台上的细胞代谢指纹快速可视化传感检测.  相似文献   

7.
Paper-based microfluidic devices have been widely investigated in recent years. Among various detection techniques, colorimetric method plays a very important role in paper-based microfluidic devices. The limitation, however, is also clear: they generally require highly sensitive indicators. In this work, we have developed a novel enrichment-based paper test for the discrimination of heavy-metal ions. Comparing to regular paper-based microfluidic devices, enrichment-based technique showed largely improved sensitivity. Combining with eight pyridylazo compounds and array technologies-based pattern-recognition, we have obtained the discrimination capability of eight different heavy-metal ions at same concentration as low as 50 μM using our enrichment-based pyridylazo compounds array paper. Identification of the heavy-metal ions was readily achieved using a standard chemometric approach. This method can be, of course, used for other analytes as well.  相似文献   

8.
《Electrophoresis》2018,39(7):957-964
Proteinuria is an established risk marker for progressive renal function loss and patients would significantly benefit from a point‐of‐care testing. Although extensive work has been done to develop the microfluidic devices for the detection of urinary protein, they need the complicated operation and bulky peripherals. Here, we present a rapid, maskless 3D prototyping for fabrication of capillary fluidic circuits using laser engraving. The capillary circuits can be fabricated in a short amount of time (<10 min) without the requirements of clean‐room facilities and photomasks. The advanced capillary components (e.g., trigger valves, retention valves and retention bursting valves) were fabricated, enabling the sequential liquid delivery and sample‐reagent mixing. With the integration of smartphone‐based detection platform, the microfluidic device can quantify the urinary protein via a colorimetric analysis. By eliminating the bulky and expensive equipment, this smartphone‐based detection platform is portable for on‐site quantitative detection.  相似文献   

9.
In this paper we describe the fabrication of novel 3D microfluidic paper‐based analytical devices (3D‐μPADs) and a 3D microfluidic thread/paper‐based analytical device (3D‐μTPAD) to detect glucose and BSA through colorimetric assays. The 3D‐μPAD and 3D‐μTPAD consisted of three (wax, heat pressed wax‐printed paper, single‐sided tape) and four (hole‐punched single‐sided tape, blank chromatography circles, heat‐pressed wax‐printed paper, hole‐punched single‐sided tape containing trifurcated thread) layers, respectively. The saturation curves for each assay were generated for all platforms. For the glucose assay, a solution of glucose oxidase (GOx), horseradish peroxidase, and potassium iodide was flowed through each platform and, upon contact with glucose, generated a yellow‐brown color indicative of the oxidation of iodide to iodine. For the protein assay, BSA was flowed through each device and, upon contact with citrate buffer and tetrabromophenol blue, resulted in a color change from yellow to blue. The devices were dried, scanned, and analyzed yielding a correlation between either yellow intensity and glucose concentration or cyan intensity and BSA concentration. A similar glucose assay, using unknown concentrations of glucose in artificial urine, was conducted and, when compared to the saturation curve, showed good correlation between the theoretical and actual concentrations (percent differences <10%). The development of 3D‐μPADs and 3D‐μTPADs can further facilitate the use of these platforms for colorimetric bioassays.  相似文献   

10.
Genotyping from saliva with a one-step microdevice   总被引:1,自引:0,他引:1  
Pjescic I  Crews N 《Lab on a chip》2012,12(14):2514-2519
This paper presents a disposable microfluidic device for on-chip lysing, PCR, and analysis in one continuous-flow process. Male-female sex determination was performed with human saliva in less than 20 min from spit to finish, and requiring only seconds of manual sample handling. This genetic analysis was based on the amplification and detection of the DYZ1 repeat region unique to the Y-chromosome. The flow-through microfluidic chip consisted of a single serpentine channel designed to guide samples through 42 heating and cooling cycles. Cycling was performed by matching the local channel geometry to a steady-state temperature gradient established across the microfluidic chip. 38 channel segments were designed for rapid low volume PCR, and four were optimized for spatial DNA melting analysis. Fluorescence detection was used to monitor the amplification and to capture the melting signature of the amplicon was performed with a basic 8-bit CCD camera. The microfluidic device itself was fabricated from microscope slides and a double-sided tape. The simplicity of the system and its robust performance combine in an elegant solution for lab-on-a-chip genetic analysis.  相似文献   

11.
A surface plasmon resonance (SPR) sensor on a compact disk (CD)-type microfluidic device was developed to miniaturize the elements of a complete analytical system, pump and valves. The CD-type microfluidic device was fabricated by attaching a polydimethylsiloxane disk plate that contained microchannels and reservoirs to a flat polycarbonate disk plate that contained grating films with a thin layer of Au. The optical system of the SPR sensor and the theory for its operation are based on the principle of a grating coupled-type SPR. The sample and reagent solutions in the reservoirs on the CD-type microfluidic device were sequentially introduced into the detection chamber by centrifugal force generated by the rotation of the microfluidic device. The variation of resonance wavelength was dependent on the refractive index of the sample solution. This CD-type SPR sensor was successfully used in an immunoassay of immunoglobulin A (IgA). The anti-IgA, blocking reagent, sample and washing solution in the reservoirs were sequentially introduced into the detection chamber by changing the frequency of rotation of the microfluidic device. IgA in the sample solution was adsorbed to the anti-IgA immobilized on the Au thin layer in the detection chamber and was then detected by the SPR sensor.  相似文献   

12.
The development of novel and reliable technologies for the analysis of proteins and their post-translational modifications, in particular, has recently received much attention and interest. The implementation of a fully integrated microfluidic device interfaced with MS detection for the analysis of phosphoproteins is presented in this paper. The microfluidic platform (3'x1.5') comprises two individual sample processing systems: one for performing direct sample infusion and one for performing microfluidic LC separations. Various MS detection strategies, specific for the study of post-translational modifications, were conducted using alpha-casein as a model protein. Neutral loss ion mapping, data-dependent triple-play and neutral loss analysis, and in situ dephosphorylation followed by LC separation and MS detection were performed. Consistent results in identifying phosphopeptides with conventional and microfluidic instrumentation have been obtained. Unlike with conventional instrumentation, however, the microfluidic device enabled the completion of each analysis from only a few microliters of sample, in approximately 10-15 min, and on a bioanalytical platform that facilitates multiplexing and disposability, and thus high-throughput, contamination-free analysis.  相似文献   

13.
Novo P  Prazeres DM  Chu V  Conde JP 《Lab on a chip》2011,11(23):4063-4071
Microfluidic technology has the potential to decrease the time of analysis and the quantity of sample and reactants required in immunoassays, together with the potential of achieving high sensitivity, multiplexing, and portability. A lab-on-a-chip system was developed and optimized using optical and fluorescence microscopy. Primary antibodies are adsorbed onto the walls of a PDMS-based microchannel via microspotting. This probe antibody is then recognised using secondary FITC or HRP labelled antibodies responsible for providing fluorescence or chemiluminescent and colorimetric signals, respectively. The system incorporated a micron-sized thin-film hydrogenated amorphous silicon photodiode microfabricated on a glass substrate. The primary antibody spots in the PDMS-based microfluidic were precisely aligned with the photodiodes for the direct detection of the antibody-antigen molecular recognition reactions using chemiluminescence and colorimetry. The immunoassay takes ~30 min from assay to the integrated detection. The conditions for probe antibody microspotting and for the flow-through ELISA analysis in the microfluidic format with integrated detection were defined using antibody solutions with concentrations in the nM-μM range. Sequential colorimetric or chemiluminescence detection of specific antibody-antigen molecular recognition was quantitatively detected using the photodiode. Primary antibody surface densities down to 0.182 pmol cm(-2) were detected. Multiplex detection using different microspotted primary antibodies was demonstrated.  相似文献   

14.
A fluorescence detection system for a microfluidic device using an organic light-emitting diode (OLED) as the excitation light source and a charge-coupled device (CCD) as the photo detector was developed. The OLED was fabricated on a glass plate by photolithography and a vacuum deposition technique. The OLED produced a green luminescence with a peak emission at 512 nm and a half bandwidth of 55 nm. The maximum external quantum efficiency of the OLED was 7.2%. The emission intensity of the OLED at 10 mA/cm(2) was 13 μW (1.7 mW/cm(2)). The fluorescence detection system consisted of the OLED device, two band-pass filters, a five microchannel poly(dimethylsiloxane) (PDMS) microfluidic device and a linear CCD. The fluorescence detection system was successfully used in a flow-based enzyme-linked immunosorbent assay on a PDMS microfluidic device for the rapid determination of immunoglobulin A (IgA), a marker for human stress. The detection limit (S/N=3) for IgA was 16.5 ng/mL, and the sensitivity was sufficient for evaluating stress. Compared with the conventional 96-well microtiter plate assay, the analysis time and the amounts of reagent and sample solutions could all be reduced.  相似文献   

15.
A novel microfluidic method of continually detecting and counting beads‐labeled cells from a cell mixture without fluorescence labeling was presented in this paper. The detection system is composed of a microfluidic chip (with a permanent magnet inserted along the channel), a signal amplification circuit, and a LabView® based data acquisition device. The microfluidic chip can be functionally divided into separation zone and detection zone. By flowing the pre‐labeled sample solution, the target cells will be sequentially separated at the separation zone by the permanent magnet and detected and counted at the detection zone by a microfluidic resistive pulse sensor. Experiments of positive separation and detection of T‐lymphocytes and negative separation and detection of cancer cells from the whole blood samples were carried out to demonstrate the effectiveness of this method. The methodology of utilizing size difference between magnetic beads and cell‐magnetic beads complex for beads‐labeled cell detection is simple, automatic, and particularly suitable for beads‐based immunoassay without using fluorescence labeling.  相似文献   

16.
This article describes the use of microfluidic paper-based analytical devices (μPADs) to perform quantitative chemical assays with internal standards. MicroPADs are well-suited for colorimetric biochemical assays; however, errors can be introduced from the background color of the paper due to batch difference and age, and from color measurement devices. To reduce errors from these sources, a series of standard analyte solutions and the sample solution are assayed on a single device with multiple detection zones simultaneously; an analyte concentration calibration curve can thus be established from the standards. Since the μPAD design allows the colorimetric measurements of the standards and the sample to be conducted simultaneously and under the same condition, errors from the above sources can be minimized. The analytical approach reported in this work shows that μPADs can perform quantitative chemical analysis at very low cost.   相似文献   

17.
Yang S  Undar A  Zahn JD 《Lab on a chip》2007,7(5):588-595
A microfluidic device for continuous biosensing based on analyte binding with cytometric beads is introduced. The operating principle of the continuous biosensing is based on a novel concept named the "particle cross over" mechanism in microfluidic channels. By carefully designing the microfluidic network the beads are able to "cross-over" from a carrier fluid stream into a recipient fluid stream without mixing of the two streams and analyte dilution. After crossing over into the recipient stream, bead processing such as analyte-bead binding may occur. The microfluidic device is composed of a bead solution inlet, an analyte solution inlet, two washing solution inlets, and a fluorescence detection window. To achieve continuous particle cross over in microfluidic channels, each microfluidic channel is precisely designed to allow the particle cross over to occur by conducting a series of studies including an analogous electrical circuit study to find optimal fluidic resistances, an analytical determination of device dimensions, and a numerical simulation to verify microflow structures within the microfluidic channels. The functionality of the device was experimentally demonstrated using a commercially available fluorescent biotinylated fluorescein isothiocyanate (FITC) dye and streptavidin coated 8 microm-diameter beads. After, demonstrating particle cross over and biotin-streptavidin binding, the fluorescence intensity of the 8 microm-diameter beads was measured at the detection window and linearly depends on the concentration of the analyte (biotinylated FITC) at the inlet. The detection limit of the device was a concentration of 50 ng ml(-1) of biotinylated FITC.  相似文献   

18.
A novel microfluidic paper‐based analytical device (μPAD) utilizing a nitrocellulose (NC) membrane to detect IgG antibodies through a colorimetric analysis is described. The μPAD was constructed using layered polyethylene terephthalate (PET) and pressure‐sensitive adhesives (PSA). The biotin labeled Goat Anti‐Mouse IgG antibody was spotted and dried on the NC channel prior to subjecting it to a series of wash solutions (Tris‐tween), increasing concentrations of alkaline phosphatase conjugated to streptavidin (Strep‐ALP), and para‐nitrophenyl phosphate (p‐NPP) realizing a vibrant yellow color. The reaction proceeds for 10 min before applying the p‐NPP stop solution. The device was then dried, scanned, and analyzed yielding a linear range of inverse yellow color intensities versus Strep‐ALP concentrations. The development of this simple μPAD should further facilitate the use of NC in colorimetric assays to detect and quantitate antibodies.  相似文献   

19.
This paper describes a platform for real-time sensing of dissolved oxygen in a flowing microfluidic environment using an oxygen-sensitive luminescent dye (platinum octaethylporphyrin ketone) integrated into a micro-oxygenator device. Using a phase-based detection method, the luminescent decay lifetime of the dye was consistent with the linear Stern-Volmer relationship using both gaseous and aqueous samples. Maximum sensor resolution varied between 120-780 ppb across a range of dissolved oxygen (DO) concentrations ranging from 0-42.5 ppm. The sensor was subsequently used to determine the convective mass-transfer characteristics of a multi-layer polydimethylsiloxane (PDMS) microfluidic oxygenator. The membrane-based oxygenator showed excellent agreement with an analytical convection model, and the integrated oxygen sensor was accurate across a wide range of tested flow rates (0.05-5 mL min(-1)). The device is unique for its ease of fabrication and highly flexible configuration, as well as the novel incorporation of oxygen delivery and detection in a single micro-device. Potential applications include tissue engineering, cell culturing, and miniaturized bio-assays that require the delivery and/or detection of precise quantities of oxygen within a microfluidic construct.  相似文献   

20.
Zhang J  Liu S  Yang P  Sui G 《Lab on a chip》2011,11(20):3516-3522
Herein we report fabricating a microfluidic device to monitor harmful algal blooming (HAB). The heterogeneous immuno-enzyme assay was integrated into a self-designed microfluidic chip for rapid and automatic analysis of algal toxins. The device was made from polydimethylsiloxane (PDMS) and was assembled with a home-made control system. The performance of the system was demonstrated by the detection of microcystin, saxitoxin and cylindrospermopsin, the major cyanotoxins. In one single microfluidic chip, multiple samples were controlled and analysed in a parallel manner. Under the optimal conditions, the linear range and the limit of detection of microcystins were 0-5.0 ng mL(-1) and 0.02 ng mL(-1) respectively. The total analysis time was less than 25 min. The designed device was highly automatic, more efficient and economic compared to conventional techniques.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号