首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A sensitive and precise stir bar sorptive extraction (SBSE) combined with LC (SBSE/LC) analysis is described for simultaneous determination of methyl, ethyl, propyl, and butyl parabens in commercial cosmetic products in agreement with the European Union Cosmetics Directive 76/768/EEC. Important factors in the optimization of SBSE efficiency are discussed, such as time and temperature of extraction, pH, and ionic strength of the sample, matrix effects, and liquid desorption conditions by different modes (magnetic stirring, ultrasonic). The LOQs of the SBSE/LC method ranged from 30 to 200 ng/mg, with linear response over a dynamic range, from the LOQ to 2.5 μg/mg, with a coefficient of determination higher than 0.993. The interday precision of the SBSE/LC method presented a coefficient of variation lower than 5%. The effectiveness of the proposed method was proven for analysis of commercial cosmetic products such as body creams, antiperspirant creams, and sunscreens.  相似文献   

2.
A new polymeric coating consisting of a dual-phase, polydimethylsiloxane (PDMS) and polypyrrole (PPY) was developed for the stir bar sorptive extraction (SBSE) of antidepressants (mirtazapine, citalopram, paroxetine, duloxetine, fluoxetine and sertraline) from plasma samples, followed by liquid chromatography analysis (SBSE/LC-UV). The extractions were based on both adsorption (PPY) and sorption (PDMS) mechanisms. SBSE variables, such as extraction time, temperature, pH of the matrix, and desorption time were optimized, in order to achieve suitable analytical sensitivity in a short time period. The PDMS/PPY coated stir bar showed high extraction efficiency (sensitivity and selectivity) toward the target analytes. The quantification limits (LOQ) of the SBSE/LC-UV method ranged from 20 ng mL−1 to 50 ng mL−1, and the linear range was from LOQ to 500 ng mL−1, with a determination coefficient higher than 0.99. The inter-day precision of the SBSE/LC-UV method presented a variation coefficient lower than 15%. The efficiency of the SBSE/LC-UV method was proved by analysis of plasma samples from elderly depressed patients.  相似文献   

3.
Analysis of wine primary aroma compounds by stir bar sorptive extraction   总被引:2,自引:0,他引:2  
A. Zalacain  G.L. Alonso 《Talanta》2007,71(4):1610-1615
Due to the great importance of some primary aroma compounds on wine quality, these compounds which includes terpenes, C13-norisoprenoids and C6 compounds, have been analyzed by stir bar sorptive extraction (SBSE) followed by a thermal desorption-gas chromatography-mass spectrometry analysis. The stir bar sorptive extraction method was optimized in terms of temperature, time, pH and NaCl addition. The best SBSE sorption kinetics for the target analytes were obtained after submitting the solutions to 60 °C during 90 min. The addition of sodium chloride did not enhance the volatile extraction. The method proposed showed good linearity over the concentration range tested, with correlation coefficients higher than 0.98 for all the analytes. The reproducibility and repeatability of the method was estimated between 0.22 and 9.11%. The detection and quantification limits of all analytes were lower than their respective olfactory threshold values. The application of this SBSE method revealed that monovarietal white wines were clearly separated by two canonic discriminating functions when grape varieties were used as differentiating variable, the first of which explained 98.4% of the variance. The compounds which contributed most to the differentiation were limonene, linalool, nerolidol and 1-hexanol.  相似文献   

4.
A comparison of direct immersion solid-phase microextraction (DI-SPME) and stir bar sorptive extraction (SBSE) coupled to liquid chromatography (HPLC) with fluorimetric detection for the rapid analysis of resveratrol isomers is described. For DI-SPME, a polar Carbowax-template resin (CW/TPR) 50 μm fiber was the most efficient and optimum extraction conditions were 40 °C and an extraction time of 30 min, stirring in the presence of 5% (m/v) sodium chloride and 0.07 M acetate/acetic acid buffer (pH 6). Desorption was carried out using the static mode for 10 min. Linearity was obtained in the 5-150 and 2-150 ng mL−1 ranges for trans- and cis-resveratrol, with detection limits of 2 and 0.5 ng mL−1, respectively. When using SBSE, a polydimethylsiloxane (PDMS) twister provided best extraction by means of a derivatization reaction in the presence of acetic anhydride and potassium carbonate. The same time and temperature were used for the extraction step in the presence of 2.5% (m/v) sodium chloride, and liquid desorption was performed with 150 μL of a 50/50 (v/v) acetonitrile/1% (v/v) acetic acid solution in a desorption time of 15 min. Linearity was now between 0.5 and 50 ng mL−1 for trans-resveratrol with a detection limit of 0.1 ng mL−1, while cis-resveratrol could not be extracted. The proposed methods were successfully applied to determining the resveratrol isomer content of wine, must and fruit juices.  相似文献   

5.
A new method, stir bar sorptive extraction (SBSE) with in situ derivatization and thermal desorption (TD)-gas chromatography-mass spectrometry (GC-MS), which is used for the determination of trace amounts of chlorophenols, such as 2,4-dichlorophenol (2,4-DCP), 2,4,6-trichlorophenol (2,4,6-TrCP), 2,3,4,6-tetrachlorophenol (2,3,4,6-TeCP) and pentachlorophenol (PCP), in tap water, river water and human urine samples, is described. The derivatization conditions with acetic acid anhydride and the SBSE conditions such as extraction time are investigated. Then, the stir bar is subjected to TD followed by GC-MS. The detection limits of the chlorophenols in tap water, river water and human urine samples are 1-2, 1-2, and 10-20 pg ml−1 (ppt), respectively. The calibration curves for the chlorophenols are linear and have correlation coefficients higher than 0.99. The average recoveries of the chlorophenols in all the samples are higher than 95% (R.S.D. < 10%) with correction using added surrogate standards, 2,4-dichlorophenol-d5, 2,4,6-trichlorophenol-13C6, 2,3,4,6-tetrachlorophenol-13C6 and pentachlorophenol-13C6. This simple, accurate, sensitive and selective analytical method may be applicable to the determination of trace amounts of chlorophenols in liquid samples.  相似文献   

6.
A method for the determination of ultra-trace amounts of organochlorine pesticides (OCPs) in river water was developed by using stir bar sorptive extraction (SBSE) followed by thermal desorption and comprehensive two-dimensional gas chromatography coupled to high-resolution time-of-flight mass spectrometry (SBSE-TD-GC×GC-HRTOF-MS). SBSE conditions such as extraction time profiles, phase ratio (β: sample volume/polydimethylsiloxane (PDMS) volume), and modifier addition, were examined. Fifty milli-liter sample including 10% acetone was extracted for 3 h using stir bars with a length of 20 mm and coated with a 0.5 mm layer of PDMS (PDMS volume, 47 μL). The stir bar was thermally desorbed and subsequently analyzed by GC×GC-HRTOF-MS. The method showed good linearity over the concentration range from 50 to 1000 pg L(-1) or 2000 pg L(-1) for all analytes, and the correlation coefficients (r(2)) were greater than 0.9903 (except for β-HCH, r(2)=0.9870). The limit of detection (LOD) ranged from 10 to 44 pg L(-1). The method was successfully applied to the determination of 16 OCPs at pg L(-1) to ng L(-1) in river water. The results agree fairly well with the values obtained by a conventional liquid-liquid extraction (LLE)-GC-HRMS (selected ion monitoring: SIM) method using large sample volume (20 L). The method also allows screening of non-target compounds, e.g. pesticides and their degradation products, polyaromatic hydrocarbons (PAHs), polychlorinated biphenyls (PCBs), and pharmaceuticals and personal care products (PPCPs) and metabolites in the same river water sample, by using full spectrum acquisition with accurate mass in GC×GC.  相似文献   

7.
Stir bar sorptive extraction for the analysis of wine cork taint   总被引:1,自引:0,他引:1  
A magnetic stir bar with a polydimethylsiloxane coating was used to absorb 2,4,6-trichloroanisole, 2,3,4,5-tetrachloroanisole, pentachloroanisole and their respective phenols from synthetic and real wine samples. The stir bar sorptive extraction method was optimised to obtain the best extraction conditions in terms of temperature, time, pH and NaCl addition. The stir bar was desorbed in a thermal desorption system coupled to a gas chromatograph-mass spectrometer. The method proposed showed good linearity over the concentration range tested and correlation coefficients ranged from 0.96 to 0.99 for all the analytes. The reproducibility and repeatability of the method was estimated between 1.29 and 4.02%. With no a pre-concentration step and with a much reduced analysis time, all the analyzed compounds showed detection and quantification limits that were lower than those observed with other methods found in the bibliography. Except for pentachlorophenol due to its poor absorptivity in polydimethysiloxane, in red wines, LOD ranged between 7.56 and 61.56 pg/l, and LOQ ranged between 17.21 and 205.11 pg/l; while in white wines, the LOD ranged between 5.82 and 30.50 pg/l and LOQ ranged between 19.41 and 101.61 pg/l. These concentrations were always lower than their respective olfactory thresholds values.  相似文献   

8.
Xu Z  Song C  Hu Y  Li G 《Talanta》2011,85(1):97-103
A novel sulfamethazine molecularly imprinted polymer (MIP)-coated stir bar for sorptive extraction of eight sulfa drugs from biological samples was prepared. The MIP-coating was about 20 μm thickness with the relative standard deviation (RSD) of 6.7% (n = 10). It was characterized by scanning electron microscope, infrared spectrum, thermogravimetric analysis, and solvent-resistant investigation, respectively. The non-imprinted polymer (NIP)-coating was used for comparison. The adsorptive capacity and selectivity of MIP-coating were evaluated in detail. The MIP-coating showed higher adsorption capability and selectivity than the NIP-coating. The saturated adsorption amount of the MIP-coating was 4.6 times over that of the NIP-coating in toluene. Sulfamethazine could be detected after the MIP-coated stir bar sorptive extraction even at a low concentration of 0.2 μg/L. The MIP-coating also exhibited selective adsorption ability to analogues of the template. A method for the determination of eight sulfa drugs in biological samples by MIP coated stir bar sorptive extraction coupled with high performance liquid chromatography (HPLC) was developed. The extraction conditions, including extraction solvent, extraction time, desorption solvent, desorption time and stirring speed, were optimized. The linear ranges were 1.0-100 μg/L and 2.0-100 μg/L for eight sulfonamides, respectively. The detection limits were within the range of 0.20-0.72 μg/L. The method was successfully applied to simultaneous multi-residue analysis of eight sulfonamides in spiked pork, liver and chicken samples with the satisfactory recoveries.  相似文献   

9.
An optimised method using stir bar sorptive extraction (SBSE) and a thermal desorption‐GC‐electron capture detector (GC‐ECD) for the determination of short‐chain chlorinated paraffins from water samples was developed. Recoveries near to 100% were obtained by using 20 mm×0.5 mm (length×film thickness) PDMS commercial stir bars from 200 mL spiked water samples and 20% methanol addition with an extraction period of 24 h. Method sensitivity, linearity and precision were evaluated for surface water and wastewater spiked samples. A LOD of 0.03 and 0.04 μg/L was calculated for surface and wastewater, respectively. The precision of the method given as an RSD was below 20% for both matrices. The developed method was applied for the analysis of two real samples from a contaminated river and a wastewater treatment plant. Results were in accordance with those obtained using a previously developed method based on solid phase microextraction (SPME).  相似文献   

10.
Based on a special homemade interface, the molecularly imprinted stir bar sorptive extraction was coupled to high performance liquid chromatography for the online desorption and analysis. During desorption, the analytes desorbed from stir bar were delivered to a sample loop and then was introduced into liquid chromatography for further analysis. The online desorption and introduction processes were real‐time monitored by the ultraviolet detector of the liquid chromatography system. In this way, the method sensitivity and reproducibility was improved for the introduction timing of the desorption solvent with greatest concentration of the target analytes was accurately controlled. To demonstrate the feasibility of the method, terbuthylazine imprinted stir bar was synthesized and used for the analysis of nine triazines in rice. Under the optimized conditions, limits of detection of 0.02–0.11 μg/L and precision within 4.3–7.2% were achieved. The new method was compared with other two traditional offline desorption procedures, i.e. ultrasonic‐assisted desorption and static thermal desorption. The comparison results showed that the proposed method is accurate, precise, fast, and suitable for the trace analysis of complex samples.  相似文献   

11.
利用自制的以聚(乙烯基咪唑-二乙烯基苯)(VIDB)整体材料为涂层的固相萃取搅拌棒(VIDB-SBSE)萃取3种硝基呋喃类药物,然后与高效液相色谱-二极管阵列检测器联用建立了测定饲料和水样品中硝基呋喃类药物残留的方法。详细考察了萃取过程中萃取和解吸时间、样品基质的pH值以及离子强度等实验条件对萃取效率的影响。在最佳条件下,呋喃唑酮的线性范围为0.5~200μg/L,呋喃妥因和呋喃西林的线性范围为0.25~200μg/L,3种目标物的检出限(LO D)(S/N=3)在0.068~0.11μg/L之间,所建方法具有理想的日内和日间重现性(R SD值均小于6%)。在对饲料和实际水样的测定中,不同加标浓度呋喃唑酮、呋喃妥因和呋喃西林的回收率在80.6%~108%之间。研究表明,所建立的方法具有简便、灵敏、环境友好等特点。  相似文献   

12.
搅拌棒固相萃取的研究进展   总被引:1,自引:0,他引:1  
Chen L  Huang X  Yuan D 《色谱》2011,29(5):375-381
作为一种新型的环境友好型样品前处理技术,搅拌棒固相萃取(SBSE)集萃取、净化和富集为一体,已经在环境监测、食品安全和生物分析等领域进行了广泛应用。本文结合作者所在研究小组的研究工作,对近几年来SBSE技术的发展进行综述,重点阐述了各种新涂层的研究和应用,同时就SBSE发展方向提出了展望。  相似文献   

13.
A review with 75 references is presented that deals with the reported methods for analysis of some important central nervous system (CNS) drugs in biological fluids utilizing stir bar sorptive extraction (SBSE) technique covering the years from 2000 to 2008. The theoretical aspects of SBSE, as well as an significant number of applications have been published, showing the advantages of this technique over the classical extraction techniques (liquid–liquid extraction (LLE) and solid-phase extraction (SFE). In this review, recent SBSE developments and a focus on the development of new instrumental approaches and sorbent phases are presented.  相似文献   

14.
A method for the trace analysis of methylmercury (MeHg) and Hg(II) in water sample was developed, which involved stir bar sorptive extraction (SBSE) with in situ alkylation with sodium tetraethylborate and thermal desorption (TD)-gas chromatography-mass spectrometry (GC-MS). The limits of quantification of MeHg and Hg(II) are 20 and 10 ng L−1 (Hg), respectively. The method shows good linearity and the correlation coefficients are higher than 0.999. The average recoveries of MeHg and Hg(II) in tap or river water sample are 102.1-104.3% (R.S.D.: 7.0-8.9%) and 105.3-106.2% (R.S.D.: 7.4-8.5%), respectively. This simple, accurate, sensitive, and selective analytical method may be used in the determination of trace amounts of MeHg and Hg(II) in tap and river water samples.  相似文献   

15.
In the present study, a stir bar coated with hydrophilic polymer based on poly(N-vinylpyrrolidone-co-divinylbenzene) was prepared for the sorptive extraction of polar compounds. The main parameters affecting the polymerisation of the coating were investigated.The new stir bar was applied successfully in stir bar sorptive extraction with liquid desorption followed by liquid chromatography–mass spectrometry in tandem with a triple quadrupole for the determination of a group of polar pharmaceuticals and personal care products (PPCPs) in environmental water matrices. Different variables affecting extraction and desorption such as agitation speed, temperature, ionic strength and extraction time were optimised. The results showed that the stir bar is able to enrich the selected analytes effectively.The developed method was applied to determine a group of PPCPs in different complex environmental samples, including river, effluent and influent waste water.  相似文献   

16.
A simple and highly sensitive method called thermal desorption (TD)-gas chromatography-mass spectrometry (GC-MS), which is used for the determination of trace amounts of 4-nonylphenol (NP) and 4-tert.-octylphenol (OP) in water samples, is described. NP and OP in samples are extracted from water samples and concentrated by the stir bar sorptive extraction (SBSE) technique. A stir bar coated with polydimethylsiloxane (PDMS) is added to a 2.0 ml water sample and stirring is carried out for 60 min at room temperature (25 °C) in a headspace vial. Then the extract is high sensitively analyzed by TD-GC-MS without any derivatization step. The optimum SBSE conditions are realized at an extraction time of 60 min. The detection limits are 0.02 ng ml−1 for NP and 0.002 ng ml−1 for OP. The method shows good linearity over the concentration range of 0.1-10 ng ml−1 for NP and 0.01-10 ng ml−1 for OP, and the correlation coefficients are higher than 0.999. The average recoveries of NP and OP are higher than 97% (R.S.D.: 3.6-6.2%) with correction using the added surrogate standards, 4-(1-methyl) octylphenol-d5 and deuterium 4-tert.-octylphenol. This simple, accurate, sensitive and selective analytical method may be used in the determination of trace amounts of NP and OP in tap and river water samples.  相似文献   

17.
林福华  黄晓佳  袁东星  刘宝敏 《色谱》2010,28(5):507-512
以双酚A(BPA)为单体,利用整体材料“原位”聚合技术制备以分子印迹聚合物为涂层的吸附萃取搅拌棒(MIP-SBSE),然后与高效液相色谱(HPLC)-二极管阵列检测器联用,探讨其对环境水样BPA的选择萃取性能。优化萃取过程中吸附和解吸时间、解吸液种类以及基底pH值和离子强度对目标化合物的选择吸附性能。在最佳条件下,MIP-SBSE可对模板分子进行有效的选择吸附,线性范围为1.0~200 μg/L,检出限(S/N=3)和定量限(S/N=10)分别为0.28μg/L和0.94 μg/L。在实际水样分析中,具有良好的加标回收率,其值为96.0%~108.7%。研究结果表明,所建立的方法具有简便、灵敏和环境友好等特点。  相似文献   

18.
Stir bar sorptive extraction with liquid desorption followed by large volume injection coupled to gas chromatography-quadrupole mass spectrometry (SBSE-LD/LVI-GC-qMS) was applied for the quantification of varietal and fermentative volatiles in sparkling wines. The analytical data were performed by using suitable standards of monoterpene hydrocarbons (α-pinene), monoterpenols (linalool), sesquiterpenoids (E,E-farnesol, Z-nerolidol, and guaiazulene), C13 norisoprenoids (β-ionone), aliphatic and aromatic alcohols (hexanol and 2-phenylethanol), and esters (hexyl acetate and ethyl decanoate) as model compounds. The wine volatiles were quantified using the structurally related standards. The methodology showed good linearity over the concentration range tested, with correlation coefficients ranging from 0.950 to 0.997, and a reproducibility of 9-18%. The SBSE-LD/LVI-GC-qMS methodology allowed, in a single run, the quantification of 71 wine volatiles that can be quantified accurately at levels lower than their respective olfactory thresholds. This methodology was used for assessment of sparkling wine volatiles from different soils, ripening stages, and varieties. The variety and soil influenced significantly the volatile composition of sparkling wines; lower effect was observed for the ripening stage of grapes picked up one week before or after the maturity state.  相似文献   

19.
This study presents the development of an analytical method for determining 9 synthetic musks in water matrices. The developed method is based on stir bar sorptive extraction (SBSE), coated with polydimethylsiloxane, and coupled with a thermal desorption–gas chromatography–mass spectrometry system (TD–GC–MS). SBSE can efficiently trap and desorb the analytes providing low limits of detection (between 0.02 ng L−1 and 0.3 ng L−1). Method validation showed good linearity, repeatability and reproducibility for all compounds. Furthermore, the limited manipulation of the sample required in this method implies a significant decrease of the risk of external contamination of the samples. The performance of the method in real samples was evaluated by analysing biological wastewater treatment plant (WWTP) influent and effluent samples, reverse osmosis treatment plant effluents and river waters. The most abundant musk was galaxolide with values up to 2069 ng L−1 and 1432 ng L−1 in the influent and effluent of urban WWTP samples, respectively. Cashmeran, Pantolide and Tonalide were also detected in all the matrices with values up to 94 ng L−1, 26 ng L−1 and 88 ng L−1, respectively. Although in Europe the use of nitromusks in cosmetics is prohibited, musk xylene and musk ketone were detected both in the WWTP and in the river samples. As far as we know, this is the first time than a SBSE method coupled with TD is applied for the determination of synthetic musks in water samples.  相似文献   

20.
This study presents the optimization and application of an analytical method based on the use of stir bar sorptive extraction (SBSE) gas chromatography coupled to mass spectrometry (GC–MS) for the ultra-trace analysis of POPs (Persistent Organic Pollutants) in Arctic ice. In a first step, the mass-spectrometry conditions were optimized to quantify 48 compounds (polycyclic aromatic hydrocarbons, brominated diphenyl ethers, chlorinated biphenyls, and organochlorinated pesticides) at the low pg/L level. In a second step, the performance of this analytical method was evaluated to determine POPs in Arctic cores collected during an oceanographic campaign. Using a calibration range from 1 to 1800 pg/L and by adjusting acquisition parameters, limits of detection at the 0.1–99 and 102–891 pg/L for organohalogenated compounds and polycyclic aromatic hydrocarbons, respectively, were obtained by extracting 200 mL of unfiltered ice water. α-hexachlorocyclohexane, DDTs, chlorinated biphenyl congeners 28, 101 and 118 and brominated diphenyl ethers congeners 47 and 99 were detected in ice cores at levels between 0.5 to 258 pg/L. We emphasise the advantages and disadvantages of in situ SBSE in comparison with traditional extraction techniques used to analyze POPs in ice.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号