首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A sensitive and reliable liquid chromatographic-tandem mass spectrometric method for enantiomeric determination of five chiral azole antifungals (econazole, ketoconazole, miconazole, tebuconazole, and propiconazole) in wastewater and sludge has been established and validated. An isotope-labeled internal standard was used for quantification. Recovery of the individual enantiomers was usually in the range of 77-102 % for wastewater and 71-95 % for sludge, with relative standard deviations within 20 %. No significant difference (p>0.05) was observed between recovery of pairs of enantiomers of the chiral azole antifungals except for those of tebuconazole. Method quantification limits for individual enantiomers were 0.3-10 ng L(-1) and 3-29 ng g(-1) dry weight for wastewater and sludge, respectively. The method was used to investigate the enantiomeric composition of the azole pharmaceuticals in wastewater and sludge samples from a sewage treatment plant in China. Enantiomers of miconazole, ketoconazole, and econazole were widely detected. The results showed that the azole antifungals in wastewater and sludge were generally racemic or marginally non-racemic. The method is a useful tool for investigation of the enantiomeric occurrence, behavior, and fate of the chiral azole antifungals in the environment.  相似文献   

2.
We describe the development of a liquid chromatography with negative-ion atmospheric pressure photoionization tandem mass spectrometric (LC/NI-APPI/MS/MS) method for the simultaneous determination of tetrabromobisphenol A (TBBP-A) and five polybrominated diphenyl ethers (BDE-47, BDE-99, BDE-100, BDE-153 and BDE-154) in water. A mobile phase methanol/acetone/water was used, where acetone acts also as dopant. NI-APPI produced precursor ions corresponding to [M−H] for TBBP-A, [M−Br+O], and [M−2Br+O] for the BDE congeners studied. Each compound was quantified operating in multiple reaction monitoring mode. Linearity was observed in the range 0.025–10 ng injected for all compounds. Coefficients of determination R2 ranged from 0.9934 to 0.9982. BDEs were poorly retained by solid-phase extraction (SPE) from river water and sewage treatment plant effluent, thus liquid–liquid extraction (LLE) by n-hexane should be used for these samples. The recoveries of TBBP-A and PBDEs from tap water (SPE), river water and industrial wastewater (LLE) were in the range of 81–88%, 78–92%, and 43–99%, respectively, with relative standard deviations below 17%. The limits of detection, based on signal-to-noise ratio of 3, ranged from 0.004 to 0.1 ng injected, and method quantification limits were 0.2–3.3 ng L−1 but BDE47 (20.3 ng L−1). Only TBBP-A was found in a treated industrial sewage at 4 ng L−1, while BDE-99 and BDE-100 were detected on suspended solids.  相似文献   

3.
A simple, rapid, and sensitive method based on simultaneous protein precipitation and extraction of aflatoxin M1 (AFM1) followed by dispersive liquid–liquid microextraction (DLLME) and ultrahigh pressure liquid chromatography tandem mass spectrometry (UHPLC-MS/MS) analysis was developed for the determination of AFM1 in milk samples. In order to precipitate the proteins and extract AFM1 from milk, a sample pretreatment using acetonitrile and NaCl as the extraction/denaturant solvent and salting-out agent, respectively, was optimised. Subsequently, the acetonitrile (upper) phase, containing AFM1, was used as the disperser solvent in DLLME, and extractant (chloroform) and water were added in turn to the extract to perform the DLLME process. The main parameters affecting the extraction efficiency of the whole analytical procedure, such as acetonitrile volume, amount of salt, type and volume of extractant and water volume, were carefully optimised by experimental design. Under optimum conditions, the developed method provides an enrichment factor of 33 and detection and quantification limits (0.6 and 2.0 ng kg?1, respectively) below the maximum levels imposed by current regulations for AFM1 in milk and infant milk formulae. Recoveries (61.3–75.3 %) and repeatability (RSD?<?10, n?=?3), tested in different types of milk at four AFM1 levels, met the performance criteria required by EC Regulation No. 401/2006. Moreover, the matrix effect on the signal intensity of the analyte was negligible. The proposed method provides a rapid extraction and an accurate determination of AFM1 in milk and formula milk using a simple and inexpensive sample preparation procedure.
Figure
Rapid analysis of aflatoxin M1 in milk using DLLME  相似文献   

4.
This study presents a focused ultrasound solid-liquid extraction (FUSLE) and gas chromatography tandem mass spectrometry method for the determination of brominated diphenyl ethers (BDEs), from mono- to hexa-congeners, in indoor dust. This approach provided a simple, fast, and economical method. After the solvent extraction selection, the FUSLE conditions were studied using a central composite design. Finally, the number of extraction cycles was studied. The selected conditions were 8?mL of 3:1 n-hexane-acetone mixture as extraction solvent, at a power of 65% for 20?s. The proposed method allowed accurate determination of BDEs, with recovery values around 100% and detection limits between 0.05 and 0.8?ng?g(-1). It also has advantages over other existing methods in terms of simplicity, analysis time, and solvent consumption. The analysis of several indoor dust samples showed high concentration values of BDEs 47, 99, 100, 153, and 154 in some of the samples, moreover, BDEs 47 and 99 were found in all samples.  相似文献   

5.
A comprehensive, sensitive and high-throughput liquid chromatography–atmospheric pressure photoionization tandem mass spectrometry (LC–APPI-MS/MS) method has been developed for analysis of 36 halogenated flame retardants (HFRs). Under the optimized LC conditions, all of the HFRs eluted from the LC column within 14 min, while maintaining good chromatographic separation for the isomers. Introduction of the pre-heated dopant to the APPI source decreased the background noise fivefold, which enhanced sensitivity. An empirical equation was proposed to describe the relation between the ion intensity and dopant flow. The excellent on-column instrument detection limits averaged 4.7 pg, which was similar to the sensitivity offered by gas chromatography–high-resolution mass spectrometry (GC–HRMS). This method was used to analyze a series of fish samples. Good agreement was found between the results for PBDEs from LC–APPI-MS/MS and GC–HRMS.  相似文献   

6.
This paper describes a method for the determination of a group of personal care products including four UV filters, four preservatives and two antimicrobials in sewage sludge. The method combines pressurized liquid extraction and ultra high performance liquid chromatography–tandem mass spectrometry. Most of the parameters that affect the extraction step such as temperature, pressure, static extraction time, number of cycles, purge time and flush volume were optimized using a fractional experimental design. In the chromatographic step, the compounds were detected by using tandem mass spectrometry with a triple quadrupole analyzer with electrospray ionization in positive and negative modes. The use of small diameter particles (1.8 μm) in the chromatographic column allowed the compounds to be eluted in 9 min. The entire process took a total of 39 min. All recoveries were higher than 72% except for 2,4-dihydroxybenzophenone (a UV filter), whose recovery was 30%. The repeatability and reproducibility between days expressed as RSD (%) (n = 3) were less than 8% and 13%, respectively. The LODs and LOQs were lower than 8 μg/kg and 12.5 μg/kg of dry weight (d.w.), respectively. When the method was applied to determine the compounds in sewage sludge from a domestic sewage treatment plant, triclosan (an antimicrobial) and octocrylene (a UV filter) showed the highest levels, 1490 μg/kg (d.w.) and 1842 μg/kg (d.w.), respectively. This paper describes for the first time the determination of parabens and two UV filters (octyldimethyl-p-aminobenzoic acid and benzophenone-3) in sewage sludge.  相似文献   

7.
Sensitive and reliable methods have been developed and validated for determination of commonly consumed azole antifungal pharmaceuticals (clotrimazole, econazole, ketoconazole, and miconazole) and biocides (propiconazole and tebuconazole) in various waters and sewage sludge. Solid phase extraction (SPE) combined with ultra-high performance liquid chromatography–tandem mass spectrometry (UHPLC–MS/MS) was used to determine the azole antifungals in waters. Azole antifungals in sewage sludge were extracted with ultrasonic-assisted extraction, followed by SPE cleanup and UHPLC–MS/MS detection. Quantification was performed by internal standard calibration in multiple reaction monitoring mode. Recoveries were mostly in the range of 52–110% with relative standard deviations generally within 20%. Method quantification limits were 0.5–6 ng L−1 in waters and 3–9 ng g−1 dry weight (dw) in sewage sludge, respectively. The methods were applied to determine the azole antifungals in wastewater, river water, sediment, and sewage sludge sampled from the Pearl River Delta, China. Clotrimazole, ketoconazole, and miconazole were widely detected at low ng L−1 in waters, low ng g−1 dw in river sediment, and low μg g−1 dw in sewage sludge. The methods can provide valuable tools for investigating occurrence and fate of the azole antifungals in the environment.  相似文献   

8.
A method using reversed phase liquid chromatography–electrospray ionization–tandem mass spectrometry was developed for the determination of 52 pesticides in tobacco. The influence of mobile phase additives was investigated to improve sensitivity and accuracy of the method and to reduce matrix effects. The tobacco extracts were purified via a Chem Elut partition cartridge by consecutive elution with pentane followed by dichloromethane. The two fractions were further purified by Florisil solid-phase extraction with acetone or diethyl ether elution. An additional dispersive solid-phase extraction step with primary–secondary amine led to decreased recoveries of several pesticides due to degradation or binding to the sorbent. The method was validated for the tobacco types Burley, Oriental and Virginia. The recovery rates of almost all pesticides ranged between 70 and 120%. The limits of quantification were below or near the 10 ng/g level. Few but significant differences between the tobacco types could be found regarding recovery and sensitivity.  相似文献   

9.
A novel method has been developed for the determination of alkylphenols in soil by ultra-high-pressure liquid chromatography employing small particle sizes, combined with tandem mass spectrometry. Soil samples were extracted with pressurized liquid extraction (PLE) and then cleaned with solid-phase extraction (SPE). The extracts were separated on C18 column (1.7 μm, 50 mm × 2.1 mm) with a gradient elution and a mobile phase consisting of water and acetonitrile, and then detected by an electrospray ionization tandem mass spectrometry in negative ion mode with multiple reaction monitoring (MRM). Compared with traditional liquid chromatography, it took ultra-high-pressure liquid chromatography much less time to analyze alkylphenols. Additionally, the ultra-high-pressure liquid chromatography/tandem mass spectrometry method produces satisfactory reliability, sensitivity, and accuracy. The average recoveries of the three target analytes were 74.0–103.4%, with the RSD < 15%. The calibration curves for alkylphenols were linear within the range of 0.01–0.4 μg/ml, with the correlation coefficients greater than 0.99. When 10 g soil sample was used for analysis, the limits of quantification (LOQs) of the three alkylphenols were all 1.0 μg/kg.  相似文献   

10.
Current urinary bladder cancer diagnosis is commonly based on a biopsy obtained during cystoscopy. This invasive method causes discomfort and pain in patients. Recently, taurine and several other compounds such as L-phenylalanine and hippuric acid in urine were found to be indicators of bladder cancer. However, because of a lack of sensitive and accurate analytical techniques, it is impossible to detect these compounds in urine at low levels. In this study, using liquid chromatography–tandem mass spectrometry (LC-MS/MS), a noninvasive method was developed to separate and detect these compounds in urine. 15N2-L-glutamine was used as the internal standard, and creatinine acted as an indicator for urine dilution. A phenyl-hexyl column was used for the separation at an isocratic condition of 0.2% formic acid in water and 0.2% formic acid in methanol. Analytes were detected in multiple-reaction monitoring with positive ionization mode. The limit of detection range is 0.18–6 nM and the limit of quantitation ranges from 0.6 to 17.6 nM. The parameters affecting separation and quantification were also investigated and optimized. Proper clinical validation of these biomarkers can be done using this reliable, fast, and simple method. Furthermore, with simple modifications, this method could be applied to other physiological fluids and other types of diseases.  相似文献   

11.
A sensitive and robust method using solid-phase extraction and ultrasonic extraction for preconcentration followed by ultra-high-performance liquid chromatography–tandem mass spectrometry (UHPLC–MS–MS) has been developed for determination of 19 biocides: eight azole fungicides (climbazole, clotrimazole, ketoconazole, miconazole, fluconazole, itraconazole, thiabendazole, and carbendazim), two insect repellents (N,N-diethyl-3-methylbenzamide (DEET), and icaridin (also known as picaridin)), three isothiazolinone antifouling agents (1,2-benzisothiazolinone (BIT), 2-n-octyl-4-isothiazolinone (OIT), and 4,5-dichloro-2-n-octyl-isothiazolinone (DCOIT)), four paraben preservatives (methylparaben, ethylparaben, propylparaben, and butylparaben), and two disinfectants (triclosan and triclocarban) in surface water, wastewater, sediment, sludge, and soil. Recovery of the target compounds from surface water, influent, effluent, sediment, sludge, and soil was mostly in the range 70–120?%, with corresponding method quantification limits ranging from 0.01 to 0.31?ng?L?1, 0.07 to 7.48?ng?L?1, 0.01 to 3.90?ng?L?1, 0.01 to 0.45?ng?g?1, 0.01 to 6.37?ng?g?1, and 0.01 to 0.73?ng?g?1, respectively. Carbendazim, climbazole, clotrimazole, methylparaben, miconazole, triclocarban, and triclosan were detected at low ng?L?1 (or ng?g?1) levels in surface water, sediment, and sludge-amended soil. Fifteen target compounds were found in influent samples, at concentrations ranging between 0.4 (thiabendazole) and 372?ng?L?1 (methylparaben). Fifteen target compounds were found in effluent samples, at concentrations ranging between 0.4 (thiabendazole) and 114?ng?L?1 (carbendazim). Ten target compounds were found in dewatered sludge samples, at concentrations ranging between 1.1 (DEET) and 887?ng?g?1 (triclocarban).  相似文献   

12.
This work describes a liquid chromatography–electrospray tandem mass spectrometry method for detection of desmopressin in human plasma in the low femtomolar range. Desmopressin is a synthetic analogue of the antidiuretic hormone arginine vasopressin and it might be used by athletes as a masking agent in the framework of blood passport controls. Therefore, it was recently added by the World Anti-Doping Agency to the list of prohibited substances in sport as a masking agent. Mass spectrometry characterization of desmopressin was performed with a high-resolution Orbitrap-based mass spectrometer. Detection of the peptide in the biological matrix was achieved using a triple-quadrupole instrument with an electrospray ionization interface after protein precipitation, weak cation solid-phase extraction and high performance liquid chromatography separation with an octadecyl reverse-phase column. Identification of desmopressin was performed using three product ions, m/z 328.0, m/z 120.0, and m/z 214.0, from the parent ion, m/z 535.5. The extraction efficiency of the method at the limit of detection was estimated as 40% (n = 10), the ion suppression as 5% (n = 10), and the limit of detection was 50 pg/ml (signal-to-noise ratio greater than 3). The selectivity of the method was verified against several endogenous and synthetic desmopressin-related peptides. The performance and the applicability of the method were tested by analysis of clinical samples after administration of desmopressin via intravenous, oral, and intranasal routes. Only after intravenous administration could desmopressin be successfully detected.  相似文献   

13.
Organophosphate triesters are common flame retardants used in a wide variety of consumer products from which they can migrate and pollute the indoor environment. Humans may thus be continuously exposed to several organophosphate triesters which might be a risk for human health. An analytical method based on direct injection of 5 μL urine into an ultra performance liquid chromatography system coupled to a time-of-flight mass spectrometry has been developed and validated to monitor exposure to organophosphate triesters through their respective dialkyl and diaryl phosphate metabolites (DAPs). The targeted analytes were: di-n-butyl phosphate (DNBP), diphenyl phosphate (DPHP), bis(2-butoxyethyl) phosphate (BBOEP), bis(2-chloroethyl) phosphate (BCEP), bis(1-chloro-2-propyl) phosphate (BCPP) and bis(1,3-dichloro-2-propyl) phosphate (BDCIPP). Separation was achieved in less than 3 min on a short column with narrow diameter and small particle size (50 mm × 2.1 mm × 1.7 μm). Different mobile phases were explored to obtain optimal sensitivity. Acetonitrile/water buffered with 5 mM of ammonium hydroxide/ammonium formate (pH 9.2) was the preferred mobile phase. Quantification of DAPs was performed using deuterated analogues as internal standards in synthetic urine (averaged DAP accuracy was 101%; RSD 3%). Low method limits of quantification (MLQ) were obtained for DNBP (0.40 ng mL−1), DPHP (0.10 ng mL−1), BDCIPP (0.40 ng mL−1) and BBOEP (0.60 ng mL−1), but not for the most polar DAPs, BCEP (∼12 ng mL−1) and BCPP (∼25 ng mL−1). The feasibility of the method was tested on 84 morning urine samples from 42 mother and child pairs. Only DPHP was found above the MLQ in the urine samples with geometric mean (GM) concentrations of 1.1 ng mL−1 and 0.57 ng mL−1 for mothers and children respectively. BDCIPP was however, detected above the method limit of detection (MLD) with GM of 0.13 ng mL−1 and 0.20 ng mL−1. While occasionally detected, the GM of DNBP and BBOEP were below MLD in both groups.  相似文献   

14.
Eight naturally occurring capsaicinoids have been determined in Capsicum by use of high-purity standards, with norcapsaicin as an internal standard. The solid standards were rigorously checked for purity. The sensitivity of electrospray ionization (ESI), atmospheric-pressure chemical ionization (APCI), and coordination ion-spray (CIS; with silver) toward the capsaicinoids were measured and compared. The highest sensitivity was found for positive-ion ESI. Method validation of the liquid chromatography–ESI-mass spectrometry (LC–ESI-MS) determination is reported, including tests for repeatability (4%), detection limit (5 pg injected), linear range (20–6 ng injected), quantitation (excellent linearity; <2% relative standard deviation), and recovery (99–103%). The major and minor capsaicinoids in a commercial plant extract and in chili pepper fruits were quantified.Electronic Supplementary Material Supplementary material is available for this article at  相似文献   

15.
A simple, efficient, innovative and environmentally friendly analytical technique was successfully applied for the first time for the extraction and preconcentration of polybrominated diphenyl ethers (PBDEs) from water samples. The PBDEs selected for this work were those most commonly found in the literature in natural water samples: 2,2′,4,4′-tetraBDE (BDE-47), 2,2′,4,4,5-pentaBDE (BDE-99), 2,2′,4,4,6-pentaBDE (BDE-100) and 2,2,4,4′,5,5′-hexaBDE (BDE-153). The extracted PBDEs were separated and determined by gas chromatography–mass spectrometry (GC–MS). The extraction/preconcentration technique is based on ultrasound-assisted emulsification-microextraction (USAEME) of a water-immiscible solvent in an aqueous medium. Several variables including, solvent type, extraction time, extraction temperature and matrix modifiers were studied and optimized over the relative response the target analytes. Chloroform was used as extraction solvent in the USAEME technique. Under optimum conditions, the target analytes were quantitatively extracted achieving enrichment factors (EF) higher than 319. The detection limits (LODs) of the analytes for the preconcentration of 10 mL sample volume were within the range 1–2 pg mL−1. The relative standard deviations (RSD) for five replicates at 10 pg mL−1 concentration level were <10.3%. The calibration graphs were linear within the concentration range of 5–5000 pg mL−1 for BDE-47 and BDE-100; and 5–10,000 pg mL−1 for BDE-99 and BDE-153, respectively. The coefficients of estimation were ≥0.9985. Validation of the methodology was performed by standard addition method at two concentration levels (10 and 50 pg mL−1). Recovery values were ≥96%, which showed a successful robustness of the analytical methodology for determination of picogram per milliliter of PBDEs in water samples. Significant quantities of PBDEs were not found in the analyzed samples.  相似文献   

16.
A rapid, simple, and sensitive multiresidue method for analysis of 53 pesticides in fruit and vegetables by ultra-performance liquid chromatography (UPLC) coupled to triple-quadrupole tandem mass spectrometry (MS-MS) has been developed and validated. Prior to analysis, analytes were extracted by use of buffered QuEChERS (quick, easy, cheap, effective, rugged, safe) methodology without further cleanup for non fatty matrices. Chromatographic conditions were optimised in order to achieve a fast separation in multiple reaction monitoring (MRM) mode. Indeed, more than 50 pesticides can be separated in less then 10 min. Four common representative matrices (cucumber, orange, strawberry, and olive) were selected to investigate the effect of different matrices on recovery and precision. Mean recoveries ranged from 70 to 109% with relative standard deviations lower than 20% for all the pesticides assayed in the four selected matrices. The method has been applied to the analysis of 200 vegetable samples, and imidacloprid was the pesticide most frequently found, with concentrations ranging from 0.01 to 1.00 mg kg−1. This methodology combines the advantages of both QuEChERS and UPLC-MS-MS producing a very rapid, sensitive, and reliable procedure which can be applied in routine analytical laboratories.  相似文献   

17.
A new highly sensitive and rapid approach to the determination of 1,1-dimethylhydrazine in natural water is developed (determination range is 0.03–1 μg/L). It is based on the use of high-performance liquid chromatography–tandem mass spectrometry with precolumn derivatization by phenylglyoxal and does not require any preconcentration. Derivatization, chromatographic separation conditions, and tandem mass spectrometry detection parameters are chosen. Intra-day precision of the results of measurements of 1,1- dimethylhydrazine in natural water is 12–16%, and inter-day precision is 16–22%. The lowest limit of detection and the lowest limit of quantification are 0.010 μg/L and 0.030 μg/L, respectively.  相似文献   

18.
A simple, fast and sensitive liquid chromatography–electrospray tandem mass spectrometry method was established for trace levels of nine haloacetic acids (HAAs) in drinking water. Water samples were removed of residual chlorine by adding l-ascorbic acid, and directly injected after filtered by 0.22 μm membrane. Nine HAAs were separated by liquid chromatography in 7.5 min, and the limits of detection were generally between 0.16 and 0.99 μg/L except for chlorodibromoacetic acid (1.44 μg/L) and tribromoacetic acid (8.87 μg/L). The mean recoveries of nine target compounds in spiked drinking water samples were 80.1–108%, and no apparent signal suppression was observed. Finally, this method was applied to determine HAAs in the tap water samples collected from five waterworks in Shandong, China. Nine HAAs except for monochloroacetic acid, monobromoacetic acid, dibromochloroacetic acid and tribromoacetic acid were detected, and the total concentrations were 7.79–36.5 μg/L. The determination results well met the first stage of the Disinfectants/Disinfection By-Products (D/DBP) Rules established by U.S.EPA and Guidelines for Drinking-water Quality of WHO.  相似文献   

19.
A sensitive and selective liquid chromatographic–tandem mass spectrometric (LC–MS–MS) method was developed to determine pantoprazole sodium (PNT) in human urine. After solid-phase extraction with SPE cartridge, the urine sample was analysed on a C18 column (symmetry 3.5 μm; 75 mm × 4.6 mm i.d) interfaced with a triple quadrupole tandem mass spectrometer. Positive electrospray ionization was employed as the ionization source. The mobile phase consisted of acetonitrile–water (90:10, v/v). The method was linear over a concentration range of 1–100 ng mL?1. The lower limit of quantitation was 1 ng mL?1. The intra-day and inter-day relative standard deviation across three validation runs over the entire concentration range was <10.5%. The accuracy determined at three concentrations (8.0, 50.0 and 85.0 ng mL?1 PNT) was within ±1.25% in terms of relative errors.  相似文献   

20.
A sensitive method has been developed and validated for the determination of diverse groups of pharmaceuticals, steroid hormones, and hormone-like personal care products in sewage sludge. Samples were extracted by ultrasonic-assisted extraction followed by solid-phase extraction cleanup. For determination of estrogens and hormone-like phenolic compounds, sample extracts were further derivatized with dansyl chloride and purified with silica gel column chromatography to improve the analytical sensitivity. The chemicals were determined by ultra-high-performance liquid chromatography–tandem mass spectrometry (UHPLC-MS/MS) in multiple-reaction monitoring mode. Recoveries ranged mostly from 63% to 119% with relative standard deviations within 15%. Method quantification limits were 0.1–3 ng g−1 dry weight (dw) for sewage sludge. The method was applied to a preliminary investigation of pharmaceuticals and personal care products (PPCPs) in sewage sludge and sediment in the Pearl River Delta, South China. Triclosan, triclocarban, 2-phenylphenol, bisphenol A, and parabens were ubiquitously detected at 3.6–5088.2 ng g−1 dw in sludge and 0.29–113.1 ng g−1 dw in sediment samples, respectively. Estrone, carbamazepine, metoprolol, and propranolol were also frequently quantified in the sludge and sediment samples. The dewatering process caused no significant losses of these PPCPs in sewage sludge.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号