首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A rapid, accurate and sensitive method for simultaneous determination of 15 steroidal hormones including four estrogens (estrone, 17β-estradiol, 17α-ethynylestradiol, estriol) and eleven progestogens (17β-estradiol-3-benzoate, 19-norethindrone, gestodene, levonorgestrel, medroxyprogesterone, cyproterone acetate, megestrol-17-acetate, progesterone, norethindrone acetate, chlormadinone-17-acetate, and hydroxy progesterone caproate) in environmental waters was developed by coupling solid-phase disk extraction (SPDE) to ultra performance liquid chromatography–tandem mass spectrometry (UPLC–MS/MS) with electrospray ionization. Among three types of extraction tested (C8 SPDE, C18 SPDE and C18 SPE), the most satisfactory result was achieved using C18 SPDE for its satisfactory recovery (75.6 to 101.4%) and short extraction time (15 min for 1 L deionised water). The validity of this method was investigated and good analytical performance for all the analytes was obtained, including low limits of method detection (0.5–3.4 ng/L) and excellent linear dynamic range (1.0–50.0 ng/L). The method was applied to determine the steroidal hormones in 10 environmental waters including tap water, river water, lake water and waste water in Beijing. No progestogen was detected in all samples and estrone, estriol, 17α-ethynylestradiol were found in most samples at levels between 1.8 and 127.9 ng/L.  相似文献   

2.
We report a column-switching liquid chromatography (LC) tandem mass spectrometry (MS/MS) method for highly sensitive determination of both free estrogens (estrone, estradiol, and estriol) and their conjugates (estrone-3-sulfate, estradiol-3-sulfate, estriol-3-sulfate, estrone-3-glucuronide, estradiol-3-glucuronide, estriol-16-glucuronide, and estriol-3-glucuronide) in river water. This technique combines reversed phase (RP) chromatographic separation of the dansyl chloride derivatized free estrogens and hydrophilic interaction liquid chromatographic (HILIC) separation of the estrogen conjugates with multiple reaction monitoring (MRM). Using this new method, sensitivity increases 100- to 1000-fold for free estrogens and 2- to 10-fold for estrogen conjugates over RPLC-MS/MS alone. Method detection limits (MDL) range from 0.038 to 6.9 ng L−1 with accuracy of 68-105% and precision of 1.7-17%. We successfully used this method to analyze river water samples collected from the North Saskatchewan River at the same location and detected trace concentrations of estrone (0.042 ng L−1) and estrone-3-sulfate (0.84 ng L−1), demonstrating the application of this method for environmental analysis.  相似文献   

3.
A specific and sensitive multi-method based on liquid chromatography–tandem mass spectrometry using atmospheric pressure chemical ionization (LC–APCI–MS/MS) has been developed for the determination of 20 anabolic steroids in muscle tissue (diethylstilbestrol, β-estradiol, ethynylestradiol, α/β-boldenone, α/β-nortestosterone, methyltestosterone, β-trenbolone, triamcinolone acetonide, dexamethasone, flumethasone, α/β-zearalenol, α/β-zearalanol, zearalenone, melengestrol acetate, megestrol acetate and medroxyprogesterone acetate). The procedure involved hydrolysis, extraction with tert-butyl methyl ether, defattening and final clean-up with solid phase extraction (SPE) on Oasis HLB and Amino cartridges. The analytes were analyzed by reversed-phase LC–MS/MS, in positive and negative multiple reaction monitoring (MRM) mode, acquiring two diagnostic product ions from each of the chosen precursor ions for the unambiguous confirmation of the hormones. The method was validated at the validation level of 0.5 ng/g. The accuracy and precision of the method were satisfactory. The decision limits CCα ranged from 0.03 to 0.14 ng/g while the detection capabilities CCβ ranged from 0.05 to 0.24 ng/g. The developed method is sensitive and useful for detection, quantification and confirmation of these anabolic steroids in muscle tissue and can be used for residue control programs.  相似文献   

4.
Recent studies have shown that amphetamines and other drugs of abuse residues occur in wastewater. Consequently, several methods have been developed for their determination by solid-phase extraction (SPE) and liquid chromatography–tandem mass spectrometry (LC–MS/MS). However, a major drawback of these methods is the lack of selectivity during SPE that results in reduced sensitivity, due to matrix effects, and in some cases in low precision and poor accuracy. In order to tackle this problem, three different SPE alternatives have been evaluated in this work for the determination of five amphetamines: common hydrophilic balance (Oasis HLB), mixed-mode (Oasis MCX) and molecularly imprinted polymers (MIPs) sorbents. Among them, Oasis HLB showed the worst performance, as three amphetamines (MDA, MDMA and MDEA) could not be determined because of interfering signals in the LC–MS/MS chromatogram, and amphetamine recoveries could not be corrected by the use of the deuterated analogue internal standard. Oasis MCX permitted the determination of all target analytes, but with still strong signal suppression: ca. 70% signal drop with wastewater samples, which could in this case be corrected by the internal standards providing acceptable trueness (overall recoveries: 101–137%), precision (RSD: 2.0–12%) and limits of detection (LOD: 1.5–4.4 ng/L). Alternatively, MIPs rendered cleaner extracts with less matrix effects (ca. 30% signal drop), and thus lower LODs (0.5–2.7 ng/L) and even better trueness (91–114% overall recovery) and precision (1.5–4.4%RSD). The final application of the method with MIP cartridges showed the presence of MDA and MDMA in the seven analysed wastewaters at the 4–20 ng/L level.  相似文献   

5.
Amitriptyline, citalopram, fluoxetine, and fluvoxamine were isolated by electro membrane extraction (EME) from 70 μl of untreated plasma (pH 7.4), through a supported liquid membrane (SLM) of 1-ethyl-2-nitrobenzene immobilized in the pores of a porous polypropylene hollow fiber, and into 30 μl of 10 mM HCOOH as acceptor solution inside the lumen of the hollow fiber. The driving force of the extraction was a 9 V potential sustained over the SLM with a common battery, with the positive electrode placed in the plasma sample and the negative electrode placed in the acceptor solution. Extractions were performed under totally stagnant conditions with a very simple device for 1 min (kinetic regime), and subsequently the acceptor solution was analyzed directly by liquid chromatography–mass spectrometry (LC–MS). Recoveries were 12, 13, 22, and 17% for fluoxetine, amitriptyline, citalopram, and fluvoxamine, respectively. Sample clean-up was comparable to reversed-phase solid-phase extraction (SPE), but EME required substantially less time than SPE. The time advantage of EME was further improved by parallel extraction of three samples (for 1 min) with the same 9 V battery. EME from plasma combined with LC–MS provided limits of quantification (S/N = 10) in the range 0.4–2.3 ng/ml, linearity in the range 1–1000 ng/ml with r2-values of 0.998–0.999, and repeatability in the range 3.2–8.9% RSD in the mid-therapeutic window (100 ng/ml).  相似文献   

6.
A sensitive and specific method for the quantitative determination of zearalenone (ZEN) and its major metabolites (α-zearalenol (α-ZEL), β-zearalenol (β-ZEL), α-zearalanol (α-ZAL), β-zearalanol (β-ZAL) and zearalanone (ZAN)) in animal plasma using liquid chromatography combined with heated electrospray ionization (h-ESI) tandem mass spectrometry (LC–MS/MS) and high-resolution Orbitrap® mass spectrometry ((U)HPLC–HR–MS) is presented. The sample preparation was straightforward, and consisted of a deproteinization step using acetonitrile. Chromatography was performed on a Hypersil Gold column (50 mm × 2.1 mm i.d., dp: 1.9 μm, run-time: 10 min) using 0.01% acetic acid in water (A) and acetonitrile (B) as mobile phases.  相似文献   

7.
Different extraction methods, including extraction by organic solvents with and without acetic acid digestion, and mixed inorganic acid digestion coupled with solid phase extraction (SPE), were developed for the analysis of perfluorinated carboxylic acids (PFCAs) and perfluorooctanesulfonate (PFOS) in bivalve shells. The extracts were separated, identified and quantified by liquid chromatography–electrospray ionization–tandem mass spectrometry (LC–ESI–MS/MS). The method utilizing mixed acid digestion coupled with SPE performed more efficiently than other extraction methods. Matrix recoveries of the optimized methods ranged from 92% to 104%, with limits of detection of 0.05–0.43 ng/g. The optimized method was successfully applied to the analysis of PFCAs and PFOS in shell samples of two bivalves from Bohai Bay, China. PFCAs and PFOS concentrations in the shells ranged from 0.3 ng/g to 4.1 ng/g, 1–50 times lower than those in the soft tissues of bivalves for most target analytes. No relationship between PFCAs and PFOS in shells and in soft tissues was found; this is explained by the different contaminant uptake mechanism of shells and soft tissues.  相似文献   

8.
A direct aqueous SFE system designed to extract water samples contained in vials has been coupled on-line with a reverse phase LC–MS–MS system using a single 10-port valve. An SFE trap system using C1 stationary phase connected to a C18 analytical HPLC column enabled the SFE–LC–MS–MS analysis of three polyether ionophore antibiotics in water using a step gradient. A quantitative SFE–LC–MS–MS method has been developed whereby the progress of SFE can be monitored directly on-line such that ionophore recovery profile data from a single water sample can be obtained. Using a continuous direct aqueous SFE period of 75 min, the SFE–LC–MS–MS recoveries of the ionophores were: monensin 76.2% with RSD 4.1%, lasalocid 84.6% with RSD 3.8% and narasin 91.2% with RSD 3.2%. With positive ion electrospray ionization, the SFE–LC–MS–MS system using a 4 mL water sample provided multiple reaction monitoring (MRM) limits of detection for monensin and lasalocid each equivalent to 90 ng/L whereas 30 ng/L for narasin. A two-way valve controlling carbon dioxide distribution to the SFE vessel has provided a means for the initial investigation of the recovery of ionophore sodium salts from water using static SFE.  相似文献   

9.
A solid-phase extraction (SPE) method for the enrichment and clean-up of lipophilic marine biotoxins from extracts of different species of bivalve molluscs and processed shellfish products was developed. Okadaic acid (OA), pectenotoxin2 (PTX2), azaspiracid1 (AZA1) and yessotoxin (YTX) were determined by LC–MS/MS in hydrolyzed and non-hydrolyzed extracts. Applying a concentration factor of 10 the limit of quantification for the four toxins was determined to be 1 μg/kg. An organized in-house ring trial proved transferability of the method protocol and satisfactory results for all four toxins with a relative standard deviation (RSD) of 5–12%. The precision of the whole method including LC–MS detection was determined by processing seven independent extractions analyzed in independent sequences. RSD ranged between 12% and 24%. This SPE method was tested within a concentration range corresponding to the range of the current European Union regulatory limits (up to 160 μg/kg for the OA group), but it would also be applicable to a lower μg/kg range which is important in view of a possible decrease of regulatory limits as proposed by a working group of the European Food Safety Authority. The potential of SPE as a cleaning tool to cope with matrix effects in LC–MS/MS was studied and compared to liquid–liquid portioning.  相似文献   

10.
Pollutants such as human pharmaceuticals and synthetic hormones that are not covered by environmental legislation have increasingly become important emerging aquatic contaminants. This paper reports the development of a sensitive and selective multi-residue method for simultaneous determination and quantification of 23 pharmaceuticals and synthetic hormones from different therapeutic classes in water samples. Target pharmaceuticals include anti-diabetic, antihypertensive, hypolipidemic agents, β2-adrenergic receptor agonist, antihistamine, analgesic and sex hormones. The developed method is based on solid phase extraction (SPE) followed by instrumental analysis using liquid chromatography-electrospray ionization-tandem mass spectrometry (LC–ESI-MS/MS) with 30 min total run time. River water samples (150 mL) and (sewage treatment plant) STP effluents (100 mL) adjusted to pH 2, were loaded into MCX (3 cm3, 60 mg) cartridge and eluted with four different reagents for maximum recovery. Quantification was achieved by using eight isotopically labeled internal standards (I.S.) that effectively correct for losses during sample preparation and matrix effects during LC–ESI-MS/MS analysis. Good recoveries higher than 70% were obtained for most of target analytes in all matrices. Method detection limit (MDL) ranged from 0.2 to 281 ng/L. The developed method was applied to determine the levels of target analytes in various samples, including river water and STP effluents. Among the tested emerging pollutants, chlorothiazide was found at the highest level, with concentrations reaching up to 865 ng/L in STP effluent, and 182 ng/L in river water.  相似文献   

11.
Quantitation of trace levels of domoic acid (DA) in seawater samples usually requires labour-intensive protocols involving chemical derivatization with 9-fluorenylmethylchloroformate and liquid chromatography with fluorescence detection (FMOC–LC–FLD). Procedures based on LC–MS have been published, but time-consuming and costly solid-phase extraction pre-concentration steps are required to achieve suitable detection limits. This paper describes an alternative, simple and inexpensive LC method with ultraviolet detection (LC–UVD) for the routine analysis of trace levels of DA in seawater without the use of sample pre-concentration or derivatization steps. Qualitative confirmation of DA identity in dubious samples can be achieved by mass spectrometry (LC–MS) using the same chromatographic conditions. Addition of an ion-pairing/acidifying agent (0.15% trifluoroacetic acid) to sample extracts and the use of a gradient elution permitted the direct analysis of large sample volumes (100 μl), resulting in both high selectivity and sensitivity (limit of detection = 42 pg ml−1 by LC–UVD and 15 pg ml−1 by LC–MS). Same-day precision varied between 0.4 and 5%, depending on the detection method and DA concentration. Mean recoveries of spiked DA in seawater by LC–UVD were 98.8% at 0.1–10 ng ml−1 and 99.8% at 50–1000 ng ml−1. LC–UVD exhibited strong correlation with FMOC–LC–FLD during inter-laboratory analysis of Pseudo-nitzschia multiseries cultures containing 60–2000 ng DA ml−1 (r2 > 0.99), but more variable results were obtained by LC–MS (r2 = 0.85). This new technique was used to confirm the presence of trace DA levels in low-toxicity Pseudo-nitzschia spp. isolates (0.2–1.6 ng ml−1) and in whole-water field samples (0.3–5.8 ng ml−1), even in the absence of detectable Pseudo-nitzschia spp. cells in the water column.  相似文献   

12.
An ultra-high-pressure liquid chromatography–tandem mass spectrometry (UHPLC–MS/MS) method has been developed for the simultaneous quantification and confirmation of 11 basic/acidic illicit drugs and relevant metabolites in surface and urban wastewater at ng/L levels. The sample pre-treatment consisted of a solid-phase extraction using Oasis MCX cartridges. Analyte deuterated compounds were used as surrogate internal standards (except for norbenzoylecgonine and norcocaine) to compensate for possible errors resulting from matrix effects and those associated to the sample preparation procedure. After SPE enrichment, the selected drugs were separated within 6 min under UHPLC optimized conditions. To efficiently combine UHPLC with MS/MS, a fast-acquisition triple quadrupole mass analyzer (TQD from Waters) in positive-ion mode (ESI+) was used. The excellent selectivity and sensitivity of the TQD analyzer in selected reaction monitoring mode allowed quantification and reliable identification at the LOQ levels. Satisfactory recoveries (70–120%) and precision (RSD < 20%) were obtained for most compounds in different types of water samples, spiked at two concentration levels [limit of quantification (LOQ) and 10LOQ]. Thus, surface water was spiked at 30 ng/L and 300 ng/L (amphetamine and amphetamine-like stimulants), 10 ng/L and 100 ng/L (cocaine and its metabolites), 300 ng/L and 3000 ng/L (tetrahydrocannabinol-COOH). Recovery experiments in effluent and influent wastewater were performed at spiking levels of three and fifteen times higher than the levels spiked in surface water, respectively. The validated method was applied to urban wastewater samples (influent and effluent). The acquisition of three selected reaction monitoring transitions per analyte allowed positive findings to be confirmed by accomplishment of ion ratios between the quantification transition and two additional specific confirmation transitions. In general, drug consumption increased in the weekends and during an important musical event. The highest concentration levels were 27.5 μg/L and 10.5 μg/L, which corresponded to 3,4-methylenedioxymethamphetamine (MDMA, or ecstasy) and to benzoylecgonine (a cocaine metabolite), respectively. The wastewater treatment plants showed good removal efficiency (>99%) for low levels of illicit drugs in water, but some difficulties were observed when high drug levels were present in wastewaters.  相似文献   

13.
A method using high performance liquid chromatography–electrospray tandem mass spectrometry (LC–ESI-MS/MS) in positive ion mode was developed for the simultaneous analysis of 30 phenolic compounds, including four estrogens, bisphenol A (BPA), 10 hydroxylated polybrominated dephenyl ethers (OH-PBDEs) and 15 bromophenols (BRPs), in blood plasma. In the present method, derivatization with dansyl chloride was employed, and all the derivertized target compounds were well resolved on a 100 mm Xbridge C18 column with acetonitrile and 0.1% formic acid as the mobile phases. Purification procedures, such as liquid–liquid extraction and silica-gel chromatography, were applied to reduce matrix effects in the sample extract and remove excess derivatizing reagents, thus permitting selective and sensitive detection of the target phenolic compounds. The limit of quantification for all analytes, with a signal-to-noise ratio of ∼10, was 2–30 pg/g (plasma weight) except for 6-OH-BDE-137 (30 pg/g) and 3-BRP (60 pg/g). The method was validated for recoveries (68–100%), accuracy (84–110%) and precision (3.7–11%) using charcoal-stripped bovine blood plasma spiked with all target compounds (500 and 5000 pg/mL). Finally, the method was applied to analyze six blood plasma samples from frogs and cormorants, where two natural estrogens, one BPA, one OH-PBDE and four BRPs were detected. The greatest total concentrations of estrogens coincided with the least total concentrations of other phenolic compounds for both species. The proposed method based on derivatization followed by LC–MS/MS provides a novel method to simultaneously monitor multiple groups of phenolic compounds in blood plasma.  相似文献   

14.
This paper describes the development of an optimized method based on solid-phase extraction (SPE) followed by liquid chromatography–electrospray ionization tandem mass spectrometry (LC–MS/MS) for the simultaneous analysis of ten antibiotic compounds including tetracyclines, sulfonamides, macrolides and quinolones. LC–MS/MS sensitivity has been optimized by alterations to both LC and MS operations. Of the two high resolution columns tested, Waters Symmetry C18 endcapped and Agilent Zorbax Bonus-RP, the latter was found to show better performance in producing sharp peaks and clear separation for most of the target compounds. Optimization of the MS fragmentation collision and cone energy enhanced the peak areas of the target analytes. The recovery of the target compounds from water samples was most efficient on Waters Oasis HLB SPE cartridge, while methanol was shown to be the most suitable solvent for desorbing the compounds from SPE. In addition, acidification of samples prior to SPE was shown to enhance the recovery of the compounds. To ensure a satisfactory recovery, the flow rate through SPE should be maintained at ≤10 mL min−1. The method was successfully applied to the analysis of antibiotics from environmental water samples, with concentrations being <LOD in tap water, between <LOD to 28 ng L−1 in river water and between <LOD to 230 ng L−1 in sewage effluent.  相似文献   

15.
Detection of mycotoxin biomarkers in urine of humans and animals provides a direct approach for assessing exposure to these mycotoxins as opposed to the indirect approach of food analysis, which in most cases is affected by the heterogeneity of the toxin in the food samples. Seven (7) mycotoxins and their metabolites (total 18 analytes) were selected and an LC–MS/MS method for their determination in human urine was developed and validated. The method consisted of direct analysis of two mycotoxin conjugates, deoxynivalenol-glucuronide and zearalenone-glucuronide without beta glucuronidase digestion of the urine samples. Since high method sensitivity is of utmost importance in such study, critical factors which could improve the analyte recovery and method sensitivity were investigated by a D-optimal experimental design. Urine samples (10 mL) were first extracted with 15 mL ethyl acetate/formic acid (99/1, v/v) followed by SAX SPE clean-up of the acidified aqueous fraction. Both extracts were combined and analyzed using an LC–MS/MS system operated in the positive ionization mode. A total run time of 28 min was adopted with all the 18 analytes eluting within 15 min.  相似文献   

16.
Using triacontyl bonded silica (C30) as on-line solid-phase extraction (SPE) material and a specially designed on-line analytical system which allowed large sample volume injection, a high speed and robust on-line SPE-HPLC–MS method was established for the analysis of five estrogens and bisphenol A (BPA) in milk samples. The milk sample is pretreated with acetonitrile for protein precipitation and then treated with primary secondary amine for the removal of polar impurities in the matrix. Then the pretreated sample can be automatically loaded by a LC pump. For effective extraction, an offshoot with NH4Ac solution of high-flow rate was employed to dilute the loaded sample by a mixing tee before sample was loaded onto the C30 extraction column. In this way, large volume injection (1 mL in this experiment) could be achieved. Some important parameters such as sample loading flow rate, sample dilution ratio and injection volume were optimized. Under the optimized conditions, the recoveries for all analytes range from 71.4 to 97.1% and reproducibility represented as RSDs are less than 15.0% (n = 5) with milk samples spiked at 0.6 and 15 ng/mL of each analyte. To the authors’ knowledge, it constitutes the first work describing a C30 on-line SPE-LC–MS analytical method for the screen and monitoring of these estrogens and BPA in milk.  相似文献   

17.
Complementary methods using liquid chromatography–tandem quadrupole mass spectrometry (LC–MS/MS) and comprehensive two-dimensional gas chromatography–time-of-flight mass spectrometry (GC × GC–TOF-MS) were developed and applied to determine targeted metabolites involved in central carbon metabolism [including tricarboxylic acid cycle, serine cycle, ethylmalonyl-coenzyme A (ethylmalonyl-CoA) pathway and poly-β-hydroxybutyrate cycle] of the bacterium Methylobacterium extorquens AM1 grown on two carbon sources, ethylamine (C2) and succinate (C4). Nucleotides, acyl-CoAs and a few volatile metabolites in cell extracts of M. extorquens AM1 were readily separated using either hydrophilic interaction liquid chromatography or reversed-phase liquid chromatography, and detected with good sensitivity by MS/MS. However, volatile intermediates within a low mass range (<300 m/z), especially at low abundance (such as glyoxylic acid and others <500 nM), were more effectively analyzed by GC × GC–TOF-MS which often provided better sensitivity, resolution and reproducibility. The complementary nature of the LC-based and GC-based methods allowed the comparison of 39 metabolite concentrations (the lowest level was at 139.3 nM). The overlap between the LC-based and GC-based methods of seven metabolites provided a basis to check for consistency between the two methods, and thus provided some validation of the quantification accuracy. The abundance change of 20 intermediates further suggested differences in pathways linked to C2 and C4 metabolism.  相似文献   

18.
A solid-phase extraction (SPE) LC–MS/MS method for 18 commercial drugs in secondary wastewater and product water from water recycling plants using microfiltration (MF) and reverse osmosis (RO) has been developed, optimised and validated. The method incorporates a range of multi-class pharmaceuticals including lipid lowering agents, analgesics, antipyretics, non-steroidal anti-inflammatory drugs, antidepressants, anticoagulants, tranquilizers, cytostatic agents, and antiepileptics. Method limits of quantitation (MLQs) in secondary wastewater ranged from 15 to 250 ng/L, while MLQs in post-RO water ranged from 1 to 25 ng/L. Results from analysis of secondary wastewater from Western Australia are presented, and represent the largest survey of non-antibiotic pharmaceuticals within Australia to date. Analysis of post-RO water from two MF/RO water recycling facilities also demonstrate that MF/RO treatment removes most pharmaceuticals to below the analytical limits of detection, and more importantly, up to seven orders of magnitude below health-based guideline values.  相似文献   

19.
In this work a LC–MS/MS method for the determination of two quaternary ammonium growth regulators (chlormequat and mepiquat) in food is reported. The separation was based on hydrophilic interaction liquid chromatography (HILIC) without the use of ion-pair reagents. A gradient elution of acetonitrile and formic acid/ammonium formate buffer from 60 to 40% acetonitrile was enough to achieve a resolution >1.5 in less than 4.0 min. The HILIC system was coupled to a triple quadrupole mass spectrometer equipped with a heated electrospray probe (H-ESI) providing sub-pg LODs in SRM mode. A straightforward sample treatment (SPE C18 clean-up) was enough to provide MLODs at low ppb levels when analysing a range of food samples that covered different kinds of matrices such as fresh fruit, vegetables, fruit juices, baby food, bread, coffee and beer. Chlormequat was found in seven samples (0.8–126 ng/g) but mepiquat was only detected in bread and coffee samples (0.9–166 ng/g).  相似文献   

20.
A specific and sensitive method based on liquid chromatography–tandem mass spectrometry using atmospheric pressure chemical ionization (LC–APCI–MS/MS) has been developed for the determination of gestagens in kidney fat (medroxyprogesterone acetate, megestrol acetate and melengestrol acetate). The procedure involved a clean-up procedure with gel permeation chromatography (GPC). The analytes were analyzed by reversed-phase LC–MS/MS, in positive multiple reaction monitoring (MRM) mode, acquiring two diagnostic product ions from the chosen precursor for the unambiguous confirmation of the gestagens. The method was validated at the validation level of 1.0 ng/g. The accuracy and precision of the method were satisfactory. The decision limits CCα ranged from 0.20 to 0.22 ng/g while the detection capabilities CCβ ranged from 0.33 to 0.38 ng/g. The method proved to be sensitive and reliable and thus renders an appropriate mean for residue analysis studies.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号