首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Separation and simultaneous determination of a number of organic acid anions (oxalate, mellitate, trimellitate and benzoate) and U(VI) with direct UV detection is developed for analysis of uranium carbide (UC) dissolution products by capillary zone electrophoresis (CZE). Reverse polarity mode is used. It is found that complex formation of U(VI) with carbonate, used as a carrier electrolyte, allows U(VI) to be determined, as negatively charged species, in a single run with organic acid anions. Some parameters such as pH value, composition of electrolyte and detection wavelength are optimized. Under the chosen conditions (carbonate buffer (ionic strength of 100 mM), pH 9.8, 0.15 mM tetradecyltrimethylammonium bromide (TTAB)) a complete separation is achieved. Calibration plots are linear in two ranges of concentration for U(VI) (∼1 × 10−5 to 1 × 10−3), mellitate and trimellitate (∼5 × 10−6 to 5 × 10−4), and about one range (∼1 × 10−4 to 5 × 10−3) for oxalate and benzoate. Accuracy of the procedure is checked by the “added-found” method in standard mixture solutions. Relative standard deviation is within the range of 2–10% and the recovery is in the range of 90–110%. This method is applied for the analysis of real UC dissolution samples.  相似文献   

2.
Summary Four parabens (esters of 4-hydroxybenzoic acid), effective preservatives against the growth of bacteria, yeast, and mold in numerous industrial products, have been used in this work as model compounds to demonstrate the resolving power of capillary electrophoresis (CE). The simultaneous determination of methyl-(MP), ethyl-(EP), propyl-(PP), and butylparaben (BP) was achieved by capillary zone electrophoresis (CZE) with UV diode-array detection at 294 nm. When run voltage, temperature, and electrolyte concentration and pH were optimized the most effective separation was achieved within 7 min by use of 50 cm (effective length) fused silica capillary tubing and operation at 25kV and 20°C. Background electrolyte comprising 35 mM tetraborate buffer adjusted to pH 10.0 gave the best results. The limits of detection of the optimized method ranged from 0.65 μg mL−1 for BP to 0.81 μg mL−1 for MP; the relative standard deviation was between 0.35 and 0.50%. These results showed that the method enables the determination of the four parabens in commerially available cosmetic and pharmaceutical preparations containing some of the parabens and in an unidentified canned berry fruit juice.  相似文献   

3.
An alternative methodology for simultaneous analysis of ethambutol, isoniazid, rifampicin and pyrazinamide in pharmaceutical formulations by capillary zone electrophoresis under UV direct detection with an analysis time of 8.0 min is proposed. Background running was based on the effective mobility curve of the analytes and an optimum separation condition was achieved using a 33 Box-Behnken design, with Brij 35, Cu2+ and acetic acid/sodium acetate buffer as factors. An electrolyte consisting of 50.0 mmol L−1 of acetic acid/sodium acetate buffer, 12.5 mmol L−1 of CuSO4, and standard and sample solutions prepared in 2.00 mmol L−1 of Brij 35 and 12.5 mmol L−1 of CuSO4 were optimized. After evaluating validation parameters, the method was successfully applied to the analysis of samples in the form of tablets and sachets.  相似文献   

4.
In general capillary zone electrophoresis (CZE) separation models, o‐, m‐, and p‐phenylenediamine isomers can be separated in a weak acidic running buffer for their pKa values being 4.52, 5.64, 6.04, respectively, while o‐, m‐, and p‐dihydroxybenzene isomers can be separated in a weak basic buffer for their pKa values being 9.40, 9.40 and 10.04, respectively. So, it is hard to find a suitable running buffer at a fixed pH in normal CZE for simultaneous separation of these two groups of positional isomers. In this paper, a novel method based on alternately running two different pH buffers in CZE coupled with amperometric detection (CZE‐AD) was designed to simultaneously determine these two groups of positional isomers. It is found that when two different pH running buffers were employed alternately under appropriate order and time, the six analytes could be separated perfectly in less than 20 min and the detection limits were as low as 10–7 mol/L. Furthermore, the effects of working electrode potential, pH and concentration of running buffer, separation voltage and injection time on CZE–AD were investigated. Experimental results demonstrated that the introduced method was practical to simultaneously determine two groups of positional isomers with different pKa and had some advantages of high sensitivity, good repeatability and small sample requirement.  相似文献   

5.
This study demonstrates the separation of active ingredients in acne formulations (salicylic acid, cloramphenicol and resorcinol in presence of azulene) by capillary zone electrophoresis. Factors affecting their separations were the buffer pH and concentration, applied voltage, sample preparation, and presence of additives. Optimun results were obtained with a 50 mM sodium tetraborate-50 mM sodium phosphate, pH 9.0. The carrier electrolyte gave baseline separation with good resolution, short migration times (<6 min), great reproducibility and accuracy. Calibration plots were linear over at least three orders of magnitude of analyte concentrations, the lower limits of detection being within the range 0.39-1.25 μg ml−1. The procedure was fast and reliable and commercial pharmaceuticals could be analysed without prior sample clean-up procedure.  相似文献   

6.
Zhang S  Dong S  Chi L  He P  Wang Q  Fang Y 《Talanta》2008,76(4):780-784
Despite the separation efficiency of capillary electrophoresis (CE) is much higher than other chromatographic methods, it is sometimes difficult to perfectly separate the complex ingredients in biological samples. One possible and simple way to develop the separation effect in CE is to add some modifiers in the running buffer. In this paper, the suitable running buffer modifiers were explored to simultaneously separate and detect six typical flavonoids (apigenin, luteolin, kaempferol, quercetin, (+)-catechin and (−)-epicatechin) which are the main active ingredients in chrysanthemum by capillary zone electrophoresis with amperometric detection (CZE-AD). It was found that when β-cyclodextrin (β-CD) and the mixture of methanol and ethanol were used as running buffer modifiers, a baseline separation of the six analytes could be accomplished in less than 20 min and the detection limits were as low as 10−7 or 10−8 g ml−1. Other factors affecting the CZE separation, such as working potential, pH value and ionic strength of running buffer, separation voltage and sample injection time were extensively investigated. Under the optimum conditions, a successful practical application on the determination of chrysanthemum samples confirmed the validity and practicability of this method.  相似文献   

7.
Simultaneous determination of alcohols, amines, amino acids, flavonoids, and purine and pyrimidine bases in bottled beer samples directly without any pre-treatment was carried out by capillary zone electrophoresis with diode-array detection. Electrolyte conditions such as pH, composition and concentration of the buffer, working voltage and type and time of injection were checked. The best separation of the cited analytes was achieved in 70 mM sodium borate solution and pH 10.25. The detection limits were from 2.1 to 5.6 mg L–1 for the 18 compounds studied. The developed method is rapid, sensitive and quantitative and has been applied to seven types of international bottled beers of different origins bought locally.  相似文献   

8.
In this work, for the first time, capillary zone electrophoresis (CZE) technique combined with microwave-assisted extraction (MAE) was developed for the fast quantification of chlorogenic acid (CA) in tobacco residues. CA in tobacco residue samples were extracted by MAE technique, and then analyzed by CZE. As a new sample preparation method for tobacco residues, the MAE procedure is optimized, validated and compared with conventional methods including ultrasonic extraction (USE) and reflux extraction (RE). It is found that MAE gives the best result due to the highest extraction efficiency within shortest extraction time (only 4.0 min). Here, CA is determined by CZE based on the calibration curve of its authentic standard. The method linearity, detection limit, precision and recovery are studied. The results show that the combined MAE and CZE method has a linearity (R2 0.991, 0.003-0.5 mg ml−1), a limit of detection (0.003 mg ml−1), a limit of quantification (0.01 mg ml−1), good precision (R.S.D. = 4.28%) and a finer recovery (89.0%). The proposed method was successfully applied to the analysis of CA in tobacco residue samples. The experiment results have demonstrated that the CZE combined with MAE is a convenient, fast, economical and reliable method for the determination of CA in tobacco residues.  相似文献   

9.
A capillary zone electrophoresis method was established for stability study of metformin (MET). MET and cyanoguanidine (CGN; a major degradation product) were well separated (with a resolution of 38.9) in 40 mM citrate buffer (pH 6.7) using a fused‐silica capillary with an effective length of 60 cm and an inner diameter of 50 μm, injection at 50 mbar for 5 s at 30°C with an applied voltage of 15 kV and diode array detection at 214 nm. Method validation showed good linearity (r2 > 0.99), precision (%RSDs < 1.98%), and accuracy (%recovery between 98.3 and 100.9%). Limits of detection and quantification were <30 and 100 μg/mL, respectively. The method was robust upon alteration of pH and voltage (%RSDs < 1.99%). Stability profiles of metformin from 11 stress conditions and the degradation kinetics could be established, using the simple capillary zone electrophoresis system. A mechanism for the degradation of MET was also proposed. MET was stable in neutral hydrolysis, but degraded under alkaline hydrolysis and oxidation. Under both conditions, CGN was quantified as the degradation product. An assay of MET in raw material and tablets showed that content of the drugs in all samples met the requirements of pharmacopeias and CGN was not detected.  相似文献   

10.
A simple and rapid capillary electrophoretic method was developed for the simultaneous determination of noradrenaline (NA) and dopamine (DA) in Portulaca oleracea L. The buffer solution used in this method was 40 mM tris (hydroxymethyl) aminomethane (Tris)-H3PO4 at pH 2.00 containing 15% methanol. The effects of pH value, organic modifier, and applied voltage were investigated. The linear ranges of NA and DA were 0.5-100 microg/mL (r=0.9952) and 6.25-200 microg/mL (r=0.9992), respectively. The relative standard deviations of the corrected peak area were 6.73% and 4.26%, respectively. NA and DA in Portulaca oleracea L. were simultaneous determined successfully within 5.6 min. In this way, the contents of NA and DA in different parts (stem, leaves, and seeds) of P. oleracea L. and in different extracts of leaves with different solvents (distilled water, 50% methanol, and methanol) were studied.  相似文献   

11.
Gong YX  Li SP  Wang YT  Li P  Yang FQ 《Electrophoresis》2005,26(9):1778-1782
Rhubarb, a well-known Chinese herbal medicine, is also used in Europe and other places of the world. Anthraquinones derivatives are thought to be the major active components. A pressurized liquid extraction (PLE) and capillary zone electrophoresis (CZE) separation were developed for simultaneous determination of five anthraquinones including aloe-emodin, emodin, chrysophanol, physcion, and rhein in Rhubarb. The effects of the experimental variables on PLE and CZE have been optimized. The optimum conditions of PLE were: solvent, methanol; temperature, 140 degrees C; particle size, 0.13-0.2 mm; static extraction time, 5 min; pressure, 1500 psi; and one extraction. The best separation of the five anthraquinones could be obtained using 50 mM borate buffer (pH 8.2) containing 25% isopropyl alcohol and 25% acetontrile as modifier, while the separation voltage was 25 kV and the temperature was at 20 degrees C. The method developed is accurate, simple, and reproducible, and could be used for quality control of Rhubarb and its medical preparations.  相似文献   

12.
A simple and rapid CZE method was established for the simultaneous determination of valienamine, acarbose and validamycin A, using a 20‐kV CZE with the detection wavelength of 193 nm and 50 mM phosphoric acid–20 mM Tris (pH 5.3) as a running buffer. The calibration curves of valienamine, acarbose, and validamycin A showed a good linear relationship at a concentration range of 5–1000 μg/mL. The detection limits of valienamine, acarbose, and validamycin A were 0.3, 0.6, and 0.6 μg/mL, respectively, and the average recoveries of each of the above were 99.9, 99.5, and 100.3%. The method has been successfully applied for simultaneous determination of substrate and product in the process of preparation of valienamine.  相似文献   

13.
The aim of this study was to develop a novel, sensitive, precise, simple, and rapid capillary zone electrophoresis method for the quality control of spironolactone in three different formulation types and a rapid simultaneous determination of the content of spironolactone and canrenone in urine samples using fluocinonide as an internal standard. After optimization of separation conditions, the electrolyte solution was the pH 5.5, 20 mM phosphate buffer containing 4.5 g/L sulfated‐β‐cyclodextrin, 15 kV of electric filed across the capillary applied at 25°C. A diode array detector was used, and the detection wavelength was 260 nm. Under optimum conditions, good linearity was achieved with correlation coefficients from 0.9976 to 0.9997. Detection limits were 0.56 and 0.20 μg/mL, and the quantitation limits were 1.87 and 0.67 μg/mL, respectively. Excellent accuracy and precision were obtained. Recoveries of the analytes varied from 100.8 to 103.1%. The results indicated that baseline separation of analytes was obtained and this method was suitable for quantitative determination of spironolactone in pharmaceutical preparations and rapid simultaneous determination of the content of spironolactone and its major metabolite canrenone in urine samples.  相似文献   

14.
高效毛细管区带电泳法快速测定尿液中的肌酐   总被引:1,自引:0,他引:1  
建立了一种快速测定尿中肌酐浓度的高效毛细管电泳方法。利用非涂层石英毛细管(64.5 cm×50μm i.d),以pH 2.5,0.1 mmol/L H3PO4作为电泳缓冲液,检测波长191 nm,用0.05 Pa压力进样4 s,在电压16 kV快速分离尿液中的肌酐,采用外标法定量。肌酐的迁移时间约为5.5 min,肌酐浓度在34.5~8840μmol/L范围内呈良好的线性(r2=0.999)。平均日内精密度为2.5%,日间精密度为3.0%。回收率94.1%~99.0%。与全自动生化分析仪碱性苦味酸速率法相比有良好的相关性(r=0.990,n=56)。高效毛细管电泳法测定尿肌酐可应用于临床样品的检测。  相似文献   

15.
Zhao-Yan Ren  Yan-Ping Shi 《Talanta》2009,78(3):959-801
A capillary zone electrophoresis method was developed for simultaneous determination of nine flavonoids, including two rare flavonols, in Tibetan medicine Anaphalis margaritacea. Baseline separation was performed at pH 9.6 with 25 mM Na2B4O7 and 10 mM NaH2PO4 buffer solution, 20 kV as driving voltage and 275 nm as detection wavelength. Repeatability tests showed that the R.S.D. of both intra- and inter-day migration times and peak areas were less than 5%. Recovery results ranged from 87.9% to 106.1%. Samples of A. margaritacea extracts were analyzed using the validated method, which is useful for its quality control.  相似文献   

16.
Tang Y  Wu M 《Talanta》2005,65(3):794-798
A method of quickly determining ascorbic acid and sorbic acid by capillary zone electrophoresis with ultraviolet detection was developed. The choice of background electrolyte, wavelength, injection time and applied voltage were discussed. Ascorbic acid and sorbic acid were well separated in 80 mmol L−1 boric acid-5 mmol L−1borax (pH = 8.0) in 5 min at the detecting wavelength of 270 nm. Under the optimum condition, the method has linear ranges of 2.54-352.00 mg L−1 for ascorbic acid and 1.08-336.39 mg L−1 for sorbic acid with the detection limit of 1.70 mg L−1 for ascorbic acid and 0.54 mg L−1 for sorbic acid, respectively. Other organic acids in fruit juices have no effect on the detection. This method is very feasible and simple and can be used to detect ascorbic acid and sorbic acid in fruit juices.  相似文献   

17.
A capillary zone electrophoresis method with UV detection was developed for the simultaneous detection and quantification of three tetracyclines in chicken meat samples: tetracycline (TC), oxytetracycline (OTC) and doxycycline (DOC). The separation conditions were: a running buffer containing 30 mM sodium phosphate, 2 mM EDTA disodium salt and 2.5% 2-propanol, pH 12.0, a 5 s hydrodynamic injection and a 14 kV separation voltage. Two different clean-up methodologies were employed: solid-phase extraction with C18 cartridges and ion exchange with Amberlite XAD7 resin. Analytes were detected at 360 nm in less than 12 min. LODs ranged from 61 μg kg−1 for OTC to 68 μg kg−1 for DOC with C18 cartridges, and 81 μg kg−1 for DOC to 89 μg kg−1 for TC with Amberlite XAD7 resin. The recoveries for TC, OTC and DOC obtained by both methods were between 85 and 95%, and the peak area repeatability for all of the samples was below 5% in all cases. Twenty-four samples of commercial chicken drumsticks were examined with both clean-up methodologies. In nine cases (37.5%) TC was detected, in a range from 197.8 to 2564.3 μg kg−1, and in seven cases (29.2%) OTC was detected in a range from 83.0 to 2049.3 μg kg−1. DOC was not detected in any of the tested samples. This method would be useful for the routine monitoring of TCs residues in poultry muscle.  相似文献   

18.
Summary The potential of capillary zone electrophoresis has been investigated for the separation and quantitative determination of some quinolone antibiotics. The influence of different conditions, such as the nature and concentration of the electrophoretic electrolyte, on migration time, peak symmetry, efficiency and resolution was studied. A buffer consisting of 100mm HEPES adjusted to pH 8.5 containing 10% (v/v) acetonitrile was found to furnish a very efficient and stable electrophoretic system for the separation of exoxacin, ciprofloxacin, ofloxacin, oxolinic acid, nalidixic acid and pipemedic acid. A linear relationship between concentration and peak area for each compound was obtained in the concentration range 0.25–40 μg mL−1; detection limits were approximately 0.25 ng mL−1. It was demonstrated that the method can be used for the simultaneous determination of these six antibiotics in serum and urine samples.  相似文献   

19.
毛细管区带电泳法测定粉针剂中头孢拉定的含量   总被引:3,自引:0,他引:3  
用毛细管区带电泳法测定头孢拉定的含量 ,未涂层毛细管柱 (75 μm×48.5cm ,有效长度 40cm) ,电压 2 8kV ,检测波长 2 3 0nm ,温度 2 0℃ ,进样 5×1 0 3Pa× 3s。运行缓冲液为 2 5mmol/L硼砂缓冲液。方法的线性范围 3 1 .2 2μg/mL~ 749.2 8μg/mL ,检测限为 1 .1 7μg/mL。  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏