首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Neutral diol methacrylate‐based monoliths were developed for normal phase chromatography (NPC) and NP‐CEC of polar compounds including N‐glycans. Four different diol methacrylate‐based monoliths were synthesized via the copolymerization of a functional monomer using either glyceryl monomethacrylate (GMM) or glycidyl methacrylate (GMA) and a crosslinker either ethylene dimethacrylate (EDMA) or trimethylolpropane trimethacrylate (TRIM). While the GMM‐based monoliths yield in one reaction step polar diol methacrylate monoliths that are ready for use in NPC or NP‐CEC, the GMA‐based monoliths required a postmodification with hot sulfuric acid to convert the epoxy functions into diols before use in NPC or NP‐CEC. All the four monoliths are neutral and void of fixed charges on their surfaces but yet exhibited relatively strong EOF in NP‐CEC. The EOF is attributed to the adsorption of ions from the mobile phase thus forming the electric double layer necessary for producing a bulk mobile phase flow. Under the same in situ copolymerization conditions of GMM or GMA with either EDMA or TRIM, the GMM–EDMA monolith was the best choice in terms of retention, separation efficiency, EOF velocity in CEC and linear flow velocity in Nano‐LC.  相似文献   

2.
We examined the use of monolithic capillary columns prepared via ring-opening metathesis polymerization (ROMP) for peptide separation in voltage-assisted capillary LC (voltage-assisted CLC). In order to demonstrate their potential for peptide separation, ROMP-derived monoliths with RP properties were prepared. The preparation procedure of monoliths was transferred from ROMP monoliths optimized for CLC. ROMP monoliths were synthesized within the confines of 200 microm id fused-silica capillaries with a length of 37 cm. After optimization of the chromatographic conditions, the separation performance was tested using a well-defined set of artificial peptides as well as two peptidic mixtures resulting from a tryptic digest of BSA as well as a collagenase digest of collagen. ROMP monoliths showed comparable performance to other monolithic separation media in voltage-assisted CLC published so far. Therefore, we conclude that by optimizing the composition of the ROMP monoliths as well as by using the controlled manner of their functionalization, ROMP monoliths bear a great potential in CLC and CEC.  相似文献   

3.
In micro total analysis systems, liquid chromatography (LC) works under pressure-driven flow is the essential analysis component. There were not, however, much works on microchip LC. Here we developed a microchip for reversed-phase LC using porous monolithic silica. The chip consisted of a double T-shaped injector and a approximately 40-cm serpentine separation channel. The octadecyl-modified monolithic silica was prepared in the specified part of the channel on the microchip using sol-gel process. Furthermore, the effect of geometry of turn sections on band dispersion at turns was examined under pressure-driven flow. High separation efficiencies of 15,000-18,000 plates/m for catechins were obtained using the LC chip.  相似文献   

4.
Capillary Electrochromatography (CEC) offers a rapid, economical, and efficient means for resolving nonionic compounds in the reversed phase mode on octadecylsilane (ODS) columns. A CEC optimization on a Hypersil ODS capillary column was employed to identify a suitable mobile phase for the pressure-driven (reversed phase ODS) separation of the anti-inflammatory 2-phenylmethyl-1-naphthol (DUP 654), and its related substances. The proportions of mobile phase modifiers methanol, acetonitrile, and water as well as pH were employed as variables in a stacked mixture design. Comparable response surface profiles were obtained for the CEC separations at pH 4 and pH 8. However, subtle differences were evident in the quality of separations obtained in the liquid chromatographic (LC) mode when using a specially-prepared column packed with exactly the same stationary phase as used in the CEC experiments. A mapping of the response surface for separations on a commercially available Hypersil ODS LC column revealed obvious differences. The differences indicate that the transfer of ODS based separation methods between CEC and LC involves more than simply transferring the conditions from one mode to the other.  相似文献   

5.
A novel approach is introduced and evaluated for the preparation of silica-based monoliths by a sol–gel technique where in situ polymerization was carried out by γ-ray irradiation within the capillary. The γ-radiation-initiated synthesis generated radicals directly on the monomer, thereby avoiding use of any initiator. The chromatographic behavior of the capillary monolithic columns was studied in the modes of CEC, p-CEC and low pressure-driven separation, all of which exhibited reversed-phase character. Various operational parameters, such as column temperature, separation voltage, acetonitrile content and buffer pH, were varied to assess their influence on column performance in the separation of a series of neutral compounds including thiourea, benzene, toluene, ethyl benzene, biphenyl and naphthalene. A scanning electron micrograph of a cross-section of the capillary column showed that the gel took the form of a spherical particle aggregate and adhered to the column inner wall. It provided a viable alternative to either thermally initiated or photo polymerization for the preparation of monolithic columns.  相似文献   

6.
Methacrylate-ester-based monoliths containing quaternary ammonium groups were prepared in situ in capillary columns and in simultaneous experiments in vials, employing thermal initiation. The chromatographic properties of the monoliths were determined with capillary electrochromatography (CEC), and their morphology was studied with mercury-intrusion porosimetry on the bulk materials. Materials with different, well repeatable pore-size distributions could be prepared. A satisfactory column-to-column and run-to-run repeatability was obtained for the electro-osmotic mobility, the retention characteristics (k-values) and the efficiency on the columns prepared and tested in the CEC mode. A relatively high electro-osmotic flow was observed in the direction of the positive electrode. The electro-osmotic mobility was found to be influenced only marginally by mobile-phase parameters such as the pH, ionic strength, and acetonitrile content. The retention behavior of the monolithic columns was similar to that of columns packed with C18-modified silica particles. Columns could be prepared with optimum plate heights ranging from 6 microm for unretained compounds to 20 microm for well retained (k=2.5) polyaromatic hydrocarbons. However, for specific analytes a - still unexplained - lower chromatographic column efficiency was observed.  相似文献   

7.
Microwave irradiation was firstly attempted for the preparation of organic-based monoliths of poly(styrene-divinylbenzene- methacrylic acid), which single step in situ polymerization was carried out during 15 min. The colunm permeability, electrophoretic and chromatographac behaviors were comparatively evaluated using pressure-assisted CEC, GEC and low pressure-driven separation modes. The largest theoretical plates for the preparing column could be close to 18,0000 plates/m for thiourea in the mode of p-CEC. It provided a viable alternative to traditional initiation means for the perparation of monolithic capillary columns.  相似文献   

8.
Capillary electrochromatography (CEC) has been performed with a series of C14, methlyacrylamide based monolithic columns. These monoliths with different porosities were prepared by in-situ copolymerization in fused-silica capillaries. The porous properties of monoliths were further observed using scanning electron micrographs (SEM) and measured using a mercury porosimeter. The effect of various alcohols as porogens on porous structural properties and chromatographic behaviors were also investigated. The effects of organic additive, pH value and ionic strength in mobile phase on electroosmosis flow (EOF) and separation were further discussed. Meanwhile, the baseline separation of 6 neutral compounds can be well obtained. In addition, the monolithic column demonstrates the high column efficiency and satisfactory reproducibility.Acknowledgements We gratefully acknowledge the support of the National Natural Science Foundation of China.  相似文献   

9.
A method is described for the synthesis of rigid, macroporous polymers (monoliths) to be used as stationary phases in capillary electrochromatography (CEC). The procedure reproducibly results in columns with good mechanical and chemical stability. Once the procedure was optimized, it yielded the desired CEC columns in nearly 100% of the cases. The batch-to-batch standard deviation of the migration of the electroosmotic flow (EOF) marker for nine randomly chosen columns was 5%. The polymerization is carried out inside the capillary, an aqueous phase is used as solvent. Monomers based on acrylamides with varying hydrophilicity were used to introduce the interactive moieties together with piperazine diacrylamide as cross-linker and vinylsulfonic acid as provider of the charged, EOF-producing moieties. The pore size of the monoliths was adjusted by adding varying amounts of ammonium sulfate to the reaction mixture. In this manner, the average pore size of a given monolith could be reproducibly adjusted to values ranging from 50 nm to 1.3 microm. The procedure was optimized for four particular types of monoliths, which differed in hydrophobicity. The latter was adjusted by introducing suitable co-monomers, such as alkyl chain-bearing molecules, into the monolithic structure. Attempts to systematically investigate the chromatographic behavior of the monolithic stationary phases were made, using a model mixture of aromatic compounds as sample. The standard deviations for the run-to-run reproducibility of the retention times for unretained and retained analytes were <1.5%. Flat Van Deemter curves were measured even at elevated flow-rates (2 mm/s). Plate heights between 10 and 15 microm were measured in this range. The retention order was taken as the principal indication for the chromatographic mode. The separation was found to be governed neither by pure reversed-phase nor by pure normal-phase chromatography, even on monoliths, where large amounts of C6 ligands had been introduced.  相似文献   

10.
Xie C  Hu J  Xiao H  Su X  Dong J  Tian R  He Z  Zou H 《Electrophoresis》2005,26(4-5):790-797
A silica-based monolithic capillary column was prepared via a sol-gel process. The continuous skeleton and large through-pore structure were characterized by scanning electron microscopy (SEM). The native silica monolith has been successfully employed in the electrochromatographic separation of beta-blockers and alkaloids extracted from traditional Chinese medicines (TCMs). Column efficiencies greater than 250 000 plates/m for capillary electrochromatography (CEC) separation of basic compounds were obtained. It was observed that retention of basic pharmaceuticals on the silica monolith was mainly contributed by a cation-exchange mechanism. Other retention mechanisms including reversed-phase and normal-phase mechanisms and electrophoresis of basic compounds also played a role in separation. A comparison of the differences between CEC and capillary zone electrophoresis (CZE) separation was also discussed.  相似文献   

11.
Reactive organic polymer monoliths were prepared in fused-silica capillaries by UV-initiated free radical polymerization of N-acryloxysuccinimide (NAS) as reactive monomer, ethylene dimethacrylate as crosslinker, azobisisobutyronitrile as initiator, and toluene as porogen. In a second synthetic step, chemical derivatization of the activated-ester moieties was performed in situ through alkylation reaction with alkylamines to afford monolithic stationary phases with potential reversed-phase properties. A correlation between the synthesis conditions--composition of the reactive solution--chemical characteristics of the reactive polymer monoliths--nitrogen/NAS content--and the reversed-phase separation properties of the functionalized monolithic columns--selectivity towards homologous series of akylbenzenes--was clearly established. This finding offers the possibility of adjusting the experimental conditions with respect to the target applications. The monolithic stationary phases with optimized chemical and porous structures were used for the CEC separation of alkylbenzenes, phenols, anilines, organic acids, amino acids, and proteins. The data indicate that depending on the nature of the analytes (charge, hydrophobic/hydrophilic balance, size) reversed-phase or mixed modes may account for the observed separation.  相似文献   

12.
Polymeric methacrylate-based monoliths are evaluated in capillary electrochromatography (CEC) and pressurized capillary electrochromatography (p-CEC) for their potential in pharmaceutical analysis. Using a given polymerization mixture as a basis for the monolith synthesis, different mobile phase pH at constant organic modifier concentrations are tested in both CEC and p-CEC. The test set consists of basic, acidic, amphoteric, and neutral compounds, which are mainly pharmaceuticals. Because of the mainly hydrophobic character of the stationary phase, the interactions are largest when the compounds appear in an uncharged state, but some ion-exchange phenomena with negatively charged compounds can also be observed. In CEC, acidic substances are most retained at low pH. For amphoteric and neutral compounds, no preference regarding analyzing pH can be derived from these experiments. For basics, a high pH is chosen, but a reduced solvent strength is needed to enhance the retention of these compounds. The retention mechanism in p-CEC can also be assigned to both hydrophobic and ionic interactions. For acidic, amphoteric, and neutral compounds, acceptable retention is seen. For the basic compounds, the retention with a mobile phase containing 50% organic modifier is low, as in CEC. However, when the organic modifier content in the mobile phase is decreased, retention increases and the selectivity of the stationary phase is more pronounced. This mode of operation presents a possibility for separating some test mixtures, thus some potential for pharmaceutical analysis is seen. More efforts are needed to obtain higher efficiencies and better peak shapes, which might be solved by a further optimization of both the stationary phase synthesis and the mobile phase composition.  相似文献   

13.
Enantioseparations in nonaqueous capillary electrochromatography (CEC) are reported in this study for the first time, using wide-pore aminopropyl silica gel coated with helically chiral poly(diphenyl-2-pyridylmethyl methacrylate) (PDPM) as chiral stationary phase (CSP). The anodic electroosmotic flow (EOF) in a methanolic solution of ammonium acetate was used for the migration of neutral analytes through the packed bed in the capillaries. Four different techniques, high-performance liquid chromatography (HPLC) in common-size columns, capillary HPLC, pressure-assisted CEC and CEC were compared from the viewpoint of separation parameters. The latter three were performed with the same experimental setup, varying the relative contribution of the pressure-driven and the electrically driven flow to the overall mobility of the analyte. Capillary HPLC offers clear advantages compared to enantioseparations in common-size columns. However, for a given particle size of the packing material, CEC was not obviously advantageous compared to pressure-driven separations.  相似文献   

14.
Monolithic silica columns with surface-bound octadecyl (C18) moieties have been prepared by a sol-gel process in 100 microm ID fused-silica capillaries for reversed-phase capillary electrochromatography of neutral and charged species. The reaction conditions for the preparation of the C18-silica monoliths were optimized for maximum surface coverage with octadecyl moieties in order to maximize retention and selectivity toward neutral and charged solutes with a sufficiently strong electroosmotic flow (> 2 mm/s) to yield rapid analysis time. Furthermore, the effect of the pore-tailoring process on the silica monoliths was performed over a wide range of treatment time with 0.010 M ammonium hydroxide solution in order to determine the optimum time and conditions that yield mesopores of narrow pore size distribution that result in high separation efficiency. Under optimum column fabrication conditions and optimum mobile phase composition and flow velocity, the average separation efficiency reached 160 000 plates/m, a value comparable to that obtained on columns packed with 3 microm C18-silica particles with the advantages of high permeability and virtually no bubble formation. The optimized monolithic C18-silica columns were evaluated for their retention properties toward neutral and charged analytes over a wide range of mobile phase compositions. A series of dimensionless retention parameters were evaluated and correlated to solute polarity and electromigration property. A dimensionless mobility modulus was introduced to describe charged solute migration and interaction behavior with the monolithic C18-silica in a counterflow regime during capillary electrochromatography (CEC )separations. The mobility moduli correlated well with the solute hydrophobic character and its charge-to-mass ratio.  相似文献   

15.
A new reactive capillary monolith as an alternative to the commonly employed glycidyl methacrylate-based stationary phases in capillary electrochromatography (CEC) applications was synthesized and post-functionalized with charge-bearing groups. For this purpose, a hydrophilic capillary monolith with reactive 3-chloro-2-hydroxypropyl moiety was first obtained by the copolymerization of a new methacrylate-based monomer, 3-chloro-2-hydroxypropyl methacrylate (HPMA-Cl), with a methacrylic crosslinking agent, ethylene glycol dimethacrylate (EDMA). The presence of 3-chloro-2-hydroxypropyl functionality in poly(HPMA-Cl-co-EDMA) monolith allowed the synthesis of monoliths carrying strongly ionizable anionic, cationic or neutral groups such as sulfonic acid, quaternary ammonium or octadecyl, respectively, via simple and single-stage reactions. In the present study, a reactive poly(HPMA-Cl-co-EDMA) capillary monolith was functionalized with sodium bisulfite (NaHSO3) to have a strongly ionizable sulfonic acid group on the monolith. The resulting monolith providing cathodic electroosmotic flow in CEC was successfully used for the separation of phenol derivatives. The theoretical plate numbers up to 63,000 plates/column were achieved. The results showed that a new promising, reactive support that could be functionalized with different chromatographic ligands for different chromatographic applications was obtained in the study.  相似文献   

16.
Summary: Acrylate/methacrylate-based monoliths have been prepared via electron- beam (EB) initiated polymerization. These monolithic columns were found suitable for application in the analytical scale separation of various analytes such as proteins. Functionalization of the monolithic columns was accomplished via copolymerization of functional monomers. Selected examples of both synthesis and application will be summarized.  相似文献   

17.
Organic monolithic stationary phases were synthesized in fused-silica capillaries. They were prepared by in situ polymerization under UV irradiation of various alkyl acrylates, 1,3-butanediol diacrylate, and 2-acrylamido-2-methyl-1-propanesulfonic acid in a ternary porogenic solvent. The resulting stationary phases were tested in CEC. The influence of UV irradiation energy on the resulting separative performances of the monoliths was studied. It was thus demonstrated that the use of hexyl acrylate rather than butyl acrylate and lauryl methacrylate gives highly efficient monoliths (more than 300 000 plates per meter) with optimized EOF. It was also confirmed that the mobile phase ionic strength may affect significantly the separation efficiency. The influence of the nature of the mobile phase organic modifier (ACN or methanol) on EOF, retention, efficiency, and selectivity was studied and differences were observed. Finally, the performances of monolithic stationary phases developed and optimized for CEC separations were evaluated in nanoLC.  相似文献   

18.
Organic monolithic stationary phases have been synthesized in UV-transparent fused-silica capillaries, which have been used as test format of microfabricated device channels. The columns have been prepared by in situ polymerization of butyl acrylate, lauryl acrylate, 1,3-butanediol diacrylate, and 2-acrylamido-2-methyl-1-propanesulfonic acid (AMPS) in a ternary porogenic solvent. The resulting stationary phases have been tested in capillary electrochromatography and exhibited reversed-phase chromatography behavior toward neutral solutes. Van Deemter plots of phenylureas and polycyclic aromatic hydrocarbons, selected as model analytes, have been determined to study the influence of various polymerization and separation parameters on properties of the monoliths. The amount of AMPS and the nature of monomers in the polymerization solution have been thus adjusted. It has been observed that the ionic strength of the mobile phase may affect significantly the efficiency of the separation. The effect of the percentage of acetonitrile in the mobile phase on efficiency and permeability of the organic monoliths has also been investigated. Efficiencies greater than 300,000 plates/m have been obtained with the test compounds. Stability and reproducibility have been extensively studied.  相似文献   

19.
微波聚合快速制备分子印迹毛细管电色谱整体柱   总被引:10,自引:0,他引:10  
以甲基丙烯酸为功能单体、己二醇二甲基丙烯酸酯为交联剂、 对羟基苯甲酸为模板分子, 采用微波辐射聚合的方式快速制备了分子印迹毛细管电色谱整体柱, 并取得了较好的印迹效果. 分子印迹材料的原位制备5 min即可完成, 大大快于国内外传统的方法.  相似文献   

20.
在2.2mm内径的石英管中,采用正硅酸四乙酯水解的溶胶-凝胶法合成了填充细石英砂的高比表面积电色谱整体柱,并用正辛基三乙氧基硅烷键合制备反相色谱固定相.填充细石英砂的电色谱整体柱抑制了大柱径引起的电流热效应,采用电渗流驱动流动相,分离了苯酚和苯,实验证明该整体微柱用于电色谱分离和改善浓度检出限的可行性.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号