首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
An assay for the selective quantification of pseudoephedrine in human plasma and urine was developed using high-performance liquid chromatography with UV detection at 205 nm. Analyte and internal standard were extracted from alkaline plasma or urine into a mixture of n-hexane and diethyl ether, and the organic phase was back-extracted into dilute acid. The chromatographic system comprises microparticulate cyanopropyl-silica as stationary phase and a ternary solvent mixture with ion-pair reagents as mobile phase. Using 0.25 ml plasma, the lower limit of quantification was 25 ng/ml with excellent linearity up to 1000 ng/ml. In urine, the calibration ranged from 2.5 to 100 micrograms/ml. The selectivity of the method was demonstrated for several pharmaceuticals with similar structures. The validated method was applied to a pharmacokinetic study with a single oral dose of 100 mg of pseudoephedrine in two galenic formulations. Precision and accuracy data of the assay and calculated pharmacokinetic parameters are presented.  相似文献   

2.
Abstract

A simple and sensitive high-performance liquid chromatographic method for quantitation of clopamide in human plasma has been developed. the assay uses a reversed-phase C18 microbore column (2 mm I.D. × 100 mm) packed with 5 μm ODS Hypersil. the chromatographic separation was achieved by using an isocratic mobile phase comprising acetonitrile-10 mM phosphate buffer pH 4 (17:83, v/v) at a flow rate of 0.5 ml/min. the eluant was monitored by a UV detector operating at 241 nm. the assay was based on an organic extraction before chromatographic separation. to 1 ml plasma sample, 100 μl of the internal standard, methylparaben (300 ng/ml), and 8 ml of diethyl ether were added. the samples were shaken and centrifuged, the organic layer was then transferred to a tapered centrifuge tube and evaporated to dryness. the residue was reconstituted and injected onto the HPLC column. the inter-and intra-assay coefficients of variation were found to be less than 10%. the lowest limit of detection for clopamide in plasma was 5 ng/ml. the method is sensitive, specific and allows for routine analysis in the pharmacokinetic studies.  相似文献   

3.
A simple, rapid and sensitive method for the extraction and high-performance liquid chromatographic analysis of adriamycin in tissue and plasma is described. Tissue (5-100 mg) and plasma (1 ml) samples underwent a C18 Sep-Pak extraction into methanol. Chromatography was performed on a muBondapakphenyl column using a mobile phase of acetonitrile-0.1 M ammonium formate (pH 4.0) with a flow-rate of 2 ml/min. Fluorometric detection was used with an excitation of 480 nm and an emission of 550 nm. The procedure produced a linear curve for the concentration range 25-1000 ng/ml. The development of the assay produced rapid, repeatable and accurate results for both small tissue samples and plasma.  相似文献   

4.
A sensitive and reproducible high-performance liquid chromatographic method was developed to assay ampherotericin B in plasma, blood, urine and various tissue samples. Amphotericin B was isolated from each sample matrix by solid-phase extraction (Bond-Elut). The eluate from Bond-Elut containing amphotericin B was injected onto a reversed-phase C18 column (Waters, mu Bondpak, 10 microns, 300 mm x 3.9 mm I.D.) with a mobile phase of 45% acetonitrile in 2.5 mM Na2EDTA at 1 ml/min. Detection of amphotericin B was by ultraviolet absorption at 382 nm. Blood and tissues were homogenized and extracted with methanol prior to Bond-Elut extraction. The extraction efficiencies of amphotericin B from plasma, blood and tissues were approximately 90, 70 and 75%, respectively. The sensitivity of the assay was less than or equal to 5 ng/ml for plasma, less than or equal to 25 ng/ml for blood, 2.5 ng/ml for urine and 50 ng/g for tissues. The linearity of the assay method was up to 2.5 micrograms/ml for plasma, 5 micrograms/ml for blood, 500 ng/ml for urine and 500 micrograms/g for tissues. The assay was reproducible with an intra-day coefficient of variation (C.V., n = 3) of less than 5% in general for plasma, blood and tissues. The inter-day C.V. of the assay was less than 5% for plasma (n = 5), less than 10% for blood (n = 4) and less than 5% for tissues (n = 3). The overall variability in the urine assay was generally less than 10%. This method has demonstrated significant improvement in the sensitivity and reproducibility in assaying amphotericin B in plasma and especially in blood, urine and tissues. We have employed this assay to compare the pharmacokinetic and tissue distribution profiles of amphotericin B in rats and dogs following administration of Fungizone and ABCD (amphotericin B-cholesteryl sulfate colloidal dispersion), a lipid-based dosage form. In addition, the assay method for plasma and urine samples can also be applied to pharmacokinetics studies of amphotericin B in man.  相似文献   

5.
A sensitive high-performance liquid chromatographic method for the determination of the enantiomers of atenolol in rat plasma has been developed. Racemic atenolol and practolol (internal standard) were extracted from alkalinized plasma (pH 12) into dichloromethane containing 3% (v/v) heptafluoro-1-butanol, and the organic layer was evaporated. The samples were derivatized with (+)-1-(9-fluorenyl)ethyl chloroformate at pH 8.5 for 30 min. After removal of excess reagent, the diastereomers were extracted into dichloromethane. The diastereomers were separated on a Microspher C18 column (3 microns) with a mobile phase of acetonitrile-sodium acetate buffer (0.01 M, pH 7) (50:50, v/v) at a flow-rate of 0.8 ml/min. Fluorescence detection (lambda ex = 227 nm, lambda em = 310 nm) was used. When 100 microliters of plasma were used, the quantitation limit was 10 ng/ml for the atenolol enantiomers. The assay was applied to measure concentrations of atenolol enantiomers in plasma after intravenous administration of racemic atenolol to rats.  相似文献   

6.
A sensitive high-performance liquid chromatographic (HPLC) assay using fluorescence detection for quantifying lidocaine levels in plasma (in the ng/ml range) was developed. This novel HPLC assay has made possible the simultaneous monitoring of lidocaine levels in coronary and peripheral plasma obtained after myocardial controlled-release matrix administration (0.92 mg/kg during 4 h) in the arrhythmic dog. The method employed extracts the drug from plasma using 1-chlorobutane and a subsequent derivatization with 9-fluorenylmethylchloroformate in acetonitrile at 110 degrees C. The derivative was chromatographed on a C18 reversed-phase column and measured with fluorescence detection (excitation 254 nm, emission 313 nm). N-Methylephedrine was found to be suitable as an internal standard, post-derivatization. The derivatization product of lidocaine was identified and characterized by mass spectral analysis. It was found to have a unique and reproducible dicarbamate structure, which was stable for at least three days at room temperature. The method was tested with human plasma as well as on dog plasma. Analytical recoveries were 88.6 +/- 3.6 and 77.4 +/- 3.0% (mean +/- S.E.), respectively, at levels ranging from 25 to 200 ng/ml. The lower detection limit was 1 ng/ml lidocaine. In conclusion, this rapid and convenient analysis was found to be suitable for the bioavailability pharmacokinetic assessment of lidocaine following low-dose regional drug administration.  相似文献   

7.
Zaia DA  Ribas KC  Zaia CT 《Talanta》1999,50(5):1003-1010
A simple, sensitive, and selective method has been developed for determination of cysteine (Cys) or carbocysteine (carboCys) in pharmaceutical products, shampoos and a mixture of amino acids. The results showed the reaction between p-benzoquinone (PBQ) and Cys occurs through the sulfhydryl group. Previous derivatization or extraction is not necessary before the assay is carried out. The method is based on the fact that the product of reaction between PBQ and Cys absorbs at 352 and 500 nm or PBQ and carboCys absorbs at 500 nm. Beer's law is followed in the range 0-40 mug/ml for Cys and 0-150 mug/ml for carboCys. The product of reaction PBQ-Cys is stable for 2 h with absorption bands at 352 and 500 nm. In the presence of amino acids, PBQ is highly selective to Cys. Several substances such as amino acids, urea, salts, and dipeptide did not interfere with the proposed method. A recovery of about 100% is observed for both Cys and carboCys, when the method is applied to determine Cys in a mixture of amino acids resembling blood plasma, shampoo, and pill food as well as carboCys in pharmaceutical products.  相似文献   

8.
Phyllanthoside is a glycoside isolated from the roots of the Central American tree Phyllanthus acuminatus Vahl with antitumor activity against murine B-16 melanoma and P-388 leukemia. We report a reversed-phase high-performance liquid chromatographic assay for phyllanthoside in plasma using a 25-cm RP-18, 5-micron column with a linear 10-min gradient of 50% to 100% methanol in 0.3 M sodium acetate, pH 4.0, at a flow-rate of 1.5 ml/min. Eluting peaks were detected at 270 nm. The lower limit of sensitivity of the assay for phyllanthoside in 0.5 ml plasma following ethyl acetate extraction at pH 7.0 was 0.25 micrograms/ml and the coefficient of variation at 1 microgram/ml was +/- 7.4%. Phyllanthoside was very rapidly broken down by mouse and rat plasma in vitro to an unidentified less polar metabolite. Formation of this metabolite was completely inhibited by preheating mouse plasma to 100 degrees C for 10 min. When mouse plasma was diluted 1:50 with water the half-life of phyllanthoside disappearance at 37 degrees C was 2.0 min. Breakdown of phyllanthoside in plasma from other species was slower than in mouse and the initial half-life at 37 degrees C in dog plasma was 30 min, in monkey plasma 33 min and in human plasma 38 min. The same less polar metabolite as in mouse plasma was formed slowly by plasma of monkey and dog. Phyllanthoside did not accumulate in human red blood cells. Binding of phyllanthoside to human plasma protein determined by ultrafiltration at 4 degrees C was 70%.  相似文献   

9.
A reversed-phase ion-pair high-performance liquid chromatographic assay is described for the rapid and sensitive quantitation of the H2-receptor antagonist ranitidine in human plasma and urine. The method involves a single-step extraction of the alkalinized sample with methylene chloride and analysis of the evaporated extract on a cyano column. Detection was performed by ultraviolet absorbance monitored at 318 nm. The overall run time of the assay was 5 min at a flow-rate of 2.0 ml/min. The limit of sensitivity was 1 ng/ml ranitidine in human plasma. Urine and plasma samples collected from a subject after administration of an oral dose of 150 mg of ranitidine were analyzed by this method. Furthermore, the procedure was applied to determine the red blood cell partition coefficient of ranitidine in a concentration range up to 10 micrograms/ml.  相似文献   

10.
A high-performance liquid chromatographic (HPLC) method for determining 2-(alpha-thenoylthio)propionylglycine (TTPG) and its two main metabolites, thiophenecarboxylic acid and thiopronine, in biological samples was developed. TTPG and its metabolites were extracted by solvent partition and then determined by reversed-phase HPLC with UV detection at 245, 295 and 360 nm. This procedure was validated in order to allow the assay of these compounds in plasma and urine samples with sufficiently low detection limits (50 ng/ml for TTPG and TCA and 100 ng/ml for thiopronine) and with good linearity within the concentration range investigated. It was applied to a comprehensive pharmacokinetic investigation of TTPG in healthy volunteers.  相似文献   

11.
D-Lactate in biological samples was converted into a strongly fluorescent substance in a one-vial reaction. It was first converted into the pyruvate hydrazone in the presence of D-lactate dehydrogenase, an NADH-reoxidation system using diaphorase, D,L-6,8-thioctamide and hydrazine. This hydrazone was then converted into 2-hydroxy-6,7-dimethoxy-3-methylquinoxaline by 1,2-diamino-4,5-dimethoxybenzene in 1 M hydrochloric acid, and the quinoxaline was extracted and measured fluorimetrically at 432 nm (excitation at 365 nm). The calibration curve for D-lactate was linear up to at least 100 nmol/ml of the assay mixture, with a determination limit of 2 nmol/ml. The quinoxaline was also analysed by high-performance liquid chromatography with fluorimetric detection. The calibration curve for D-lactate was linear from 500 fmol to 75 nmol in the reaction mixture. This method was 4000 times more sensitive than the fluorimetric method, and could determine D-lactate in blood plasma volumes of less than 1 microliter.  相似文献   

12.
A sensitive high-performance liquid chromatographic method was developed for the stereoselective assay of (R)- and (S)-propranolol in human plasma. The method involves diethyl ether extraction of the drugs and a racemic internal standard, N-tert.-butylpropranolol, followed by derivatization of the compounds with the chiral reagent (R,R)-O,O-diacetyl tartaric acid anhydride. The resulting diastereomeric derivatives were separated isocratically on a reversed-phase column. Quantitation was achieved by the peak-height ratio method with reference to the internal standard. The assay was accurate and reproducible in the concentration range 1-100 ng of (R)- and (S)-propranolol per ml plasma, using fluorescence detection at lambda ex 290 nm and lambda em 335 nm. The applicability of this method was demonstrated for the determination of concentration-time profiles of propranolol enantiomers in the course of comparative pharmacokinetic studies.  相似文献   

13.
A rapid, sensitive and selective high-performance liquid chromatographic method for the determination of the neuroprotectant 6-nitro-7-sulphamoylbenzo[f]quinoxaline-2,3-dione in rat plasma has been established and validated. Samples of 0.5 ml of plasma are extracted by elution from a Bond-Elut column with methanol and analysed on a reversed-phase column. The wavelength of UV detection is 254 nm. The method is linear at least up to 30 micrograms/ml, with a lowest reliable determination level of 4 mg/ml. The assays has a coefficient of variation of 13% at 10 ng/ml and 4% at 1000 ng/ml. Small variations in the extraction procedure and the liquid chromatographic conditions have minimal or no influence on the assay.  相似文献   

14.
An assay is presented for the extraction and quantitation of two oximes, 2-hydroxyimino-methyl-3-methyl-1-[2-(3-methyl-3-nitrobutyloxyme thyl)] imidazolium chloride (oxime A) and 1-[1-(3-butynyloxymethyl)]-2-hydroxyiminomethyl-3-methylimidazo lium chloride (oxime B), in human plasma and is demonstrated to be linear over two overlapping concentration ranges: 10-500 and 100-1000 ng/ml. The assay utilizes a liquid-liquid, ion-pair extraction and a normal-phase chromatographic separation on a silica column with ultraviolet detection at 270 nm. The method is sensitive, rapid and accurate. The limit of detection is 10 ng/ml (signal-to-noise ratio S/N greater than 10). The mean extraction recoveries of the oximes were greater than 86% at all concentration levels. The intra-assay variability was less than 3.3%, the inter-assay variability less than 7.2%. The compound is stable in plasma for 23 weeks when stored at -15 degrees C or -80 degrees C.  相似文献   

15.
A high-performance liquid chromatographic assay for the determination of isoniazid, acetylisoniazid, acetylhydrazine and diacetylhydrazine (plasma and urine) was developed. The m-chlorobenzoyl derivatives of isoniazid, acetylhydrazine and the internal standard propionylhydrazine were prepared, separated on a RP-18 column and detected at 220 nm. Acetylisoniazid, diacetylhydrazine and the internal standard dipropionylhydrazine were converted to isoniazid, acetylhydrazine, and propionylhydrazine by acidic hydrolysis and subsequently derivatized with m-fluorobenzoyl chloride, separated on a RP-18 column and detected at 220 nm. The lower limits of detection in plasma are acetylhydrazine 0.5 nmol/ml, isoniazid 1.0 nmol/ml, diacetylhydrazine 1.0 nmol/ml and acetylisoniazid 2.0 nmol/ml, and in urine, acetylhydrazine 10 nmol/ml, isoniazid 15 nmol/ml, diacetylhydrazine 20 nmol/ml and acetylisoniazid 40 nmol/ml. This method is sensitive, reproducible, accurate and precise; therefore, it is well suited for detailed pharmacokinetic studies.  相似文献   

16.
A HPLC-UV method has been developed for assaying rifampicin in plasma and liver. The assay involved a liquid-liquid extraction procedure with dichloromethane-pentane (1:1). An Ultrabase-C18 column and a simple mobile phase consisting of a water (pH 2.27)-acetonitrile (40:60, v/v) mixture were used. The flow-rate was 1 ml/min and the effluent was monitored at 333 nm. Results from the HPLC analyses showed that the assay method is linear in the ranges 0.1-1 and 1-50 microg/ml for plasma, and 0.6-40 microg/g for liver. Intra- and inter-day R.S.D. were below 15% for all the sample types. Recoveries averaged 83 and 95% for plasma and liver, respectively. The method is being successfully applied to determine rifampicin in plasma and liver samples taken during pharmacokinetic studies in rats.  相似文献   

17.
A liquid chromatographic method using a solid-phase extraction procedure for the quantification of sotalol in plasma and urine is described. Sotalol is eluted from an extraction column with ethyl acetate-acetonitrile (1:2) and, after separation by reversed-phase high-performance liquid chromatography on a mu Bondapak C18 column, is quantified by fluorescence detection at excitation and emission wavelengths of 240 and 310 nm, respectively. The method has been demonstrated to be linear over the concentration ranges 10-6000 ng/ml in plasma and 0.5-100 micrograms/ml in urine. Mean inter-assay accuracy of the method for plasma ranged from 93 to 100% and for urine from 102 to 114%; precision ranged from 0.5 to 1.6% for plasma over a concentration range of 200-4000 ng/ml and for urine from 0.7 to 2.0% at concentrations of 2-50 micrograms/ml. Mass spectrometry confirmed the presence of sotalol in isolated chromatographic fractions of plasma and urine extracts from subjects given sotalol orally.  相似文献   

18.
Abstract

A simple and sensitive HPLC method was developed for the determination of naproxen in human plasma. The assay employs a microbore column packed with a C18 reversed-phase material (5 μm ODS Hypersil) with an isocratic mixture of acetonitrile and 10 mM phosphate buffer, pH 2.5 (40:60, v/v) as the mobile phase. The mobile phase was pumped at a flow rate of 0.5 ml/min. For sample analysis 200 μl of acetonitrile containing internal standard (flurbiprofen) was added to 100 μl of plasma. After centrifugation 10 mM phosphate buffer, pH 7.4 (200 μl) was added to the tube, then vortexed and centrifuged. The supernatant (20 μl) was injected onto the HPLC column. The chromatographic separation was monitored by a fluorescence detector at an emission wavelength of 350 nm with an excitation wavelength of 225 nm. The direct precipitation of plasma protein using acetonitrile gave a good recovery for both naproxen and the internal standard. The detection limit was 0.1 μg/ml for naproxen. The intra- and inter-assay coefficients of variation at different concentrations evaluated were less than 10%.  相似文献   

19.
A sensitive, enantioselective, high-performance liquid chromatographic (HPLC) method was developed and validated to determine S-(-)- and R-(+)-bisoprolol in human plasma. Baseline resolution was achieved using the teicoplanin macrocyclic antibiotic chiral stationary phase (CSP) known as Chirobiotic T with a polar ionic mobile phase (PIM) consisting of methanol-glacial acetic acid-triethylamine (100 : 0.02 : 0.025, v/v/v) at a flow rate of 1.5 ml/min and fluorescence detection set at 275 nm for excitation and 305 nm for emission. All analyses with S-(-)-atenolol as the internal standard were conducted at ambient temperature. The assay involved the use of a solid-phase extraction procedure for human plasma samples prior to HPLC analysis. The C18 cartridge gave good recovery rates for both enantiomers without any interference. The method was validated over the range of 20-200 ng/ml for each enantiomer concentration. Recovery rates for S-(-)- and R-(+)-bisoprolol enantiomers were in the range of 95-102%. The method proved to be precise (within-run precision expressed as % RSD ranged from 1.0-6.2% and between-run precision ranged from 0.9-6.7%) and accurate (within-run accuracies expressed as percentage error ranged from 0.2-4.8% and between-run accuracies ranged from 0.3-1.7%). The limit of quantitation and limit of detection for each enantiomer in human plasma were 20 and 5 ng/ml, respectively.  相似文献   

20.
《Analytical letters》2012,45(14):2267-2274
A simple and sensitive liquid chromatography assay following solid phase extraction was developed for simultaneous determination of adenosine and inosine in sheep plasma. The system consisted of a Symmetry C18 column, a mobile phase composed of acetonitrile, 100 mM sodium dihydrogen phosphate and water, and ultraviolet detection at 254 nm. The method showed good sensitivity (limits of detection for adenosine and inosine were 30 and 50 ng/ml, respectively, in the plasma samples), repeatability, and linearity. The developed method was applied to sheep plasma samples from a study examining the cardio active potential of the combination of adenosine and inosine.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号