首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Detection of carbohydrates in capillary electrophoresis   总被引:3,自引:0,他引:3  
This review focuses on recent developments in sensitive detection modes for carbohydrates after separation by capillary electrophoretic methods. To bring detection sensitivity for carbohydrates analysis in line with current methods in protein sequencing, concentration detection limits of 10−6 molar or better are requires. A discussion of mass detection limits and concentration detection limits is followed by an overview of detection modes for natural and labeled carbohydrates. Amperometric detection and UV and laser-induced fluorescence detection after reductive amination, in particular with 8-aminonaphthalene-1,3,6-trisulfonic acid (ANTS), are discussed in more detail. Finally, the paper outlines developments to be expected in the near future, focusing on the needs in glycobiology such as improved sensitivity and selectivity.  相似文献   

2.
The feasibility of on-capillary derivatization of saccharides by aromatic amine-based fluorescent labeling agents was tested. To avoid the problematic evolution of gaseous hydrogen cyanide, the Schiff base reduction by sodium cyanoborohydride, as the second step of the standard reductive amination protocol, was omitted. Glucose was used as a model analyte and 7-amino-1,3-naphthalenedisulfonic acid as the labeling agent. Our experiments showed that the direct reaction of the saccharide with the labeling agent in 2.5-M acetic acid yields a labeled product that is sufficiently stable to be separated from the labeling agent in 20-mM phosphate buffer, pH 3.5, and detected using UV detection. The glucose and label zones were introduced separately into the capillary and mixed using a negative voltage. Mixing voltage, its duration, the concentration of acetic acid in the reaction zone, and the waiting time between mixing and separation were optimized. To show the applicability of the procedure to a broader range of analytes, a mixture of different types of saccharides, that is, xylose (pentose), fucose (hexose), glucose (hexose), N-acetylglucosamine (N-acetylaminosaccharide), and lactose (disaccharide), was subjected to derivatization and analysis under the optimal conditions. The linearity and repeatability of the process were evaluated as critical parameters for its analytical applications. Six-point calibration dependences in the 1–50 mM range showed excellent determination coefficients of 0.9992 or higher for all five saccharides tested. The repeatability of the labeled saccharide peak areas was between 2.2% and 4.3%.  相似文献   

3.
Jin LJ  Li SF 《Electrophoresis》1999,20(17):3450-3454
Carbohydrate analysis of urine is clinically important in assisting diagnosis of disorders of carbohydrate metabolism and understanding its pathologic significance. Paper chromatography and thin-layer chromatography are the techniques that are often employed for the determination of urinary carbohydrates. An aim of our experiments was to investigate the utility of capillary electrophoresis to develop a fast screening procedure of urinary carbohydrates. Simultaneous resolution of eight carbohydrates involving maltose, lactose, D-mannose, D-glucose, D-ribose, D-xylose, L-arabinose and D-galactose as markers was obtained with 130 mM borate (pH 10.2). Ethanol/water (80/20 v/v) and acetonitrile proved to be efficient reagents for urine sample clean-up which produced symmetrical peaks. The urine sample from a normal subject was determined to contain lactose, glucose, xylose and arabinose that fall within normal ranges of these carbohydrates in urine. The investigations made in this study may be potentially useful in carbohydrate screening, especially in neonatal urine screening.  相似文献   

4.
Separation of neutral carbohydrates by capillary electrophoresis   总被引:1,自引:0,他引:1  
The basic strategies for analysis of neutral carbohydrates by capillary electrophoresis are summarized. Neutral carbohydrates are dissociated in strong alkali to give anions, hence they can be separated directly by zone electrophoresis based on the difference between their dissociation constants. However, neutral carbohydrates are not electrically charged under normal conditions. Therefore, they should be converted to ions prior to or during analysis. Precapillary introduction of a basic or an acidic group to a neutral carbohydrate gives the derivative positive (in acidic media) or negative (in alkaline media) charge, respectively. The derivatives thus obtained can be separated by zone electrophoresis. Analysis of carbohydrates in a carrier containing an oxyacid salt (such as sodium borate) or an alkaline metal salt (such as calcium acetate) causes in situ conversion to anionic or cationic complexes, respectively, which are separated by zone electrophoresis. The effective uses of electrokinetic chromatography in sodium dodecyl sulfate micelles for hydrophobic derivatives (such as 1-phenyl-3-methyl-5-pyrazolone derivatives) and size-exclusion electrophoresis in gel-packed capillaris for size different oligosaccharides are also discussed. Each separation mode has its inherent method(s) for detection, which are also described here.  相似文献   

5.
Lee HL  Chen SC 《Talanta》2004,64(1):210-216
Microchip capillary electrophoresis (μCE) with amperometric detection at Cu electrode benefited fast separation and direct detection of carbohydrates. The working electrode of 50-μm Cu wire attached nearly against the channel outlet—4 μm, where it benefited collecting detection current and suppressing overwhelming noise. The use of alkaline medium was essential to separating and detecting carbohydrates, which dissociated into the sensitive alcolate anions. The 10-cm serpentine chip, though lengthening the migration time, it provided better efficiency. Sucrose, cellobiose, glucose, and fructose migrated from the outlet in 400 s +2000 V. The linear calibration plots ranging from 10 to 1000 μM with regression coefficients better than 0.996 were obtained. The injection-to-injection reproducibility of 1.24% (n=7) for glucose in peak current and 0.6% for migration times were excellent. The detection limit was low, down to 2.3 μM for glucose (S/N=3) or 27.6 attomole in mass detection.  相似文献   

6.
7.
Indirect UV detection of carbohydrates in capillary zone electrophoresis   总被引:1,自引:0,他引:1  
Summary A new system for the rapid and sensitive analysis of underivatized carbohydrates has been established using capillary zone electrophoresis with indirect UV detection. At an applied potential of 28 kV, sugars and sugar acids could be separated by the combined effects of electroendosmosis and electrophoresis within 20 minutes in a fused silica capillary of 50 m internal diameter and an effective length of 100 cm using 6mM sorbic acid, pH 12.1, as both carrier electrolytie and chromophore. The alkaline pH ensured ionization of the sugars and, hence, their detection by means of charge displacement. Furthermore, the chosen concentration of sorbic acid allowed the smallest fractional change in the background signal to be measured. While the electrophoretic mobilities of the sugars were found to increase within a pH range of 11.9 to 12.3, those of the sugar acids were not affected. Due to the increasing competition of hydroxide ions in the displacement of the chromophore with rising pH, a significant loss of sensitivity is observed at pH values higher than 12.1 and this pH was found to provide sufficient resolution, optimum sensitivity, and a acceptably short analysis time. Under these conditions, a lower detection limit of 2 pmol was obtained for glucose.  相似文献   

8.
Separation of negatively charged carbohydrates by capillary electrophoresis   总被引:3,自引:0,他引:3  
Capillary electrophoresis (CE) has recently emerged as a highly promising technique consuming an extremely small amount of sample and capable of the rapid, high-resolution separation, characterization, and quantitation of analytes. CE has been used for the separation of biopolymers, including acidic carbohydrates. Since CE is basically an analytical method for ions, acidic carbohydrates that give anions in weakly acid, neutral, or alkaline media are often the direct objects of this method. The scope of this review is limited to the use of CE for the analysis of carbohydrates containing carboxylate, sulfate, and phosphate groups as well as neutral carbohydrates that have been derivatized to incorporate strongly acidic functionality, such as sulfonate groups.  相似文献   

9.
Summary The separation of derivatized carbohydrates has been performed by co-electroosmotic capillary electrophoresis. Derivatization was performed by reductive amination of the carbohydrates with ethylp-aminobenzoate or withp-aminobenzonitrile. Separation selectivity is optimized using buffer electrolytes containing high concentrations of borate, organic solvents, and mixtures thereof; this enabled separation of the carbohydrate derivatives then direct UV detection. Co-directional migration of the anionic analytes with the electroosmotic flow was achieved by adding a cationic polyer (hexadimethrine bromide, HDB) to the electrolyte. With this method it is possible to determine specific carbohydrates, such as arabinose, mannose, and glucose, which are difficult to separate by other CE methods. The applicability of the method is demonstrated for the analysis of plant hydrolyzates  相似文献   

10.
李凤  张艳梅  康经武 《色谱》2020,38(5):502-515
人类疾病的发生往往与体内各种酶的功能失调密切相关,因此酶一直是目前新药研发的重要靶标。天然产物是发现新药的宝贵资源,但是由于成分复杂,活性筛选一直受制于耗时费力的分离纯化过程。毛细管电泳(CE)技术由于具有样品和试剂消耗少、灵活多样的分离模式且不受样品基质干扰的特点,可以直接从粗提物开始筛选活性成分,在复杂样品活性筛选中显示出独特的优势。该文综述了近十年来CE在天然产物中酶抑制剂筛选的研究进展。其中重点介绍了CE应用于重要药物靶标,包括转移酶(激酶)、水解酶以及氧化还原酶等方面的应用,总结了用于酶抑制剂筛选的电泳分离模式和酶动力学研究,并展望了CE用于天然产物中活性成分筛选的应用前景。  相似文献   

11.
Wang J  Chen G  Wang M  Chatrathi MP 《The Analyst》2004,129(6):512-515
The preparation of carbon nanotube (CNT)/copper composite electrodes, based on co-mixing CNT and Cu powders within mineral oil, is described. The new composite electrode is used for improved amperometric detection of carbohydrates following their capillary electrophoresis (CE) microchip separations. The CNT/Cu composite electrode detector displays enhanced sensitivity compared to detectors based on copper or CNT alone. The marked catalytic action of the CNT/Cu composite material permits effective low potential (+0.5 V vs. Ag/AgCl) amperometric detection, and is coupled to the renewability, bulk modification and versatility advantages of composite electrodes. The CNT/Cu composite surface also leads to a greater resistance to surface fouling compared to that observed at the copper electrode. Factors affecting the electrocatalytic activity and the CE microchip detection are examined and optimized. The CNT/Cu composite electrode is also shown to be useful for the detection of amino acids as indicated from preliminary results. While the present work has focused on the enhanced CE microchip detection of carbohydrates and amino acids, the CNT/metal-composite electrode route should benefit the detection of other important groups of analytes.  相似文献   

12.
Capillary electrophoresis immunoassay (CEIA) is shown to be substantially more sensitive to the antibody (Ab) reagent quality than are immunosorbent methods such as enzyme-linked immunosorbent assays (ELISA). Cyanine 5 (Cy5)-labeled monoclonal anti-ovalbumin (mAb*) was inactive for CEIA of ovalbumin (Ov), yet was functional in ELISA for Ov. ELISA showed the mAb* was at least ten times less active, accounting for the poor CEIA performance. Labeled polyclonal Ab was inactive for a dye to protein ratio greater than 1.6. An affinity protection chromatography procedure (APC) was developed for Ab labeling, which avoided degradation of the Ab binding site. Ov was covalently bound to cyanogen bromide activated cellulose gel in a column, and used to capture the Ab. The coupling efficiency for Ov to the gel was 74-97%, Ab could then be bound with 95-100% efficiency, and Ab* was recovered in 50% yield following labeling on the column. This procedure was performed successfully in three different laboratories, indicating the robustness of the optimized APC synthetic method. No inactive Ab* could be detected in the APC product. The CEIA detection limit for ovalbumin using APC labeled mAb was 173 nM, when [Ab*] was fixed at 163 nM. The association constants of mAb and mAb* were determined by CEIA.  相似文献   

13.
A sturdy home-built sheathless CE/ESI-QTOF-MS system was developed and optimized for carbohydrate analysis. The interface and employed methodology provided a simple analytical solution to laborious CE/MS interfacing methods and to problems in characterization of complex carbohydrate mixtures that require high-resolution separation of the components. The CE/ESI interface, feasible in any MS laboratory, consists of a one-piece CE column having the CE terminus in-laboratory shaped as a microsprayer and coated with copper. The CE microsprayer was inserted into an in-house made stainless steel clenching device and the whole assembly was mounted onto a quadrupole TOF mass spectrometer. The analytical potential of the interface in terms of suitability, microsprayer performance, copper coat durability, ionization efficiency, spray stability, and sensitivity was tested first on a simple mixture of standard saccharides, which were separated, resolved, and detected with high separation efficiency. The approach was next assessed for the screening of a biological sample, a complex mixture of O-glycosylated sialylated amino acids from urine of a patient suffering from Schindler disease. Preliminary data allow this method to be considered as one of general applicability in structural glycobiology and glycomics and easy to be implemented for proteomic surveys as well.  相似文献   

14.
Hebert NE  Kuhr WG  Brazill SA 《Electrophoresis》2002,23(21):3750-3759
The development of a microchip electrophoresis system involving integrated frequency based electrochemical detection is described. The use of poly(dimethylsiloxane) (PDMS) as the channel substrate greatly simplifies the fabrication process while decreasing cost and time consumption. Characterization of this system is accomplished through the detection of native carbohydrates at planar copper electrodes. Various photolithographic techniques are explored in the optimization of electrode area. Separation efficiency of 1 x 10(5) theoretical plates per meter is demonstrated. Sinusoidal voltammetry utilizes information in the frequency domain to achieve sensitive detection through either of two approaches, maximization of signal or minimization of noise. Mass detection limits (S/N = 3) of less than 200 amol have been accomplished for glucose and sucrose. Sinusoidal voltammetry also facilitated the selective isolation of an analyte signal from a pair of chromatographically unresolved species through the use of phase discrimination.  相似文献   

15.
Xiaowen Ji 《Talanta》2010,82(4):1170-231
A novel strategy for the preparation of in-column adenosine deaminase (ADA) microreactor and rapid screening of enzyme inhibitors in natural extracts was demonstrated. In this approach, ADA was encapsulated in anionic polyelectrolyte alginate that was immobilized on the surface of fused-silica capillary via ionic binding technique with cationic polyelectrolyte polyethylenimine (PEI). On-line enzyme inhibition study was performed by capillary electrophoresis (CE). The substrate and product were baselined separated within 75 s. The enzyme activity was determined by the quantification of peak area of the product. Enzyme inhibition can be read out directly from the reduced peak area of the product in comparison with a reference electropherogram obtained in the absence of any inhibitor. The inhibition percentage was used to evaluate relative activity of ADA microreactor. A known ADA inhibitor, erythro-9-(2-hydroxy-3-nonyl) adenine (EHNA) was employed as a model compound for the validation of the inhibitor screening method, and the screening of ADA inhibitor in 19 traditional Chinese herbal medicines was performed.  相似文献   

16.
A method for the determination of underivatized carbohydrates using capillary electrophoresis (CE) with detection by electrospray ionization-mass spectrometry (ESI-MS) presented. Highly alkaline carrier electrolytes based on volatile organic bases like is diethylamine (DEA) combined with MS detection in the negativ-ion mode proved to be the optimum solution for the separation and detection of these analytes. Optimization of the carrier electrolyte composition has been performed with respect to its pH, ionic strength as well as the addition of an organic modifier. The influence of the DEA concentration in the sheath liquid on parameters like peak shapes or signal-to-noise (S/N) ratios was also investigated. Limits of detection (LOD) were in the range of 0.5-3.0 mgL(-1) and calibration was linear over an order of magnitude for almost all solutes investigated. Finally, the applicability of this method for the analysis of real samples was demonstrated with wine samples.  相似文献   

17.
Analysis of natural food pigments by capillary electrophoresis   总被引:9,自引:0,他引:9  
Lac, cochineal, safflower, gardenia, Monascus and elderberry pigments are used as food color additives in Japan. These natural pigments can be analyzed by capillary electrophoresis (CE). CE has several advantages over thin layer chromatography, gas chromatography and high-performance liquid chromatography, such as low capillary cost, reduced operating costs, small sample amounts, low production of waste materials and short analysis time. CE is shown to be a useful technique for the analysis of these natural food pigments and the pigments extracted from commercial food samples by solid-phase extraction method.  相似文献   

18.
We describe two methods for the analysis of oligosaccharide chains in glycoproteins by high-performance liquid chromatography (HPLC) and high-performance capillary electrophoresis (HPCE).O-andN-glycosidically linked oligosaccharides released from glycoproteins can be identified as their borohydride-reduced forms by anion-exchange HPLC with pulsed amperometric detection.N-Glycosidically linked oligosaccharides can also be analyzed as 2-aminopyridine derivatives by HPCE in direct zone electrophoresis mode in an acidic phosphate buffer and zone electrophoresis mode as borate complexes in an alkaline buffer. We also present a convenient procedure for the analysis of the constituent monosaccharides of these oligosaccharides chains by HPLC based on reversed-phase partition mode as 1-phenyl-3-methyl-5-pyrazolone derivatives.  相似文献   

19.
王丙香  柴微波  唐安娜  丁国生 《色谱》2015,33(4):334-341
手性是自然界的本质属性之一。手性分离分析技术对生命科学、环境科学、生物工程和药物工程等许多学科都具有十分重要的意义。当前,对不同种类手性化合物进行拆分已成为毛细管电泳技术最具特色的研究和应用领域之一。然而,被分析物(或拆分剂)在毛细管内壁的吸附是毛细管电泳手性分离中的常见问题。涂层技术就是采用不同的方法对毛细管内壁进行改性,是抑制非特异性吸附、提高分离效率及分离重现性最简便和最有效的方法。本文主要综述了近十几年来各种涂层技术在毛细管电泳手性分离领域的应用现状,并对毛细管涂层技术今后的发展进行了展望。  相似文献   

20.
Protein phosphorylation is one of the most basic mechanisms for regulating and controlling protein biological activity and function, and it is also a very important posttranslational modification process. Protein phosphorylation participates in and regulates many life activities such as signal transduction, gene expression, cell cycle, and so on. In this paper, we propose a method for the determination of the protein phosphorylation combining capillary electrophoresis (CE) with ATP analog labeling technique. We synthesized two new ATP analogs (ATP-NB and ATP-TATD-NB) functionalized by norbornene. Using Abl kinase as a model, we established a method for the determination of the kinase activity in solution and lysate by CE with laser-induced fluorescence detection (CE-LIF). This method was used to evaluate the efficiencies of kinase inhibitors. The IC50 values obtained are basically consistent with the reports. By D–A reaction (inverse electron demand Diels–Alder reaction) to label TZ-BODIPY fluorescence, we also realized the phosphorylation fluorescence detection of substrate peptide. Then, we used fluorescence confocal microscopy imaging technology to study the phosphorylation of proteins in vivo by the D–A reaction of ATP-NB and TZ-BODIPY. Our preliminary results documented that the combination of CE-LIF with analog ATP-NB labeling technique is an effective strategy for the determination of the protein phosphorylation and the kinase activity and for screening of kinase inhibitors. The D–A reaction of ATP-NB and TZ-BODIPY also laid the foundation for the subsequent in situ study of protein phosphorylation.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号