首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 828 毫秒
1.
Rapid and sensitive indirect competitive enzyme‐linked immunosorbent assays (ic‐ELISA) and gold nanoparticle immunochromatographic strip tests were developed to detect thiamphenicol (TAP), florfenicol (FF) and chloramphenicol (CAP) in milk and honey samples. The generic monoclonal antibody for TAP, FF and CAP was prepared based on a hapten [D ‐threo‐1‐(4‐aminophenyl)‐2‐ dichloroacetylamino‐1,3‐propanediol], and the haptenwas linked to a carrier protein using the diazotization method. After the optimization of several parameters (coating, pH, sodium chloride content and methanol content), the ic‐ELISA was established. The quantitative working range for TAP was 0.11–1.36 ng/mL, with an IC50 of 0.39 ng/mL. The optimized ELISA showed cross‐reactivity to CAP (300%) and FF (15.6%), with IC50 values of 0.13 and 2.5 ng/mL, respectively. The analytical recovery of TAP, FF and CAP in milk and honey samples in the ic‐ELISA ranged from 81.2 to 112.9%. Based on this monoclonal antibody, a rapid and sensitive immunochromatographic test strip was also developed. This strip had a detection limit of 1 ng/mL for TAP, FF and CAP in milk and honey samples. Moreover, the test was completed within 10 min. Our results showed that the proposed ic‐ELISA and immunochromatographic test strip method are highly useful screening tools for TAP, FF and CAP detection in milk and honey samples. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

2.
In this work we obtained polyclonal antibodies for levofloxacin. We synthesized conjugates of levofloxacin with cationized BSA for immunization and with ovalbumin for development of an ELISA for the detection of levofloxacin. The method is characterized by a range of detectable concentrations of 0.03 ng/mL to 0.41 ng /mL and the limit of detectable concentrations is 0.01 ng/mL. We tested the 28 fluoroquinolones for cross reactivity and only ofloxacin (145%), marbofloxacin (82%), ofloxacin in its dextrorotatory form (68%), rufloxacin (67%), and garenoxacin (24%) had cross reactivity. The optimized ELISA technique allowed the detection of levofloxacin in milk from 0.33 ng/mL to 3.34 ng/mL. The recoveries were in the range of 89.5–102% with a relative standard deviation of 3%. We tested 45 real samples of milk purchased in local stores; for 5 of them the results were positive (near 1 ng/mL).  相似文献   

3.
We have developed a heterologous direct competitive enzyme-linked immunosorbent assay (ELISA) and a visual colloidal gold-based immunochromatographic assay (CGIA) for simultaneous determination of ofloxacin, marbofloxacin, and fleroxacin residues in milk using polyclonal antibodies. The half-maximum inhibition concentrations (IC50) of ofloxacin, marbofloxacin, fleroxacin, and limits of detection (LODs; calculated as IC15 values) are between 0.20 and 0.53?ng mL?1, and between 0.02 and 0.05?ng mL?1, respectively. The average recoveries range from of 78% to 113%, and the coefficients of variation of intra- and inter-assays are between 2 and 11%, and 3 to 19%, respectively. The LODs for ofloxacin, marbofloxacin, fleroxacin in milk are between 3.5 and 8.9?ng mL?1. The visual minimum detection limit of the optimized CGIA is 2?ng mL?1 for milk samples. The detection process can be completed within 10?min. The strips can be stored at 4?°C for 8?weeks without significant loss of activity. The results of the analysis of spiked samples showed that the CGIA can be applied to preliminary, fast, and on-site screening of milk samples. The ELISA and CGIA allow for a rapid, sensitive, and low-cost determination of (fluoro)quinolones residues in milk samples.
Figure
A direct competitive enzyme-linked immunosorbent assay (ELISA) and a visual colloidal gold-based immunochromatographic assay (CGIA) are proposed for simultaneous determination of ofloxacin, marbofloxacin, and fleroxacin residues in milk using polyclonal antibodies  相似文献   

4.
Quantum dot (Qdot) nanocrystals have been increasingly used as fluorescence labels in fluoroimmunoassays recently because of their excellent optical characteristics. In this paper, a new monoclonal antibody (MAb) against sulfamethazine (SMZ) was successfully produced and linked to Qdot nanocrystals by covalent coupling. The Qdot–MAb conjugates were characterized by SDS-PAGE and high-performance capillary electrophoresis (HPCE). An enzyme-linked immunosorbent assay (ELISA) method was utilized to evaluate the antigen–antibody binding affinity and then a novel direct competitive fluorescence-linked immunosorbent assay (cFLISA) for the detection of SMZ in milk by using Qdots as fluorescent labels was evaluated. The results showed that the 50% inhibition values (IC50) of the cFLISA were 4.3 ng/mL in milk and 5.2 ng/mL in PBS, and the limits of detection (LODs) were 0.6 ng/mL in milk and 0.4 ng/mL in PBS, respectively. The recoveries of SMZ from spiked milk samples at levels of 10–100 ng/mL ranged from 94 to 106%, with coefficients of variation (CVs) of 2.1–9.2%. Figure Shematic diagram of the direct cFLISA procedure Jianzhong Shen and Fei Xu contributed equally to this work.  相似文献   

5.
In this work, bentonite magnetic nanoparticles synthesized by a typical coprecipitation method were used as the adsorbent for the magnetic solid‐phase extraction of six quinolones (ciprofloxacin, difloxacin, enrofloxacin, norfloxacin, sarafloxacin, and lomefloxacin) from milk samples followed by high‐performance liquid chromatography with fluorimetric detection. Under the optimized conditions, the linear quantitation range for the six quinolones was 0.3–200 ng/mL, and the correlation coefficients of the calibration curves ranged from 0.9994 to 0.9999. The detection limit of the method was 0.1 ng/mL. Recoveries of quinolones from pure and low‐fat spiked milk samples varied from 80.4 to 92.7% and from 81.3 to 93.5%, respectively. These results demonstrated that the proposed method for the determination of six quinolones in milk samples was rapid, reliable, and efficient.  相似文献   

6.
Chuang JC  Van Emon JM  Trejo RM  Durnford J 《Talanta》2011,83(5):658-1323
An enzyme-linked immunosorbent assay (ELISA) method was employed for determination of the pyrethroid biomarker, 3-phenoxybenzoic acid (3-PBA) in human urine samples. The optimized coating antigen concentration was 0.5 ng/mL with a dilution of 1:4000 for the 3-PBA antibody and 1:6000 for the enzyme conjugate. Urine samples were hydrolyzed with concentrated hydrochloric acid; extracted with dichloromethane and solvent-exchanged into a methanol/buffer solution, prior to analysis in a 96-microwell plate immunoassay. Quantitative recoveries of 3-PBA were obtained for fortified urine samples by ELISA (92 ± 18%) as well as by gas chromatography/mass spectrometry (GC/MS) (90 ± 13%). The overall method precision of these samples was within ±20% for both the ELISA and GC/MS methods. Analytical results from over one hundred urine samples showed that the ELISA and GC/MS data were highly correlated, with a correlation coefficient of 0.95. At the 10 ng/mL comparative concentration level, the false positive rate was 0% and the false negative rate was 0.8% for ELISA when using GC/MS as the reference method. The ELISA method has a suitable low detection limit for 3-PBA to assess pyrethroid exposures in non-occupational settings.  相似文献   

7.
Biosensor immunoassay of ivermectin in bovine milk   总被引:4,自引:0,他引:4  
A rapid and sensitive biosensor immunoassay was developed for determination of ivermectin residues in bovine milk. A detection limit of 16.2 ng/mL was achieved. A Biacore optical biosensor based on surface plasmon resonance was used, and a range of extraction techniques was investigated. In the final assay procedure, ivermectin was extracted with acetonitrile followed by C8 solid-phase extraction cleanup. It was proven experimentally that 2 methods of milk storage, freezing or addition of mercury-containing compounds as preservatives, could be used without considerable change in detected concentrations (samples were fortified with ivermectin after storage). The average values for milk samples spiked at 100 and 50 ng/mL concentrations were 102.6 and 51.5 ng/mL, respectively. Extraction and analysis of 20 milk samples were performed within a single working day.  相似文献   

8.
The haptens 4-[[(2,3-dihydro-2,2-dimethyl-7-benzofuranyloxy)carbonyl]-amino]butanoic acid (BFNB) and 6-[((2,3-dihydro-2,2-dimethyl-7-benzofuranyloxy)-carbonylamino]hexanoic acid (BFNH) were synthesized and then used to develop a rapid,specific and sensitive ELISA method to determine residues of the pesticide carbofuran in a variety of matrices. A hybridoma cell line (5D3) producing anti-carbofuran monoclonal antibodies (MAbs) was also established. Based on the MAbs in combination with the heterologous hapten BFNH coupled to either horseradish peroxidase (HRP) or ovalbumin(OVA), four ELISAs (formats I-IV) for the quantification of carbofuran were developed and compared. Among them, the optimized format II (the conjugate-coated direct competitive ELISA) showed the best characteristics, with an IC50 value of 18.49 ng/mL, a limit of detection of 0.11 ng/mL and the shortest assay time (1 h). This ELISA method was then applied to the determinations of carbofuran in environmental water, soil and food samples. The relative standard deviations (R.S.D.s) ranged from 1.8% to 21.3% and the mean recoveries were 104.6%, 108.3%, 106.3% and 100.1% for water, soil, lettuce and cabbage, respectively. Thus, the ELISA method of format II exhibited the potential to develop commercial ELISA kits for a rapid detection of carbofuran for human health and environmental safety.  相似文献   

9.
《Analytical letters》2012,45(12):1617-1631
Four ELISA formats, antigen-coated indirect, antigen-coated direct, antibody-coated, and the secondary antibody-coated, were developed using monoclonal antibody to determine cephalexin. Results showed that the secondary antibody-coated method of ELISA had a better performance in the establishment of standard curves. The optimized secondary antibody-coated ELISA was used to determine cephalexin spiked in pig muscle, pig kidney, pig liver, chicken muscle, chicken liver, and cow's milk. The limits of detection were 0.09 ng/g, 0.15 ng/g, 0.26 ng/g, 0.13 ng/g, 0.19 ng/g, and 0.08 ng/mL in pig muscle, pig kidney, pig liver, chicken muscle chicken liver, and cow's milk, respectively. A mean recovery of 77.2–128.5% and coefficient of variation of 2.6–14.7% were obtained. The results given by the ELISA method were in agreement with those of the LC-MS/MS method, which confirmed the potential of the ELISA method for the monitoring of cephalexin in milk and animal tissues.  相似文献   

10.
A competitive enzyme-linked immunosorbent assay (ELISA) was developed for the quantitative detection of the diethylstilbesterol (DES). Polyclonal rabbit antisera, raised against protein conjugate diethylstilbesterol-mono-caroxyl-propyl-ethyl-bovine-serum-albumin (DES-MCPE-BSA), were utilized in immobilized antibody-based and competitive immunoassays. Assay conditions, including concentrations of antisera and horseradish peroxidase, (HRP)-DES, were optimized. The effects of incubation time, surfactant concentration, ionic strength and pH of the medium were also investigated. The typical calibration curve gave an average IC(50) value of 2.4 ng/mL, calibration range from 0.2 to 30.5 ng/mL and a detection limit of 0.07 ng/mL. The specificity of the assay was tested against DES structurally related compounds, and the assay proved highly selective for DES. Assay performance was validated using spiked chicken meat and liver tissue samples. Moreover, it was compared with liquid chromatography-tandem mass spectrometry. The ion pair for quantification of DES was m/z 267.4/251.4, and the linear equation of DES was y = 0.1033x + 0.0126 (r = 0.9960). The two analytical methods can be applied to monitor DES and other steroid residues in foods.  相似文献   

11.
A highly specific and sensitive indirect competitive enzyme-linked immunosorbent assay (icELISA)was developed for the first time for the detection of chrysoidine, a dye banned in soybean milk film. Two haptens with different spacer arms were synthesized to produce antibodies. Both homologous and heterologous immunoassay formats were compared to enhance the icELISA sensitivity. The heterologous icELISA exhibited better performance, with an IC(50) (50% inhibitory concentration) of 0.33 ng/mL, a limit of detection (LOD, 10% inhibitory concentration) of 0.04 ng/mL, and a limit of quantitation (LOQ, 20%-80% inhibitory concentration) from 0.09 to 4.9 ng/mL. The developed icELISA was high sensitive and specific, and was applied to determine chrysoidine in fortified soybean milk film samples. The results were in good agreement with that obtained by high-performance liquid chromatography (HPLC) analyses.  相似文献   

12.
Okadaic acid (OA) is a lipophilic marine biotoxin. In this study, OA was coupled with the carrier proteins keyhole limpet hemocyanin and bovine serum albumin as immunity and detection antigens by an active ester method. The polyclonal antibody against OA was prepared successfully, an indirect competitive ELISA (ciELISA) developed for the detection of OA in shellfish, and the reactive conditions of ciELISA optimized. The LOD (15% inhibition concentration) for the microwell plates was 1.28 +/- 0.38 ng/mL, corresponding to 12.8 +/- 3.8 ng/g. Two extraction methods were used to remove shellfish matrix interference with high recovery of spiked samples, and the methanol extraction of shellfish mussel was analyzed after dilution in phosphate-buffered saline. For validation of the optimized ciELISA, spiked and natural samples were analyzed by ciELISA, and HPLC with fluorescence detection. The correlation of linear regression equation was y = 1.0064x - 10.234, and the correlation coefficient was 0.9347. From the results of the comparative study, the established ciELISA assay using polyclonal antibody against OA could be used in preliminary screening of suspicious shellfish samples.  相似文献   

13.
In this paper, a method of simultaneous immunizing BALB/c mice with staphylococcal enterotoxin (SE) A and B (SEA and SEB) to prepare a monoclonal antibody (3F2) for detecting both of SEA and SEB was developed. The results showed that antibody 3F2 had high titers against both SEA and SEB by enzyme-linked immunosorbent assay (ELISA). The sensitivities of 3F2 to SEA and SEB detected by ELISA were 133.2 and 82.5 ng/mL, respectively, and the detection limits for the two enterotoxins were about 1 ng/mL. The antibody 3F2 had high specificities and affinities to both SEA and SEB, and had no cross-reaction with SEC1, bovine serum albumin, and ovalbumin. SEs-free skimmed milk samples were spiked with different concentrations of SEA, SEB, or both of them, respectively. Average recoveries of SEA and SEB from the spiked samples were all nearly between 82% and 104%. The result suggested that one cell fusion with simultaneous immunization by multiple antigen to prepare monoclonal antibody against them was possible, simple, and economic. The monoclonal antibody could be used in simultaneous detecting multifarious SEs.  相似文献   

14.
Watanabe E  Baba K  Miyake S 《Talanta》2011,84(4):601-1111
The analytical performance of a kit-based enzyme-linked immunosorbent assay (ELISA) for the determination of a neonicotinoid insecticide dinotefuran residue in rice samples is addressed. The sensitivity (I50 value) was 5.4 ng/mL, with the limit of detection, 0.6 ng/mL and the dynamic range from 1.0 to 30 ng/mL. The ELISA showed substantially high specificity toward dinotefuran besides clothianidin (184%). For rice samples, dinotefuran was extracted with methanol and the extracts were directly determined with the ELISA because of no significant matrix interference. Good recoveries were observed and ranged from 92.5% to 113.2% with coefficients of variation below 10%. The results obtained with the ELISA correlated well with those by the HPLC method for rice samples (r > 0.98). These findings strongly indicate that the evaluated and validated ELISA has a potential utility in a quick, simple, and reliable residue analysis, especially a screening method before shipment contributing to food safety.  相似文献   

15.
A simple, rapid, and sensitive method for the determination of naproxen and ibuprofen in complex biological and water matrices (cow milk, human urine, river, and well water samples) has been developed using ultrasound‐assisted magnetic dispersive solid‐phase microextraction. Magnetic ethylendiamine‐functionalized graphene oxide nanocomposite was synthesized and used as a novel adsorbent for the microextraction process and showed great adsorptive ability toward these analytes. Different parameters affecting the microextraction were optimized with the aid of the experimental design approach. A Plackett–Burman screening design was used to study the main variables affecting the microextraction process, and the Box–Behnken optimization design was used to optimize the previously selected variables for extraction of naproxen and ibuprofen. The optimized technique provides good repeatability (relative standard deviations of the intraday precision 3.1 and 3.3, interday precision of 5.6 and 6.1%), linearity (0.1–500 and 0.3–650 ng/mL), low limits of detection (0.03 and 0.1 ng/mL), and a high enrichment factor (168 and 146) for naproxen and ibuprofen, respectively. The proposed method can be successfully applied in routine analysis for determination of naproxen and ibuprofen in cow milk, human urine, and real water samples.  相似文献   

16.
A previously developed fluorescence sensing platform, combining spatial illumination using electroluminescence (EL) semiconductor strips with charge coupled device (CCD)-based detection (EL-CCD), was adapted to a new 96-well chip for colorimetric immunological assays, enhancing the capabilities of the EL-CCD platform. The modified system was demonstrated using a colorimetric-based enzyme linked immunosorbent assay (ELISA) for detection of staphylococcal enterotoxin B (SEB). Limits of detection (LODs) of 3.9 ng/mL (±2.4 ng/mL) SEB were determined with the ELISA chip measured using the EL-CCD platform, following a standard 4-h ELISA protocol. The LODs were comparable to those obtained using standard 96-well ELISA plates measured using a standard laboratory 96-well plate reader. The miniature 96-well ELISA chip however required as little as 5-μL samples, representing a tenfold reduction in sample volume compared to a standard 96-well ELISA plates. The ELISA chip also demonstrated detection of SEB spiked into various food matrices (milk, mushrooms, and mayonnaise) using limited-to-no sample preparation, with LODs ranging from 3.9 to 18.5 ng/mL depending on the matrix. The EL-CCD platform is versatile, capable of multi-mode detection (e.g., fluorescent and colorimetric along with solution and solid phase assays), and could readily be applied to other field portable or point-of-care applications. Figure Detection of SEB using miniature ELISA chips coupled with a portable electroluminiscent-charge couple device (EL-CCD) detection system. Electronic supplementary material  The online version of this article (doi:) contains supplementary material, which is available to authorized users.  相似文献   

17.
A disposable electrochemical enzyme-linked immunosorbent assay (ELISA) for the detection of two macrolides (erythromycin and tylosin) in bovine muscle was developed using a screen printed electrode (SPE) system as a differential pulse voltammetry (DPV) transducer with mouse anti-erythromycin (and anti-tylosin) monoclonal antibodies (MAb) serving as molecular recognition elements. The immunochemical system makes use of the competition assay principle, and employs an erythromycin (or tylosin)-BSA conjugate as coating molecule. After competition between free and coated analyte for the antibodies, the activity of the alkaline phosphatase labelled antiglobulins was measured electrochemically using 1-naphthylphosphate as substrate. Using standard solutions of erythromycin and tylosin, the detection limit of the assay was 0.2 ng mL(-1) determined to be for erythromycin and 2.0 ng mL(-1) for tylosin, while the sensitivity (25% inhibition concentration) was 1.0 ng mL(-1) for erythromycin and 3.0 ng mL(-1) for tylosin. The suitability of the assay for quantification of erythromycin and tylosin in bovine muscle was also studied. Spiked and real samples were analysed using the immunosensor system developed here. The ELISA showed precision values (relative standard deviation, RSD%) ranging from 4 to 9% for erythromycin and from 8 to 15% for tylosin; the accuracy (relative error, RE%) ranged from -11 to 6% and from -4 to 12% for erythromycin and tylosin, respectively. Results obtained on real samples were confirmed by micro-liquid chromatography coupled on line with tandem mass spectrometry (micro-LC-MS-MS), using an atmospheric pressure ionisation (API) source and an ionspray (IS) interface. The latter provides unequivocal identification and quantification of the analytes at the level of interest.  相似文献   

18.
A simple synthetic method for haptens of organophosphorus (OP) pesticides with a spacer arm (aminocarboxylic acid) attached at the pesticide thiophosphate group was developed. While the previous synthetic approach for this type of haptens requires seven steps, the present method involves only two steps. Using this method, five haptens of fenitrothion were synthesized and two of them were conjugated to proteins to be used as immunogens for production of polyclonal antibodies. Using the antibodies and a coating antigen, an indirect competitive enzyme-linked immunosorbent assay (ELISA) for fenitrothion was developed, which showed an IC50 of 3.7 ng/mL with a detection limit of 0.5 ng/mL. A direct competitive ELISA using an enzyme tracer was also developed, which showed an IC50 of 5.6 ng/mL with a detection limit of 0.4 ng/mL. The antibodies in both assays showed negligible cross-reactivity with other OP pesticides except with the insecticide parathion-methyl only in the direct ELISA. Recoveries of fenitrothion from fortified lettuce and rice samples ranged 84-116 and 100-121%, respectively.  相似文献   

19.
采用高效化学发光试剂3-(2'-螺旋金刚烷)-4-甲氧基-4-(3"-羟基)苯-1,2-二氧杂环丁烷磷酸(AMPPD)作为检测底物, 并将传统的ELISA两步双抗夹心法改为一步法, 得到了高灵敏测定人血清中心肌肌钙蛋白I(cTnI)的化学发光酶免疫分析优化条件. 采用单因素变化法和方阵滴定法得到的最佳实验条件为: 捕获抗体包被浓度为10.0 μg/mL, 以pH=7.0的PBS作为免疫反应缓冲底液, 以含质量分数为1.0%的BSA pH=9.6的碳酸盐溶液缓冲液, 于4 ℃封闭过夜, 生物素-检测抗体(Biotin-IgG2)以及碱性磷酸酶-亲和素(ALP-Avidin)结合物均采用1:2000稀释度, 免疫反应条件为37 ℃, 孵育时间60 min, 以去离子水作为洗涤剂, 以1:100稀释的AMPPD作为发光反应底物, 发光反应时间10 min(37 ℃). 检出限为0.02 ng/mL, 比现行ELISA法灵敏度提高一个数量级; 测定周期约75 min, 比两步法ELISA快得多; 线性范围(0.04~36.20 ng/mL)比ELISA法扩宽了两个数量级; 加标回收率97.5%~102.8%, 对标准样品的测定结果与用ELISA法的测定结果吻合; 重复性好, 3个样品批内变异系数均小于8.5%(n=12).  相似文献   

20.
Two different immunoassay methods,competitive indirect enzyme-linked immunosorbent assay (CI-ELISA) and amplificative competitive indirect ELISA(ACI-ELISA) using biotin-avidin complex system were studied to detect rhEPO.The linear ranges were 50-20000ng/mL and 10-50000ng/mL for CI-ELISA and ACI-ELISA,respectively.The low detection limits of CI-ELISA and ACI-ELISA were 62.8ng/mL and 8.5ng/mL,respectively.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号