1.
To understand the chromatographic process as a whole, whether it be for gas chromatography (GC), liquid chromatography (LC), or supercritical fluid chromatography (SFC), one needs to know the chemical and physical nature of the mobile and stationary phases and also the interactions that take place between analytes (solutes) and the two phases. An approach towards Investigating the ways that stationary and mobile phases contribute to chromatographic retention Involves exploring the effects of solvent polarity on the strength of the mobile phase. In SFC this could involve determining the polarity of several different modifier/carbon dioxide mobile phases. In this paper, the use of a solvatochromic indicator to learn more about the effects of SFC modifier/mobile phase polarity will be investigated and discussed using several different modifiers and a diolmodified silica column.  相似文献   

2.
酚类环境雌激素的色谱分析方法   总被引:2,自引:4,他引:2  
综述了近年来酚类环境雌激素的色谱分析研究进展,包括气相色谱和气质联用,高效液相色谱和各种检测器联用技术。比较了使用气相色谱和液相色谱两种方法的优缺点,并对环境雌激素样品预处理作了介绍。  相似文献   

3.
Chromatography with a supercritical fluid as the mobile phase was suggested more than four decades ago (Klesper, E., Corwin, A. H., Turner, D. A., J. Org. Chem. 1962, 27, 700-701). Supercritical fluid chromatography (SFC) is basically a hybrid of GC and LC that eases the resolution of a mixture of compounds not conveniently resolved by either GC or LC. The mobile phases for SFC have low viscosities and high diffusion coefficients compared to those for HPLC and allow for high efficiency separations. SFC uses supercritical fluid as the mobile phase, polar organic solvents as the modifiers in conjunction with acidic/basic compounds as additives to run the chromatographic process like in HPLC. In many applications, SFC-based methods are advantageous over HPLC-based methods as a separation tool in terms of efficiency and economical impact perspectives. Today, the availability of commercial hardware and API interfaces with a mass spectrometer makes SFC even more widely applicable for chemical analysis in many research fields. This review summarizes a variety of novel SFC-MS methods for chemical analysis that have been reported in the peer-reviewed publications.  相似文献   

4.
Comprehensive two-dimensional (2D) chromatographic techniques can be considered innovative methods, only quite recently developed. Since their introduction to the chromatographic community, these techniques have been used in several fields and have gained an excellent reputation as valuable and powerful analytical tools. The revolutionary aspect of comprehensive multidimensional (MD) techniques, in respect to classical MD chromatography, is that the entire sample is subjected to the 2D advantage. The resulting unprecedented separating capacity makes these approaches prime choices when analysts are challenged with highly complex mixtures. Furthermore, in the case of automated systems, instrumental analysis times are roughly the same as in monodimensional applications. The present review reports various comprehensive chromatographic applications on different food matrices. The GC x GC section highlights two fundamental aspects for component separation/identification: the exceptional peak capacity and the formation of group types on the 2D space plane. The LC x LC section reports the employment in food analysis of a recently developed multidimensional normal-phase (NP)-reversed-phase (RP) high performance liquid chromatography (HPLC) system. Also reported are comprehensive LC x GC and packed column supercritical fluid chromatography (pSFC x pSFC) applications in this field.  相似文献   

5.
The various forms of chromatography are primarily determined by differences in the physical state of the mobile phases. The main chromatographic categories include gas chromatography (GC), liquid chromatography, and supercritical fluid chromatography. Adjusting a temperature and pressure will change the mobile phase from liquid to supercritical fluid to gas, with concomitant changes in their physical properties. In this paper, the technique transition-phase chromatography (TPC) is described. In TPC, different mobile phase conditions exist inside the column. This phase transformation within the column results in huge differences in density, solvating power, viscosity, diffusivity, and, as a consequence, in the chromatographic properties of the mobile phase. TPC experiments using capillary columns packed in our laboratory have shown that when the mobile phase is transformed from supercritical fluid to gas, high column efficiencies can be achieved. The transition from supercritical fluid to gas (also called solvating GC), a particular case of the TPC, is evaluated for the separation of complex real samples (environmental, food, and fuels).  相似文献   

6.
Several recently developed analytical techniques, based on high-end mass spectrometry and chromatography, for dealing with challenges in petroleum characterization are reported. Folded flight path time-of-flight mass spectrometry provides resolving power up to 100000, enabling accurate mass measurement for molecular formula determination with high confidence. Atmospheric pressure chemical ionization (APCI) can be used in both gas chromatography (GC, as APGC) and liquid chromatography (LC) for analyzing non-polar hydrocarbons as well as polar compounds. The improvement in chromatography facilitates the mass spectrometric analysis through online coupling. Comprehensive two-dimensional gas chromatography (GC×GC) resolves overlapping components, rendering accurate identification and quantitation. Supercritical fluid extraction has been developed as an alternative method to replace traditional solvent extraction methods and eliminate the use of large volumes of solvents that can be harmful to health and environment. Supercritical fluid chromatography (SFC) has been developed as a convergence of GC and LC chromatographic techniques. The use of SFC for heavy oils and residua has been demonstrated. Prospective developments in the use of mass spectrometric and chromatographic methods for petroleum characterization are also described.  相似文献   

7.
This work describes the analysis of a pyrolysis product of a lignite sample obtained from the Turkish Goynuk reserve. The aliphatic, aromatic and polar compounds present in the tar are separated and identified by various chromatographic techniques: Capillary gas chromatography/mass spectrometry (GC/MS), on-line high performance microbore liquid chromatography/capillary gas chromatography (LC/GC) and capillary supercritical fluid chromatography (SFC). The suitability of each technique for this particular application is discussed, and semi-quantitative results are presented for the major components detected.  相似文献   

8.
Ionic liquids (ILs), as separation media, have made significant contributions in the past decades in advancing research in gas chromatography (GC), liquid chromatography (LC), and capillary electrophoresis (CE). This review, covering reports published from the mid 1980s to early 2007, shows how ILs have been used so far in separation science, originally primarily as GC stationary phases and later as mobile phase additives (both millimolar and major percent levels) for LC and CE. Representative GC and LC chromatograms as well as CE electropherograms are shown. In addition, the very recent findings on the development of ionic liquids with surfactant properties and its applications for chiral and achiral analysis are discussed.  相似文献   

9.
A modified loop-type interface is decribed which uses two 6-way valves and concurrent eluent evaporation to perform an on-line transfer and simultaneous gas chromatographic analysis of two different fractions pre-separated by liquid chromatography. The interface is used to simultaneously analyze aliphatic alcohols and sterols present in olive oil. LC pre-separation is carried out using a normal phase column (20 cm × 0.21 cm i.d.) and hexane-isopropanol (99:1) as a mobile phase at a flow of 0.2 ml/min; for the GC analysis a 5 % phenyl, 95 % dimethyl siloxane (25 m × 0.32 mm i.d., 0.4 μm film thickness) column is used.  相似文献   

10.
Characterization of complex petrochemical samples has been a classical subject of comprehensive two-dimensional (2D) gas chromatography (GC x GC). Macroscopic properties of these samples can be described accurately by separation of compounds in classes of identical molecular functionality. Ring structures in the carbon backbone of these compounds, which can be divided in saturated and unsaturated, are amongst the foremost functionalities affecting samples properties. Unfortunately, GC x GC tuned for separation of both saturated and unsaturated ring structures is likely to result in convoluted chromatograms when a distribution of both molecular properties is present in the sample. An independent liquid chromatographic (LC) separation preceding GC x GC could be used to resolve the mixture based on unsaturated rings, allowing saturated rings to be resolved separately in the GC x GC separation. This three-dimensional separation (abbreviated LC-GC x GC) was performed after rigorous evaluation of LC as part of a multidimensional separation using LC x GC. Group-type separation was achieved using this separation for components with either saturated or unsaturated rings. Results of this separation were used to compare information obtained by GC x GC with LC-GC x GC.  相似文献   

11.
A multidimensional, on-line coupled liquid chromatographic/gas chromatographic system was developed for the quantification of polycyclic aromatic hydrocarbons (PAHs). A two-dimensional liquid chromatographic system (2D-liquid chromatography (LC)), with three columns having different selectivities, was connected on-line to a two-dimensional gas chromatographic system (2D-gas chromatography (GC)). Samples were cleaned up by combining normal elution and column back-flush of the LC columns to selectively remove matrix constituents and isolate well-defined, PAH enriched fractions. Using this system, the sequential removal of polar, mono/diaromatic, olefinic and alkane compounds from crude extracts was achieved. The LC/GC coupling was performed using a fused silica transfer line into a programmable temperature vaporizer (PTV) GC injector. Using the PTV in the solvent vent mode, excess solvent was removed and the enriched PAH sample extract was injected into the GC. The 2D-GC setup consisted of two capillary columns with different stationary phase selectivities. Heart-cutting of selected PAH compounds in the first GC column (first dimension) and transfer of these to the second GC column (second dimension) increased the baseline resolutions of closely eluting PAHs. The on-line system was validated using the standard reference materials SRM 1649a (urban dust) and SRM 1975 (diesel particulate extract). The PAH concentrations measured were comparable to the certified values and the fully automated LC/GC system performed the clean-up, separation and detection of PAHs in 16 extracts in less than 24 h. The multidimensional, on-line 2D-LC/2D-GC system eliminated manual handling of the sample extracts and minimised the risk of sample loss and contamination, while increasing accuracy and precision.
Figure
Scheme of the 2D-LC/2D-GC system  相似文献   

12.
The scope of compound-specific stable isotope analysis has recently been increased with the development of the LC IsoLink which interfaces high-performance liquid chromatography (HPLC) and isotope ratio mass spectrometry (IRMS) to provide online LC/IRMS. This enables isotopic measurement of non-volatile compounds previously not amenable to compound-specific analysis or requiring substantial modification for gas chromatography/combustion/isotope ratio mass spectrometry (GC/C/IRMS), which results in reduced precision. Amino acids are an example of such compounds.We present a new chromatographic method for the HPLC separation of underivatized amino acids using an acidic, aqueous mobile phase in conjunction with a mixed-mode stationary phase that can be interfaced with the LC IsoLink for compound-specific delta13C analysis. The method utilizes a reversed-phase Primesep-A column with embedded, ionizable, functional groups providing the capability for ion-exchange and hydrophobic interactions. Baseline separation of 15 amino acids and their carbon isotope values are reported with an average standard deviation of 0.18 per thousand (n = 6). In addition delta13C values of 18 amino acids are determined from modern protein and archaeological bone collagen hydrolysates, demonstrating the potential of this method for compound-specific applications in a number of fields including metabolic, ecological and palaeodietary studies.  相似文献   

13.
Hydrogen/deuterium exchange monitored by mass spectrometry is an important non-perturbing tool to study protein structure and protein–protein interactions. However, water in the reversed-phase liquid chromatography mobile phase leads to back-exchange of D for H during chromatographic separation of proteolytic peptides following H/D exchange, resulting in incorrect identification of fast-exchanging hydrogens as unexchanged hydrogens. Previously, fast high-performance liquid chromatography (HPLC) and supercritical fluid chromatography have been shown to decrease back-exchange. Here, we show that replacement of up to 40% of the water in the LC mobile phase by the modifiers, dimethylformamide (DMF) and N-methylpyrrolidone (NMP) (i.e., polar organic modifiers that lack rapid exchanging hydrogens), significantly reduces back-exchange. On-line LC micro-ESI FT-ICR MS resolves overlapped proteolytic peptide isotopic distributions, allowing for quantitative determination of the extent of back-exchange. The DMF modified solvent composition also improves chromatographic separation while reducing back-exchange relative to conventional solvent.  相似文献   

14.
王少芬  魏建谟 《分析化学》2001,29(6):725-730
超临界流体色谱(SFC)在色谱分离过程中能在较低的温度下分析对热不稳定性的化合物,包括金属络合物和金属有机化合物。本文总结了近来文献报道的各种过渡金属、重金属、镧系和锕系以及铅、汞和锡的金属有机化合物的SFC分离,还讨论了SFC检测系统和金属有机化合物的溶解度的测定。  相似文献   

15.
Theoretical aspects of temperature in liquid chromatography (LC) have mostly been studied to elucidate changes in retention behavior of small and large molecules in various solvents. That temperature also plays a significant role in chromatographic performance is less known. Kinetic plots are an established tool to predict chromatographic performance in terms of speed and efficiency that can be obtained with a certain particle size at the maximum attainable column pressure. In this paper, temperature effects on mobile phase viscosity and analyte diffusion are incorporated in these plots to prove that superior performances are within experimental reach for conventional LC columns and equipment. Verification of the modified kinetic plots with experimental data points is presented.  相似文献   

16.
Inverse gas chromatography (IGC) is a versatile, powerful, sensitive and relatively fast technique for characterizing the physicochemical properties of materials. Due to its applicability in determining surface properties of solids in any form such as films, fibres and powders of both crystalline and amorphous structures, IGC became a popular technique for surface characterization, used extensively soon after its development. One of the most appealing features of IGC that led to its popularity among analytical scientists in early years was its similarity in principle to analytical gas chromatography (GC). The main aspect which distinguishes IGC experiments from conventional GC is the role of mobile and stationary phases. Contrary to conventional GC, the material under investigation is placed in the chromatographic column and a known probe vapour is used to provide information on the surface.  相似文献   

17.
金属有机框架(MOFs)是由金属离子或金属簇与有机配体通过配位作用自组装形成的一类新型多孔材料. MOFs具有独特的拓扑结构、丰富的孔隙结构、可调的孔道尺寸、巨大的比表面积以及灵活的表面修饰等特征,是色谱分离领域颇受关注的一类新型固定相. 综述了近几年MOFs材料作为固定相在气相色谱、液相色谱及手性拆分等领域应用的研究进展,展现MOFs材料在色谱分离领域的优异性能和应用潜力,并对MOFs材料在色谱固定相领域今后的发展进行了展望.  相似文献   

18.
Steroid sex hormones and related synthetic compounds have been shown to provoke alarming estrogenic effects in aquatic organisms, such as feminization, at very low concentrations (ng/L or pg/L). In this work, different chromatographic techniques, namely, gas chromatography/mass spectrometry (GC/MS), liquid chromatography/mass spectrometry (LC/MS) and liquid chromatography/tandem mass spectrometry (LC/MS/MS), are discussed for the analysis of estrogens, both free and conjugated, and progestogens, and the sensitivities achieved with the various techniques are inter-compared. GC/MS analyses are usually carried out after derivatization of the analytes with bis(trimethylsilyl)trifluoroacetamide (BSTFA). For LC/MS and LC/MS/MS analyses, different instruments, ionization techniques (electrospray (ESI) and atmospheric pressure chemical ionization (APCI)), ionization modes (negative ion (NI) and positive ion (PI)) and monitoring modes (selected ion monitoring (SIM) and selected reaction monitoring (SRM)) are generally employed. Based on sensitivity and selectivity, LC/ESI-MS/MS is generally the method of choice for determination of estrogens in the NI mode and of progestogens in the PI mode (instrumental detection limits (IDLs) 0.1-10 ng/mL). IDLs achieved by LC/ESI-MS in the SIM mode and by LC/ESI-MS/MS in the SRM mode were, in general, comparable, although the selectivity of the latter is significantly higher and essential to avoid false positive determinations in the analysis of real samples. Conclusions and future perspectives are outlined.  相似文献   

19.
The analytical behaviour of the relatively new pyrethroid insecticide tralomethrin has been evaluated by using gas chromatography (GC) with electron-capture and mass spectrometry (MS) detectors, and liquid chromatography (LC)-atmospheric pressure ionization mass spectrometry with electrospray interfacing. Under the GC conditions commonly used in pesticide residue analysis, it was found that tralomethrin is transformed into deltamethrin (in a reproducible way) in the injector port of the GC system. Results obtained in this work indicate that the GC multiresidue methodologies routinely applied in the analysis of pyrethroid pesticides in foods cannot distinguish between these two pesticides, and the chromatographic signal obtained at the retention time of deltamethrin/tralomethrin can be really quantified as either deltamethrin or tralomethrin, including when it is confirmed as deltamethrin by MS. Under the LC-MS conditions assessed in this work, deltamethrin and the two diasteroisomers of tralomethrin were well separated and identified.  相似文献   

20.