首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到19条相似文献,搜索用时 78 毫秒
1.
气相色谱-串联质谱法测定土壤中的邻苯二甲酸酯   总被引:4,自引:0,他引:4  
Li H  Tian F  Ren X  Wang X 《色谱》2011,29(6):563-566
建立了土壤中6种邻苯二甲酸酯的气相色谱-串联质谱(GC-MS/MS)分析方法。土壤样品用超声提取,以二氯甲烷-丙酮(1:1, v/v)混合溶液为提取溶剂,提取液经Florisil小柱净化后,经HP-5MS色谱柱(30 m×0.25 mm×0.25 μm)分离,利用MS/MS的多反应监测(MRM)模式进行定性和定量。结果表明本方法可对样品中的邻苯二甲酸酯进行分析,在10~1000 μg/L质量浓度范围内,线性关系良好,相关系数为0.9973~0.9976;6种邻苯二甲酸酯的相对标准偏差(RSD)不大于14.3%, 2 μg/kg和10 μg/kg两个加标水平的回收率为72.9%~106.2%; 6种目标化合物的检出限为0.1~0.5 μg/kg。该方法快速准确、背景干扰较少、分析灵敏度较高,适用于土壤样品中邻苯二甲酸酯的分析。  相似文献   

2.
气相色谱-串联质谱法测定土壤中的有机氯农药   总被引:9,自引:3,他引:9  
贾丽娟  邓芸芸 《色谱》2008,26(6):697-703
建立了气相色谱-串联质谱测定土壤中有机氯农药的方法,同时测定了上海郊区的20个农业土壤。样品前处理包括加速溶剂萃取(弗罗里硅土池内净化)和凝胶渗透色谱净化在线浓缩。采用多反应监测模式的气相色谱-串联质谱分析有机氯农药,降低了背景干扰,提高了分析的灵敏度。在0.001~2 mg/L的质量浓度范围内,各种农药标准溶液的线性相关系数均大于0.995。分别向3种实际土壤样品中添加农药的混合标准溶液,所测定的有机氯农药的平均回收率为65.9%~140.0%,相对标准偏差为1.5%~20.3%(n=5)。有机氯农药的检出限(S/N=3)为0.1~3.0 μg/kg,定量限(S/N=10)为0.3~8.0 μg/kg。实际土壤样品的测定结果表明:六六六(1.82~3.70 μg/kg)和六氯苯(0.94~9.8 μg/kg)有少量检出,滴滴涕的检出率高达100%,其含量范围较宽(1.08~308.76 μg/kg),平均值为53.28 μg/kg,其中85%的样品中滴滴涕含量/(滴滴伊+滴滴滴)含量的比值小于1,表明滴滴涕主要来自于早期的使用  相似文献   

3.
气相色谱-串联质谱法测定沉积物中有机磷酸酯   总被引:3,自引:0,他引:3  
比较了不同提取方法、净化方法对沉积物样品中有机磷酸酯(Organophosphate esters,OPEs)的富集、净化效果,建立了气相色谱-串联质谱法(GC-MS/MS)检测沉积物中8种OPEs的分析方法.用20 mL正己烷-丙酮混合液(1∶1,V/V)、涡流振荡+超声提取两次,Florisil固相萃取柱净化、8 mL乙酸乙酯洗脱,浓缩后将溶剂置换成正己烷,采用DB-5MS毛细管柱(30 m×0.25 mm ×0.25 μm)进行分离,质谱检测器在选择反应监测模式(SRM)下进行分析,内标法定量.结果表明,此前处理方法操作简单、溶剂耗量少;在3个添加浓度水平下,OPEs(除TEP外)的回收率在80%~ 120%之间,检出限为0.31 ~ 65 ng/L,且有良好的精密度与准确度.  相似文献   

4.
建立了茶叶中苦参碱残留检测的两种前处理方法,比较了液相色谱-串联质谱(LC-MS/MS)与气相色谱-串联质谱(GC-MS/MS)检测茶叶中苦参碱残留量分析方法的适用性。结果表明,在添加标准样品10~100μg/kg 3个水平时,两种前处理方法的回收率和精密度无显著差别;GC-MS/MS和LC-MS/MS回收率分别为81%~85%、82%~86%,相对标准偏差(RSD)分别为4.6%~11.5%和2.9%~4.2%。结果表明两种样品前处理方法以及LC-MS/MS与GC-MS/MS检测均能满足茶叶中苦参碱残留量的测定,但采用前处理方法二,LC-MS/MS检测茶叶中苦参碱残留更具优势。  相似文献   

5.
本文建立了气相色谱-质谱(GC-MS)联用测定艾叶中持久性有机污染物的分析方法。样品以正己烷和丙酮为提取剂,经提取液浓H2SO4和硅胶柱净化后,通过GC-MS联用测定19种有机氯农药和多氯联苯残留。结果表明,在25、50、100ng/g添加水平下平均回收率分别为71.0%~93.6%、79.7%~105.9%、85.1%~108.7%,相对标准偏差(RSD)分别为2.4%~11.6%、1.1%~8.6%、0.9%~7.5%。使用该方法分析不同批次的艾叶发现主要残留物为有机氯农药,其次是低氯取代的多氯联苯。方法简便高效,精密度好,可用于艾叶中持久性有机氯污染物的分析。  相似文献   

6.
采用稳定同位素标记的多氯萘(PCNs)同类物为内标,建立了同位素稀释气相色谱/三重四极杆串联质谱技术测定环境样品中20种高关注的PCNs同类物的方法。结果表明:PCNs同类物的校正曲线在0.5~200 μg/L范围内线性良好(R2>0.99),检出限(LOD)为0.04~0.48 μg/L,相对标准偏差(RSD)小于15%。采用基质加标法评价该方法对实际环境样品中PCNs测定的回收率为45.2%~87.9%。为验证方法的适用性,以河流沉积物和再生铝冶炼排放的烟道气样品为对象,利用所建立的方法测定了20种PCNs同类物,并将结果与高分辨气相色谱/高分辨质谱方法的测定结果进行了比对,两种方法测定结果的RSD为0.5%~41.4%,表明所建立的同位素稀释气相色谱/三重四极杆串联质谱方法可用于实际环境样品中PCNs的定性、定量分析。  相似文献   

7.
气相色谱–串联质谱(GC–MS/MS)因其强抗干扰能力和高灵敏度的特性,在环境监测领域得到广泛应用。综述了近年来GC–MS/MS技术在环境监测中关于空气、水、土壤及沉积物中污染物检测工作中的应用,并对该方法的性能进行了评价;根据环境监测的特点和需求,对GC–MS/MS技术在环境检测中的应用进行了展望。  相似文献   

8.
建立了基质固相分散技术-气相色谱串联质谱法(MSPD-GC-QQQ-MS/MS)同时测定孕妇血清中22种持久性有机污染物(艾氏剂、狄氏剂、七氯、灭蚁灵、六六六、多氯联苯和滴滴涕)的方法.血清样品与C18吸附剂混合净化,正己烷溶液洗脱,GC-QQQ-MS/MS测定.采用Agilent J&W DB-35ms (30 m×0.25 mm×0.25 μm)分离,正电子离子源(EI+)模式电离,多反应监测模式(MRM)下进行测定,外标法定量.结果表明,在1.0~1000.0 ng/mL的范围内,22种持久性有机污染物的相关系数均大于0.99;在2.0和20.0 ng/mL的添加水平下,所有持久性有机污染物回收率均在75%~ 115%之间,方法定量限均≤0.15 ng/mL.在比较基质固相分散(MSPD)、液液萃取(LLE)和固相萃取(SPE)提取和净化实际加标血清样品时,MSPD方法的结果中位数更接近真实值,且离散程度最小.本方法适用于人类血清中多种持久性有机物的定性和定量分析.  相似文献   

9.
建立了改良的QuEChERS法,结合气相色谱-串联质谱(GC-MS/MS)检测土壤中17种邻苯二甲酸酯的分析方法.样品用乙腈水溶液提取,NaCl盐析分层,上清液采用磁性氧化石墨烯(Fe3O4-GO)、N-丙基乙二胺(PSA)和无水MgSO4吸附剂分散固相萃取净化,质谱以多反应监测(MRM)模式测定,外标法定量.结果 表...  相似文献   

10.
建立了通过溶解-沉淀法进行样品预处理,结合气相色谱-电子轰击源质谱仪(GC-EI/MS)检测5种不同类型胶黏剂中得克隆(DP,含syn-DP和anti-DP同分异构体)含量的分析方法。前处理结果表明,以乙酸丁酯溶解胶黏剂后定量加入甲醇或异辛烷,胶黏剂中的高聚物在混合液中析出而形成相分离,经离心后高聚物的去除率在85.3%~96.2%范围内,具有较好的净化效果。通过优化仪器检测参数,syn-DP和anti-DP的质量浓度在0.60~18.0 mg·L-1范围内与响应值有良好线性关系,相关系数r2>0.998。syn-DP和anti-DP的检出限分别为0.056 mg·L-1、0.043 mg·L-1,3个浓度添加水平的回收率在87.5%~102.4%范围内,变异系数在2.2%~6.5%范围内,满足胶黏剂中DP含量检测的分析需求。利用该方法测定市售的14款胶黏剂样品,其中在汽车电路板胶黏剂中检出DP。  相似文献   

11.
采用液液萃取,气相色谱-负离子化学电离质谱技术,建立了人体血清样品中新型含氯阻燃剂德克隆(DP)的分离分析方法.血清样品蛋白质变性后,采用液液萃取法提取脂肪,再采用浓H2SO4破坏法去除大部分脂肪,最后采用酸性硅胶柱进一步净化.净化后的样品经浓缩富集,采用气相色谱-负离子化学电离质谱仪测定样品中DP两种同分异构体的含量...  相似文献   

12.
以丙酮为萃取溶剂,建立了超声萃取/气相色谱-串联质谱同时测定纺织品中6种禁用有机磷阻燃剂的分析方法.6种禁用有机磷阻燃剂三-(1-氮杂环丙基)氧化膦( TEPA)、三-(2-氯乙基)磷酸酯(TCEP)、三-(2,3-二氯丙基)磷酸酯(TDCP)、二-(2,3-二溴丙基)磷酸酯(DDBPP)、三-(邻甲苯基)磷酸酯(TO...  相似文献   

13.
The identification and quantification of organic compounds in leaching basin soil is important for the evaluation of soil pollution. In this study, a non-target screening strategy and a quantitative analytical method were developed based on the accelerated solvent extraction method followed by comprehensive two-dimensional gas chromatography with time-of-flight mass spectrometry. First, a screening method for potential risk compounds in soil samples was established, and the major compounds were screened under the conditions such as matching similarity, signal-to-noise ratio, and relative area ratio. Second, a quantitative method was further developed by internal calibration curves for 50 main organic pollutants in the soil samples, including 27 polycyclic aromatic hydrocarbons and their derivatives (PAHs), 10 phthalic acid esters, eight phenolic compounds, and five benzene derivatives. The quantitative procedure exhibited good selectivity, accuracy, precision, low limits of detection (0.03–1.02?ng/g), and quantification (0.1–3.0?ng/g) for all target compounds. Finally, the proposed strategy was applied to the soil samples that were collected from a leaching basin and polluted by electroplating wastewater. Abundant PAHs and phenolic compounds were detected in the topsoil sample, which were mainly released from the electroplating wastewater. The application of this multi-dimensional strategy in leaching basin soil samples can also be used for the assessment of organic pollution in other complex soil samples.  相似文献   

14.
运用气相色谱-离子阱质谱(ion trap mass spectrometry,ITMS)建立了大气中8种多溴二苯醚的二级质谱(MS/MS)检测方法。优化后的MS/MS方法对7种三溴至七溴二苯醚(BDE28、-47、-99、-100、-153、-154、-183)和十溴二苯醚(BDE209)的仪器检出限分别为0.04~0.23 pg和9.38 pg;方法检出限为6.0~27.1 pg/m3和211.6 pg/m3;6点标准曲线相关系数(r)为0.9980~0.9999。方法对8种目标物的加标回收率为79.1%~101.0%,相对标准偏差(RSD)为4.3%~14.3%(n=6)。对6份南京实际大气样品的检测结果表明:离子阱质谱的选择反应监测(selected reaction monitoring,SRM)技术能有效的降低背景干扰。优化后的MS/MS方法对目标化合物有较高的灵敏度,可应用于大气中痕量多溴二苯醚的定量检测。  相似文献   

15.
采用QuEChERS方法对市售腊肠中的N-亚硝基二甲胺(NDMA)、N-亚硝基二乙胺(NDEA)、N-亚硝基甲乙胺(NMEA)、N-亚硝基二丙胺(NDPA)、N-亚硝基吡咯烷(NPYR)、N-亚硝基哌啶烷(NPIP)、N-亚硝基二丁胺(NDBA)、N-亚硝基吗啉(NMOR)、N-亚硝基二苯胺(NDPhA)9种对人体有致癌活性的挥发性亚硝胺进行分离净化,气相色谱-三重四极杆质谱联用法(GC-MS/MS)检测。最佳实验条件下,9种挥发性亚硝胺的线性范围为0.25~200μg/L,检出限为0.01~0.10μg/kg,加标回收率为90.7%~116.0%,相对标准偏差(RSD)为1.8%~14.0%。市售腊肠样品中NDMA,NMOR,NPYR,NDPA,NPIP,NDBA,NDPhA均有不同程度的检出,总挥发性亚硝胺的含量为1.85~13.44μg/kg。该方法灵敏度高、操作简单,适合批量样品的快速检测。  相似文献   

16.
任丽  王国俊 《色谱》1998,16(3):238-243
利用吸附剂GDX-301对黄河水中的有机污染物富集并以超临界CO2脱附后,通过气相色谱、色谱-红外-质谱联用技术对各目标分析物逐一定性,并比较了超临界CO2萃取和溶剂洗脱的结果。实验表明,在20MPa,60℃,40min条件下进行超临界CO2萃取时的萃取效率和溶剂萃取效率相当或略高。  相似文献   

17.
Polychlorinated biphenyls (PCBs) and organochlorine pesticides (OCs) are anthropogenic pollutants highly resistant to chemical degradation and readily absorbed by organic tissue. Their persistence in the environment and toxicological threat to mammals prompts swift, reliable methods of analysis. This study outlines a rapid, efficient and sensitive, validated methodology utilizing a simple liquid extraction technique, and subsequent analysis by gas chromatography coupled with tandem mass spectrometry (GC-MS/MS) for the determination of PCBs and OCs from dried blood spots. The PCBs and OCs were quantified in whole marine mammal blood spotted on Whatman Protein Saver cards (PSCs) by extracting the analytes into acetonitrile acidified with formic acid, followed by GC-MS/MS analysis. The samples were analyzed in positive electron impact (EI+) ionization mode with the electron energy set to 40?eV to preserve analyte integrity. Fortified blood with the analytes of interest was used for method validation and subsequent sample screening. The recoveries of targeted analytes ranged from 62.5% to 107.8%, with relative standard deviations ranging from 0.09% to 4.6% at a 100?ng·mL?1 concentration level. The method detection limits were from 40.4?ng·g?1 to 179.2?ng·g?1 for the PCBs and 37.6?ng·g?1 to 145.1?ng·g?1 for the OCs. The use of dried blood spots provided for numerous advantages compared to whole blood samples while demonstrating reduced matrix effects and enhanced sample lifespan while retaining analyte sensitivity.  相似文献   

18.
食品中胆固醇色谱/质谱/质谱的测定   总被引:3,自引:0,他引:3  
王志元 《分析化学》1998,26(1):48-50
确立了用色谱/质谱/质谱测定食品中胆固醇的一种新方法,试样经乙酸乙酯提取后,GC/MS/MS测定分析,以胆固醇分子离子为母离了,以其子离子为定量分析的碎片离子。线性好,回收率高,方法可靠。  相似文献   

19.
甘草化学成分的高效液相色谱-串联质谱分析   总被引:21,自引:0,他引:21  
采用高效液相色谱-质谱联用方法分析了甘草(Glycyrrhiza uralensis)中的化学成分。通过高效液相色谱可将三萜、黄酮及香豆素等50余种化学成分较好的分离。根据紫外光谱可大致判断其化合物类型,由电喷雾质谱得到各成分的分子量,再由串联质谱获得进一步的结构信息,进而推测出其中22个主要成分的可能结构。它们分别是:葡糖基甘草甙、异光果甘草甙、夏拂托甙、甘草素-4′-芹糖甙,甘草甙,6′-乙酰甘草甙,异佛来心甙,异甘草素葡萄糖芹菜甙,甘草糖甙A,甘草糖甙B,甘草素,3.0-[β-D-葡萄糖醛酸甲酯-(1→2)-β-D-葡萄糖醛酸]-24-羟基-甘草内酯,甘草皂甙E2,异甘草素,甘草醇,甘草酸,甘草香豆素,甘草双氢异黄酮,甘草异黄酮甲,乌拉尔甘草皂甙乙,新甘草酚和甘草皂甙B2。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号