Several procedures are available for simulating and optimising separations in ion chromatography (IC), based on the application of retention models to an extensive database of analyte retention times on a wide range of columns. These procedures are subject to errors arising from batch-to-batch variability in the synthesis of stationary phases, or when using a column having a different diameter to that used when the database was acquired originally. Approaches are described in which the retention database can be recalibrated to accommodate changes in the stationary phase (ion-exchange selectivity coefficient and ion-exchange capacity) or in the column diameter which lead to changes in phase ratio. The entire database can be recalibrated for all analytes on a particular column by performing three isocratic separations with two analyte ions. The retention data so obtained are then used to derive a "porting" equation which is employed to generate the required simulated separation. Accurate prediction of retention times is demonstrated for both anions and cations on 2mm and 0.4mm diameter columns under elution conditions which consist of up to five sequential isocratic or linear gradient elution steps. The proposed approach gives average errors in retention time prediction of less than 3% and the correlation coefficient was 0.9849 between predicted and observed retention times for 344 data points comprising 33 anionic or cationic analytes, 5 column internal diameters and 8 complex elution profiles.  相似文献   

2.
The unique ability of macrocyclic ligands, such as the crown ethers and cryptands, to selectively complex alkali metal cations can be used as the basis for chromatographic separations of anions. Specifically, macrocycles which are adsorbed onto a reversed-phase column, form positively charged anion-exchange sites when they combine with eluent cations. Previously we have demonstrated gradient anion separations based on changing the column capacity during the course of the separation by altering the eluent cation, temperature, or organic modifier content using cryptand-based columns. Herein we report that excellent separations can also be achieved using 18-crown-6 based columns. In this column, anion retention increases with increasing eluent strength and organic modifier content. This observation is in keeping with the relatively moderate affinity of crown ethers for alkali metals when compared to cryptands. The separation of anions achieved by optimizing mobile phase variables shows that isocratic separations of anions on the crown-based column are almost as good as separations achieved only under gradient conditions on cryptand-based columns. Cation gradients provide additional improvements on the separations using the crown-based column.  相似文献   

3.
Monolithic poly(butyl methacrylate-co-ethylene dimethacrylate) capillary columns have been prepared via either thermally or photochemically initiated polymerization of the corresponding monomers and the repeatability of their preparation has been explored. Three separate batches of 5 columns each were prepared using thermal and photochemical initiation for a total of 30 columns. All 30 capillary columns were tested in liquid chromatography-electrospray ionisation mass spectrometry mode for the separation of a model mixture of three proteins--ribonuclease A, cytochrome c and myoglobin. Excellent repeatability of retention times was observed for the proteins as evidenced by relative standard deviation (RSD) values of less than 1.5%. Somewhat broader variations with RSD values of up to 10% were observed for the pressure drop in the columns. The stability of retention times was also monitored using a single monolithic column and no significant shifts in either retention times or back pressure was observed in a series of almost 2200 consecutive protein separations.  相似文献   

4.
Summary During the past decade, HPLC has developed into a powerful new technique for the analysis of complex mixtures of biological macromolecules. Through the use of microparticulate supports of vastly improved mechanican strength, superior stationary phase chemistry, and advanced instrumentation, it is now possible to separate biological macromolecules more than 10 times faster and with greater resolution than in the classical SEC, IEC, HIC, bioaffinity, and hydroxyapetite chromatography columns. Additionally, the introduction of new separation modes such as RPC and metal chelate make it possible to carry out separations that were not possible with the classical gel-type media. It is anticipated that 1) expanded use of non-porous media, 2) development of new stationary phases for carbohydrates, 3) greater throughput and resolution in preparative separations, and 4) better understanding of retention mechanisms are a few of the areas of macromolecular separations in which advances can be expected in the next few years.  相似文献   

5.
An HETP equation for the capillary column is developed that takes into account the dependence of gaseous diffusion on pressure, the compressibility of the mobile phase, together with the unique relationship between mobile phase velocity, and the resistance to mass transfer in the stationary phase. The equation is used to develop a procedure for column optimization and expressions are derived that allow the optimum column radius and optimum column length to be calculated for a given fixed inlet pressure. It is shown that fast, simple separations are optimally achieved using relatively short small diameter columns. Conversely, optimum performance for the separation of complex mixtures requiring higher efficiencies requires the use of long columns with relatively large diameters.  相似文献   

6.
Summary Packed columns containing microparticles provide high column efficiency per unit time and strong retention characteristics compared with open tubular columns, and they are favored for fast separations. Nonporous particles eliminate the contribution of solute mass transfer resistance in the intraparticle void volume characteristic of porous particles, and they should be more suitable for fast separations. In this paper, the evaluation of nonporous silica particles of sizes ranging from 5 to 25 μm in packed capillary columns for fast supercritical fluid chromatography (SFC) using neat CO2 is reported. These particles were first deactivated using polymethyl-hydrosiloxanes and then encapsulated with a methylphenylpolysiloxane stationary phase. The retention factors, column efficiencies, column efficiencies per unit time, separation resolution, and separation resolution per unit time for fast SFC were determined for various length capillaries packed with various sizes of polymerencapsulated nonporous particles. It was found that 15 μm nonporous particles provided the highest column efficiency per unit time and resolution per unit time for fast packed capillary SFC. Under certain conditions, separations were completed in less than 1 min. Several thermally labile silylation reagent samples were separated in times less than 5 min. Presented at the 21st ISC held in Stuttgart, Germany, 15th–20th September, 1996  相似文献   

7.
Fast GC separations of a broad range of analytes are demonstrated using a capillary column coated with a novel immobilized ionic liquid (IIL) stationary phase. Both completely cross-linked and partially cross-linked columns were evaluated, yielding approximately 1600 and approximately 2000 theoretical plates per meter, respectively. Enhanced separation is demonstrated using a dual-column ensemble comprised of an IIL column, a commercially coated Rtx-1 column, and a pneumatic valve connecting the inlet to the junction point between the two columns. Enhanced separation of 20 components, with two sets of co-eluting peaks is shown in approximately 150 s, while sacrificing only a length of time equivalent to the sum of the stop flow pulses, or about 15.5 s. A novel application of a band trajectory model that shows band position as a function of analysis time as analytes move through the column ensemble is employed to determine pulse application times. The model predicts component retention times within a few seconds. Another method of selectivity enhancement of the IIL stationary phase-coated columns is demonstrated using a differential mobility spectrometer (DMS) that provides a second dimension separation based on ion mobility in a high-frequency electrical field. The DMS is able to separate all but one set of co-eluting components from the IIL column. The separation of 13 components found in the headspace above U.S. currency is demonstrated using the IIL column in a dual-column ensemble as well as with the DMS.  相似文献   

8.
The proteomic analysis of plasma and serum samples represents a formidable challenge due to the presence of a few highly abundant proteins such as albumin and immunoglobulins. Detection of low abundance protein biomarkers therefore requires either the specific depletion of high abundance proteins using immunoaffinity columns and/or optimized protein fractionation methods based on charge, size or hydrophobicity. Here we describe a two-dimensional (2D) liquid chromatography separation method for the fractionation of rat plasma. In the first dimension proteins were separated by chromatofocusing according to their isoelectric point (pI). In the second dimension, proteins were further fractionated by non-porous, reversed-phase chromatography according to their hydrophobicity. The data from both separations was displayed as a 2D protein expression map of pI versus retention time (relative hydrophobicity). Both separations were carried out on the ProteomeLab PF 2D system (Beckman Coulter), an instrument platform that provides a high degree of automation and real-time monitoring of the separation process. The reproducibility of the first-dimension separation was evaluated in terms of pH gradient formation. The second-dimension separation was evaluated in terms of peak retention times on the reversed-phase column. We found in four consecutive chromatofocusing separations that the pH gradient differed by less than 0.2 pH units at any time during the elution step. Second dimension retention times of peaks from identical pI fractions differed by less than 7 s in six consecutive separations. Each 2D separation generated a total of 540 fractions which were analyzed by matrix assisted laser desorption ionization time of flight mass spectrometry (MALDI-TOF MS). We detected approximately 275 peptides and proteins with molecular masses ranging from 3 to 225 kDa. Most fractions were found to contain multiple low and high molecular weight proteins. Differential display of 2D protein expression maps from retinol-sufficient and -deficient rat plasma samples identified a fraction with several proteins that appeared to be down-regulated in the vitamin A-deficient animal. Quantitative proteomic analysis of complex samples such as plasma is still a difficult task. We discuss the potential of this approach for biomarker discovery and address the experimental challenges that remain.  相似文献   

9.
Gas-phase chemical separations have been used for the study of short-lived fission products. Often the chemical separation is achieved in a few seconds. The articles reviews the techniques used in fast, gas-phase separations.  相似文献   

10.
An electrically heated and air cooled metal sheath surrounding the first 50 cm of the second column in a series-coupled, capillary-column ensemble of a non-polar and a polar column is used to obtain enhanced isothermal separation of component pairs that are separated by the first column in the ensemble but co-elute from the ensemble by virtue of the different selectivity of the two columns. As the first of the two components passes into the second column, a current pulsed through the metal sheath rapidly heats the first 50 cm of the second column thus accelerating the band for the first component. Ensemble retention-time shifts of several seconds are easily obtained. The device is then rapidly cooled to quiescent oven temperature by a flow of pressured air through the space between the metal sheath and the fused silica capillary column and an additional flow through a larger, co-axial plastic tube. Both heating and cooling require only a few seconds. If substantial cooling of the device occurs before the band for the second component enters the device, the band experiences less thermally-induced acceleration with the result that the separation of the two targeted components is enhanced in the ensemble chromatogram with no significant change in the pattern of peaks for the other mixture components. If the device is cooled to a temperature below oven temperature before the arrival of the band for the second component, this band will be slowed, and further enhancement of separation is achieved in the ensemble chromatogram. A band trajectory model, based on retention factor versus temperature data for the two components in the two columns, is used to predict peak separation and to aid in the selection of temperature-pulse initiation times.  相似文献   

11.
Effects of extra-column volume on apparent separation parameters were studied in ultra-high pressure liquid chromatography with columns and inlet connection tubings of various internal diameters (id) using 50-mm long columns packed with 1.8-μm particles under isocratic conditions. The results showed that apparent retention factors were on average 5, 11, 18, and 41% lower than those corrected with extra-column volumes for 4.6-, 3.0-, 2.1-, and 1.0-mm id columns, respectively, when the extra-column volume (11.3 μL) was kept constant. Also, apparent pressures were 31, 16, 12, and 10% higher than those corrected with pressures from extra-column volumes for 4.6-, 3.0-, 2.1-, and 1.0-mm id columns at the respective optimum flow rate for a typical ultra-high pressure liquid chromatography system. The loss in apparent efficiency increased dramatically from 4.6- to 3.0- to 2.1- to 1.0-mm id columns, less significantly as retention factors increased. The column efficiency was significantly improved as the inlet tubing id was decreased for a given column. The results suggest that maximum ratio of extra-column volume to column void volume should be approximately 1:10 for column porosity more than 0.6 and a retention factor more than 5, where 80% or higher of theoretically predicted efficiency could be achieved.  相似文献   

12.
The synergy of combining fast temperature programming capability and adsorption chromatography using fused silica based porous layer open tubular columns to achieve high throughput chromatography for the separation of volatile compounds is presented. A gas chromatograph with built‐in fast temperature programming capability and having a fast cool down rate was used as a platform. When these performance features were combined with the high degree of selectivity and strong retention characteristic of porous layer open tubular column technology, volatile compounds such as light hydrocarbons of up to C7, primary alcohols, and mercaptans can be well separated and analyzed in a matter of minutes. This analytical approach substantially improves sample throughput by at least a factor of ten times when compared to published methodologies. In addition, the use of porous layer open tubular columns advantageously eliminates the need for costly and time‐consuming cryogenic gas chromatography required for the separation of highly volatile compounds by partition chromatography with wall coated open tubular column technology. Relative standard deviations of retention time for model compounds such as alkanes from methane to hexane were found to be less than 0.3% (n = 10) and less than 0.5% for area counts for the compounds tested at two levels of concentration by manual injection, namely, 10 and 1000 ppm v/v (n = 10). Difficult separations were accomplished in one single analysis in less than 2 min such as the characterization of 17 components in cracked gas containing alkanes, alkenes, dienes, branched hydrocarbons, and cyclic hydrocarbons.  相似文献   

13.
Chromatographic enantioseparations on the order of a few seconds can be achieved by supercritical fluid chromatography using short columns packed with chiral stationary phases. The evolution of ‘world record’ speeds for the chromatographic separation of enantiomers has steadily dropped from an industry standard of 20–40 min just two decades ago, to a current ability to perform many enantioseparations in well under a minute. Improvements in instrument and column technologies enabled this revolution, but the ability to predict optimal separation time from an initial method development screening assay using the tmin cc predictor greatly simplifies the development and optimization of high‐speed chiral chromatographic separations. In this study, we illustrate how the use of this simple tool in combination with the workhorse technique of supercritical fluid chromatography on customized short chiral columns (1–2 cm length) allows us to achieve ultrafast enantioseparations of pharmaceutically relevant compounds on the 5–20 s scale, bringing the technique of high‐throughput enantiopurity analysis out of the specialist realm and into the laboratories of most researchers.  相似文献   

14.
The preparation of monolithic poly(butyl methacrylate-co-ethylene dimethacrylate) capillary columns using photoinitiated in situ polymerization within 200 microm i.d. capillaries and their application for microHPLC separations of proteins have been studied. The low resistance to flow characteristic of monolithic columns, enabled the use of very high flow rates of up to 100 microL/min representing a flow velocity of 87 mm/s. Very good separations of a model protein mixture consisting of ribonuclease A, cytochrome c, myoglobin, and ovalbumin was achieved in less than 40 s using a very simple single step gradient of the mobile phase. Interestingly, no effect of the pore size on the separations of proteins was observed for these monolithic columns within the size range of 0.66-2.2 microm. The monolithic microHPLC columns are found very robust and no changes in the long term separation performance and back pressure were observed.  相似文献   

15.
Packed capillary column solvating gas chromatography (SGC) and open tubular column gas chromatography (GC) were compared with respect to their potentials for fast separations. A recently introduced "universal" peak capacity equation was used to compare the performance of these two methods. The effects of various factors on peak capacity were investigated. Results demonstrate that retention factor and column efficiency are the main factors affecting peak capacity for fast separations. Packed columns produce both high retention factors and high selectivities. While high efficiencies and high peak capacities can be demonstrated by both techniques, open tubular column GC can surpass packed capillary column SGC in both measurements, except for the case of the analysis of simple mixtures in short analysis times, where retention factor and selectivity become important. Practical aspects such as pressure drop and sample capacity are compared for SGC and open tubular column GC. It was found that packed column SGC demonstrates higher sample capacities, but requires much higher column inlet pressures than open tubular column GC. A variety of mobile phases can be used for packed column SGC, which can provide high solvating power for large and polar compounds.  相似文献   

16.
A porous polymer is deposited on the inner wall of fused silica capillary columns. The retention characteristics of this porous polymer were evaluated and found to be comparable with Porapak Q. The porous polymer has a high retention volume which enables the separation of permanent gases at ambient temperatures or higher. The hydrophobic character of the porous polymer allows the injection of water containing samples without changing retention due to adsorption of water. The inertness of the porous polymer allows the elution of a range of apolar and polar compounds. The maximum temperature of the porous polymer was estimated to be 250°C. With this new type of capillary column, high resolution separations are obtained in combination with short analysis times.  相似文献   

17.
High-efficiency peptide analysis using multimode pressure-assisted capillary electrochromatography/capillary electrophoresis (pCEC/pCE) monolithic polymeric columns and the separation of model peptide mixtures and protein digests by isocratic and gradient elution under an applied electric field with UV and electrospray ionization-mass spectrometry (ESI-MS) detection is demonstrated. Capillary multipurpose columns were prepared in silanized fused-silica capillaries of 50, 75, and 100 microm inner diameters by thermally induced in situ copolymerization of methacrylic monomers in the presence of n-propanol and formamide as porogens and azobisisobutyronitrile as initiator. N-Ethylbutylamine was used to modify the chromatographic surface of the monolith from neutral to cationic. Monolithic columns were termed as multipurpose or multimode columns because they showed mixed modes of separation mechanisms under different conditions. Anion-exchange separation ability in the liquid chromatography (LC) mode can be determined by the cationic chromatographic surface of the monolith. At acidic pH and high voltage across the column, the monolithic stationary phase provided conditions for predominantly capillary electrophoretic migration of peptides. At basic pH and electric field across the column, enhanced chromatographic retention of peptides on monolithic capillary column made CEC mechanisms of migration responsible for separation. The role of pressure, ionic strength, pH, and organic content of the mobile phase on chromatographic performance was investigated. High efficiencies (exceeding 300 000 plates/m) of the monolithic columns for peptide separations are shown using volatile and nonvolatile, acidic and basic buffers. Good reproducibility and robustness of isocratic and gradient elution pressure-assisted CEC/CE separations were achieved for both UV and ESI-MS detection. Manipulation of the electric field and gradient conditions allowed high-throughput analysis of complex peptide mixtures. A simple design of sheathless electrospray emitter provided effective and robust low dead volume interfacing of monolithic multimode columns with ESI-MS. Gradient elution pressure-assisted mixed-mode separation CE/CEC-ESI-MS mass fingerprinting and data-dependent pCE/pCEC-ESI-MS/MS analysis of a bovine serum albumin (BSA) tryptic digest in less than 5 min yielding high sequence coverage (73%) demonstrated the potential of the method.  相似文献   

18.
A rapid procedure for the analysis of glycopeptides has been developed using gel permeation high-performance liquid chromatography (HPLC). Glycopeptides derived by exhaustive pronase digestion of glycoproteins from radiolabeled human tumor and normal cell lines were chromatographed on DuPont GF-250 and GF-450 gel permeation columns in buffers containing non-ionic detergents. Effective separations of glycopeptides ranging in molecular mass from less than 600 daltons to more than 20,000 daltons, equivalent to the separation range of Sephadex G50 chromatography, were achieved in 7 min. The separations were dependent upon the use of an isocratic mobile phase, that contained a low-ionic-strength Tris buffer and Nonidet P-40 or Triton X-100. The mobilities of protein standards indicated the occurrence of a biphasic elution system, which favored the separation of species with molecular masses below 20,000 daltons. Glycopeptides isolated by this method could be applied directly to lectin or ion-exchange columns or could be digested with neuraminidase, endo H or other enzymes without further treatment. Removal of sialic acid from the glycopeptides caused a dramatic increase in retention time. Using this method, glycopeptides could be isolated rapidly and in high yield. The ease, speed and reproducibility of the separations and compatibility of the solvent systems with affinity or ion-exchange chromatography techniques make this gel permeation HPLC method an ideal initial step in the purification of glycopeptides.  相似文献   

19.
The ion-exchange separation of organic anions of varying molecular mass has been demonstrated using ion chromatography with isocratic, gradient and multi-step eluent profiles on commercially available columns with UV detection. A retention model derived previously for inorganic ions and based solely on electrostatic interactions between the analytes and the stationary phase was applied. This model was found to accurately describe the observed elution of all the anions under isocratic, gradient and multi-step eluent conditions. Hydrophobic interactions, although likely to be present to varying degrees, did not limit the applicability of the ion-exchange retention model. Various instrumental configurations were investigated to overcome problems associated with the use of organic modifiers in the eluent which caused compatibility issues with the electrolytically derived, and subsequently suppressed, eluent. The preferred configuration allowed the organic modifier stream to bypass the eluent generator, followed by subsequent mixing before entering the injection valve and column. Accurate elution prediction was achieved even when using 5-step eluent profiles with errors in retention time generally being less than 1% relative standard deviation (RSD) and all being less than 5% RSD. Peak widths for linear gradient separations were also modelled and showed good agreement with experimentally determined values.  相似文献   

20.
Novel and efficient separations of pharmaceutical substances were achieved using oil-in-water microemulsion eluent and a conventional C18 packing with a flow rate of 1 mL/min−1. Attempts to decrease analysis time was limited due to the high viscosity of the microemulsion which generated relatively high back-pressures. Monolithic columns gave 3-fold lower back-pressures and allowed flow rates of 4 mL/min−1. with the same microemulsion mobile phase which permitted rapid separations to be achieved. Separation of a test-mix of paraben preservatives was achieved in both isocratic and gradient mode in less than 1 min. The monolith-microemulsion combination was applied to rapidly quantitatively analyse two formulated products with excellent linearity, accuracy and repeatability. Quantitative analysis times were under 90 seconds. Successful quantitation of both nicotine lozenges and naprosyn tablets was performed using this approach.  相似文献   