首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Summary: The newly developed interactive separation of polyolefins by high temperature liquid chromatography (HTLC) provides new information about the chemical composition distribution of polyolefin elastomers. The technique has the advantage of being quantitative in its separation, and has high resolution for the separation of polyolefins by their chemical composition without influence by cocrystallization. Chemical composition distributions can be determined for individual polymers and blends which contain the full range of comonomer typically present in polyethylene and poylypropylene homopolymers, semi-crystalline copolymers, and amorphous copolymers. HTLC analysis in combination with the other fractionation techniques, such as DSC, TREF, NMR, and xylene fractionation, can be used to estimate the amount of olefin block copolymer present in a block composite produced by chain shuttling catalysis.  相似文献   

2.
Summary: The synthesis and characterization of polyolefins continues to be one of the most important areas for academic and industrial polymer research. One consequence of the development of new “tailor-made” polyolefins is the need for new and improved analytical techniques for the analysis of polyolefins with respect to molar mass and chemical composition distribution. The present article briefly reviews different new and relevant chromatographic techniques for polyolefin analysis. For the fast analysis of the chemical composition distribution of polyolefins a new high-temperature gradient high-performance liquid chromatography (HPLC) system has been introduced. The efficiency of this system for the separation of various olefin copolymers is demonstrated. The correlation between elution volume and chemical composition can be accessed by on-line coupling of high temperature HPLC with FTIR spectroscopy. For the elucidation of the chemical composition as a function of molar mass high-temperature size exclusion chromatography and 1H-NMR spectroscopy can be coupled. It is shown that the on-line NMR analysis of chromatographic fractions yields information on microstructure and chemical composition in addition to molar mass distribution.  相似文献   

3.
《Analytical letters》2012,45(9):1380-1395
A novel resonance Rayleigh scattering (RRS) detection approach combined with high–performance liquid chromatography (HPLC) was developed for the determination of reserpine, deserpidine, and ajmalicine. The resonance Rayleigh scattering signal increased when the analytes were bound to diiodofluorescein in Britton–Robinson buffer (pH 4.2). Separation was performed using a C18 column with a mobile phase consisting of acetonitrile–5 millimolar ammonium acetate buffer at pH 4.2 (44:56, volume by volume). Resonance Rayleigh scattering was measured at excitation and emission wavelengths of 320 nanometers. The experimental parameters affecting the separation and the scattering intensity were carefully optimized. Possible mechanisms for the resonance Rayleigh scattering enhancement of the indole alkaloid–diiodofluorescein system were explored by scanning electron microscopy, nuclear magnetic resonance, and ultraviolet-visible absorption spectroscopy. The method was employed for the determination of the analytes in human urine and pharmaceutical tablets.  相似文献   

4.
Comprehensive two-dimensional liquid chromatography (LC × LC) is rapidly evolving as the preferred method for the analysis of complex biological samples owing to its much greater resolving power compared to conventional one-dimensional (1D-LC). While its enhanced resolving power makes this method appealing, it has been shown that the precision of quantitation in LC × LC is generally not as good as that obtained with 1D-LC. The poorer quantitative performance of LC × LC is due to several factors including but not limited to the undersampling of the first dimension and the dilution of analytes during transit from the first dimension (1D) column to the second dimension (2D) column, and the larger relative background signals. A new strategy, 2D assisted liquid chromatography (2DALC), is presented here. 2DALC makes use of a diode array detector placed at the end of each column, producing both multivariate 1D and two-dimensional (2D) chromatograms. The increased resolution of the analytes provided by the addition of a second dimension of separation enables the determination of analyte absorbance spectra from the 2D detector signal that are relatively pure and can be used to initiate the treatment of data from the first dimension detector using multivariate curve resolution–alternating least squares (MCR–ALS). In this way, the approach leverages the strengths of both separation methods in a single analysis: the 2D detector data is used to provide relatively pure analyte spectra to the MCR–ALS algorithm, and the final quantitative results are obtained from the resolved 1D chromatograms, which has a much higher sampling rate and lower background signal than obtained in conventional single detector LC × LC, to obtain accurate and precise quantitative results. It is shown that 2DALC is superior to both single detector selective or comprehensive LC × LC and 1D-LC for quantitation of compounds that appear as severely overlapped peaks in the 1D chromatogram – this is especially true in the case of untargeted analyses. We also anticipate that 2DALC will provide superior quantitation in targeted analyses in which unknown interfering compounds overlap with the targeted compound(s). When peaks are significantly overlapped in the first dimension, 2DALC can decrease the error of quantitation (i.e., improve the accuracy by up to 14-fold compared to 1D-LC and up to 3.8-fold compared to LC × LC with a single multivariate detector). The degree of improvement in performance varies depending upon the degree of peak overlap in each dimension and the selectivities of the spectra with respect to one another and the background, as well as the extent of analyte dilution prior to the 2D column.  相似文献   

5.
In the present study, an easy and efficient method based on the serial coupling of analytical reversed‐phase and zwitterionic hydrophilic interaction liquid chromatography was developed for the simultaneous separation of polar and nonpolar phenols occurring in wine. The zwitterionic hydrophilic column was connected in series to the reversed‐phase one via a T‐piece, with which the ACN content in eluent of the second dimension was increased, in order to cope the solvent strength incompatibility between the two columns. The final mobile phase at low‐flow rate (≤0.5 mL/min), high‐ACN content (90%), and low‐salt concentration was directed to an ESI‐TOF‐MS , for high accurate mass detections. The developed method was applied for the identification of target phenols in several wines. Retention time and peak width intra‐ and interday repeatability studies proved the reliability of the method for the simultaneous analysis of all the polar and nonpolar analytes in wine. The serial reversed‐phase/zwitterionic hydrophilic interaction liquid chromatography coupling offered the possibility to enlarge the number of identified compounds and it represents a valid approach for nontarget analysis of complex samples by a single injection.  相似文献   

6.
The chemometrics approach was applied for the separation optimization of flavonoid markers (quercetin, hesperetin and chrysin) in honey using micellar liquid chromatography (MLC). The investigated method combines SPE of flavonoids from honey using C18 cartridge and their separation and quantification by micellar liquid chromatography. A two level full factorial design was carried out to evaluate the effect of four experimental factors including concentration of SDS, alkyl chain length of the alcohol used as the organic modifier (N), volume percentage of the organic modifier (Vm) and volume percentage of acetic acid (AcOH) in mobile phase on analytes retention times. Experiments for analytes retention times modeling and optimization of separation were performed according to central composite design. Multiple linear regression method was used for the construction of the best model based on experimental retention times. Pareto optimal method was used to find suitable compatibility between resolution and analysis time of analytes in honey. The optimum mobile phase composition for separation and determination of analytes in honey were [SDS]=0.124 mol/L; 7.8% v/v ethanol and 5.0% v/v AcOH. Limits of detection and linear range of flavonoid markers were 0.0079–0.0126, 0.05–50.0 mg/L, respectively.  相似文献   

7.
Jia L  Tanaka N  Terabe S 《Electrophoresis》2005,26(18):3468-3478
A two-dimensional (2-D) separation system of coupling chromatography to electrophoresis was developed for profiling Escherichia coli metabolites. Capillary liquid chromatography (LC) with a monolithic silica-octadecyl silica column (500 x 0.2 mm ID) was used as the first dimension, from which the effluent fractions were further analyzed by capillary electrophoresis (CE) acting as the second dimension. Field-enhanced stacking was selectively employed as a concentration strategy to interface the two dimensions, which proved to be beneficial for the detection of metabolites. An artificial sample containing 118 standards, some of which lack chromophores or have weak UV absorbance, was used to optimize the 2-D separation system. Under the optimum conditions, 63 components in the artificial sample having absorbance at 254 nm could be well resolved and detected. The utility of the system was demonstrated by comprehensive analysis of E. coli metabolites. Comparing with the previous 2-D separation system we published in Anal. Chem. 2004, 76, 1419-1428, using a longer monolithic column in the first dimension improved the separation efficiency and offered the possibility of increasing the injection volume without compromising the separation efficiency. In the second dimension, field-enhanced stacking was used to improve the concentration sensitivity of the metabolites, and more metabolites in E. coli cell extract were detected and identified using the developed 2-D separation system. In addition, preliminary investigation for future CE-mass spectrometry coupling was also made in the study by using volatile buffers in the capillary LC and CE techniques.  相似文献   

8.
Temperature rising elution fractionation hyphenated to size exclusion chromatography (TREF × SEC) is a routine technique to determine the chemical heterogeneity of semicrystalline olefin copolymers. A serious limitation is its applicability to non crystallizing samples. Comprehensive high temperature two-dimensional liquid chromatography (HT 2D-LC) gives an alternative to characterize the chemical heterogeneity of copolymers irrespective of their crystallizability. We have hyphenated interactive HPLC, which separates polyolefins according to their chemical composition, with high-temperature size exclusion chromatography (SEC), which distinguishes polyolefins with regard to their molar mass at 160 °C. The first separation step was based on a selective adsorption of macromolecules on a Hypercarb® column packed with porous graphite particles and subsequent desorption by a gradient 1-decanol → 1,2,4-trichlorobenzene at 160 °C. The SEC column was calibrated with polypropylene (PP) and polyethylene (PE) standards and it turned out that the injection solvent from the first dimension influenced the elution of PP in the SEC column, while the retention of PE was virtually constant. HT 2D-LC was then used to separate a broad variety of polyolefin blends containing PE, PP with different microstructure, ethylene–propylene (EP) and ethylene–propylene–diene (EP(D)M) rubber and ethylene/1-hexene copolymers. For the first time it has been shown that the elution of iPP in the gradient HPLC is molar mass dependent. The results from the HT 2D-LC separation were compared to those from TREF × SEC-experiments. The particular advantage of HT 2D-LC over TREF × SEC is the fact that HT 2D-LC is also applicable to non crystallizing polyolefin samples. The new technique therefore resolves the problem to analyze the chemical heterogeneity of non crystallizing olefin copolymers like EP and EP(D)M copolymers.  相似文献   

9.
李笃信  魏远隆  宋伦  李彤  杜一平  张维冰 《化学学报》2009,67(21):2481-2485
在二维液相色谱中, 第二维的分离速度是制约其发展的重要因素. 升高色谱柱温度可以有效降低流动相粘度, 加快溶质在两相间的传质速率, 有效加快分析速度. 以离子交换色谱法(WAX)为第一维分离模式和反相色谱法(RP)为第二维分离模式, 十通阀和两个捕集柱为接口, 通过将第二维色谱柱温度升高到80 ℃和提高流量到3 mL/min, 构建了高温WAX/RP二维液相色谱系统. 以4种标准蛋白的酶解物为样品评价系统的分离性能, 第一维共有33个馏分被捕集并导入到第二维分析, 高温二维液相色谱系统识别出187个色谱峰.  相似文献   

10.
11.
探讨了以离子液体作为液相色谱流动相添加剂,对植物激素赤霉素GA3、生长素IAA和脱落酸ABA的分离的影响,以及离子液体的烷烃链长度,阴离子及离子液体的浓度对分离的影响。结果表明:咪唑阳离子和植物激素通过静电作用而保留;植物激素本身的pKa值影响其保留因子,pKa值增大,离子液体浓度对植物激素保留因子影响增大;另外随[BMIM]对应的阴离子电负性的减小,植物激素的保留因子明显地增大;同时植物激素的空间位阻也影响其分离。  相似文献   

12.
A vacuum assisted dynamic solvent evaporation interface for coupling of two-dimensional normal phase/reverse phase liquid chromatography was developed and evaluated. A normal-phase liquid chromatographic (NPLC) column of a 250 mm × 4.6 mm I.D. 5 μm CN phase was used as the first dimension, and a reversed-phase liquid chromatographic (RPLC) column of 250 mm × 4.6 mm I.D. 5 μm C18 phase was used as the second dimension. The eluent from the first dimension flowed into a fraction loop, and the solvent in the eluent was dynamically evaporated and removed by vacuum as it was entering the fraction loop of the interface. The non-evaporable analytes was retained and enriched in about 5–25 μL solution within the loop. Up to 1 mL/min of mobile phase from the first dimension can be evaporated and removed dynamically by the interface. The mobile phase from the second dimension then entered the loop, and dissolved the concentrated analytes retained inside the loop, and carried them onto the second dimension column for further separation. The operation conditions of the two dimensions were independent from each other, and both dimensions were operated at their optimal chromatographic conditions. We evaluated the interface by controlling the loop temperature in a water bath at normal temperature, and investigated the sample losses by using standard samples with different boiling points. It was found that the sample loss due to evaporation in the interface was negligible for non-volatile samples or for components with boiling point above 340 °C. The interface realizes fast solvent removal of mL volume of fraction and concentration of the fraction into tenth of μL volume, and injection of the concentrated fraction on the secondary column. The chromatographic performance of the two-dimensional LC system was enhanced without compromise of separation efficiency and selectivity on each dimension.  相似文献   

13.
Ginsenosides have been widely conceded as having various biological activities and are considered to be the active ingredient of ginseng. Nowadays, preparative high‐performance liquid chromatography is considered to be a highly efficient method for ginseng saponins purification and preparation. However, in the process of practical application, due to the complex and varied composition of natural products and relatively simple pretreatment process, it is likely to block the chromatographic column and affect the separation efficiency and its service life. In this work, an orthogonal strategy was developed; in the first‐dimension separation, reverse‐phase macroporous resin was applied to remove impurities in ginseng crude extracts and classified ginseng extracts into protopanaxatriol and protopanaxadiol fractions. In the second‐dimension separation, the obtained fractions were further separated by a preparative hydrophilic column, and finally yielded 11 pure compounds. Eight of them identified as ginsenoside Rh1, Rg2, Rd, Rc, Rb2, Rb1, Rg1, and Re by standards comparison and electrospray ionization mass spectrometry. The purity of these ginsenosides was assessed by high‐performance liquid chromatography with UV detection.  相似文献   

14.
反相高效液相色谱法分离测定烟草中的多酚类化合物   总被引:2,自引:0,他引:2  
李福娟  蔡文生  邵学广 《色谱》2007,25(4):565-568
对植物中9种多酚类化合物的色谱分离条件进行了优化,分别探讨了流动相组成、流动相中醋酸浓度、醋酸溶液与甲醇的比例对保留时间的影响,确定了梯度分离条件,并对9种天然多酚类化合物进行了定量分析。该方法的检测限为13.26~59.29 mg/kg (S/N=3)。在3.0~100.0 mg/L 范围内呈良好的线性关系,相关系数r2为 0.9979~0.9999。9种待测化合物的加标回收率为96.8%~108%,相对标准偏差(RSD)小于3.8% (n=3)。用80%甲醇超声提取烟草样品,并通过优化的色谱条件对其进行分析,测定了实际烟草样品中芸香苷和绿原酸的含量。结果表明,该方法具有一定的实用价值。  相似文献   

15.
An online high‐pH reversed‐phase liquid chromatography× low‐pH reversed‐phase liquid chromatography tandem electrospray ionization mass spectrometry combined with pulse elution gradient in the first dimension was constructed to separate and identify alkaloids from Macleaya cordata (willd.) R. Br. The modulation was performed by using a dual second dimensional columns interface combined with a make‐up dilution pump, which is responsible for dilution and neutralization of the first dimensional effluent, and the dual second dimensional columns integrated the trapping and the separation function to reduce the second dimension system dead volume. Taking advantage of the dissociable characteristics of alkaloids, mobile phases with different pH values were applied in the first dimension (pH 9.0) and the second dimension (pH 2.6) to improve the orthogonality of two‐dimension separation. Besides, the pulse elution gradient in first dimension and second dimensional gradient were carefully optimized and much better separation was achieved compared to the separation with the traditional two‐dimensional liquid chromatography approach. Finally, mass measurement was performed for alkaloids in M. cordata (willd.) R. Br. by coupling proposed two‐dimensional liquid chromatography system with triple quadrupole mass spectrometry, and 39 alkaloids were successfully identified by comparing the obtained result with the former reported results.  相似文献   

16.
This paper explores the analytical figures of merit of two‐dimensional high‐performance liquid chromatography for the separation of antioxidant standards. The cumulative two‐dimensional high‐performance liquid chromatography peak area was calculated for 11 antioxidants by two different methods—the areas reported by the control software and by fitting the data with a Gaussian model; these methods were evaluated for precision and sensitivity. Both methods demonstrated excellent precision in regards to retention time in the second dimension (%RSD below 1.16%) and cumulative second dimension peak area (%RSD below 3.73% from the instrument software and 5.87% for the Gaussian method). Combining areas reported by the high‐performance liquid chromatographic control software displayed superior limits of detection, in the order of 1 × 10?6 M, almost an order of magnitude lower than the Gaussian method for some analytes. The introduction of the countergradient eliminated the strong solvent mismatch between dimensions, leading to a much improved peak shape and better detection limits for quantification.  相似文献   

17.
An orthogonal (71.9%) off‐line preparative two‐dimensional normal‐phase liquid chromatography/reversed‐phase liquid chromatography method coupled with effective sample pretreatment was developed for separation and purification of flavonoids from licorice. Most of the nonflavonoids were firstly removed using a self‐made Click TE‐Cys (60 μm) solid‐phase extraction. In the first dimension, an industrial grade preparative chromatography was employed to purify the crude flavonoids. Click TE‐Cys (10 μm) was selected as the stationary phase that provided an excellent separation with high reproducibility. Ethyl acetate/ethanol was selected as the mobile phase owing to their excellent solubility for flavonoids. Flavonoids co‐eluted in the first dimension were selected for further purification using reversed‐phase liquid chromatography. Multiple compounds could be isolated from one normal‐phase fraction and some compounds with bad resolution in one‐dimensional liquid chromatography could be prepared in this two‐dimensional system owing to the orthogonal separation. Moreover, this two‐dimensional liquid chromatography method was beneficial for the preparation of relatively trace flavonoid compounds, which were enriched in the first dimension and further purified in the second dimension. Totally, 24 flavonoid compounds with high purity were obtained. The results demonstrated that the off‐line two‐dimensional liquid chromatography method was effective for the preparative separation and purification of flavonoids from licorice.  相似文献   

18.
Solvent compatibility is a limiting factor for the success of two-dimensional liquid chromatography (2-D LC). In the second dimension, solvent effects can result in overpressures as well as in peak broadening or even distortion. A peak shape study was performed on a one-dimensional high-performance liquid chromatography (HPLC) system to simulate the impact of peak distorting solvent effects on a reversed-phase second dimension separation operated at high temperatures. This study includes changes in injection volume, solute concentration, column inner diameter, eluent composition and oven temperature. Special attention was given to the influence of high temperatures on the solvent effects. High-temperature HPLC (HT-HPLC) is known to enhance second dimension separations in terms of speed, selectivity and solvent compatibility. The ability to minimise the viscosity contrast between the mobile phases of both dimensions makes HT-HPLC a promising tool to avoid viscosity mismatch effects like (pre-)viscous fingering. In case of our study, viscosity mismatch effects could not be observed. However, our results clearly show that the enhancement in solvent compatibility provided by the application of high temperatures does not include the elimination of solvent strength effects. The additional peak broadening and distortion caused by this effect is a potential error source for data processing in 2-D LC.  相似文献   

19.
Effective separation of mixtures of enantiomers is of continuing interest in analytical and preparative chromatography, with new materials frequently designed and tested. We report two new enantiomerically pure 2D→3D interpenetrated materials used as stationary liquid chromatographic (LC) phases that are shown to resolve selected racemic mixtures with enantiomeric and chemical selectivity. Dicarboxylate ligands derived from amino acids on naphthalene and perylene cores form 2D frameworks that interpenetrate to give 3D structures. Selectivity is initially tested by uptake from solution; subsequent LC methods show that the materials exhibit resolution of racemic analytes in ‘micro‐columns’ and that the two closely related materials show markedly different selectivity for different analytes with much greater activity than the ligands alone. Comparison with a close‐packed analogue suggests that the separation activity is largely due to surface effects.  相似文献   

20.
The responses of four different types of aerosol detectors have been evaluated and compared to establish their potential use as a universal detector in conjunction with ultra high pressure liquid chromatography (UHPLC). Two charged-aerosol detectors, namely Corona CAD and Corona Ultra, and also two different types of light-scattering detectors (an evaporative light scattering detector, and a nano-quantity analyte detector [NQAD]) were evaluated. The responses of these detectors were systematically investigated under changing experimental and instrumental parameters, such as the mobile phase flow-rate, analyte concentration, mobile phase composition, nebulizer temperature, evaporator temperature, evaporator gas flow-rate and instrumental signal filtering after detection. It was found that these parameters exerted non-linear effects on the responses of the aerosol detectors and must therefore be considered when designing analytical separation conditions, particularly when gradient elution is performed. Identical reversed-phase gradient separations were compared on all four aerosol detectors and further compared with UV detection at 200 nm. The aerosol detectors were able to detect all 11 analytes in a test set comprising species having a variety of physicochemical properties, whilst UV detection was applicable only to those analytes containing chromophores. The reproducibility of the detector response for 11 analytes over 10 consecutive separations was found to be approximately 5% for the charged-aerosol detectors and approximately 11% for the light-scattering detectors. The tested analytes included semi-volatile species which exhibited a more variable response on the aerosol detectors. Peak efficiencies were generally better on the aerosol detectors in comparison to UV detection and particularly so for the light-scattering detectors which exhibited efficiencies of around 110,000 plates per metre. Limits of detection were calculated using different mobile phase compositions and the NQAD detector was found to be the most sensitive (LOD of 10 ng/mL), followed by the Corona CAD (76 ng/mL), then UV detection at 200 nm (178 ng/mL) using an injection volume of 25 μL.  相似文献   