首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 75 毫秒
1.
The electrospray ionization (ESI) voltage is shown to interfere with liquid chromatographic separations performed with packed porous graphitic carbon (PGC) capillary columns. This interference is ascribed to the presence of an electric field over the conductive column in the absence of an earth point between the column and the ESI emitter. The current evolved alters the chromatographic behavior of the catecholamine metabolite 3-O-methyl-DOPA significantly, as both peak splitting and a dramatic decrease in the retention time were observed. Furthermore, the response from the mass spectrometer was decreased by 33% at the same time. A related compound, tyrosine, exhibited decreased retention times but no peak splitting, whereas no shifts in the retention times (or peak splitting) were seen for the less retained dopamine and noradrenaline. When the current through the PGC column was eliminated by the use of an earth point between the column and the ESI emitter, the chromatographic behavior of the column was found to return slowly to normal after hours of equilibration with 60 : 40 (v/v) methanol-ammonium formate buffer of pH 2.9. The behavior of the PGC column with and without the earth point was found to be highly reproducible during a period of 1 month. We propose that the effect of the ESI voltage on the chromatographic behavior of the PGC column is due to associated redox reactions affecting both the PGC particles and the analytes. It is concluded that (for analytical reasons), care should be taken to ensure that no current is flowing through the chromatographic system when interfacing PGC columns, and conducting parts in general, to ESI mass spectrometry.  相似文献   

2.
A compartment modeling approach based on computational fluid dynamics (CFD) simulations is applied to a simplified static mixer geometry. Compartments are derived from velocity fields obtained from cold CFD simulations. This methodology is based on the definition of periodic flow zones (PFZ) derived from the recurrent flow profile within the static mixer. In general, PFZ can be characterized by two different compartments: flow zones with hydrodynamic behavior of a tubular reactor and dead zones exhibiting a more continuous stirred tank reactor‐like characteristic. In CFD studies the influence of changing fluid properties, for example viscosity, on flow profile due to polymerization progress is considered. In the deterministic compartment model, the continuous flow profile within the static mixer is transformed to basic reactor models interconnected via an exchange stream. To reduce model complexity and the number of model parameters, constant volumes of compartments are assumed. Changes in hydrodynamics are considered by a variable exchange flow rate as a function of Re manipulating residence time in compartments. Simulation studies show the influence of decreasing exchange flow rates with polymerization progress, as Re decreases, resulting in a greater increase of viscosity in dead zones. The reactor performance is qualitatively represented by the simulation results.  相似文献   

3.
Four different sheathless electrospray ionization (ESI) configurations were investigated for a nano liquid chromatography (LC) system. The studied configurations were: a column with an integrated emitter, with the ESI potential applied before or after the column, and a column with separate emitter, with the ESI voltage applied at a union before the emitter or at the emitter tip. The results indicates that the efficiency of the LC system is rather independent of the configuration when using 95 microm i.d. columns, acetic mobile phase and standard peptides as a sample. Introduction of post column dead volume seems not to be a critical issue at least with flow rates down to 600 nl/min.  相似文献   

4.
Arrays of chemically etched emitters with individualized sheath gas capillaries were developed to enhance electrospray ionization (ESI) efficiency at subambient pressures. By incorporating the new emitter array in a subambient pressure ionization with nanoelectrospray (SPIN) source, both ionization efficiency and ion transmission efficiency were significantly increased, providing enhanced sensitivity in mass spectrometric analyses. The SPIN source eliminates the major ion losses of conventional ESI-mass spectrometry (MS) interfaces by placing the emitter in the first reduced pressure region of the instrument. The new ESI emitter array design developed in this study allows individualized sheath gas around each emitter in the array making it possible to generate an array of uniform and stable electrosprays in the subambient pressure (10 to 30 Torr) environment for the first time. The utility of the new emitter arrays was demonstrated by coupling the emitter array/SPIN source with a time of flight (TOF) mass spectrometer. The instrument sensitivity was compared under different ESI source and interface configurations including a standard atmospheric pressure single ESI emitter/heated capillary, single emitter/SPIN and multi-emitter/SPIN configurations using an equimolar solution of nine peptides. The highest instrument sensitivity was observed using the multi-emitter/SPIN configuration in which the sensitivity increased with the number of emitters in the array. Over an order of magnitude MS sensitivity improvement was achieved using multi-emitter/SPIN compared with using the standard atmospheric pressure single ESI emitter/heated capillary interface. Graphical Abstract
?  相似文献   

5.
Concentration sensitivity is a key performance indicator for analytical techniques including for capillary electrophoresis-mass spectrometry (CE–MS) with electrospray ionization (ESI). In this study, a flow-through microvial interface was used to couple CE with MS and improve the ESI stability and detection sensitivity. By infusing a peptide mixture through the interface into an MS detector at a typical flow rate for CE-MS analysis, the spatial region near the interface was mapped for MS signal intensity. When the sprayer tip was within a 6 × 6.5 × 5 mm region in front of the MS inlet, the ESI was stable with no significant loss of signal intensity for ions with m/z 239. Finite element simulations showed that the average electric field strength at the emitter tip did not change significantly with minor changes in emitter tip location. Experiments were conducted with four different mass spectrometer platforms coupled to CE via the flow-through microvial interface. Key performance indicators, that is, limit of detection (LOD) and linearity of calibration curves were measured for nine amino acids and five peptides. Inter- and intraday reproducibility were also tested. The results were shown to be suitable for quantification when internal standards were used.  相似文献   

6.
Wang F  Ye M  Dong J  Tian R  Hu L  Han G  Jiang X  Wu R  Zou H 《Journal of separation science》2008,31(14):2589-2597
The postcolumn void volume, which is introduced by the connecting tubing and void ESI emitter in the nanoflow LC coupled with MS/MS system (microLC-MS/MS), is harmful for the analysis of peptides in shotgun proteome analysis. A new type of porous C12 monolithic ESI emitter was prepared to eliminate the disruption and mixing effects occurring in the connecting tubing and void emitter. It was demonstrated that the porous hydrophobic monolith inside the emitter played a key role in retaining the good peak profile, and the average peak capacity of the whole separation system increased 12.8% in contrast to commercially available void emitter. Then, the porous C12 monolithic emitter was applied in label-free quantitative proteome analysis of two standard protein mixtures that were spiked into the tryptic digest of mouse livers extract. Compared to commercially available void ESI emitter, the number of proteins with reliable results in quantification increased greatly. And the relative quantities of the four standard proteins were all determined with the relative error < or = 6.8%. However, quantitative information of only three standard proteins could be obtained when void emitter was used.  相似文献   

7.
Chronoamperometry (CA) and cyclic voltammetry (CV) were used to compare the electrochemical behavior of metal, polymer and graphite coated nanospray emitters. It is shown that electrochemical reactions occurring at the emitter surface limit the lifetime of the noble metal coated nanospray emitters while the graphite coated nanospray emitters show good electrochemical stabilities. Although the surface of the graphite coated emitters may be passivated at positive potentials, the conductive coating is not lost as for the noble metal coated nanospray emitters. The graphite coated nanospray emitters still produced a stable nanospray signal despite the presence of a passivated surface. The polymer (i.e. polyaniline) coated nanospray emitters showed very low electrochemical activity and could not be thoroughly tested by CA. The relative short lifetimes seen in the electrochemical tests are qualitatively comparable with those obtained in nanospray experiments, in which only the outmost tip of the emitter is electrochemically active. However, the electrochemical stress during CA far exceeds the stress during ESI, which implies that CA can be used to perform quick and simple estimates of emitter stabilities. To our knowledge, this is the first time the electrochemical behavior of metal, polymer and graphite coated nanospray emitters has been compared.  相似文献   

8.
An emitter electrode with an electroactive poly(pyrrole) (PPy) polymer film coating was constructed for use in electrospray ionization mass spectrometry (ESI‐MS). The PPy film acted as a surface‐attached redox buffer limiting the interfacial potential of the emitter electrode. While extensive oxidation of selected analytes (reserpine and amodiaquine) was observed in positive ion mode ESI using a bare metal (gold) emitter electrode, the oxidation was suppressed for these same analytes when using the PPy‐coated electrode. A semi‐quantitative relationship between the rate of oxidation observed and the interfacial potential of the emitter electrode was shown. The redox buffer capacity, and therefore the lifetime of the redox buffering effect, correlated with the oxidation potential of the analyte and with the magnitude of the film charge capacity. Online reduction of the PPy polymer layer using negative ion mode ESI between analyte injections was shown to successfully restore the redox buffering capacity of the polymer film to its initial state. Published in 2010 by John Wiley & Sons, Ltd.  相似文献   

9.
An ESI emitter made of poly(dimethylsiloxane) interfaces on-chip sample preparation with MS detection. The unique multilayer design allows both the analyte and the spray solutions to reside on the device simultaneously in discrete microfluidic environments that are spatially separated by a polycarbonate track-etched, nanocapillary array membrane (NCAM). In direct spray mode, voltage is applied to the microchannel containing a spray solution delivered via a syringe pump. For injection, the spray potential is lowered and a voltage is applied that forward biases the membrane and permits the analyte to enter the spray channel. Once the injection is complete, the bias potential is switched off, and the spray voltage is increased to generate the ESI of the injected analyte plug. Consecutive injections of a 10 microM bovine insulin solution are reproducible and produce sample plugs with limited band broadening and high quality mass spectra. Peptide signals are observed following transport through the NCAM, even when the peptide is dissolved in solutions containing up to 20% seawater. The multilayer emitter shows great potential for performing multidimensional chemical manipulations on-chip, followed by direct ESI with negligible dead volume for online MS analysis.  相似文献   

10.
Despite the tremendous sensitivity and lower sample requirements for nanospray vs. conventional electrospray, metallized nanospray emitters have suffered from one of two problems: low mechanical stability (leading to emitter failure) or lengthy, tedious production methods. Here, we describe a simple alternative to metallized tips using polyaniline (PANI), a synthetic polymer well known for its high conductivity, anticorrosion properties, antistatic properties, and mechanical stability. A simple method for coating borosilicate emitters (1.2 mm o.d.) pulled to fine tapers (4 ± 1 μm) with water-soluble and xylene-soluble dispersions of conductive polyaniline (which allows for electrical contact at the emitter outlet) is described. The polyaniline-coated emitters show high durability and are resistant to electrical discharge, likely because of the thick (yet optically transparent) coatings; a single emitter can be used over a period of days for multiple samples with no visible indication of the destruction of the polyaniline coating. The optical transparency of the coating also allows the user to visualize the sample plug loaded into the emitter. Examples of nanospray using coatings of the water-soluble and xylene-soluble polyaniline dispersions are given. A comparison of PANI-coated and gold-coated nanospray emitters to conventional electrospray ionization (ESI) show that PANI-coated emitters provide similar enhanced sensitivity that gold-coated emitters exhibit vs. conventional ESI.  相似文献   

11.
We have developed a novel sheath-flow interface for low-flow electrospray ionization mass spectrometry (ESI-MS) and capillary electrophoresis/electrospray mass spectrometry (CE/ESI-MS). The interface is composed of two capillaries. One is a tapered fused-silica ESI emitter suitable for microliter and nanoliter flow rate electrospray and the other is a tail-end gold-coated CE separation column that is inserted into the emitter. A sheath liquid is supplied between the column and the emitter capillaries. The gold coating and the sheath liquid are used as the conducting media for ESI and the CE circuit. This novel design was initially evaluated by an infusion ESI-MS analysis of the most common antiretroviral dideoxynucleosides, followed by CE/MS coupling analysis of several antidepressant drugs. With infusion studies, the effects of the sheath liquid and the sample flow rates on detection sensitivity and signal stability were investigated. For an emitter with an internal diameter of 30 microm, the optimum flow rates for the sheath and the sample were 200 and 300 nL/min, respectively. The main improvement of this approach in comparison with conventional sheath liquid approaches using an ionspray interface is the gain in sensitivity. Sensitivities were three times better for dideoxynucleosides analyzed by infusion and 12 times higher for antidepressant drugs analyzed by CE/MS with this interface compared with ionspray. The emitter is durable, disposable, and simple to fabricate.  相似文献   

12.
The ejection of solvated small ions from nanometer-sized droplets plays a central role during electrospray ionization (ESI). Molecular dynamics (MD) simulations can provide insights into the nanodroplet behavior. Earlier MD studies have largely focused on aqueous systems, whereas most practical ESI applications involve the use of organic cosolvents. We conduct simulations on mixed water/methanol droplets that carry excess NH(4)(+) ions. Methanol is found to compromise the H-bonding network, resulting in greatly increased rates of ion ejection and solvent evaporation. Considerable differences in the water and methanol escape rates cause time-dependent changes in droplet composition. Segregation occurs at low methanol concentration, such that layered droplets with a methanol-enriched periphery are formed. This phenomenon will enhance the partitioning of analyte molecules, with possible implications for their ESI efficiencies. Solvated ions are ejected from the tip of surface protrusions. Solvent bridging prior to ion secession is more extensive for methanol/water droplets than for purely aqueous systems. The ejection of solvated NH(4)(+) is visualized as diffusion-mediated escape from a metastable basin. The process involves thermally activated crossing of a ~30 kJ mol(-1) free energy barrier, in close agreement with the predictions of the classical ion evaporation model.  相似文献   

13.
Electrospray ionization (ESI) mass spectrometry (MS) has proven to be an extremely powerful technique for studying the stoichiometry and binding strength of peptide-metal complexes. We have found a significant new problem in the ESI-MS of zinc-peptide systems involving the deposition of zinc in the ESI emitter. This deposition of zinc during the experiment removes a significant amount of zinc ions from the solution, impacting the resulting mass spectral intensities used to quantify the amount of the zinc-bound species. Analysis of infused zinc-peptide samples with atomic absorption spectrometry and with a custom-built nanoflow ESI source confirms the alteration of the analyte solutions with positive or negative or no potential applied to the emitter. Ultimately, the location of the zinc deposition was determined to be the stainless steel emitter. The use of a custom-built nanoESI interface using glass emitters was found to mitigate the zinc deposition problem. The phenomenon of metal deposition warrants further investigation as it may not be limited to just zinc and may represent a significant obstacle in the ESI-MS analysis of all protein-metal systems.  相似文献   

14.
An experimental and computational investigation of the effects of local fluid shear rate on the aggregation and breakage of approximately 10 microm latex spheres suspended in an aqueous solution undergoing laminar Taylor-Couette flow was carried out according to the following program. First, computational fluid dynamics (CFD) simulations were performed and the flow field predictions were validated with data from particle image velocimetry experiments. Subsequently, the quadrature method of moments (QMOM) was implemented into the CFD code to obtain predictions for mean particle size that account for the effects of local shear rate on the aggregation and breakage. These predictions were then compared with experimental data for latex sphere aggregates (using an in situ optical imaging method) and with predictions using spatial average shear rates. The mean particle size evolution predicted by CFD and QMOM using appropriate kinetic expressions that incorporate information concerning the particle morphology (fractal dimension) and the local fluid viscous effects on aggregation collision efficiency match well with the experimental data.  相似文献   

15.
This paper presents a model that describes how liquid flow fills micro-fluidic components and networks. As an alternative to computational fluid dynamic (CFD) simulations, we use a constrained energy minimization approach. This approach is based on two assumptions that hold in many micro-fluidic devices: (i) The length scales are small, and we consider slow filling rates, hence fluid momentum and viscous terms are small compared to surface tension forces, consequently the liquid/gas interfaces can be viewed as a succession of quasi-steady equilibrium configurations. (ii) Any equilibrium configuration corresponds to a surface tension energy minima which is constrained by the device shape and the volume of liquid in the device. The model is developed for planar micro-fluidic devices, is based on a fundamental physical principle, and shows accurate agreement with experimental data. It takes us only a few minutes to evaluate the model for a planar component of any shape using the Surface Evolver software, and this is significantly less then the computer run time required for CFD simulations. Moreover, once a library of component models has been created (which takes less than an hour of computer time) it then takes only seconds to simulate different network architectures with thousands of components. This fast "reconfigure the network and simulate in seconds" capability is essential for the design of truly complex networks that will enable the next generation of passive, micro-fluidic, lab-on-a-chip systems.  相似文献   

16.
A new microfluidic mixer is presented consisting of a rectangular channel with grooves placed in the top and bottom. This not only increases the driving force behind the lateral flow, but allows for the formation of advection patterns that cannot be created with structures on the bottom alone. Chevrons, pointing in opposite directions on the top and bottom, are used to create a pair of vortices positioned side by side. Stripes running the width of the channel generate a pair of vertically stacked vortices. Computational fluid dynamics (CFD) simulations are used to model the behavior of the systems and provide velocity maps at cross-sections within the mixer. Experiments demonstrate the mixing that results when two segregated species enter the mixer side-by-side and pass through two cycles of the mixer (i.e., two alternating sets of four stripes and four chevrons).  相似文献   

17.
Electrodynamic ion funnels are used to enhance the transmission of ions in electrospray‐based ion injection systems in 0.1 to 30 Torr pressure range. Jet disrupters are commonly employed to prevent droplets and high pressure jets from entering subsequent vacuum regions. This study presents the simulation and testing of an ion funnel containing a jet disrupter using computational fluid dynamics (CFD) and SIMION ion trajectory simulations. Traditional modeling approaches have utilized approximations for the bulk fluid flow fields without including the time‐varying nature of the turbulent flow present in the system, thus yielding idealized results. In this study, the fluid flow fields are calculated using CFD. In an effort to include time dependence, a random velocity vector, whose magnitude is proportional to the square root of the turbulence kinetic energy, was calculated at each time step and added to the velocity of the background gas. These simulations predicted that the transmitted ion current is effectively modulated by the variation of the jet disrupter voltage. The addition of the random velocity vector produced results that closely matched the experiments. The simulations yielded the dependence of the transmission on the jet disrupter voltage, and the voltage necessary for maximum ion throughput was accurately predicted. In addition, the magnitude of the predicted transmission closely matched that of the experimental results. This modeling approach could be extended to similar ion transport and filtering systems in which the effects of turbulent fluid flow cannot be ignored. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

18.
High mass measurement accuracy (MMA) is demonstrated for intact proteins and subsequent collision-induced dissociation product ions using internal calibration. Internal calibration was accomplished using a dual electrospray ionization source coupled with a hybrid quadrupole Fourier transform ion cyclotron resonance (Q-FT-ICR) mass spectrometer. Initially, analyte ions generated via the first electrospray (ESI) emitter are isolated and dissociated in the external quadrupole. This event is followed by a simultaneous switch to the calibrant ion ESI emitter and a disablement of the isolation and activation of the external quadrupole such that a broad m/z range of calibrant ions are accumulated before injecting the analyte/calibrant ion mixture into the ICR cell. Two different internal calibrant solutions were utilized in these studies to evaluate this approach for the top-down characterization of melittin and ubiquitin. While external calibration of protein fragments resulted in absolute MMA greater than 16 ppm, internal standardization significantly improved upon the MMA of both the intact proteins and their products ions which ranged from -2.0 ppm to 1.1 ppm, with an average of -0.9 ppm. This method requires limited modification to ESI-FT-ICR mass spectrometers and is applicable for both positive and negative ionization modes.  相似文献   

19.
A better understanding of nanoelectrospray ionization (nano‐ESI) would be beneficial in further improving the performances of nano‐ESI. In this work, the pulsed high‐voltage (HV) nano‐ESI has been electrically modeled and then systematically characterized by both voltage‐current and mass spectrometry measurements. First, the equivalent resistance of a nano‐ESI source changes with respect to both emitter tip diameter and the HV applied. Increased voltage could improve both spray current and ionization efficiency of the pulsed HV nano‐ESI. Compared with conventional DC HV method, a pulsed HV has less heating effect on the capillary tip and thus allowing the application of a much higher voltage onto a nano‐ESI source. As a result, a pulsed HV nano‐ESI could further boost the ionization efficiency of nano‐ESI by employing even higher voltages than conventional DC nano‐ESI sources.  相似文献   

20.
We present a detailed optimization and characterization of the analytical performance of SU-8-based emitters for electrospray ionization mass spectrometry (ESI/MS). The improved SU-8 fabrication process presented here enhances patterning accuracy and reduces the time and cost of fabrication. All emitters are freestanding and enable sample delivery by both pressure-driven and spontaneous flows. The optimized emitter design incorporates a sharp, double-cantilevered tip implemented to the outlet of an SU-8 microchannel and provides highly sensitive ESI/MS detection. Moreover, the optimized design allows the use of relatively large microchannel dimensions (up to 200 x 50 microm(2), w x h) without sacrificing the detection sensitivity. This is advantageous with a view of preventing emitter clogging and enabling reproducible analysis. The measured limits of detection for the optimized emitter design were 1 nM for verapamil and 4 nM for Glu-fibrinopeptide B with good quantitative linearities between 1 nM and 10 microM (R(2) = 0.9998) for verapamil and between 4 nM and 3 microM (R(2) = 0.9992) for Glu-fibrinopeptide B. The measured tip-to-tip repeatability for signal intensity was 14% relative standard deviation (RSD) (n = 3; 5 microM verapamil) and run-to-run repeatability 4-11% RSD (n = 4; 5 microM verapamil) for all individual emitters tested. In addition, long-term stability of < 2% RSD was maintained for timescales of 30 min even under free flow conditions. SU-8 polymer was also shown to be chemically stable against most of the tested electrospray solvents.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号