首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 125 毫秒
1.
Binary mixtures of two ionic liquids (ILs), 1-butyl-3-methylimidazolium chloride (BMIM-Cl) and 1-butyl-3-methylimidazolium bis[(trifluoromethyl)sulfonyl]imide (BMIM-NTf2), have been studied for the first time as gas chromatographic stationary phases. The two ILs differ only in the nature of the associated anion. The solvation parameter model was used to examine the change of solvation interactions with the IL stationary phase composition. The hydrogen bond basicity increased linearly as the stationary phase was enriched with the BMIM-Cl IL. The retention factor of short-chained alcohols increased by as much as 1100% when performing the separation on a column containing an IL mixture of 25% BMIM-NTf2/75% BMIM-Cl compared to that of the neat BMIM-NTf2 IL column. By tuning the composition of the IL-stationary phase, the separation selectivity and resolution factors of alcohols and aromatic compounds were improved. A reversal of elution order was observed for specific classes of analytes with enhancements in the stationary phase hydrogen bond basicity.  相似文献   

2.
Herein the structure of the interfacial layer between the air- and water-stable ionic liquid 1-ethyl-3-methylimidazolium tris(pentafluoroethyl)trifluorophosphate ([EMIM]FAP) and Au(111) is investigated using in situ scanning tunneling microscopy (STM), distance tunneling spectroscopy (DTS) and cyclic voltammetry (CV) measurements. The in situ STM measurements reveal that structured interfacial layers can be probed in both cathodic and anodic regimes at the IL/Au(111) interface. The structure of these layers is dependent on the applied electrode potential, the number of subsequent STM scans and the scan rate. Furthermore, first DTS results show that the tunneling barrier during the 1st STM scan does not seem to change significantly in the cathodic potential regime between the ocp (-0.2 V) and -2.0 V.  相似文献   

3.
In the present study, a rapid, highly efficient and environmentally friendly sample preparation method named temperature-controlled ionic liquid dispersive liquid-phase microextraction (TC-IL-DLPME), followed by high performance liquid chromatography (HPLC) was developed for the extraction, preconcentration and determination of four benzophenone-type ultraviolet (UV) filters (viz. benzophenone (BP), 2-hydroxy-4-methoxybenzophenone (BP-3), ethylhexyl salicylate (EHS) and homosalate (HMS)) from water samples. An ultra-hydrophobic ionic liquid (IL) 1-hexyl-3-methylimidazolium tris(pentafluoroethyl)trifluorophosphate ([HMIM][FAP]), was used as the extraction solvent in TC-IL-DLPME. Temperature served two functions here, the promotion of the dispersal of the IL to the aqueous sample solution to form infinitesimal IL drops and increase the interface between them and the target analytes (at high temperature), and the facilitation of mass transfer between the phases, and achievement of phase separation (at low temperature). Due to the ultra-hydrophobic feature and high density of the extraction solvent, complete phase separation could be effected by centrifugation. Moreover, no disperser solvent was required. Another prominent feature of the procedure was the combination of extraction and centrifugation in a single step, which not only greatly reduced the total analysis time for TC-IL-DLPME but also simplified the sample preparation procedure. Various parameters that affected the extraction efficiency (such as type and volume of extraction solvent, temperature, salt addition, extraction time and pH) were evaluated. Under optimal conditions, the proposed method provided good enrichment factors in the range of 240–350, and relative standard deviations (n = 5) below 6.3%. The limits of detection were in the range of 0.2–5.0 ng/mL, depending on the analytes. The linearities were between 1 and 500 ng/mL for BP, 5 and 1000 ng/mL for BP-3, 10 and 1000 ng/mL for HMS and 5 and 1000 ng/mL for EHS. Finally, the proposed method was successfully applied to the determination of UV filters in swimming pool and tap water samples and acceptable relative recoveries over the range of 88.0–116.0% were obtained.  相似文献   

4.
The enthalpies of vaporisation, Δ(vap)H(298), of seven ionic liquids (ILs) (four imidazoliums, a pyridinium, a phosphonium and an isouronium) have been determined by temperature programmed desorption using line of sight mass spectrometry. They were: 1-ethyl-3-methylimidazolium bis(pentafluoroethyl)phosphinate, [C(2)C(1)Im][PO(2)(C(2)F(5))(2)]; 1-butyl-3-methylimidazolium octylsulfate, [C(4)C(1)Im][C(8)OSO(3)]; 1-butyl-3-methylimidazolium tetrafluoroborate, [C(4)C(1)Im][BF(4)]; 1-hexyl-3-methylimidazolium tris(pentafluoroethyl)trifluorophosphate, [C(6)C(1)Im][FAP]; 1-butylpyridinium methylsulfate, [C(4)Py][C(1)OSO(3)]; trihexyl(tetradecyl)phosphonium tetrafluoroborate, [P(6,6,6,14)][BF(4)] and O-ethyl-N,N,N',N'-tetramethylisouronium trifluoromethanesulfonate, [C(2)(C(1))(4)iU][TfO]. The values were found to be consistent with a previously proposed, predictive, model in which Δ(vap)H(298) is decomposed into a Coulombic component (computable from the IL density) and van der Waals components from the anion and cation. Two previously predicted values of Δ(vap)H(298) were found to be within 6 kJ mol(-1) of the measured experimental values. Values for the van der Waals components are tabulated for eleven cations and twelve anions. Predictions are made for Δ(vap)H(298) for 13 ILs with as yet unmeasured Δ(vap)H(298) values (using experimental molar volumes), and for a further 44 ILs using estimated molar volumes.  相似文献   

5.
A novel dispersive liquid–liquid microextraction (DLLME) method followed by HPLC analysis, termed sequential DLLME, was developed for the preconcentration and determination of aryloxyphenoxy‐propionate herbicides (i.e. haloxyfop‐R‐methyl, cyhalofop‐butyl, fenoxaprop‐P‐ethyl, and fluazifop‐P‐butyl) in aqueous samples. The method is based on the combination of ultrasound‐assisted DLLME with in situ ionic liquid (IL) DLLME into one extraction procedure and achieved better performance than widely used DLLME procedures. Chlorobenzene was used as the extraction solvent during the first extraction. Hydrophilic IL 1‐octyl‐3‐methylimidazolium chloride was used as a dispersive solvent during the first extraction and as an extraction solvent during the second extraction after an in situ chloride exchange by bis[(trifluoromethane)sulfonyl]imide. Several experimental parameters affecting the extraction efficiency were studied and optimized with the design of experiments using MINITAB® 16 software. Under the optimized conditions, the extractions resulted in analyte recoveries of 78–91%. The correlation coefficients of the calibration curves ranged from 0.9994 to 0.9997 at concentrations of 10–300, 15–300, and 20–300 μg L?1. The relative SDs (n = 5) ranged from 2.9 to 5.4%. The LODs for the four herbicides were between 1.50 and 6.12 μg L?1.  相似文献   

6.
In the present study, a rapid, highly efficient and environmentally friendly sample preparation method named ionic liquid-based ultrasound-assisted dispersive liquid–liquid microextraction (IL-USA-DLLME), followed by high performance liquid chromatography (HPLC) has been developed for the extraction and preconcentration of four benzophenone-type ultraviolet (UV) filters (viz. benzophenone (BP), 2-hydroxy-4-methoxybenzophenone (BP-3), ethylhexyl salicylate (EHS) and homosalate (HMS)) from three different water matrices. The procedure was based on a ternary solvent system containing tiny droplets of ionic liquid (IL) in the sample solution formed by dissolving an appropriate amount of the IL extraction solvent 1-hexyl-3-methylimidazolium tris(pentafluoroethyl)trifluorophosphate ([HMIM][FAP]) in a small amount of water-miscible dispersive solvent (methanol). An ultrasound-assisted process was applied to accelerate the formation of the fine cloudy solution, which markedly increased the extraction efficiency and reduced the equilibrium time. Various parameters that affected the extraction efficiency (such as type and volume of extraction and dispersive solvents, ionic strength, pH and extraction time) were evaluated. Under optimal conditions, the proposed method provided good enrichment factors in the range of 354–464, and good repeatability of the extractions (RSDs below 6.3%, n = 5). The limits of detection were in the range of 0.2–5.0 ng mL−1, depending on the analytes. The linearities were between 1 and 500 ng mL−1 for BP, 5 and 500 ng mL−1 for BP-3 and HMS and 10 and 500 ng mL−1 for EHS. Finally, the proposed method was successfully applied to the determination of UV filters in river, swimming pool and tap water samples and acceptable relative recoveries over the range of 71.0–118.0% were obtained.  相似文献   

7.
In this article, a novel and simple microextraction method, termed ionic liquid/ionic liquid dispersive liquid–liquid microextraction (IL/IL‐DLLME), has been designed and developed for the rapid enrichment and analysis of environmental pollutants. Instead of using hazardous organic solvents, two kinds of ILs, hydrophobic IL and hydrophilic IL, were used as extraction solvent and disperser solvent in IL/IL‐DLLME step, respectively. Permethrin and biphenthrin, two of the often‐used pyrethroid pesticides, were used as model compounds. Factors that may affect the enrichment efficiencies were investigated and optimized in detail. Under optimum conditions, permethrin and biphenthrin exhibited a wide linear relationship over the range 1–100 μg/L. For permethrin and biphenthrin, the precisions were 4.65–7.78%, and limits of detection were found to be 0.28 and 0.83 μg/L, respectively. Satisfactory results were achieved when the present method was applied to analyze the target compounds in real‐world water samples with spiked recoveries over the range 84.1–113.5%. All these facts indicated that IL/IL‐DLLME is a simple and rapid alternative for the enrichment and analysis of environmental pollutants and will have a wide application perspective in the future.  相似文献   

8.
In this work, an ionic liquid-dispersive liquid-liquid microextraction (IL-DLLME) procedure was developed for the extraction of a group of pesticides (carbendazim/benomyl, thiabendazole, fuberidazole, carbaryl and triazophos) and some of their key metabolites in soils (2-aminobenzimidazole, metabolite of carbendazim and 1-naphthol, metabolite of carbaryl) from aqueous soil extracts, using high performance liquid chromatography (HPLC) with fluorescence detection (FD). Analytes were previously extracted from four soils with different physicochemical properties (forestal, ornamental, garden and lapilli soils) by ultrasound-assisted extraction (USE). The IL 1-hexyl-3-methylimidazolium hexafluorophosphate ([HMIm][PF(6)]) and methanol (MeOH) were used as extraction and dispersion solvent, respectively, for the DLLME procedure. Factors affecting IL-DLLME (sample pH, IL amount, volume of dispersion solvent and sodium chloride percentage) were optimized by means of an experimental design, obtaining the most favorable results when using 117.5 mg of IL and 418 μL of MeOH to extract the compounds from the aqueous soil extracts at pH 5.20 containing 30% (w/v) NaCl. Calibration of the USE-IL-DLLME-HPLC-FD method was carried out for every type of soil and accuracy and precision studies were developed at two levels of concentration, finding that no significant differences existed between real and spiked concentrations (Student's t test). LODs achieved were in the low ng/g range.  相似文献   

9.
A novel approach for preconcentration and speciation analysis of trace amount of mercury from water samples was proposed by dispersive liquid–liquid microextraction (DLLME) coupled to high performance liquid chromatography with diode array detection (HPLC-DAD). Mercury species (Hg2+, methylmercury (MeHg+) and phenylmercury (PhHg+)) were complexed with dithizone (DZ) to form hydrophobic chelates and then extracted into the fine drops of extraction solvent dispersed in the aqueous sample by dispersive solvent. After extraction, the sedimented phase was analyzed by HPLC-DAD. Some important parameters affecting the DLLME such as extraction solvent and dispersive solvent type and volume, concentration of dithizone solution, sample pH, extraction time and salt effect were investigated. Ionic liquid 1-hexyl-3-methylimidazolium hexafluorophosphate ([HMIM][PF6]) was found to be a suitable extractant for the chelates. Under the optimized conditions (extraction solvent: 70 μL of ionic liquid 1-hexyl-3-methylimidazolium hexafluorophosphate ([HMIM][PF6]); dispersive solvent: 0.75 mL of methanol containing dithizone (0.02%, m/v); pH: 4; extraction time: 5 min; and without salt addition), the limits of detection for Hg2+, MeHg+ and PhHg+ were 0.32, 0.96 and 1.91 μg L−1 (S N−1 = 3) respectively, and the relative standard deviation (RSD) was between 4.1 and 7.3% (n = 5). Three real water samples (tap water, river water and lake water) spiked with mercury species were detected by the developed method, and the relative recoveries obtained for Hg2+, MeHg+ and PhHg+ were 89.6–101.3%, 85.6–102.0% and 81.3–97.6%, respectively.  相似文献   

10.
Ionic liquid-based dispersive liquid-liquid microextraction was developed for the extraction and preconcentration of aromatic amine from environmental water. A suitable mixture of extraction solvent (100 μL, 1-butyl-3-methylimidazolium hexafluorophoshate) and dispersive solvent (750 μL, methanol) were injected into the aqueous samples (10.00 mL), forming a cloudy solution. After centrifuging, enriched analytes in the sediment phase were determined by HPLC-UV. The effect of various factors, such as the extraction and dispersive solvent, sample pH, extraction time and salt effect were investigated. Under optimum conditions, enrichment factors for 2-anilinoethanol, o-chloroaniline and 4-bromo-N,N-dimethylaniline were above 50 and the limits of detection (LODs) were 0.023, 0.015 and 0.026 ng/mL, respectively. Their linear ranges were 0.8-400 ng/mL for 2-anilinoethanol, 0.5-200 ng/mL for o-chloroaniline and 0.4-200 ng/mL for 4-bromo-N,N-dimethylaniline, respectively. Relative standard deviations (RSDs) were below 5.0%. The relative recoveries from samples of environmental water were in the range of 82.0-94.0%. Compared with other methods, dispersive liquid-liquid microextraction is simple, rapid, sensitive and economical.  相似文献   

11.
A dispersive liquid-liquid microextraction (DLLME) method using in situ halide exchange reaction to form ionic liquid (IL) extraction phase was developed to determine four insecticides (i.e. methoxyfenozide, tetrachlorvinphos, thiamethoxam, and diafenthiuron) in water samples. The preconcentration procedure, followed by high-performance liquid chromatography and variable wavelength detectors (VWD), enabled the formation of the immiscible IL extraction phase; the insecticides were transferred into the IL phase simultaneously, which enhanced the efficiency and sufficiency, greatly shortening the operation time. The experimental parameters affecting the extraction efficiency including volume of extraction IL, extraction and centrifugation times, volume of the sample solution and exchanging reagent, and addition of organic solvent and salt were investigated and optimized. Under optimized conditions, the extractions yielded recoveries of the target analytes from 82 to 102%. The calibration curves were linear, and the correlation coefficient ranged from 0.9990 to 0.9999 under the concentration levels of 5-200 μg/L. The relative standard deviation (n=6) was 2.9-4.6%. The limits of detection (LODs) for the four insecticides were between 0.98 and 2.54 μg/L.  相似文献   

12.
In this study, silica modified with a 30‐membered macrocyclic polyamine was synthesized and first used as an adsorbent material in SPE. The SPE was further combined with ionic liquid (IL) dispersive liquid–liquid microextraction (DLLME). Five polycyclic aromatic hydrocarbons were employed as model analytes to evaluate the extraction procedure and were determined by HPLC combined with UV/Vis detection. Acetone was used as the elution solvent in SPE as well as the dispersive solvent in DLLME. The enrichment of analytes was achieved using the 1,3‐dibutylimidazolium bis[(trifluoromethyl)sulfonyl]imide IL/acetone/water system. Experimental conditions for the overall macrocycle‐SPE–IL‐DLLME method, such as the amount of adsorbent, sample solution volume, sample solution pH, type of elution solvent as well as addition of salt, were studied and optimized. The developed method could be successfully applied to the analysis of four real water samples. The macrocyclic polyamine offered higher extraction efficiency for analytes compared with commercially available C18 cartridge, and the developed method provided higher enrichment factors (2768–5409) for model analytes compared with the single DLLME. Good linearity with the correlation coefficients ranging from 0.9983 to 0.9999 and LODs as low as 0.002 μg/L were obtained in the proposed method.  相似文献   

13.
In this work, the potential of a symmetric dialkyl‐substituted ionic liquid (IL), 1,3‐dipenthylimidazolium hexafluorophosphate ([PPIm][PF6]), as extraction solvent in dispersive liquid–liquid microextraction (DLLME) has been studied for the analysis of a group of three natural (estriol, 17β‐estradiol, and 17α‐estradiol) and four synthetic (17α‐ethynylestradiol, diethylstibestrol, dienestrol, and hexestrol) estrogenic compounds as well as one mycotoxin with estrogenic activity (zearalenone) in different types of water samples (Milli‐Q, mineral, and wastewater). Separation, determination, and quantification were developed by HPLC‐DAD and a fluorescence detector (FD) connected in series. Factors influencing the IL‐DLLME procedure (sample pH, amount of IL, type and volume of disperser solvent, ionic strength, and assistance of vortex agitation) were investigated and optimized by means of a step‐by‐step approach. Once the optimum extraction conditions were established (10 mL of water at pH 8, 60 mg of [PPIm][PF6], 500 μL of ACN as disperser solvent and vortex agitation for 1 min), the calibration curves of the whole method (IL‐DLLME‐HPLC‐DAD/FD) were obtained and precision and accuracy were evaluated. It was demonstrated that the developed methodology was repeatable, accurate, and selective with limits of detection in the 0.30–0.57 μg/L and 13.8–37.1 μg/L range for FD and DAD, respectively. Relative recovery values were higher than 85% for the different types of water samples and the Student's t test demonstrated that there were not significant differences between the added and the found concentration.  相似文献   

14.
Using 1-butyl-3-methylimidazolium hexa?uorophosphate ([BMIM][PF6]) room temperature ionic liquid (RTIL) as extraction solvent, tetrahydrofuran (THF) as disperser solvent, the organophosphorus pesticide dichlorvos in water was determined by dispersive liquid-liquid microextraction (DLLME) combined with high-performance liquid chromatography. Factors affecting RTIL-DLLME (type of disperser solvent, amount of RTIL, volume of disperser solvent, percentage of NaCl and volume and pH of water sample) were optimized by the single-factor method, obtaining the most favorable results when using 65 μL of [BMIM][PF6] and 260 μL of THF to extract the compound from an 8-mL water sample at pH 5.0 containing 25% (w/v) of NaCl. Under these optimum conditions, an enrichment factor of 215-fold was obtained. The calibration curves were linear in the concentration range of 2-1,000 μg/L. The limit of detection calculated at a signal-to-noise ratio of 3 was 0.2 μg/L. The relative standard deviations (RSD) for six replicate experiments at 20, 100 and 200 μg/L concentration levels were 1.8%, 1.3% and 1.3 %, respectively. Then the proposed method was applied to the analysis of three different water sample sources (tap, farm and rain water) and the relative recoveries and RSD of spiked water samples were 95.6-102.4% and 0.6-3.1%, respectively, at three different concentration levels of 20, 100 and 200 μg/L.  相似文献   

15.
We present for the first time Gutmann donor and acceptor numbers for a series of 36 different ionic liquids that include 26 distinct anions. The donor numbers were obtained by (23) Na?NMR spectroscopy and show a strong dependence on the anionic component of the ionic liquid. The donor numbers measured vary from -12.3?kcal?mol(-1) for the ionic liquid containing the weakest coordinative anion [emim][FAP] (1-ethyl-3-methylimidazolium tris(pentafluoroethyl)trifluorophosphate), which is a weaker donor than 1,2-dichloroethane, to 76.7?kcal?mol(-1) found for the ionic liquid [emim][Br], which exhibits a coordinative strength in the range of tertiary amines. The acceptor numbers were measured by using (31) P?NMR spectroscopy and also vary as a function of the anionic and cationic component of the ionic liquid. The data are presented and correlated with other solvent parameters like the Kamlet-Taft set of parameters, and compared to the donor numbers reported by other groups.  相似文献   

16.
以苄基功能化的离子液体1-苄基-3-甲基咪唑双三氟甲烷磺酰亚胺(1-Benzyl-3-methylimidazolium bis [(trifluoromethyl)sulfonyl]imide,[BeMIM][Tf2 N])作为分散液-液微萃取的萃取剂,与高效液相色谱联用,用于环境水样中5种有机磷农药(辛硫磷、杀螟松、毒死蜱、甲拌磷和对硫磷)以及2种苯环化合物(氯化萘和蒽)的萃取与富集。并与其它离子液体([OMIM][Tf2 N])以及普通有机溶剂(CCl4和 C2 Cl4)的萃取效能进行了对比。萃取优化条件为:40μL [BeMIM][Tf2 N]作为萃取剂,1 mL 甲醇作为分散剂,离心时间5 min,样品溶液中不添加盐。在优化的条件下,本方法的线性关系良好(R2=0.9994~0.9998);对10,40和100μg/ L 不同添加浓度重复测定5次的日内和日间 RSD 分别为1.1%~4.3%和0.8%~4.8%,LOD 为0.01~1.0μg/ L (S/ N=3)。将本方法用于3种实际水样中目标分析物的测定,加标回收率和 RSD 分别为82.7%~118.3%和0.7%~5.6%。由于在咪唑环上引入了苄基基团,[BeMIM][Tf2 N]与目标分析物之间除存在疏水作用外,还存在π-π作用,故对目标物的萃取效率明显提高,富集倍数和回收率分别高达339和81.4%。测定了分析物在[BeMIM][Tf2 N]-DLLME 体系中的分配系数,对萃取机制进行初步探讨。  相似文献   

17.
Chromatographic retention data were measured for a wide range of organic solutes on 1-butyl-1-methylpyrolidinium tris(pentafluoroethyl)trifluorophosphate ([BMPyrr]+[FAP]?), 1-butyl-1-methylpyrrolidinium triflate, ([BMPyrr]+[Trif]?), and 1-methoxyethyl-1-methylmorpholinium tris(pentafluoroethyl)trifluorophosphate, ([MeoeMMorp]+[FAP]?), stationary phases at (323, 353 and 383) K. The measured retention factors were combined with published infinite dilution activity coefficient and gas-to-water partition coefficient data to yield gas-to-anhydrous ionic liquid (IL) and water-to-anhydrous IL partition coefficients. The three sets of partition coefficients were analyzed using the Abraham model. The derived Abraham model correlations describe the observed gas-to-IL (log10 K) and water-to-IL (log10 P) partition coefficient data to within average standard deviations of about 0.11 and 0.15 log10 units, respectively.  相似文献   

18.
A novel microextraction method is introduced based on dispersive liquid–liquid microextraction (DLLME) in which an in situ metathesis reaction forms a water-immiscible ionic liquid (IL) that preconcentrates aromatic compounds from water followed by separation using high-performance liquid chromatography. The simultaneous extraction and metathesis reaction forming the IL-based extraction phase greatly decreases the extraction time as well as provides higher enrichment factors compared to traditional IL DLLME and direct immersion single-drop microextraction methods. The effects of various experimental parameters including type of extraction solvent, extraction and centrifugation times, volume of the sample solution, extraction IL and exchanging reagent, and addition of organic solvent and salt were investigated and optimized for the extraction of 13 aromatic compounds. The limits of detection for seven polycyclic aromatic hydrocarbons varied from 0.02 to 0.3 μg L−1. The method reproducibility produced relative standard deviation values ranging from 3.7% to 6.9%. Four real water samples including tap water, well water, creek water, and river water were analyzed and yielded recoveries ranging from 84% to 115%.   相似文献   

19.
Analysis of primary amines in aqueous samples remains a challenging analytical issue. The preferred approach by gas chromatography is hampered by interactions of free silanol groups with the highly reactive amine groups, resulting in inconsistent measurements. Here, we report a method for direct analysis of aliphatic amines and diamines in aqueous samples by gas chromatography (GC) with silanol deactivation using ionic liquids (ILs). ILs including trihexyl(tetradecyl)phosphonium bis 2,4,4-(trimethylpentyl)phosphinate (Cyphos IL-104), 1-methyl-3-propylimidazolium bis(trifluoromethylsulfonyl)imide [pmim][Tf(2)N] and N″-ethyl-N,N,N',N'-tetramethylguanidinium tris(pentafluoroethyl)trifluorophosphate [etmg][FAP] were tested as deactivating media for the GC liner. Solutions of these ILs in methanol were injected in the system prior to the analysis of primary amines. Butane-1,4-diamine (putrescine, BDA) was used as a reference amine. The best results were obtained using the imidazolium IL [pmim][Tf(2)N]. With this deactivator, excellent reproducibility of the analysis was achieved, and the detection limit of BDA was as low as 1mM. The applicability of the method was proven for the analysis of two different primary amines (C4-C5) and pentane-1,5-diamine.  相似文献   

20.
The use of Room Temperature Ionic Liquid (RTIL) electrolytes promises to improve the energy density of Electrochemical Capacitors (ECs) by allowing for operation at higher voltages. RTIL electrolytes 1-ethyl-3-methylimidazolium tetrafluoroborate (EMImBF(4)), 1-ethyl-3-methylimidazolium dicyanamide (EMImN(CN)(2)), 1,2-dimethyl-3-propylimidazolium bis(trifluoromethylsulfonyl)imide (DMPImTFSI), and 1-butyl-3-methylpyrrolidinium tris(pentafluoroethyl)trifluorophosphate (BMPyFAP) were studied. Tetraethylammonium tetrafluoroborate 1 molar solution in anhydrous propylene carbonate (Et(4)NBF(4)-PC 1M) was studied for comparison purposes. Carbon was produced from phenolic resin activated in CO(2). The porosity of the carbon samples were characterised by N(2) adsorption-desorption at 77 K and the relevant electrochemical behaviour was characterised by galvanostatic charge-discharge, electrochemical impedance spectroscopy and cyclic voltammetry. The highest operating voltage of 3.5 V was obtained for BMPyFAP, whilst the best capacitive performance was obtained for EMImBF(4). The maximum energy density increased to 70 Wh kg(-1) (carbon) for RTIL EMImBF(4) from 35 Wh kg(-1)(carbon) for the organic electrolyte Et(4)NBF(4)-PC 1M. It was found that the performance of the RTIL electrolytes could be related to the IL viscosity and ion size whilst the electrolyte equivalent series resistances produced a linear relationship with viscosity. It was found that the capacitance performance of the RTIL electrolytes followed the order EMImBF(4) > DMPImTFSI > BMPyFAP > EMImN(CN)(2). The electrolyte and equivalent series resistance were in the order EMImN(CN)(2) < EMImBF(4) < DMPImTFSI < BMPyFAP.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号