共查询到19条相似文献,搜索用时 93 毫秒
1.
2.
3.
4.
流动注射化学发光法测定甲氨蝶呤 总被引:8,自引:0,他引:8
研究了甲醛增强高锰酸钾与甲氨蝶呤的化学发光反应,由此建立了一种测定甲氨蝶呤的流动性注射化学发光分析法,方法的检出限为3.4×10^-9g/mL,相对标准偏差为1.1%(2.0×10^-6g/mL甲氨蝶呤,n=11)线性范围为1.0×10^-8~1.0×10^-5g/mL。该法已用于甲氨蝶呤针剂及片剂中甲氨蝶呤含量的测定。 相似文献
5.
6.
流动注射化学发光法测定利血平 总被引:9,自引:0,他引:9
研究了利血平在酸性条件下与高锰酸钾和过氧化氢产生化学发光的行为,建立了流动注射化学发光测定利血平的新方法。利血平的浓度在1.0×10^-6 ̄8.0×10^-5h/mL范围内与化学发光强度呈良好的线性关系;检出限为3×10^-7g/mL。对6×10^-6g/mL利血平进行11次平行测定,得方法的相对标准偏差为1.3%。方法用于药剂中利血平含量测定,结果与药典标准方法测得值一致。 相似文献
7.
8.
碱性条件下,N-溴代琥珀酰亚胺(NBSM)氧化西咪替丁,荧光素作为能量转移剂,在溴化十六烷基三甲基铵(CTMAB)的增敏作用下产生化学发光。基于此,结合流动注射技术,建立了测定西咪替丁的化学发光分析法,研究了影响化学发光强度的因素,并探讨了化学发光可能的机理。化学发光信号强度ΔI与西咪替丁的浓度在8×10-5~1×10-1g.L-1范围内呈线性关系,方法的检出限(3σ)为2.8×10-5g.L-1,对3×10-3g.L-1的西咪替丁进行了11次平行测定,相对标准偏差为1.4%,将方法用于西咪替丁胶囊中西咪替丁的定量分析,结果满意。 相似文献
9.
10.
11.
12.
13.
Qi H Lv J Li B 《Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy》2007,66(4-5):874-878
In this paper, a simple flow-injection chemiluminescence (CL) system combined with on-line solid-phase extraction is presented to determine phenol. This method is based on the enhancement effect of phenol on the luminol-K3Fe(CN)6 CL system. The solid-phase extraction promised the high sensitivity and improved selectivity of CL detection. With the calibration range from 4.7 ng l-1 to 470 ng l-1 phenol concentration, the proposed method was applied to analyzing phenol in water samples and the obtained results were validated by the standard method. The detection limit was determined as 0.66 ng l-1. The relative standard deviation was 1.5% for determining 4.7 ng l-1 phenol standard (n=7). 相似文献
14.
15.
16.
Amir Waseem Mohammad Yaqoob Masood Ahmed Siddiqui 《International journal of environmental analytical chemistry》2013,93(12):825-832
A flow-injection procedure is described for the determination of carbaryl based on its inhibition effect on luminol-cobalt(II) chemiluminescence reaction in alkaline medium in the presence of hydrogen peroxide. The calibration data over the range 5.0?×?10?7 to 20?×?10?6?M give a correlation coefficient (r 2) of 0.9972 with relative standard deviations (RSD; n?=?4) in the range of 1.0–2.1% with a limit of detection (3?×?blank noise) of 2.37?×?10?7?M for carbaryl. The sample throughput was 120?h?1. The effects of some carbamates, anions, and cations were studied on luminol CL system for carbaryl determination. The proposed method has been applied to determine carbaryl in natural waters. 相似文献
17.
18.
19.
The miniature flow injection analysis (μFIA) system is based on a mechanically engraved manifold in a PMMA-substrate. The channels have a trapezoidal cross-section with a depth of 150 μm and a width between 180 and 360 μm and the reactor volume is 3.75 μl. A light-emitting diode (LED) is used as radiation source for absorbance detection and optical fibres are used for transmitting light to and from the manifold. Computer controlled valves are used for directing the liquid flows maintained with syringe pumps. A sampling rate of approximately five determinations per minute was achieved with a reagent consumption of 10 μl min−1. Four applications were implemented and tested; the performance was found to be comparable to that obtained with conventional FIA-set-ups despite the drastically reduced optical pathlength. Electrokinetic pumping was extensively evaluated but found to generally be very restricted in scope because the reagent solutions cannot usually be adapted to the requirements for generating the flow. 相似文献