首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Huang HY  Lien WC 《Electrophoresis》2005,26(16):3134-3140
In this study, a microemulsion electrokinetic chromatography (MEEKC) method was developed to analyze and detect 13 phenolic compounds (syringic acid, p-cumaric acid, vanillic acid, caffeic acid, gallic acid, 3,4-dihydroxybenzoic acid, 4-hydroxybenzoic acid, (+)-catechin, (-)-epigallocatechin, (-)-epicatechin gallate, (-)-epigallocatechin gallate, (-)-epicatechin, and (-)-gallocatechin), which are present in many plant-derived foods. The effects of cosurfactant, organic modifier, and oil were examined in order to optimize the separation of these phenolic compounds. The amounts of cosurfactant (cyclohexanol) and organic modifier (acetonitrile) were determined as the major influence on the separation selectivity, while the type of oil partially affected the separation resolution of the phenolic compounds. A highly efficient MEEKC separation method was achieved within 14 min by using a microemulsion solution of pH 2.0 containing 2.89% w/v SDS, 1.36% w/v heptane, 7.66% w/v cyclohexanol, and 2% w/v ACN. Furthermore, the present work could demonstrate that the nature of the oil phase has a significant influence on the separation selectivity of phenolic compounds.  相似文献   

2.
The elution order of the hop α- and β-acids has been studied under different modes of electrokinetic separation. A model is advanced to explain the shorter migration times of the more hydrophobic β-acids compared to the α-acids in micellar electrokinetic chromatography (MEKC). For quality control of the bitter principles in hops, the ruggedness of electrokinetic separation could be improved by replacing MEKC by microemulsion electrokinetic chromatography (MEEKC).  相似文献   

3.
An homologous series of benzodiazepine retention index standards (the R-series) has been synthesized and the gas chromatographic behavior of the series investigated on NB-54 and NB-1701 capillary columns. The compounds were stable, exhibited symmetrical peak shapes, and fairly linear retention behavior was observed on both columns. The series can be coinjected with every sample to enable the high precision analysis of toxicological samples; screening for 20 benzodiazepine drugs was possible in 23 minutes (including cooling). The R-series method was compared with a retention index method based on a series of benzodiazepine drugs as standards and with a method employing relative retention times. The precision of the R-series method was found to be generally better than that of the two other methods in both long- and short-term studies.  相似文献   

4.
Tao Wen  Guoan Luo  Jian Wang  Bo Yao  Jun Zhu 《Talanta》2007,71(2):854-860
Microemulsion electrokinetic chromatography (MEEKC) and solvent modified micellar electrokinetic chromatography (MEKC) were investigated with the goal of the rapid separation of complex heroin and amphetamine samples. The rapid simultaneous separation of 17 species of heroin, amphetamine and their basic impurities and adulterants was performed within about 10 min using MEEKC for the first time, whereas solvent modified MEKCs were unable to resolve all the components. The comparisons between MEEKC and solvent modified MEKC proved internal lipophilic organic phase in microemulsions played an important role in improving the separation performance with respect to efficiency. However, the role of internal lipophilic organic phase in MEEKC was disgusted at high concentrations of cosurfactant, and the separations of MEEKC and 1-butanol modified MEKC became similar at high concentrations of 1-butanol. The evaluation of reproducibility, linearity and detection limit of optimized MEEKC method provided good results for all the analytes investigated, thus allowing its application to real controlled drug preparation analysis.  相似文献   

5.
In this work, the influences of ionic liquid (IL) as a modifier on microemulsion microstructure and separation performance in MEEKC were investigated. Experimental results showed that synergetic effect between IL 1‐butyl‐3‐methylimidazolium tetrafluoro‐borate (BmimBF4) and surfactant SDS gave a decreased CMC. With increment of IL in microemulsion, negative ζ potential of the microdroplets reduced gradually. The influence of IL on the dimensions of microdroplet was complicated. At BmimBF4 less than 8 mM, IL made microemulsion droplet smaller in size. While at BmimBF4 more than 10 mM, the size increased and reached to a maximum value at 12 mM, where the microdroplets were larger than that without IL. After that, the micreodroplet size decreased again. Relative fluorescence intensity of the first vibration band of pyrene to the third one (I1/I3) enhanced as IL was added to microemulsion, which indicated that this addition increased environmental polarity in the inner core of microdroplets. Prednisone, hydrocortisone, prednisolone, hydrocortisone acetate, cortisone acetate, prednisolone acetate, and triamcinolone acetonide were analyzed with MEEKC modified with IL to evaluate the separation performance. Cortisone acetate and prednisolone acetate could not be separated at all in typical microemulsion. The seven analytes could be separated by the addition of 10 mM BmimBF4 into the microemulsion system. The method has been used for analysis of corticosteroids in cosmetic samples with simple extraction; the recoveries for seven analytes were between 86 and 114%. This method provides accuracy, reproducibility, pretreatment simplicity, and could be applied to the quality control of cosmetics.  相似文献   

6.
A comparison between chiral cyclodextrin‐modified microemulsion electrokinetic chromatography (CD‐MEEKC) and cyclodextrin‐modified micellar electrokinetic chromatography (CD‐MEKC) for the enantiomeric separation of esbiothrin was carried out. For both methods, the separation conditions were optimized by varying CD types and concentration, running buffer pH and compositions, organic modifiers, and temperature. The optimal CD‐MEEKC conditions were 0.8% n‐heptane, 2.3% SDS, 6.6% n‐butanol, 90.3% 10 mM sodium tetraborate containing 3% (w/v, the ratio of CD mass to microemulsion volume) methyl‐β‐cyclodextrin, pH 10, 25°C. The optimized CD‐MEKC conditions were 3.3% SDS, 96.7% 10 mM sodium tetraborate containing 5% (w/v) β‐CD, pH 10, 25°C. The difference in physicochemical properties of the buffer and CDs resulted in different optimal CD type. The competitive distribution between the microemulsion (or micelle) and chiral CD contributed to the chiral separation. Both methods provided excellent separation (Rs ~? 3) with similar migration time (ca. 15 min). CD‐MEEKC provided higher separation efficiencies (>300000) than CD‐MEKC (>200000). The LODs for CD‐MEEKC and CD‐MEKC were 4.7 μg/mL and 3.2 μg/mL, respectively. The RSDs of migration time and peak area for CD‐MEEKC were slightly higher than for CD‐MEKC. Both the demonstrated CD‐MEEKC and CD‐MEKC methods provided high efficiencies, low LODs, and reproducible enantioseparations of esbiothrin.  相似文献   

7.
建立了微乳液毛细管电动色谱快速测定解热镇痛药中非那西丁、氨基比林和咖啡因的新方法。采用由乙酸乙酯-十二烷基硫酸钠(SDS)-正丁醇-硼砂缓冲液组成的微乳液体系,以氯霉素为内标,3种有效成分在2.5 min内完成分离,峰面积相对标准偏差(RSD)在1.2%~1.6%之间,回收率在95.6%~104.0%之间。实验考察了缓冲溶液的浓度、pH值、SDS浓度以及助表面活性剂的种类、含量对分离测定的影响。该法可用于实际样品分析。  相似文献   

8.
In this study, microemulsions of the chiral surfactant polysodium N-undecenoyl-D-valinate (poly-D-SUV) was utilized for enantiomeric separation by investigating two approaches using polymeric chiral surfactant in microemulsion electrokinetic chromatography (MEEKC). In the first approach, poly-D-SUV was used as an emulsifier surfactant along with 1-butanol and n-heptane. Enantioseparation of anionic or partially anionic binaphthyl derivatives, anionic barbiturates, and cationic paveroline derivatives were achieved by varying the mass fraction of 1-butanol, n-heptane and poly-D-SUV. For anionic or partially anionic analytes, relatively lower mass fractions of n-heptane, and poly-D-SUV were found to give optimum chiral separations as compared to that for cationic solutes. In the second approach, the chiral microemulsion polymer was prepared by polymerizing mixtures of 3.50% (w/w) of sodium N-undecenoyl-D-valinate (D-SUV) and 0.82% (w/w) of n-heptane (core phase) at varying concentration of 1-butanol. After polymerization, the n-heptane and 1-butanol were removed to yield solvent free microemulsion polymers (MPs) which were then utilized for the separation of anionic binaphthyl derivatives and anionic barbiturates. When MPs of D-SUV were utilized for chiral separation, 1.00% (w/w) 1-butanol and 3.50% (w/w) 1-butanol was optimum for enantioseparation of (+/-)-BNP and (+/-)-BOH, respectively. On the other hand, for anionic (+/-)-barbiturates very low concentration of butanol (0.25%, w/w) provided optimum resolution. Compared with micellar electrokinetic chromatography (MEKC), the use of micelle polymers or microemulsion polymers in MEEKC showed dramatic enhancement for resolution of (+/-)-BNP, while this enhancement was less dramatic for other binaphthyls [(+/-)-BOH, (+/-)-BNA] as well as for (+/-)-barbiturates and (+/-)-paveroline derivatives. However, higher separation efficiency of the enantiomers was always observed with MEEKC than in MEKC.  相似文献   

9.
Microemulsion electrokinetic chromatography (MEEKC) was developed for quantitative analysis of avermectins, such as abamectin, doramectin and ivermectin, in commercial formulations, using the microemulsion buffer containing a 50 mM phosphate buffer at pH 2.5, 1.1% (v/v) n-octane as oil droplets, 180 mM sodium dodecylsulphate as surfactant, 890 mM 1-butanol as co-surfactant and 30% (v/v) ethanol as organic co-solvent. High accuracy and precision of the method were obtained. The contents of avermectins in commercial formulations determined by MEEKC were found to be insignificantly different with those determined by high performance liquid chromatography (HPLC). Therefore, MEEKC can be used an alternative method to HPLC for quantitative determination of avermectins.  相似文献   

10.
Microemulsion electrokinetic chromatography (MEEKC) has been applied to the separation of some UV filters (Eusolex 4360, Eusolex 6300, Eusolex OCR, Eusolex 2292, Eusolex 6007, Eusolex 9020, Eusolex HMS, Eusolex OS, and Eusolex 232) commonly used in sunscreen lotions. Use of a MEEKC buffer with a mixed surfactant system to stabilize the oil droplets and an organic modifier in the aqueous phase allowed separation of most of the selected analytes in a single run in a system fitted with a diode array detector recording three wavelengths (240 nm, 300 nm, and 380 nm) simultaneously. The microemulsion employed consisted of 2.25 g of SDS, 0.75 g of Brij 35, 6.6 g 1‐butanol, 0.8 g n‐octane, 17.5 g 2‐propanol, and 72.1 g of 10 mM borate buffer (pH 9.2). Detection limits from 0.65 to 6.0 μg/mL were obtained and the calibration plots were linear over at least one order of magnitude for all analytes. The developed method could be applied to the determination of UV filters in several sun protection products including lotions, milks, and oils. Comparison of the obtained data with those from an HPLC method described in the literature showed acceptable agreement.  相似文献   

11.
A new method to influence the separation selectivity of inorganic cations in capillary electrophoresis is presented. This method combines the use of certain crown ethers to form complexes with a specific cation (changing its ionic radius/charge ratio and thereby its electrophoretic mobility) with partitioning of the crown ether/analyte complex between an aqueous phase and a pseudo-stationary phase, such as the oil droplet of a microemulsion. Several microemulsions, including uncharged oil droplets and oil droplets with different degrees of surface charge were tested to evaluate their ability to improve the separation of the selected analytes.  相似文献   

12.
Microemulsion EKC (MEEKC) was developed for quantitative analysis of curcuminoids, such as curcumin (C), demethoxycurcumin (D), and bis-demethoxycurcumin (B). MEEKC separation of curcuminoids was optimized, and a change in resolution was explained using a modified equation for resolution in MEEKC without electroosmosis. The suitable MEEKC conditions for separation of curcuminoids were obtained to be the microemulsion buffer containing 50 mM phosphate buffer at pH 2.5, 1.1% v/v n-octane as oil droplets, 180 mM SDS as surfactant, 890 mM 1-butanol as cosurfactant, and 25% v/v 2-propanol as organic cosolvent; applied voltage of -15 kV; and separation temperature 25 degrees C. Achieved baseline resolution of C:D and D:B was obtained with R(s) -2.4 and analysis time within 18 min. In addition, high accuracy and precision of the method were obtained. This MEEKC method was used for quantitative determination of individual curcuminoids in medicinal turmeric capsules and powdered turmeric used as coloring additive in food, with simple sample preparation such as solvent extraction, dilution, and filtration, and without cleaning up by SPE.  相似文献   

13.
14.
A novel method of microemulsion electrokinetic chromatography (MEEKC) coupled with hollow fiber-liquid phase microextraction (HF-LPME) was developed for determination of six aromatic amines including 4-methylaniline, 3-nitroaniline, 2,4-dimethylaniline, 4-chloroaniline, 3,4-dichloraniline and 4-aminobiphenyl. Baseline separation of six aromatic amines was achieved within 8 min by using the microemulsion buffer containing a 10 mM borate buffer at pH 9.0, 0.8% (v/v) ethyl acetate as oil droplets, 60 mM sodium cholate as surfactant, 5.0% (v/v) 1-butanol as co-surfactant. The influence factors relevant to the HF-LPME process were systemically investigated. The obtained enrichment factors were ranged between 70 and 157 in a 30 min extraction time, and the limits of detection ranged between 0.0021 and 0.0048 μg/mL. This purposed method was successfully applied for the analysis of aromatic amines in water sample and the recoveries were ranged from 87.2% to 99.8%.  相似文献   

15.
CE with conventional UV detection has recently been shown as a highly effective means to assaying cytotoxic gallium(III)-based compounds with regard to desirable drug-like properties such as the stability and binding to serum proteins. In this extension of that work, different CE techniques are used to further characterize a given set of gallium coordination compounds with established antiproliferating efficacy. Using free-zone CE mode, the electrophoretic profiles of complexes are recorded in order to assess their actual charge state under physiological buffer conditions. Micellar and microemulsion electrokinetic chromatographic techniques are tested as tools for the rapid estimation of the n-octanol-water partition coefficient (log P) that provides a rationale estimate of a drug's ability to cross biological membranes. A range of electrolyte buffer systems with varying (both in the nature and concentration) organic modifiers are examined to evaluate their effect on the relationship between experimental or calculated log P and the retention factors of compounds (log k'). Both methods were found to be better applicable for neutral than for cationic Ga complexes, the microemulsion mode demonstrating superior lipophilicity estimations as well as statistically meaningful log P versus log k' correlations when all the complexes were included in one regression set.  相似文献   

16.
Numerous combinations of one-, two-, and three-chiral-component microemulsions have been previously prepared in our group, using N-dodecoxycarbonylvaline (DDCV), 2-hexanol, and ethyl acetate, dibutyl tartrate, or diethyl tartrate. A few results of the various formulations investigated suggested the possible presence of minor impurities in one or more components of the microemulsion. In this study, the purity of the current lots of R- and S-surfactant were measured, as was the subsequent effect of minor impurities on the relevant chromatographic figures of merit (CFOMs) that describe a chiral separation, i.e., efficiency, enantioselectivity, retention, migration window (elution range), and resolution. Two related methods are proposed for correcting enantioselectivities measured in the presence of chiral impurities in the chiral microemulsion.  相似文献   

17.
Cao J  Dun WL 《Talanta》2011,84(1):155-159
In this report, a novel means for the separation and sweeping of flavonoids (quercetin, rutin, calycosin, ononin and calycosin-7-O-β-d-glucoside) by microemulsion electrokinetic chromatography using mixed anionic and cationic surfactants as modified pseudostationary phase was presented. The optimized background electrolyte consisted of 0.5% (w/v) ethyl acetate, 2.0% (w/v) SDS, 9 mM DTAC, 4.0% (w/v) 1-butanol and 10 mM sodium borate or 25 mM phosphoric acid. We systematically investigated the separation and preconcentration conditions, including the concentrations of surfactant, types of sweeping, sample matrix, the effect of high salt or acetonitrile, and sample injection volume. It was found that the use of mixed surfactants significantly enhanced the separation efficiency through the change of the efficient electrophoretic mobility of analytes. Compared with normal sample injection, 185-508-fold sensitivity enhancement in terms of limit of detection was achieved through effective sweeping of large sample volume at 50 mbar pressure (up to 45% capillary length). At last, the proposed method was suitable for the determination of Radix Astragali sample.  相似文献   

18.
Summary Correlations between retention index (RI) and Van der Waals' volume (VW) in homologous series of n-alcohols, n-aldehydes and esters are studied on the stationary phases Carbowax 1540 and squalane. Influence of functional groups is quantified and a method for obtaining one general equation, valid for an indeterminate number of homologous series, is proposed.  相似文献   

19.
Retention index (I), rather than retention factor (k), was found to be a more reasonable parameter for comparison of the relative affinity of disubstituted benzenes in MEEKC and MEKC, due to independent of I with the SDS surfactant concentration. MEKC and MEEKC may give similar or different I values, depending on types of moieties. With known I and Kow for alkylbenzenes as references in MEKC and MEEKC, the values of Kow for disubstituted benzenes can be estimated from the observed I values, where Kow is the octanol–water distribution constant. In addition, a group additive approach can be used to predict I for disubstituted benzenes with different moieties from the average observed I for the disubstituted benzenes with same moieties. However, electronic effects and/or intramolecular interaction may result in the different observed I from prediction.  相似文献   

20.
RH Li  DH Liu  ZH Yang  ZQ Zhou  P Wang 《Electrophoresis》2012,33(14):2176-2183
A novel method based on the combination of microemulsion electrokinetic chromatography (MEEKC) and vortex‐assisted surfactant‐enhanced‐emulsification liquid–liquid microextraction (VSLLME) was developed for the determination of five triazine herbicides (simazine, atrazine, ametryn, prometryn, and terbutryn) in water samples. The five triazine herbicides were baseline separated by using the microemulsion buffer containing a 10 mmol/L borate buffer at pH 9.5, 2.5% (w/v) SDS as surfactant, 0.8% (w/v) ethyl acetate as oil phase, and 6.0% (w/v) 1‐butanol as cosurfactant. The optimum extraction conditions of VSLLME were as follows: 100 μL chloroform was used as extraction solvent, 5.0 × 10?5 mol/L Tween‐20 was chosen as the surfactant to enhance the emulsification, and the extraction process was carried out by vortex mixing for 3 min. Under these optimum experimental conditions, the calibration curve was linear in the range of 2.0–200.0 ng/mL, with the correlation coefficients (r2) varying from 0.9927 to 0.9958. The detection limits of the method varied from 0.41 to 0.62 ng/mL. The purposed method was applied to the determination of five triazine herbicides in real water samples, and the recoveries were between 80.6 and 107.3%.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号