首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Identification of unknown water pollutants with liquid chromatography and tandem mass spectrometry (LC–MS–MS) is often more complex and time consuming than identification with gas chromatography and mass spectrometry (GC–MS). In order to focus the identification effort on relevant compounds, unknown peaks need to be selected carefully. Based on its frequency of occurrence in the LC–Diode Array Detection (LC–DAD) chromatograms of surface and infiltrated waters, an unknown peak was selected for identification with LC–MS–MS. This compound was identified as hexamethoxymethylmelamine (HMMM), a chemical often used in the coating industry. This is the first time the presence of this chemical in surface waters has been reported. In addition to HMMM, two other structurally related compounds were found to be present in the investigated surface water. A standard mixture of HMMM and its by-products did not exhibit (geno)toxicity under the test conditions applied in this study. In another example, a genotoxic fraction of an industrial wastewater was isolated and examined by LC–MS–MS using a modern quadrupole–orthogonal acceleration-time-of-flight mass spectrometer (Q-TOF). Four compounds were detected. The structures of two compounds present are proposed to be 9-amino-2-hydroxy-acridine and 9-hydroxy-acridine-N-oxide or its structural isomer dihydroxy-acridine. Confirmation with standards could not be carried out, as pure compounds are not available. The other two compounds (structural isomers) could not be identified based on the data available within this study.  相似文献   

2.
The characterization of impurities and/or degradants present in pharmaceutical compounds is an important part of the drug development process. Although LC–UV is commonly employed for impurities and degradant compound determination, LC–MS techniques are proposed in this work to be a viable modern alternative for the characterization of these compounds. LC–UV and LC–MS were compared for the detection of impurities present in different brands of trimethoprim tablets by using an in-line LC–UV–MS system with atmospheric pressure chemical ionization source (APCI) coupled with a reversed-phase gradient HPLC system. It was shown that, although chemical noise was higher when using full-scan LC–MS compared to LC–UV, low level impurities were better detected by mass spectrometry (MS) when modern software algorithms are employed. These included the “Contour” chromatogram algorithm and/or the “component detection algorithm” (CODA). In addition, MS allowed for the simultaneous determination of the molecular masses and some structural information of the impurities and/or degradants. The results also showed a large difference in the purity of trimethoprim among different manufacturers. LC–MS and tandem MS techniques were employed to acquire fragmentation patterns for trimethoprim and its degradants to gain insight into their structures.  相似文献   

3.
Leuprolide is a synthetic structural analogue of luteinizing hormone-releasing hormone used for the treatment of a large number of diseases related with the regulation of sexual hormones. Solid-phase peptide synthesis is used to obtain leuprolide peptidic hormone, but this synthetic procedure results in complex mixtures that need separation and characterization. Here, liquid chromatography coupled with mass spectrometry using electrospray ionization, (LC–ES-MS), was used for the separation and characterization of multicomponent peptide mixtures of crudes of synthesis of leuprolide. To optimize the LC separation process, the method of linear solvation energy relationships was applied and the powerful coupling LC–ES-MS permitted rapid and reliable characterization of the reaction product.  相似文献   

4.
In this paper, we investigate the accuracy and precision of the results from diode array detector (DAD) data and mass spectrometry (MS) data as obtained subsequent to chromatographic separations using computer simulations. Special attention was given to simulations of multiple injections from a developing enzymatic reaction. These simulations result in three-way LC–DAD–MS kinetic data; LC–DAD and LC–MS data were also evaluated independently in this investigation. The noise characteristics of the MS detector prevent accurate determination of the individual reaction rate constants by the analysis method. Using the data from the DAD in combination with the MS detector results in improved estimation of the rate constants. The results also indicate that the higher resolving power of the MS information compensates for the lower signal-to-noise ratio in these data, compared to DAD data.  相似文献   

5.
In the past 10 years, liquid chromatography–mass spectrometry (LC–MS) has rapidly matured to become a very powerful and useful analytical tool that is widely applied in many areas of chemistry, pharmaceutical sciences and biochemistry. In this paper, recent instrumental developments in LC–MS-related interfacing, ionization and mass analysis are reviewed from the perspective of the application of LC–MS in high-throughput screening of combinatorial libraries and the related high-throughput quantitative bioanalysis in early drug-discovery studies, such as early adsorption, distribution, metabolism and excretion studies.  相似文献   

6.
Liquid chromatography–mass spectrometry (LC–MS) is a powerful tool for analysis of drugs and their metabolites. We used a column-switching system in combination with atmospheric pressure chemical ionization LC–MS (LC–APCI–MS) for the determination of theophylline and its metabolites in biological samples. The separation was carried out on a reversed-phase column using methanol–20 mM ammonium acetate as a mobile phase at a flow-rate of 1 ml/min in 30 min. In the mass spectrum, the molecular ions of these drugs and metabolites were clearly observed as base peaks. This method is sufficiently sensitive and accurate for the pharmacokinetic studies of these drugs.  相似文献   

7.
Among the various compounds considered as emerging pollutants, alkylphenolic surfactants, steroid sex hormones, and pharmaceuticals are of particular concern, both because of the volume of these substances used and because of their activity as endocrine disruptors or as causative agents of bacterial resistance, as is the case of antibiotics. Today, the technique of choice for analysis of these groups of substances is liquid-chromatography coupled to mass spectrometry (LC–MS) and tandem mass spectrometry (LC–MS–MS). In the last decades, this technique has experienced an impressive progress that has made possible the analysis of many environmental pollutants in a faster, more convenient, and more sensitive way, and, in some cases, the analysis of compounds that could not be determined before. This article reviews the LC–MS and LC–MS–MS methods published so far for the determination of alkylphenolic surfactants, steroid sex hormones and drugs in the aquatic environment. Practical considerations with regards to the analysis of these groups of substances by using different mass spectrometers (single quadrupole, ion trap and triple quadrupole instruments, etc.), interfaces and ionization and monitoring modes, are presented. Sample preparation aspects, with special focus on the application of advanced techniques, such as immunosorbents, restricted access materials and molecular imprinted materials, for extraction/purification of aquatic environmental samples and extracts are also discussed.  相似文献   

8.
A method for analysing carbamates and other relatively polar pesticides by LC–MS–MS with electrospray ionisation has been developed. The method is based on extraction by ultrasonication using a methanolic ammonium acetate–acetic acid buffer. After centrifugation the samples are filtered in Miniprep filter HPLC vials and detected by LC–MS–MS. To compensate for variations in the MS response [13C6]-carbaryl was used as internal standard and matrix-matched pesticide solutions were used as external standards for the quantification. The method has been validated for the matrices apple, avocado, carrot, lettuce, orange, potato and wheat at the spiking levels—0.02; 0.04 and 0.20 mg kg−1. Recoveries were generally in the range 70–120%. Results from participation in three intercomparisons proved the accuracy of the method. As the analytical procedure does not include any concentration or cleanup steps, it is easy and fast to perform, making it applicable for routine analysis in large pesticide monitoring programmes.  相似文献   

9.
The present article aims to develop a new extraction procedure to improve the determination of quinolones in chicken muscle. This new determination method was validated using liquid chromatography–ultraviolet detection (LC–UV) and liquid chromatography–mass spectrometry detection (LC–MS), which has special bearing on stability studies. The results obtained by using the method were compared with the results obtained with a previous methodology. The new extraction procedure presents a sensitivity low enough to determine concentration of these drugs below the permissible maximum residue limits (MRL) in chicken muscle and is less time consuming than the previous methodology.  相似文献   

10.
Azaspiracid poisoning (AZP) is a new human toxic syndrome that is caused by the consumption of shellfish that have been feeding on harmful marine microalgae. A liquid chromatography–mass spectrometry (LC–MS) method has been developed for the determination of the three most prevalent toxins, azaspiracid (AZA1), 8-methylazaspiracid (AZA2) and 22-demethylazaspiracid (AZA3) as well as the isomeric hydroxylated analogues, AZA4 and AZA5. Separation of five azaspiracids was achieved on a C18 column (Luna-2, 150×2 mm, 5 μm) with isocratic elution using acetonitrile–water containing trifluoroacetic acid and ammonium acetate as eluent modifiers. Using an electrospray ionisation (ESI) source with an ion-trap mass spectrometer, the spectra showed the protonated molecules, [M+H]+, with most major product ions due to the sequential loss of two water molecules. A characteristic fragmentation pathway that was observed in each azaspiracid was due to the cleavage of the A-ring at C9–C10 for each toxin. It was possible to select unique ion combinations to distinguish between the isomeric azaspiracids, AZA4 and AZA5. Highly sensitive LC–MS3 analytical methods were compared and the detection limits were 5–40 pg on-column. Linear calibrations were obtained for AZA1 in shellfish in the range 0.05–1.00 μg/ml (r2=0.9974) and good reproducibility was observed with a relative standard deviation (%RSD) of 1.8 for 0.9 μg AZA1/ml (n=5). The %RSD values for the minor toxins, AZA4 and AZA5, using LC–MS3 (A-ring fragmentation) were 12.3 and 8.1 (0.02 μg/ml; n=7), respectively. The selectivity of toxin determination was enhanced using LC–MS–MS with high energy WideBand activation.  相似文献   

11.
It is known that while many elements are considered essential to human health, many others can be toxic. However, because the intake, accumulation, transport, storage and interaction of these different metals and metalloids in nature is strongly influenced by their specific elemental form, complete characterization of the element is essential when assessing its benefits and/or risk. Consequently, interest has grown rapidly in determining oxidation state, chemical ligand association, and complex forms of a many different elements. Elemental speciation, or the analyses that lead to determining the distribution of an element’s particular chemical species in a sample, typically involves the coupling of a separation technique and an element specific detector. A large number of methods have been developed which utilize a multitude of different separation mechanisms and detection instruments. Yet, because of its versatility, robustness, sensitivity and multi-elemental capabilities, the coupling of liquid chromatography to inductively coupled plasma mass spectrometry (LC–ICP–MS) has become one of the most popular techniques for elemental speciation studies. This review focuses on the basic principles of LC–ICP–MS, its historical development and the many ways in which this technique can be applied. Different liquid chromatography separations are discussed as well as the factors that must be considered when coupling each to ICP–MS. Recent applications of LC–ICP–MS to the speciation of environmental, biological and clinical samples are also presented.  相似文献   

12.
A sensitive method for the quantitative analysis of all natural isoprenoid cytokinins in plant material by electrospray single-quadrupole mass spectrometry is presented. A baseline chromatographic separation of 20 non-derivatised naturally occurring cytokinins has been developed. Precise analyses of O-glucoside and ribonucleotide fractions were also performed by the high-performance liquid chromatography–mass spectrometry (HPLC–MS) but run separately from the basic cytokinin metabolites. Using post-column splitting, the flux from narrow-bore (2.1 mm i.d.) reversed-phase liquid chromatography column was simultaneously introduced into the diode array and mass detector. Optimal conditions, including final flow rate, desolvation temperature, desolvation gas flow, capillary and cone voltage for effective ionisation in the electrospray ion source were found. When low cone voltage (20 V) was applied, all studied cytokinins were determined in aqueous methanol as dominant quasi-molecular ions of [M+H]+ with limits of detection ranging between 10 and 50 fmol. For routine analysis a linearity range between 25 (75) fmol and 100 pmol was obtained. Developed liquid chromatography–mass spectrometry (LC–MS) method in selective ion monitoring mode was employed to quantify cytokinin species in tobacco BY-2 suspension culture and poplar leaves (Populus×canadensis Moench, cv Robusta).

Purified plant cell (BY-2) and plant tissue (poplar leaves) extracts were obtained by using two different ion-exchange chromatography steps, in combination with immunoaffinity purification using a broad-spectrum monoclonal anti-cytokinin antibody. The antibody strongly recognises the presence of N6-substituent on purine skeleton and thus does not bind adenine and related compounds. The presence of authentic cytokinins in the extracts quantified by LC–MS was further verified by enzyme-linked immunosorbent assays (ELISAs) with prior LC preparation. The combination of liquid chromatography–single-quadrupole mass spectrometry with immunoaffinity chromatography offers an efficient and elegant method for detection and quantification of cytokinin metabolites.  相似文献   


13.
A systematic study for the optimization and implementation of high-performance capillary electrophoresis (HPCE) in conjunction with negative ion electrospray ionization-quadrupole time of flight-tandem mass spectrometry (ESI-QTOF-MS/MS) for the analysis of complex glycolipids is described. The performance of the capillary electrophoresis (CE) and off-line CE/ESI-QTOF-MS approach has been explored for screening a complex ganglioside mixture from bovine brain. All instrumental and solution parameters demonstrated to require special adjustment and to have the most substantial effect on the CE separation, abundance of product ions produced in a low-energy collision-induced dissociation (CID) process and their detection by MS/MS, when attempting to identify and sequence single ganglioside molecular species from CE eluted fractions. Upon optimization of the experimental parameters, an efficient methodology emerged providing the general basic requirements for combined CE/ESI-MS analysis of this type of complex glycoconjugate.  相似文献   

14.
Capillary electrophoresis (CE) was coupled off-line with matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry (MALDI-TOFMS) for the analysis of proteins and peptides. CE fractions were collected directly on a matrix-coated MALDI target, using a sheath-flow interface. Protein adsorption during CE separations was prevented by coating the capillaries with the physically adsorbed, cationic polymer PolyE-323. The CE/MALDI-MS system was used for the analysis of model proteins and peptides at physiological pH as well as analysis of proteins in tear fluid. Moreover, tryptic on-target digestion of the collected protein fractions, with subsequent MALDI-MS and MS/MS peptide analysis, was demonstrated.  相似文献   

15.
Applications of solid-phase microextraction in food analysis   总被引:21,自引:0,他引:21  
Food analysis is important for the evaluation of the nutritional value and quality of fresh and processed products, and for monitoring food additives and other toxic contaminants. Sample preparation, such as extraction, concentration and isolation of analytes, greatly influences the reliable and accurate analysis of food. Solid-phase microextraction (SPME) is a new sample preparation technique using a fused-silica fiber that is coated on the outside with an appropriate stationary phase. Analyte in the sample is directly extracted to the fiber coating. The SPME technique can be used routinely in combination with gas chromatography (GC), GC–mass spectrometry (GC–MS), high-performance liquid chromatography (HPLC) or LC–MS. Furthermore, another SPME technique known as in-tube SPME has also been developed for combination with LC or LC–MS using an open tubular fused-silica capillary column as an SPME device instead of SPME fiber. These methods using SPME techniques save preparation time, solvent purchase and disposal costs, and can improve the detection limits. This review summarizes the SPME techniques for coupling with various analytical instruments and the applications of these techniques to food analysis.  相似文献   

16.
Efficient and automated purification of new chemical entities/potential drug substances and isolation of minor impurities are important aspects of early drug discovery and development strategies, especially when combinatorial synthesis is applied. LC–MS controlled preparative LC and automated fraction collection have been developed for this purpose. The success of such an approach is greatly determined by the quality of the software controlling the application, the coordination between software and hardware, and the reliability of the hardware. The performance of a commercially-available LC–MS controlled autopurification system was evaluated by fractionating four impurities of buspirone as a model compound, eluting closely to the major component under both acidic and basic mobile-phase conditions. A purification strategy for these four components is proposed.  相似文献   

17.
The applicability of a capillary zone electrophoresis–electrospray ionisation tandem mass spectrometric (CZE–ESI-MS–MS) method for the separation of nine fluoroquinolones was investigated. Method optimisation involved systematic trouble-shooting starting with the type and duration of capillary pre-washing and conditioning, the choice of both the CE run buffer, MS sheath liquid, CE run potential, ESI spray voltage, sheath gas flow-rate, MS capillary voltage and CE capillary and MS capillary temperatures. Another extremely important factor was found to be the degree to which the CE capillary protrudes into the ESI chamber as well as whether or not sheath gas and spray voltage are employed during the CE injection or not. The importance of the latter has, to our knowledge, not been addressed elsewhere. Nine fluoroquinolones have been separated and detected in a single run by this technique.  相似文献   

18.
Analytical methods, based on GC–MS and LC–MS, for the determination of traces of 2,4,4′-trichloro-2′-hydroxydiphenyl ether (triclosan) and biphenylol in urban wastewater and marine sediments were developed. These methods involve the use of diverse analytical techniques, such as solid phase extraction (SPE) and pressurized liquid extraction for sample preparation, and GC–negative chemical ionization MS and LC–electrospray ionization (ESI) MS–MS for identification and quantification. The recoveries of triclosan and biphenylol were 84 and 80% in wastewater and 100 and 73% in sediments, respectively. Detection limits obtained were in the range of ppb and ppt. To prove their applicability to real samples and as part of a more extensive monitoring program, the developed methods were applied to the analysis of wastewater samples, coming from an urban wastewater treatment plant (UWWTP), and of marine sediment samples collected at the outflow of two UWWTPs to the sea. Results obtained reveal the presence of triclosan in all the samples at concentrations that ranged from 0.8 to 37.8 μg/l in wastewater and from 0.27 to 130.7 μg/kg in sediments. These preliminary data reinforce the interest for further research on this topic.  相似文献   

19.
A HPLC method for the analysis of polycyclic aromatic nitrogen heterocyclics (PANHs) in complex sample matrices is presented. It isolated and separated carbazole and acridine type PANHs with an absolute recovery of between 79–98%. Open column chromatography is used as an initial step to isolate a PANH fraction. By applying normal-phase liquid chromatography using a dimethylaminopropyl silica stationary phase and utilising back-flush technique it was possible to separate the PANH fraction into two fractions containing acridine type and carbazole type PANHs, respectively. The method applied on a sample of solvent refined coal heavy distillate (SRC II HD). A number of 3–5 ring acridines and carbazoles were identified with GC–electron impact MS and quantified with GC–nitrogen–phosphorous detection. Polycyclic aromatic hydrocarbons (PAHs) were determined in the SRC II HD sample by automated on-line clean-up and analysis of the obtained PAH fraction with coupled LC–GC–flame ionization detection. There was no overlap between the PANH and the PAH fractions with this method, and carbazoles and acridines were efficiently separated.  相似文献   

20.
Current methods for quantitative determination of chlormequat residues in food crops are characterized by rather low recoveries and the need for derivatization (in case of gas chromatography, GC), or by high capital investment (in case of liquid chromatography–mass spectrometry, LC–MS). We propose a cation-exchange chromatography method for the analysis of chlormequat in pears. The method is based on extraction of the target compound with 40 mM HCl, followed by centrifugation and filtration. The filtrate is directly injected into an ion chromatograph equipped with a commercially available cation-exchange column and a suppressed conductivity detection system. While the limit of detection (LOD) (0.5 mg/kg) may not be small enough to allow dietary analysis, the method meets all validation requirements and is an alternative for the existing GC and LC–MS methods in quality control.  相似文献   