首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 93 毫秒
1.
In this work, an improved preconcentration method named as rapidly synergistic cloud point extraction (RS-CPE) was established for copper preconcentration and determination. Non-ionic surfactant Triton X-100 (TX-100) was used as extractant. Octanol worked as cloud point revulsant and synergic reagent, which successfully decreased the cloud point temperature (CPT) of TX-100 to realize the room temperature (about 20°C) CPE without heating. The established RS-CPE pretreatment was simple, rapid and effective. Compared with traditional CPE (about 40 min for heating, incubation and cooling), the extraction time of the proposed method was very short (1 min). The improved extraction technique RS-CPE was combined with traditional spectrophotometer to improve the analytical performance and expand the application of spectrophotometric determination. The influence factors relevant to RS-CPE, such as concentrations of TX-100 and octanol, concentration of chelating agent, pH, conditions of phase separation, salt effect, environmental temperature and instrumental conditions, were studied in detail. Under the optimal conditions, the limit of detection (LOD) for copper was 0.4 μg L(-1), with sensitivity enhancement factor (EF) of 18. The proposed method was applied to the determination of trace copper in real samples and certified samples with satisfactory analytical results.  相似文献   

2.
A method for the preconcentration of Cu(II) by cloud point extraction (CPE) followed by its determination using neutron activation analysis (NAA) was developed. The method involves the use of a nonionic surfactant, namely PONPE-7.5, and a chelating agent 1-(2-pyridylazo)-2-naphthol (PAN). The phase diagram of the surfactant was constructed and the effects of different additives on the cloud point were investigated. Factors, such as the solution pH, ionic strength, temperature, and concentrations of chelating agent and surfactant, which can influence the extraction efficiency of the metal, were optimized. The copper(II) chelate was extracted into a surfactant-rich phase of small volume with a recovery of nearly 100% and a preconcentration factor of 60. The small volume of the surfactant-rich phase obtained complies with the green chemistry concept, allowing the design of extraction procedures having lower toxicity than those using organic solvents. The method was applied to tap water samples.  相似文献   

3.
以8-羟基喹啉(8-HQ)为螯合剂,在pH 9缓冲溶液中,痕量铅(Ⅱ)与8-HQ生成螯合物,加入表面活性剂Triton X-100用浊点萃取分离富集样品中痕量铅。分取部分表面活性剂相用0.1mol·L-1硝酸溶液定容至2mL,所得溶液直接用石墨炉原子吸收光谱法进行测定。对影响浊点萃取的因素和共存离子的干扰等进行了试验并予以优化。方法的检出限(3σ)为0.85pg。应用所提出的方法测定了膨化食品样品中铅的含量,在5种样品中用标准加入法进行方法的回收试验,测得回收率在91.7%~101.7%之间。  相似文献   

4.
《Analytical letters》2012,45(9):1853-1864
Abstract

A new method based on the cloud point extraction (CPE) separation and ultraviolet spectrometry determination was proposed for the determination of albumin. When the system temperature is higher than the cloud point extraction temperature (CPT) of the mixed surfactant of p‐octyl polyethyleneglycolphenyether (Triton X‐100) and sodium dodecyl sulfate (SDS), serum albumin could be extracted into surfactant‐rich phase. The main factors affecting the cloud point extraction were investigated systematically. Under the optimized conditions, the determination limit for serum albumin as low as 0.18 µg/mL was obtained by preconcentrating a 10 mL sample solution, and the relative standard deviation (n=10, c=40.0 µg/mL) was 3.77%. The proposed method was applied to the determination of albumin in serum samples. The results obtained by this method were in good agreement with coomassie brilliant blue (CBB).  相似文献   

5.
浊点萃取-氢化物发生原子吸收光谱法测痕量汞   总被引:2,自引:0,他引:2  
提出了浊点萃取预富集氢化物发生-原子吸收光谱法测定痕量汞的新方法。详细探讨了溶液pH值、表面活性剂浓度、平衡时间等因素对浊点萃取效果的影响。在优化的实验条件下,该法对汞的富集倍数为20倍,检出限为0.039μg/L,相对标准偏差(RSD)为4.8%(n=11)。所建立的方法用于天然水中痕量汞的测定,分析结果满意。  相似文献   

6.
Natural antioxidants derived from plant sources attract considerable scientific interest. While classic extraction methods consume high volumes of toxic organic solvents, cloud point extraction requires surfactant not exceeding 15% of the waste volume. In preliminary tests, the suitability of various low hazard surfactants (Span 20, PEG 400, Tween 80 and 20) was explored for separation of phenols and carotenoids from olive mill wastewater and red‐flesh orange juice. Tween 80 showed the highest recovery and further applied to the next experiments. The most appropriate surfactant concentrations were 5% (for olive mill wastewater) and 7% (for orange juice) as indicated by recovery % and the rest cloud point extraction parameters (analyte concentration, concentration factor, and phase volume ratio). A double step CPE with 5% + 5% of Tween 80 recovered up to 94.4% of the total phenols from olive mill wastewater, while a 7% + 7% of Tween 80 recovered up to 72.4% of the total carotenoids from orange juice. Evaluation of the final effects and extraction efficiency of single and double step cloud point extraction shows that double step scheme seems to be preferable in both cases. Finally, phenols and carotenoids recovered by Tween 80 maintained high antiradical activity (DPPH test).  相似文献   

7.
浊点萃取-火焰原子吸收光谱法测定菠菜中镁、锌和铜   总被引:1,自引:0,他引:1  
在pH 8.0缓冲溶液中,以8-羟基喹啉为螯合剂,镁、锌和铜均与8-羟基喹啉生成螯合物,加入Triton X-100表面活性剂用浊点萃取分离富集菠菜样品中镁、锌和铜。分取部分表面活性剂相用乙醇定容至25mL,所得溶液直接用火焰原子吸收光谱法进行测定。对影响浊点萃取的因素和共存离子的干扰等进行了试验并予以优化。镁、锌和铜的检出限(3s/k)依次为0.057,0.064,0.032mg.L-1。应用此法测定了大叶菠菜和小叶菠菜中3种元素的含量,在两种样品中用标准加入法进行方法的回收试验,测得镁的回收率在93.3%~100.5%之间;锌的回收率在91.7%~97.9%之间;铜的回收率在94.0%~107.1%之间。  相似文献   

8.
In this work, traditional cloud point extraction (CPE) pattern was changed and improved by the proposed rapidly synergistic CPE. Using octanol as cloud point revulsant and synergic reagent, non-ionic surfactant Triton X-114 (TX-114) accomplished room temperature extraction rapidly without heating in water bath. The improved extraction was named as rapidly synergistic cloud point extraction (RS-CPE). Compared with traditional CPE, RS-CPE was accomplished in 1 min with considerably high extraction efficiency. The improved CPE pattern was coupled with flame atomic absorption spectrometry (FAAS) for the extraction and detection of trace lead in real and certified water samples with satisfactory analytical results. The proposed method greatly improved the sensitivity of FAAS for the determination of lead. Under the optimal conditions, the limit of detection (LOD) for lead was 4.3 μg/L, with enhancement factor (EF) of 39. Factors influencing RS-CPE efficiency, such as concentrations of surfactant TX-114 and octanol, concentration of chelating agent, pH, conditions of phase separation, environmental temperature, salt effect and instrumental conditions, were studied systematically.  相似文献   

9.
研究了以双硫腙为络合剂,以非离子型表面活性剂Triton X-100为萃取剂的浊点萃取-火焰原子吸收光谱法(CPE-FAAS)测定痕量金(Ⅲ)的新方法。详细考察了溶液的pH值、络合剂和表面活性剂浓度、平衡温度和时间等条件对浊点萃取效果的影响。该方法的线性范围为0.05~0.8μg/mL,检出限为7.9 ng/mL,相对标准偏差为4.12%(n=11),回收率在98.0%~102.0%之间,用于矿渣中金的测定,结果满意。  相似文献   

10.
浊点萃取-火焰原子吸收光谱法测定样品中的痕量钴   总被引:3,自引:0,他引:3  
研究了基于表面活性剂Triton X-114和络合剂吡咯烷二硫代氨基甲酸铵(APDC)浊点萃取钴的样品前处理方法.优化了浊点萃取条件参数,包括pH值、Triton X-114用量、APDC浓度、平衡温度及时间等,建立了浊点萃取-火焰原子吸收光谱法测定痕量钴的方法.该法的检测限(3σ)为2.6μg/L,相对标准偏差RSD为6.2%(n=7,c=200μg/L).该法成功地应用于海带、维生素B12注射液等样品中钴的测定.  相似文献   

11.
Saitoh T  Hinze WL 《Talanta》1995,42(1):119-127
The feasibility of utilizing a zwitterionic surfactant, 3-(nonyldimethylammonio)propylsulfate, or nonionic surfactant, Triton X-114, mediated phase separation in conjunction with affinity ligands was studied for hydrophilic protein extractions. Below (or above) its critical temperature (so-called cloud point), aqueous solutions of zwitterionic (or nonionic) surfactants separate into two immiscible phases, a surfactant-rich phase and an aqueous phase. Avidin was successfully extracted into the zwitterionic surfactant-rich phase when a small amount of the affinity ligand, N- biotinoyl)dipalmitoyl- l -alpha- phosphatidyl ethanolamine, was added to the system. It was not possible to extract hexokinase into the surfactant-rich phase of the nonionic surfactant, Triton X-114, even if a considerable amount of octyl-beta-d-glucoside was added to the solution as an affinity ligand. In contrast, the use of the zwitterionic surfactant and octyl-beta-d-glucoside as an affinity ligand proved to be effective for the extraction of hexokinase. The hexokinase extraction efficiency was found to depend upon the solution pH and the concentration of the affinity ligand in the system. The results clearly indicate that hydrophilic proteins can be successfully extracted with surfactant mediated phase separations (cloud point extractions) via use of the zwitterionic surfactant, 3-(nonyldimethylammonio)propylsulfate, and appropriate affinity ligands. Some advantages of zwitterionic surfactants in such extractive processes relative to that of nonionic surfactants are delineated.  相似文献   

12.
The cloud point technique was used to recover phenol, 4-methylphenol, and 4-nitrophenol from aqueous solutions using oxyethylated methyl dodecanoates as nonionic surfactants. Oxyethylated methyl dodecanoates are convenient nonionic surfactants for such separations. Their cloud points can be easily modified by a change in surfactant hydrophilicity or by the addition of a second nonionic surfactant and/or an electrolyte. The use of the hydrophile lipophile balance is preferred to model the cloud point of oxyethylated methyl dodecanoates and their mixtures with other surfactants. The composition of the surfactant-rich phase depends on electrolyte type and the overheating. The phase can contain only 5-15% of water. Recovery of phenols changes in the order 4-nitrophenol >4-methylphenol > phenol and is increased in the presence of sodium chloride. The presence of salting-out electrolytes is preferred both to decrease the cloud point and to increase the efficiency of extraction.  相似文献   

13.
研究了基于非离子表面活性剂TritonX-114和螯合剂二乙基氨基二硫代甲酸钠(DDTC)的浊点萃取-火焰原子吸收光谱法测定痕量铜的分析方法.考察了影响浊点萃取效率的参数,包括pH值、DDTC浓度、TritonX-114用量、平衡温度及时间等.在优化条件下,本法的检出限(3σ)为1.55μg/L,相对标准偏差RSD为3.4%(n=7,c=100μg/L),线性范围为0~250μg/L.将该法应用于茶叶标准样品(GBW07605)、奶粉和矿泉水等样品中痕量铜的测定,其回收率在96.7%~113.5%之间.  相似文献   

14.
建立了以四甲基联苯胺(TMB)为络合剂,非离子表面活性剂Triton-114为萃取剂的浊点萃取-紫外可见分光光度法测定痕量金的方法。考察了溶液的pH、络合剂和表面活性剂浓度、平衡温度和时间等条件对浊点萃取的影响。在最优条件下,该方法对金的富集倍数为12倍,线性范围为0~0.5μg/mL,检出限(3σ)为8.6ng/mL,相对标准偏差RSD为2.3%~3.6%(n=6),回收率在97%~102%之间。方法已用于工业废水中痕量金的测定。  相似文献   

15.
A cold column trapping-cloud point extraction (CCT-CPE) method coupled to high performance liquid chromatography (HPLC) was developed for preconcentration and determination of curcumin in human urine. A nonionic surfactant, Triton X-100, was used as the extraction medium. In the proposed method, a low surfactant concentration of 0.4% v/v and a short heating time of only 2 min at 70 °C were sufficient for quantitative extraction of the analyte. For the separation of the extraction phase, the resulted cloudy solution was passed through a packed trapping column that was cooled to 0 °C. The temperature of the CCT column was then increased to 25 °C and the surfactant rich phase was desorbed with 400 μL ethanol to be directly injected into HPLC for the analysis. The effects of different variables such as pH, surfactant concentration, cloud point temperature and time were investigated and optimum conditions were established by a central composite design (response surface) method. A limit of detection of 0.066 mg L−1 curcumin and a linear range of 0.22–100 mg L−1 with a determination coefficient of 0.9998 were obtained for the method. The average recovery and relative standard deviation for six replicated analysis were 101.0% and 2.77%, respectively. The CCT-CPE technique was faster than a conventional CPE method requiring a lower concentration of the surfactant and lower temperatures with no need for the centrifugation. The proposed method was successfully applied to the analysis of curcumin in human urine samples.  相似文献   

16.
A fast, simple, inexpensive and effective method is developed for spectrophotometric determination of Aspirin in commercial tablets based on micro-cloud point extraction (MCPE). The proposed MCPE is essentially a miniaturized form of traditional cloud point extraction (CPE) in which only a few microliters of micellar extracting phase is sufficient for spectrophotometric determination. For comparison with MCPE, cloud point extraction was examined for Aspirin extraction. Triton X-114 was employed as a non-ionic surfactant for extraction/preconcentration of aspirin. Factors influencing the extraction efficiency, such as concentration of Triton, effect of pH, type of dilution solvent, etc. were investigated and optimized. Under the optimized condition, linear calibration curve for MCPE was in the range of 0.05–2 mg/L and limit of detection of 0.05 mg/L was obtained, whereas linear part for CPE calibration curve was 0.9 to 11 mg/L with a limit of detection of 0.5 mg/L.  相似文献   

17.
In the presented work, the conditions for cloud point extraction of iron from aqueous solutions using 7-iodo-8-hydroxyquinolin-5-sulphonic acid (Ferron) was investigated and optimized. The procedure is based on the separation of its ferron complex into the micellar media by adding the surfactant Triton X-114. After phase separation, the surfactant-rich phase was dissolved with 1.0 M HNO3 in methanol. Iron was determined by flame atomic absorption spectrometry. Optimization of the pH, ligand and surfactant quantities, incubation time, temperature, viscosity, sample volume, and interfering ions were investigated. The effects of the matrix ions were also examined. The detection limits for three times the standard deviations of the blank for iron was 0.4 ng m L-1, enrichment factor of 19.6 and preconcentration factor of 30 could be achieved. The validity of cloud point extraction was checked by employing real samples including soil, blood, spinach, milk, meat, liver and orange juice samples using the standard addition method, which gave satisfactory results.In the presented work, the conditions for cloud point extraction of iron from aqueous solutions using 7-iodo-8-hydroxyquinolin-5-sulphonic acid (Ferron) was investigated and optimized. The procedure is based on the separation of its ferron complex into the micellar media by adding the surfactant Triton X-114. After phase separation, the surfactant-rich phase was dissolved with 1.0 M HNO3 in methanol. Iron was determined by flame atomic absorption spectrometry. Optimization of the pH, ligand and surfactant quantities, incubation time, temperature, viscosity, sample volume, and interfering ions were investigated. The effects of the matrix ions were also examined. The detection limits for three times the standard deviations of the blank for iron was 0.4 ng m L−1, enrichment factor of 19.6 and preconcentration factor of 30 could be achieved. The validity of cloud point extraction was checked by employing real samples including soil, blood, spinach, milk, meat, liver and orange juice samples using the standard addition method, which gave satisfactory results.   相似文献   

18.
The cloud point extraction procedure is an alternative to liquid–liquid extraction and based on the phase separation that occurs in aqueous solutions of non-ionic surfactants when heated above the so-called cloud point temperature. We review the more recent applications for determination of ions by means of this procedure for sample preparation over the range 2009 to first part of 2011. Following an introduction, the article covers aspects of cloud point extraction of one metal ion, two metals ions simultaneously, three metal ions simultaneously, multielement analysis, anions analysis, and on-line cloud point extraction. One hundred sixteen references are cited.
Figure
Scheme of the CPE procedure. CPE techniques exploit a property of most non-ionic surfactants that form micelles in aqueous solution: they become turbid when heated to the appropriate cloud point temperature. Above the cloud point temperature, the micellar solution separates into a small, surfactant rich phase and a larger diluted aqueous phase  相似文献   

19.
Orthogonal array design (OAD) was applied for the first time to optimize cloud point extraction (CPE) conditions for Se(IV) determination by electrothermal atomic absorption spectrometry (ETAAS) in environmental and biological samples. Selenium was reacted with o-phenylenediamine to form piazselenol in an acidic medium (pH 2). Using Triton X-114, as surfactant, piazselenol was quantitatively extracted into small volume (about 30 μL) of the surfactant-rich phase after centrifugation. Five relevant factors, i.e. surfactant concentration, pH, ionic strength, equilibrium time and temperature were selected and the effects of each factor were studied at four levels on the extraction efficiency of Se(IV) and optimized. The statistical analysis revealed that the most important factors contributing to the extraction efficiency are ionic strength, pH and percent of surfactant. Based on the results obtained from the analysis of variance (ANOVA), the optimum conditions for extraction were established as: pH 6; vial temperature = 50 °C; extraction time = 7 min and 0.3% (w/v) of Triton X-114. The method was permitted to obtain a detection limit of 0.09 ng mL−1 and two linear calibration ranges from 0.6 to 1.0 and 1.0 to 80.0 ng mL−1 Se. The precision (%RSD) of the extraction and determination for the six replicates of Se at 20 ng mL−1 was better than 3.6% and the enrichment factor of 63.5 was achieved. The studied analyte was successfully extracted and determined with high efficiency using cloud point extraction method in water and biological matrices.  相似文献   

20.
A novel cloud point phase separation of cationic surfactant, Aliquat-336 and capabilities of its reactive solubilizing sites for selective extraction of chromium species at ultra trace levels was examined in natural water. The phase separation behavior of Aliquat-336 is studied with various additives. The nonionic surfactant, Triton X-114 was found to induce the cloud point phase separation of Aliquat-336. The separation of anionic Cr(VI) was enabled by the formation of ion associate with quaternary ammonium head group of Aliquat-336 at pH 2, and the recovery of Cr(VI) and Cr(III) were 101.4 ± 1.4% and 2.2 ± 0.4%, respectively at 0.5-1 ng mL−1, Total Cr was pre-concentrated as Cr-APDC species using the hydrophobic tail group at pH 6.5. The Cr(III) concentration was obtained by subtracting Cr(VI) from total Cr. The recovery of total Cr was 99.5 ± 1.2%. Parameters affecting extraction were assessed. The procedure was applied to NIST 1643c and NIST 1643d waters, and the sum of individual species obtained was compared with the certified chromium values. The method was also applied to various natural waters with limits of detection and pre-concentration factor of 0.010 and 0.025 ng mL−1; 10 and 10, respectively, for Cr(VI) and Cr(III)-APDC using ICP-MS operated in DRC mode.  相似文献   