首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
In this paper, a novel electro-active graphene oxide (GO) nanocomposite was firstly prepared by covalently grafted (4-ferrocenylethyne) phenylamine (Fc-NH2) onto the surface of GO. The synthesized hybridized nanocomposite of GO-Fc-NH2 coupled with HAuCl4 simultaneously electrodeposited on the glassy carbon electrodes (GCE) to obtain rGO-Fc-NH2/AuNPs/GCE. The covalently grafted material of the rGO-Fc-NH2/AuNPs film can effectively prevent the electron mediator leaking from the electrode surface, which can hold the advantage of both the nanomaterials and electron mediator. By employing the catalysis effect of the nanomaterial and electron mediator coupling with large active surface area and high accumulation capacity of rGO-Fc-NH2/AuNPs, a synergetic signal amplification platform for ultra-sensitive detection of bisphenol A (BPA) was successfully established. With this novel sensor, the oxidation peak currents of BPA were linearly dependent on the BPA concentrations in the range of 0.005–10 μM with the detection limit of 2 nM. Modification of electron mediators on nanomaterials can greatly enhance the electrochemical performance of the sensors and will provide a new concept for fabricating newly electro-active nanomaterials-based electrochemical biosensors.  相似文献   

2.
Recent progress in flexible and lightweight electrochemical sensor systems requires the development of paper-like electrode materials. Here, we report a facile and green synthesis of a new type of MnO2 nanowires–graphene nanohybrid paper by one-step electrochemical method. This strategy demonstrates a collection of unique features including the effective electrochemical reduction of graphene oxide (GO) paper and the high loading of MnO2 nanowires on electrochemical reduced GO (ERGO) paper. When used as flexible electrode for nonenzymatic detection of hydrogen peroxide (H2O2), MnO2–ERGO paper exhibits high electrocatalytic activity toward the redox of H2O2 as well as excellent stability, selectivity and reproducibility. The amperometric responses are linearly proportional to H2O2 concentration in the range 0.1–45.4 mM, with a detection limit of 10 μM (S/N = 3) and detection sensitivity of 59.0 μA cm−2 mM−1. These outstanding sensing performances enable the practical application of MnO2–ERGO paper electrode for the real-time tracking H2O2 secretion by live cells macrophages. Therefore, the proposed graphene-based nanohybrid paper electrode with intrinsic flexibility, tailorable shapes and adjustable properties can contribute to the full realization of high-performance flexible electrode material used in point-of-care testing devices and portable instruments for in-vivo clinical diagnostics and on-site environmental monitoring.  相似文献   

3.
Han J  Zhuo Y  Chai YQ  Mao L  Yuan YL  Yuan R 《Talanta》2011,85(1):130-135
A new label-free amperometric immunosensor was developed for detection of carcinoembryonic antigen (CEA) based on chitosan-ferrocene (CS-Fc) and nano-TiO2 (CS-Fc + TiO2) complex film and gold nanoparticles-graphene (Au-Gra) nanohybrid. CS-Fc + TiO2 composite membrane was first modified on a bare glass carbon electrode. Then Au-Gra nanohybrid was formed on the CS-Fc + TiO2 membrane by self-assembly strategy. Next, further immobilization of anti-CEA was constructed according to the strong interaction between Au-Gra and the amido groups of anti-CEA. Since Au-Gra nanohybrid films provided a congenial microenvironment for the immobilization of biomolecules, the surface coverage of antibody protein could be enhanced and the sensitivity of the immunosensor has been improved. The good electronic conductive characteristic might be attributed to the synergistic effect of graphene nanosheets and Au NPs. The modified process was characterized by scanning electron microscope (SEM) and cyclic voltammetry (CV). Under optimized conditions, the resulting biosensor displayed good amperometric response to CEA with linear range from 0.01 to 80 ng/mL and a detection limit of 3.4 pg/mL (signal/noise = 3). The results demonstrated that the immunosensor has advantages of high conduction, sensitivity, and long life time. This assay approach showed a great potential in clinical applications and detection of low level proteins.  相似文献   

4.
Hydrophobic silver and titanium (IV) oxide nanoparticles (commercial Ag and TiO2 NPs with average particle sizes of 17 and 19 nm, respectively) were quantitatively transferred into organic phase in natural water samples. Five NP surface modification and solvent extraction agents (reagents) types, mercaptocarboxylic acid, alkylamine, mediator solvent, extraction solvent, and surfactant, were investigated and optimized with three-level orthogonal array design (OAD), an OA27 (313) matrix. The most favorable reagents and experimental conditions were then examined. The best extraction efficiencies of 78.6 and 73.7% were obtained for 1 mg L−1 citrate-stabilized Ag and TiO2 NPs, respectively, with 0.5 mM of 11-mercaptoundecanoic acid, 1.5 mM of octadecylamine, 1 mL of methanol, 150 μL of cyclohexane, 0.05 mM of tetra-n-octylammonium bromide, pH = 8.0, adsorption time of 2 h, sonication time of 3 min, and centrifugation time of 10 min. Enrichment factors were 97 and 83, for Ag and TiO2 NPs, respectively. The optimum extraction conditions were successfully applied to genuine water samples at spiking levels of 2–100 μg L−1 of Ag and TiO2 NPs. The relative recoveries of (69.0–85.1)% and (61.5–78.5)% were obtained for Ag and TiO2 NPs, respectively. The extracted surface-modified NPs were characterized with transmission electron microscopy, selected area electron diffraction, energy-dispersive X-ray, ultraviolet–visible, and Fourier transform infrared spectroscopic techniques. Based on the results, efficient ligand exchange and acid–base pair formation were observed on the NP surface without significant change in its original properties. The organic phase was microwave digested, and analyzed with inductively coupled plasma (ICP) optical emission spectroscopy and ICP mass spectrometry (ICP-MS). Detection limits of ICP-MS analyses of Ag and TiO2 NPs were 0.02 and 0.07 μg L−1, respectively.  相似文献   

5.
We proposed an electrochemical DNA sensor by using peroxidase-like magnetic ZnFe2O4–graphene quantum dots (ZnFe2O4/GQDs) nanohybrid as a mimic enzymatic label. Aminated graphene and Pd nanowires were successively modified on glassy carbon electrode, which improved the electronic transfer rate as well as increased the amount of immobilized capture ssDNA (S1). The nanohybrid ZnFe2O4/GQDs was prepared by assembling the GQDs on the surface of ZnFe2O4 through a photo-Fenton reaction, which was not only used as a mimic enzyme but also as a carrier to label complementary ssDNA (S3). By synergistically integrating highly catalytically activity of nano-sized GQDs and ZnFe2O4, the nanohybrid possessed highly-efficient peroxidase-like catalytic activity which could produce a large current toward the reduction of H2O2 for signal amplification. Thionine was used as an excellent electron mediator. Compared with traditional enzyme labels, the mimic enzyme ZnFe2O4/GQDs exhibited many advantages such as environment friendly and better stability. Under the optimal conditions, the approach provided a wide linear range from 10−16 to 5 × 10−9 M and low detection limit of 6.2 × 10−17 M. The remarkable high catalytic capability could allow the nanohybrid to replace conventional peroxidase-based assay systems. The new, robust and convenient assay systems can be widely utilized for the identification of other target molecules.  相似文献   

6.
Bisphenol A (BPA), which could disrupt endocrine system and cause cancer, has been considered as an endocrine disruptor. Therefore, it is very important and necessary to develop a sensitive and selective method for detection of BPA. Herein, nitrogen-doped graphene sheets (N-GS) and chitosan (CS) were used to prepare electrochemical BPA sensor. Compared with graphene, N-GS has favorable electron transfer ability and electrocatalytic property, which could enhance the response signal towards BPA. CS also exhibits excellent film forming ability and improves the electrochemical behavior of N-GS modified electrode. The sensor exhibits a sensitive response to BPA in the range of 1.0 × 10−8–1.3 × 10−6 mol L−1 with a low detection limit of 5.0 × 10−9 mol L−1 under the optimal conditions. Finally, this proposed sensor was successfully employed to determine BPA in water samples with satisfactory results.  相似文献   

7.
The present paper has focused on the potential application of the bifunctional polydopamine@Fe3O4 core–shell nanoparticles for development of a simple, stable and highly selective electrochemical method for metal ions monitoring in real samples. The electrochemical method is based on electrochemical preconcentration/reduction of metal ions onto a polydopamine@Fe3O4 modified magnetic glassy carbon electrode at −1.1 V (versus SCE) in 0.1 M pH 5.0 acetate solution containing Pb2+ and Cd2+ during 160 s, followed by subsequent anodic stripping. The proposed method has been demonstrated highly selective and sensitive detection of Pb2+ and Cd2+, with the calculated detection limits of 1.4 × 10−11 M and 9.2 × 10−11 M. Under the optimized conditions, the square wave anodic stripping voltammetry response of the modified electrode to Pb2+ (or Cd2+) shows a linear concentration range of 5.0–600 nM (or 20–590 nM) with a correlation coefficient of 0.997 (or 0.994). Further, the proposed method has been performed to successfully detect Pb2+ and Cd2+ in aqueous effluent.  相似文献   

8.
This article reports on carbon nanotube/manganese dioxide (CNT–MnO2) composites as electrochemical tags for non-enzymatic signal amplification in immunosensing. The synthesized CNT–MnO2 composites showed good electrochemical activity, electrical conductivity and stability. The electrochemical signal of CNT–MnO2 composites coated glassy carbon electrode (GCE) increased by nearly two orders of magnitude compared to bare GCE in hydrogen peroxide (H2O2) environment. CNT–MnO2 composite was subsequently validated as electrochemical tags for sensitive detection of α-fetoprotein (AFP), a tumor marker for diagnosing hepatocellular carcinoma. The electrochemical immunosensor demonstrated a linear response on a log-scale for AFP concentrations ranging from 0.2 to 100 ng mL−1. The limit of detection (LOD) was estimated to be 40 pg mL−1 (S/N = 3) in PBS buffer. Further measurements using AFP spiked plasma samples revealed the applicability of fabricated CNT–MnO2 composites for clinical and diagnostic applications.  相似文献   

9.
In this paper, the reduced graphene oxide and multiwall carbon nanotubes hybrid materials (RGO–MWNTs) were prepared and a strategy for detecting environmental contaminations was proposed on the basis of RGO–MWNTs modified electrode. The hybrid materials were characterized by the scanning electron microscopy (SEM), atomic force microscopy (AFM), X-ray photoelectron spectroscopy (XPS) and N2 sorption–desorption isotherms. Due to the excellent catalytic activity, enhanced electrical conductivity and high surface area of the RGO–MWNTs, the simultaneous measurement of hydroquinone (HQ), catechol (CC), p-cresol (PC) and nitrite (NO2) with four well-separate peaks was achieved at the RGO–MWNTs modified electrode. The linear response ranges for HQ, CC, PC and NO2 were 8.0–391.0 μM, 5.5–540.0 μM, 5.0–430.0 μM and 75.0–6060.0 μM, correspondingly, and the detection limits (S/N = 3) were 2.6 μM, 1.8 μM, 1.6 μM and 25.0 μM, respectively. The outstanding film forming ability of RGO–MWNTs hybrid materials endowed the modified electrode enhanced stability. Furthermore, the fabricated sensor was applied for the simultaneous determination of HQ, CC, PC and NO2 in the river water sample.  相似文献   

10.
We have demonstrated a facile approach for fabricating graphene quantum dots–TiO2 (GQDs–TiO2) nanocomposites by a simple physical adsorption method. Compared with pure GQDs and TiO2 nanoparticles (NPs), the as-prepared GQDs–TiO2 nanocomposites showed enhanced photoelectrochemical (PEC) signal under visible-light irradiation. The photocurrent of GQDs–TiO2/GCE was nearly 30-fold and 12-fold enhancement than that of GQDs/GCE and TiO2/GCE, respectively, which was attributed to the synergistic amplification between TiO2 NPs and GQDs. More interestingly, the photocurrent of GQDs–TiO2 nanocomposites was selectively sensitized by dopamine (DA), and enhanced with the increasing of DA concentration. Further, a new PEC methodology for ultrasensitive determination of DA was developed, which showed linearly enhanced photocurrent by increasing the DA concentration from 0.02 to 105 μM with a detection limit of 6.7 nM (S/N = 3) under optimized conditions. This strategy opens up a new avenue for the application of GQDs-based nanocomposites in the field of PEC sensing and monitoring.  相似文献   

11.
A novel ceria (CeO2)–ordered mesoporous carbon (OMC) modified electrode for the sensitive amperometric determination of hydrazine was reported. CeO2–OMC composites were synthesized via a hydrothermal method at a relatively low temperature (180 °C) and characterized by scanning electron microscopy (SEM), transmission electron microcopy (TEM), X-ray photoelectron spectroscopy (XPS) and X-ray diffraction (XRD). The CeO2–OMC modified glassy carbon electrode was characterized by electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV) and indicated good electrocatalytic effect to the oxidation of hydrazine. Under the optimized conditions, the present sensor could be used to measure hydrazine in wide linear range from 40 nM to 192 μM (R2 = 0.999) with a low detection limit of 12 nM (S/N = 3). Additionally, the sensor has been successfully applied to detect hydrazine in real water samples and the recoveries were between 98.2% and 105.6%. Eventually, the sensor exhibited an excellent stability and reproducibility as a promising method for determination of hydrazine.  相似文献   

12.
A novel 8-electrode array as stir bar was designed for selective extraction of trace level exogenous estrogens from food samples, followed by liquid desorption and HPLC-photodiode array detection. The array consisted of 8 screen-printed electrodes and each electrode was modified with Fe3O4@meso-/macroporous TiO2 microspheres and molecularly imprinted film (m-TiMIF). The fabrication of the imprinted film coating was very simple without organic solvents and chemical grafting. Both bisphenol A (BPA) and diethylstilbestrol (DES) were employed as templates in m-TiMIF fabrication in order to enrich both targets simultaneously. Interestingly, the imprinted stir bar array showed higher extraction capacity and selectivity for BPA and DES than the non-imprinted counterpart. Meanwhile, it exhibited fast adsorption and desorption kinetics due to increased mass transport in the ultra-thin film. Importantly, the m-TiMIF coating was robust enough for at least 20 uses without obvious alteration in extraction performance. The main parameters affecting the extraction efficiency, including stir speeding, sample pH, ionic strength, extraction time, desorption solvent and time, were optimized. Under optimal experimental conditions, the limits of detection (S/N = 3) of the developed method were 0.28 and 0.47 μg L−1 for BPA and DES respectively, with enrichment factors of 32.6 and 52.8-fold. The linear ranges were 3.0–1500 μg L−1 and 4.0–1500 μg L−1 for BPA and DES, respectively. The m-TiMIF-coating conferred better recovery and selectivity, compared with the commercial stir bar coating. The new method was successfully applied to assess BPA and DES in pork and chicken samples with satisfactory recovery.  相似文献   

13.
The combination of coumarin derivative (7-(1,3-dithiolan-2-yl)-9,10-dihydroxy-6H-benzofuro[3,2-c]chromen-6-on), (DC)–titanium dioxide nanoparticles (TiO2) and ionic liquid (IL) yields nanostructured electrochemical sensor, formed a novel kind of structurally uniform and electrocatalytic activity material. This new ionic liquid–TiO2 nanoparticles modified carbon paste electrode (IL–CTP) due to its enhanced conductivity presented very large current response from electroactive substrates. The modified electrode was characterized by different methods including a scanning electron microscope (SEM), electrochemical impedance spectroscopy (EIS) and voltammetry. A pair of well-defined quasi reversible redox peaks of coumarin derivative was obtained at the modified carbon paste electrode (DC/IL–CTP) by direct electron transfer between the coumarin derivative and the CP electrode. Dramatically enhanced electrocatalytic activity was exemplified at the DC/IL–CTP electrode, as an electrochemical sensor to study the electro oxidation of levodopa (LD) and carbidopa (CD). Based on differential pulse voltammetry (DPV), the oxidation of LD and CD exhibited the dynamic range between 0.10– 900.0 μM and 20.0–900.0 μM respectively, and the detection limit (3σ) for LD and CD were 41 nM and 0.38 μM, respectively. DPV was used for simultaneous determination of LD and CD at the DC/IL–CTP electrode, and quantitation of LD and CD in some real samples (such as tablets of Parkin-C Fort and Madopar, Sinemet, water, urine, and human blood serum) by the standard addition method.  相似文献   

14.
An electrochemical sensor for cinchonine (CCN) using the β-cyclodextrin (β-CD) modified poly(N-acetylaniline) (PAA) electrode has been developed, in which 1,4-hydroquinone (HQ) was chosen as a probe. Complexation of HQ with β-CD modified on the glassy carbon electrode (GCE) was examined by cyclic voltammetry (CV). HQ was included in the cavity of β-CD and reversible voltammograms were observed. In the presence of CCN, a competitive inclusion equilibrium with β-CD was established between HQ and CCN, lowering the peak current of HQ. The decrease in the peak current of HQ is directly proportional to the amount of CCN. Linear calibration plot was obtained over the range from 4.0 × 10−6 to 8.0 × 10−5 M with a detection limit (S/N = 3) of 2.0 × 10−6 M. From the inhibitory effect of CCN on the inclusion of HQ by β-CD, the apparent formation constant of CCN with the immobilized β-CD was estimated. This electrochemical sensor showed excellent sensitivity, repeatability, stability and recovery for the determination of CCN. The response mechanism of the sensor was discussed in detail. The optimum steric configuration of inclusion complex was presented by molecular dynamics simulation.  相似文献   

15.
Titanium dioxide (TiO2) nanoparticles (NPs) with different sizes and structures were probed for plausible cytotoxicity using electric cell-substrate impedance sensing (ECIS), a non-invasive and on-line procedure for continuous monitoring of cytotoxicity. For insect cells (Spodoptera frugiperda Sf9), the ECIS50 values, i.e., the concentration required to achieve 50% inhibition of the response, differed depending on the size and shape of the TiO2 nanostructure. The lowest ECIS50 value (158 ppm) was observed for the needle shaped rutile TiO2 (10 nm × 40 nm, 15.5 nm nominal particle size), followed by 211 ppm for P-25 (34.1 nm, 80% anatase and 20% rutile), 302 ppm for MTI5 (5.9 nm, 99% anatase) and 417 ppm for Hombitan LW-S bulk TiO2 (169.5 nm, 99% anatase). Exposure of TiO2 NPs to UV light at 254 nm or 365 nm exhibited no significant effect on the ECIS50 value due to the aggregation of TiO2 NPs with diminishing photocatalytic activities. Chinese hamster lung fibroblast V79 cells, exhibited no significant cytotoxicity/inhibition up to 400 ppm with P25, MTI5 and bulk TiO2. However, a noticeable inhibitory effect was observed (ECIS50 value of 251 ppm) with rutile TiO2 as cell spreading on the electrode surface was prevented  相似文献   

16.
Xuemei Ma 《Tetrahedron》2008,64(2):345-350
A novel organic cyanine dye containing triphenylamine-benzothiadiazole dyad has been synthesized and applied successfully to sensitization of nanocrystalline TiO2-based solar cell. Their absorption spectra, electrochemical, and photovoltaic properties were studied. Upon adsorption on a TiO2 electrode, the absorption spectra of the cyanine dye are all broadened at both the red and blue spectral ends relative to its respective spectra in acetonitrile and ethanol mixture solution. An overall conversion efficiency of 7.62% (Jsc=22.10 mA cm−2, Voc=0.54 V, ff=0.48) is achieved under irradiation with 75 mW cm−2 white light from a Xe lamp.  相似文献   

17.
Wei Zhao  Xia Qin  Zixia Zhao  Lili Chen  Yuxin Fang 《Talanta》2009,80(2):1029-943
A novel strategy to fabricate hydrogen peroxide (H2O2) sensor was developed based on multi-wall carbon nanotube/silver nanoparticle nanohybrids (MWCNT/Ag nanohybrids) modified gold electrode. The process to synthesize MWCNT/Ag nanohybrids was facile and efficient. In the presence of carboxyl groups functionalized multi-wall carbon nanotubes (MWCNTs), silver nanoparticles (Ag NPs) were in situ generated from AgNO3 aqueous solution and readily attached to the MWCNTs convex surfaces at room temperature, without any additional reducing reagent or irradiation treatment. The formation of MWCNT/Ag nanohybrids product was observed by transmission electron microscope (TEM), and the electrochemical properties of MWCNT/Ag nanohybrids modified gold electrode were characterized by electrochemical measurements. The results showed that this sensor had a favorable catalytic ability for the reduction of H2O2. The resulted sensor could detect H2O2 in a linear range of 0.05-17 mM with a detection limit of 5 × 10−7 M at a signal-to-noise ratio of 3. The sensitivity was calculated as 1.42 μA/mM at a potential of −0.2 V. Additionally, it exhibited good reproducibility, long-term stability and negligible interference of ascorbic acid (AA), uric acid (UA), and acetaminophen (AP).  相似文献   

18.
19.
Nafion covered core–shell structured Fe3O4@graphene nanospheres (GNs) modified glassy carbon electrode (GCE) was successfully prepared and used for selective detection dopamine. Firstly, the characterizations of hydro-thermal synthesized Fe3O4@GNs were investigated by scanning electron microscopy (SEM), transmission electron microscopy (TEM) and Raman spectroscopy. Then Fe3O4@GNs/Nafion modified electrode exhibited excellent electrocatalytic activity toward the oxidations of dopamine (DA). The interference test showed that the coexisted ascorbic acid (AA) and uric acid (UA) had no electrochemical interference toward DA. Under the optimum conditions, the broad linear relationship was obtained in the experimental concentration from 0.020 μM to 130.0 μM with the detection limit (S/N = 3) of 0.007 μM. Furthermore, the core–shell structured Fe3O4@GNs/Nafion/GCE was applied to the determination of DA in real samples and satisfactory results were got, which could provide a promising platform to develop excellent biosensor for detecting DA.  相似文献   

20.
A novel electrochemical sensor based on Cu-MOF-199 [Cu-MOF-199 = Cu3(BTC)2 (BTC = 1,3,5-benzenetricarboxylicacid)] and SWCNTs (single-walled carbon nanotubes) was fabricated for the simultaneous determination of hydroquinone (HQ) and catechol (CT). The modification procedure was carried out through casting SWCNTs on the bare glassy carbon electrode (GCE) and followed by the electrodeposition of Cu-MOF-199 on the SWCNTs modified electrode. Cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS) and scanning electron microscopy (SEM) were performed to characterize the electrochemical performance and surface characteristics of the as-prepared sensor. The composite electrode exhibited an excellent electrocatalytic activity with increased electrochemical signals towards the oxidation of HQ and CT, owing to the synergistic effect of SWCNTs and Cu-MOF-199. Under the optimized condition, the linear response range were from 0.1 to 1453 μmol L−1 (RHQ = 0.9999) for HQ and 0.1–1150 μmol L−1 (RCT = 0.9990) for CT. The detection limits for HQ and CT were as low as 0.08 and 0.1 μmol L−1, respectively. Moreover, the modified electrode presented the good reproducibility and the excellent anti-interference performance. The analytical performance of the developed sensor for the simultaneous detection of HQ and CT had been evaluated in practical samples with satisfying results.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号