共查询到20条相似文献,搜索用时 15 毫秒
1.
A new tetraphenylethylene (TPE)-based sensor M1 bearing double 2-methylpyridyl-2-methylthiophenylamino units linked with triazole moieties was reported. Both UV–vis and fluorescence spectroscopic studies demonstrated that M1 was highly sensitive and selective toward Fe3+ over other metal ions in THF/H2O solution based on the aggregation-induced emission quenching mechanism. The lowest detection limit of M1 for Fe3+ is 0.7 μM. The detailed fluorescent titration study suggested that the binding stoichiometry of the M1–Fe3+ complex was 1:2, and the structure between M1 and the Fe3+ complex was confirmed by the 1H NMR titration. 相似文献
2.
A simple Schiff-base derivative with salicylaldehyde moieties as fluorescent probe 1 was reported by aggregation-induced emission (AIE) characterization for the detection of metal ions. Spectral analysis revealed that probe 1 was highly selective and sensitive to Al3+. The probe 1 was also subject to minimal interference from other common competitive metal ions. The detection limit of Al3+ was 0.4 μM, which is considerably lower than the World Health Organization standard (7.41 μM), and the acceptable level of Al3+ (1.85 μM) in drinking water. The Job's plot and the results of 1H-NMR and FT-IR analyses indicated that the binding stoichiometry ratio of probe 1 to Al3+ was 1:2. Probe 1 demonstrated a fluorescence-enhanced response upon binding with Al3+ based on AIE characterization. This response was due to the restricted molecular rotation and increased rigidity of the molecular assembly. Probe 1 exhibited good biocompatibility, and Al3+ was detected in live cells. Therefore, probe 1 is a promising fluorescence probe for Al3+ detection in the environment. 相似文献
3.
Zhengqiang Li Qiuping HuChunxiao Li Jintao DouJiaojie Cao Weikai ChenQingzeng Zhu 《Tetrahedron letters》2014
A novel N-(3-aminopropyl)-imidazole-appended rhodamine-based fluorescent chemosensor was synthesized. The sensing behavior and selectivity of the synthesized chemosensor toward metal cations were studied by UV/vis and fluorescence spectroscopy. The chemosensor recognized Al3+ ions by a significantly enhanced fluorescence and a visible color change due to opening of the spirolactam ring triggered by the addition of Al3+ ions. 相似文献
4.
The design, synthesis, and photophysical evaluation of a new naphthalimide-based fluorescent chemosensor, N-butyl-4-[di-(2-picolyl)amino]-5-(2-picolyl)amino-1,8-naphthalimide (1), were described for the detection of Zn2+ in aqueous acetonitrile solution at pH 7.0. Probe 1 showed absorption at 451 nm and a strong fluorescence emission at 537 nm (ΦF=0.33). The capture of Zn2+ by the receptor resulted in the deprotonation of the secondary amine conjugated to 1,8-naphthalimide so that the electron-donating ability of the N atom would be greatly enhanced; thus probe 1 showed a 56 nm red-shift in absorption (507 nm) and fluorescence spectra (593 nm, ΦF=0.14), respectively, from which one could sense Zn2+ ratiometrically and colorimetrically. The deprotonated complex, [(1-H)/Zn]+, was calculated at m/z 619.1800 and measured at m/z 618.9890. In contrast to these results, the emission of 1 was thoroughly quenched by Cu2+, Co2+, and Ni2+. The addition of other metal ions such as Li+, Na+, K+, Mg2+, Ca2+, Fe3+, Mn2+, Al3+, Cd2+, Hg2+, Ag+, and Pb2+ produced a nominal change in the optical properties of 1 due to their low affinity to probe 1. This means that probe 1 has a very high fluorescent imaging selectivity to Zn2+ among metal ions. 相似文献
5.
Qiuping Hu Yuling Liu Zhengqiang Li Rongzheng Wen Yuan Gao Yiling Bei Qingzeng Zhu 《Tetrahedron letters》2014
A new rhodamine B derivative bearing a hydrazone group has been designed and prepared. The synthesized colorimetric and fluorescent molecular chemosensor can be used as a dual probe, selectively detecting Al3+ and Cu2+ in acetonitrile solution by monitoring changes in the absorption and fluorescence spectral patterns. The results show that Al3+ ions can induce a greater fluorescence enhancement, while the addition of Cu2+ ions induces a strong UV–vis absorption enhancement with weak fluorescence. The limits of detection of Cu2+ and Al3+ were estimated to be 2.9 × 10−7 M and 8.3 × 10−9 M, respectively. 相似文献
6.
A Schiff base-type fluorescent probe (1) consist of 2-hydroxynaphthaldehyde and glutamide moieties has been designed and synthesized for detection Zn2+ and Al3+. The probe shows pH dependent dual-selectivity for Zn2+ and Al3+ in Tris-HCl buffer, viz. that can selectively recognized Zn2+ at pH 7.4 and Al3+ at pH 6.0, respectively. From Job's plots and MS data, the stoichiometric ratios of the probe with Zn2+ and Al3+ appeared to be 1:1 and 2:1, respectively. The probe can detect as low as 5.5 × 10−8 M−1 Zn2+ and 1.27 × 10−7 M−1 Al3+, whereas respective association constants are 4.27 × 104 M−1 and 3.50 × 109 M−1. Furthermore, it is also confirmed that the probe has good cell-permeability and could thus be used to selectively sense intracellular Zn2+ and Al3+ by bioimaging in different pH environment. Finally the probe has been used successfully for determination of the analytes in real drug samples. 相似文献
7.
Aasif Helal 《Tetrahedron》2010,66(52):9925-9932
A new thiazole sulfonamide (TTP, 1) based Zn2+ selective intrinsic chemosensor has been synthesized and investigated. The chemosensor shows a selective fluorescence enhancement (3.0 fold) with Zn2+ over biologically relevant cations (Ca2+, Mg2+, Na+, and K+) and biologically non-relevant cations (Cd2+) in an aqueous ethanol system. It produces an increase in the quantum yield and a longer emission wavelength shift (64 nm) on Zn2+ binding with the potential of a ratiometric assay. 相似文献
8.
A novel Cu2+-specific “off-on” fluorescent chemosensor of naphthalimide modified rhodamine B (naphthalimide modified rhodamine B chemosensor, NRC) was designed and synthesized, based on the equilibrium between the spirolactam (non-fluorescence) and the ring-opened amide (fluorescence). The chemosensor NRC showed high Cu2+-selective fluorescence enhancement over commonly coexistent metal ions or anions in neutral aqueous media. The limit of detection (LOD) based on 3 × δblank/k was obtained as low as 0.18 μM of Cu2+, as well as an excellent linearity of 0.05-4.5 μM (R = 0.999), indicating the chemosensor of high sensitivity and wide quantitation range. And also the coordination mode with 1:1 stoichiometry was proposed between NRC and Cu2+. In addition, the effects of pH, co-existing metal ions and anions, and the reversibility were investigated in detail. It was also demonstrated that the NRC could be used as an excellent “off-on” fluorescent chemosensor for the measurement of Cu2+ in living cells with satisfying results, which further displayed its valuable applications in biological systems. 相似文献
9.
Naphthalimide derivative (compound 1) containing hydrophilic hexanoic acid group was synthesized and used to recognize Hg2+ in aqueous solution. The fluorescence enhancement of 1 is attributed to the formation of a complex between 1 and Hg2+ by 1:1 complex ratio (K = 2.08 × 105), which has been utilized as the basis of fabrication of the Hg2+-sensitive fluorescent chemosensor. The comparison of this method with some other fluorescence methods for the determination of Hg2+ indicated that the method can be applied in aqueous solution rather than organic solution. The analytical performance characteristics of the proposed Hg2+-sensitive chemosensor were investigated. The chemosensor can be applied to the quantification of Hg2+ with a linear range covering from 2.57 × 10−7 to 9.27 × 10−5 M and a detection limit of 4.93 × 10−8 M. The experiment results show that the response behavior of 1 toward Hg2+ is pH independent in medium condition (pH 4.0–8.0). Most importantly, the fluorescence changes of the chemosensor are remarkably specific for Hg2+ in the presence of other metal ions, which meet the selective requirements for practical application. Moreover, the response of the chemosensor toward Hg2+ is fast (response time less than 1 min). In addition, the chemosensor has been used for determination of Hg2+ in hair samples with satisfactory results, which further demonstrates its value of practical applications. 相似文献
10.
A new Excited-State Intramolecular Proton Transfer (ESIPT) based fluorescent probe for the detection of Hg2+ has been rationally designed and developed. Based on the specific reactivity of mercury-promoted hydrolysis, the probe exhibits high selectivity and sensitivity for mercury ions in almost pure aqueous solution (containing only 1% DMSO) with a low detection limit of 1.9?ppb. Furthermore, the probe was also successfully used for fluorescence imaging of Hg2+ in live cells. 相似文献
11.
Xi Dai Tao Zhang Zhi-Fang Du Xiang-Jian Cao Ming-Yu Chen Sheng-Wen Hu Jun-Ying Miao Bao-Xiang Zhao 《Analytica chimica acta》2015
We have developed the first two-photon colorimetric and ratiometric fluorescent probe, BICO, for the detection of bisulfite (HSO3−) in aqueous solution. The probe contains coumarin and benzimidazole moieties and can detect HSO3− based on the Michael addition reaction with a limit of detection 5.3 × 10−8 M in phosphate-buffered saline solution. The probe was used to detect bisulfite in tap water, sugar and dry white wine. Moreover, test strips were made and used easily. We successfully applied the probe to image living cells, using one-photon fluorescence imaging. BICO overcomes the limitations in sensitivity of previously reported probes and the solvation effect of bisulfite, which demonstrates its excellent value in practical application. 相似文献
12.
A novel probe incorporating quaternized 4-pyridinium group into a BODIPY molecule was synthesized and studied for the selective detection of fluoride ions (F−) in aqueous solution. The design was based on a fluoride-specific desilylation reaction and the “Turn-On” fluorescent response of probe 1 to F− was ascribed to the inhibition of photoinduced electron transfer (PET) process. The probe displayed many desired properties such as high specificity, appreciable solubility, desirable response time and low toxicity to mammalian cells. There was a good linearity between the fluorescence intensity and the concentrations of F− in the range of 0.1–1 mM with a detection limit of 0.02 mM. The sensing mechanism was confirmed by the NMR, electrospray ionization mass spectrum, optical spectroscopy and the mechanism of “Turn-On” fluorescent response was also determinated by a density functional theory (DFT) calculation using Gaussian 03 program. Moreover, the probe was successfully applied for the fluorescence imaging of F− in human epithelial lung cancer (A549) cells and alveolar type II (ATII) cells under physiological conditions. 相似文献
13.
In this paper we unveil a novel rhodamine compound based fluorescent chemosensor (1-Pb2+) for colormetric and fluorescent detection of citrate in aqueous solution. This is the first fluorescent chemosensor for citrate based on rhodamine compound. The comparison of this method with some other fluorescence methods for citrate indicates that the method can detect citrate in aqueous solution by both color changes and fluorescent changes with long emission wavelength. In the new developed sensing system, 1-Pb2+ is fluorescent due to Pb2+-induced fluorescence enhancement of 1. However, the addition of citrate may release 1 into the solution with quenching of fluorescence. The chemosensor can be applied to the quantification of citrate with a linear range covering from 1.0 × 10−7 to 5.0 × 10−5 M and a detection limit of 2.5 × 10−8 M. The experiment results show that the response behavior of 1-Pb2+ towards citrate is pH independent in medium condition (pH 6.0–8.0). Most importantly, the fluorescence changes of the chemosensor are remarkably specific for citrate in the presence of other anions (even those that exist in high concentration), which meet the selective requirements for practical application. Moreover, the response of the chemosensor toward citrate is fast (response time less than 1 min). In addition, the chemosensor has been used for determination of citrate in urine samples with satisfactory results. 相似文献
14.
《Tetrahedron》2019,75(36):130489
An aggregation-induced emission (AIE)-active fluorescent chemosensor based on a tetraphenylethene (TPE) unit has been successfully designed and synthesized. Interestingly, the luminogen could detect Zn2+ selectively in a THF solution with the detection limit of 1.24 × 10−6 mol L−1. Meanwhile, the luminogen could also detect Hg2+ selectively in a THF-water mixture with the water content of 90%, and the detection limit was 2.55 × 10−9 mol L−1. Furthermore, the solid-state mechanochromic fluorescence behavior of the luminogen was investigated systematically. Indeed, the AIE-active luminogen also exhibited reversible mechanofluorochromic phenomenon involving fluorescent color change from blue to green, and powder X-ray diffraction results indicated that the switchable morphology conversion between crystalline and amorphous states was responsible for this mechanochromism phenomenon. 相似文献
15.
Zhi-Xiang Han Hong-Yuan Luo Xiao-Bing Zhang Rong-Mei Kong Guo-Li Shen Ru-Qin Yu 《Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy》2009,72(5):1084-1088
Quinolin-8-ol p-[10′,15′,20′-triphenyl-5′-porphyrinyl]benzoate (1) was synthesized for the first time and developed as a ratiometric fluorescent chemosensor for recognition of Hg2+ ions in aqueous ethanol with high selectivity. The 1–Hg2+ complexation quenches the fluorescence of porphyrin at 646 nm and induces a new fluorescent enhancement at 603 nm. The fluorescent response of 1 towards Hg2+ seems to be caused by the binding of Hg2+ ion with the quinoline moiety, which was confirmed by the absorption spectra and 1H NMR spectrum. The fluorescence response fits a Hill coefficient of 1 (1.0308), indicating the formation of a 1:1 stoichiometry for the 1–Hg2+ complex. The analytical performance characteristics of the chemosensor were investigated. The sensor shows a linear response toward Hg2+ in the concentration range of 3 × 10−7 to 2 × 10−5 M with a limit of detection of 2.2 × 10−8 M. Chemosensor 1 shows excellent selectivity to Hg2+ over transition metal cations except Cu2+, which quenches the fluorescence of 1 to some extent when it exists at equal molar concentration. Moreover, the chemosensor are pH-independent in 5.0–9.0 and show excellent selectivity for Hg2+ over transition metal cations. 相似文献
16.
Aasif Helal 《Tetrahedron letters》2009,50(39):5510-2293
A new ratiometric and selective fluorescent chemosensor (1), based on thiazole for quantification of zinc ions in aqueous ethanol, was synthesized and investigated. The mechanism of fluorescence was based on the cation-induced inhibition of excited-state intramolecular proton transfer (ESIPT). 相似文献
17.
A cyano-substituted diarylethlene derivative aggregation-induced emission (ALE) dye with two amino end-groups and 4,4'-(hexafluoroisopropylidene)diphthalic anhydride were facilely incorporated into red fluorescent organic nanoparticles (FONs) via room temperature anhydride ring-opening polymerization under an air atmosphere. These obtained RO-HFDA FONs were characterized by a series of techniques including gel permeation chromatography, Fourier transform infrared spectroscopy, size distribution and zeta potential measurements, UV-Vis absorption spectrum, fluorescent spectroscopy and transmission electron microscopy. Biocompatibility evaluation and cell uptake behavior of RO-HFDA FONs were further investigated to explore their potential biomedical application. We demonstrated that such FONs showed high water dispersibility, stable uniform spherical morphology (150-200 nm), broad excitation band (350-605 nm), intense red fluorescence (627 nm) and excellent biocompatibility, making them promising for cell imaging applications. 相似文献
18.
Umesh A. Fegade Suban K. Sahoo Amanpreet Singh Narinder Singh Sanjay B. Attarde Anil S. Kuwar 《Analytica chimica acta》2015
A fluorescent based receptor (4Z)-4-(4-diethylamino)-2-hydroxybenzylidene amino)-1,2dihydro-1,5-dimethyl-2-phenylpyrazol-3-one (receptor 3) was developed for the highly selective and sensitive detection of Cu2+ and Zn2+ in semi-aqueous system. The fluorescence of receptor 3 was enhanced and quenched, respectively, with the addition of Zn2+ and Cu2+ ions over other surveyed cations. The receptor formed host-guest complexes in 1:1 stoichiometry with the detection limit of 5 nM and 15 nM for Cu2+ and Zn2+ ions, respectively. Further, we have effectively utilized the two metal ions (Cu2+ and Zn2+) as chemical inputs for the manufacture of INHIBIT type logic gate at molecular level using the fluorescence responses of receptor 3 at 450 nm. 相似文献
19.
We have successfully developed a ‘turn-on’ colorimetric chemosensor for Fe3+ based on 1,10-phenanthroline. An amide derivative of 1,10-phenanthroline 4 was developed for the selective recognition of Fe3+ over Co2+, Cr3+, Cu2+, Mn2+, Ni2+, Ag+ and Zn2+ and could measure Fe3+ concentration in the range of 15–210 μM by UV–vis spectroscopy. Moreover, the addition of Fe3+ to a colourless solution of 4 turned its colour to light pink, indicating that 4 is capable of detecting Fe3+ by the naked eye. Compound 4 exhibits a major absorption band centred at 268 which shifted to 278 nm after addition of Fe3+, and a shoulder band around 514 nm was also observed. The complexation of Fe3+ with 4 was analysed at a different pH and favourable binding was observed at pH 6.2. 相似文献
20.
Sanchita Mondal Saikat Kumar Manna Kalipada Maiti Rajkishor Maji Syed Samim Ali Srimanta Manna 《Supramolecular chemistry》2017,29(8):616-626
A FRET-based chemosensor L containing donor phenanthroline and acceptor fluorescein moiety was designed, synthesised and characterised for the ratiometric fluorescent detection of Cu2+ in organo-aqueous solution. Probe L showed high selectivity and excellent sensitivity towards Cu2+ ions by exhibiting both colorimetric and fluorometric changes due to opening of the spirolactum ring of fluorescein upon complexation with Cu2+. In presence of Cu2+ ions, probe L formed L-Cu2+ complex in 1:1 stoichiometric fashion which is established on the basis of Job’s plot and mass spectroscopy. We also performed DFT computational studies to know the binding nature and coordination feature of the complex. Furthermore, fluorescence imaging studies revealed that probe L was cell permeable and could be used to detect intracellular Cu2+ in living cells. 相似文献