首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Xiaoyu Liu  Jinghe Yang 《Talanta》2010,81(3):760-1691
A new method for detecting protein by synchronous fluorescence enhancement was developed, based on the combination of near infrared (NIR) fluorescence and the dedimerization phenomenon of methylene blue (MB). Under analytical conditions, there are linear relationships between the enhancing extent of synchronous fluorescence of MB-sodium dodecyl benzene sulfonate (SDBS)-protein at 667 nm and the concentration of protein in the range of 8.0 × 10−8-4.0 × 10−5 g mL−1 for bovine serum albumin (BSA), 1.0 × 10−7-3.5 × 10−5 g mL−1 for egg albumin (EA). The detection limits (S/N = 3) of BSA and EA are 8.9 ng mL−1 and 10.0 ng mL−1, respectively. The fluorescence enhancement mechanism is discussed in detail. Results from multiple techniques indicate that the fluorescence enhancement of the system originates from the hydrophobic microenvironment provided by BSA and SDBS, and the formation of an MB-SDBS-BSA complex, as well as the deaggregation of some MB dimer.  相似文献   

2.
Changlun Tong  Zhou Hu 《Talanta》2007,71(2):816-821
The fluorescence intensity of the enoxacin (ENX)-Tb3+ complex enhanced by DNA was studied. On the basis of this study, an environmentally friendly fluorescence probe of enoxacin-Tb3+ for the determination of single-stranded and double-stranded DNA was developed. Under the optimal conditions, the enhanced fluorescence intensity was in proportion to the concentration of DNA in the range of 2.0 × 10−8 to 2.0 × 10−6 g mL−1 for hsDNA, 1.0 × 10−8 to 1.0 × 10−6 g mL−1 for ctDNA and 5.0 × 10−9 to 1.0 × 10−6 g mL−1 for thermally denatured ctDNA. The detection limits (S/N = 3) were 5.0, 9.0 and 3.0 ng mL−1, respectively. The interaction modes between ENX-Tb3+ and DNA and the mechanism of the fluorescence enhancement were also discussed in details. The experimental results from UV absorption spectra, fluorescence spectra and the competing combination tests between the ENX-Tb3+ complex and EB probe indicated that the possible interaction modes between enoxacin-Tb3+ complex and DNA had at least two different binding modes: the electrostatic binding and the intercalation binding. Additionally, this fluorescence probe was used to study the interaction between heavy metals and DNA.  相似文献   

3.
Fu S  Liu Z  Liu S  Liu J  Yi A 《Analytica chimica acta》2007,599(2):271-278
In pH 2.8-3.8 BR buffer medium, the third generation cephalosporin antibiotics (TGCs) such as ceftazidime (CZD), ceftriaxone (CTRX), cefoperazone (CPZ), and cefotaxime (CFTM) react with palladium(II) (Pd(II)) to form 1:2 yellowish-brown cationic chelates, which further react with 4, 5-dibromofluorescein (DBF) to form 1:3 brown ion-association complexes. As a result, not only the spectra of absorption and fluorescence are changed, but also the resonance Rayleigh scattering (RRS) is enhanced greatly and the new RRS spectra are observed. The four TGCs products have similar spectral characteristics and their maximum RRS wavelengths are all located at 291 nm. The quantitative determination ranges and the detection limits of the four TGCs are 0.0065-1.0 μg mL−1 and 2.0 ng mL−1 for CZD, 0.0070-1.1 μg mL−1 and 2.2 ng mL−1 for CTRX, 0.0090-1.6 μg mL−1 and 2.7 ng mL−1 for CPZ, and 0.014-2.2 μg mL−1 and 4.2 ng mL−1 for CFTM, respectively. The optimum conditions of the reactions and the effects of foreign substances are investigated, and the composition of ion-association complexes is discussed also. Based on the ion-association reaction, a highly sensitive, simple and rapid method has been proposed to the determination of TGCs.  相似文献   

4.
Wu X  Zheng J  Ding H  Ran D  Xu W  Song Y  Yang J 《Analytica chimica acta》2007,596(1):16-22
It was found that oxolinic acid (OA) at high concentration can self-assemble into nano- to micro- meter scale OA aggregates in Tris-HCl (pH 7.48) buffer solution. The nanoparticles of OA were adopted as fluorescence probes in the quantitative analysis of proteins. Under optimum conditions, the fluorescence quenching extent of nanometer scale OA aggregates was in proportion to the concentration of albumins in the range of 3.0 × 10−8 to 3.0 × 10−5 g mL−1 for bovine serum albumin (BSA) and 8.0 × 10−8 to 8.0 × 10−6 g mL−1 for human serum albumin (HSA). The detection limits (S/N = 3) were 3.4 × 10−9 g mL−1 for BSA, and 2.6 × 10−8 g mL−1 for HSA, respectively. Samples were satisfactorily determined. The interaction mechanism of the system was studied using fluorescence, UV-vis, resonance light scattering (RLS) and transmission electron microscope (TEM) technology, etc., indicating that the nonluminescent complex was formed between serum albumin molecular and OA, to disaggregate the self-association of OA, which resulted in the dominated static fluorescence quenching in the system.  相似文献   

5.
New silver nanoparticles coated with EDTA (EDTA-AgNPs) have been synthesized by citrate reduction method and characterized by UV-vis spectroscopy, molecular fluorescence and scanning electron microscopy (SEM). The derivatized nanoparticles show fluorescent emission and second order scattering (SOS) signals which in presence of nitrate are both attenuated. The SOS decreasing is greater than its fluorescent quenching; considering this fact, a new ultra sensitive methodology using the derivatized silver nanoparticles as sensor for nitrate determination has been developed. Under optimal established conditions, a linear response has been obtained within the range of 6.4 × 10−4 to 3.0 μg mL−1 nitrate concentrations, with a detection limit of 1.8 × 10−4 μg mL−1. This novel technique provides a sensitive and selective methodology for nitrate determination and has been satisfactorily applied to its quantification in parenteral solutions.  相似文献   

6.
Zhuo SJ  Zheng H  Chen JL  Li DH  Wu YQ  Zhu CQ 《Talanta》2004,64(2):528-533
A new method was developed for determination of micro amounts of nucleic acids based on near-infrared (near-IR) fluorescence recovery, employing a two-reagent system which is composed of an anionic tetracarboxy aluminum phthalocyanine (AlC4Pc) and a cationic tetra-N-hexadecylpyridiniumyl porphyrin (TC16PyP). The fluorescence of the AlC4Pc, with the maximum emission wavelength at 701 nm, could be quenched by TC16PyP at its proper concentration, but recovered by adding nucleic acids. Under optimal conditions, the recovered fluorescence is proportional to the concentration of nucleic acids. The calibration graphs are linear over the range of 1-200 ng mL−1 for fish sperm DNA (FS DNA) and 2-400 ng mL−1 for calf thymus DNA (CT DNA). The corresponding detection limits are 0.59 ng mL−1 for FS DNA and 0.82 ng mL−1 for CT DNA, respectively. Four synthetic and three real nucleic acid samples were determined with satisfactory results.  相似文献   

7.
Four simple, rapid, accurate, precise, reliable and economical spectrophotometric methods have been proposed for simultaneous determination of salbutamol sulphate (SS), bromhexine hydrochloride (BH) and etofylline (ET) in pure and commercial formulations without any prior separation or purification. They were first derivative zero crossing spectrophotometry (method 1), simultaneous equation method (method 2), derivative ratio spectra zero crossing method (method 3) and double divisor ratio spectra derivative method (method 4). The ranges for SS, BH and ET were found to be 1-35 μg mL−1, 4-40 μg mL−1 and 5-80 μg mL−1. For methods 1 and 2, the values of limit of detection (LOD) were 0.2314 μg mL−1, 0.4865 μg mL−1 and 0.2766 μg mL−1 and the values of limit of quantitation (LOQ) were 0.7712 μg mL−1, 1.6217 μg mL−1 and 0.9221 μg mL−1 for SS, BH and ET, respectively. For method 3, LOD values were 0.3297 μg mL−1, 0.2784 μg mL−1 and 0.7906 μg mL−1 and LOQ values were 0.9325 μg mL−1, 0.9282 μg mL−1 and 2.6352 μg mL−1 for SS, BH and ET, respectively. For method 4, LOD values were 0.3161 μg mL−1, 0.2495 μg mL−1 and 0.2064 μg mL−1 and LOQ values were 0.9869 μg mL−1, 0.8317 μg mL−1 and 0.6879 μg mL−1 for SS, BH and ET. The precision values were less then 2% R.S.D. for all four methods. The common excipients and additives did not interfere in their determinations. The results obtained by the proposed methods have been statistically compared by means of Student t-test and by the variance ratio F-test.  相似文献   

8.
A new continuous fluorescence turn-on assay for protease activity and inhibitor screening has been developed. A fluorophore labeled single stranded DNA (FAM-DNA) and cytochrome c (cyt c) were employed. The fluorescence of the FAM-DNA was efficiently quenched when binding to cyt c, through the electron transfer between the FAM fluorophore and the heme cofactor of cyt c. In the presence of a protease, such as trypsin, cyt c was digested into small peptide fragments. The FAM-DNA was released, which resulted in the recovery of the FAM fluorescence. The rate of the cyt c digestion could be reduced via the addition of an inhibitor. As a result, reduced degree of the fluorescence recovery was obtained. The limit of detection of our assay is 1 nM trypsin and the IC50 values are 3.23 μg mL−1 and 0.303 μg mL−1 for the inhibitor from egg white and the inhibitor from soybean, respectively. Our method could be used for the sensing of protease activity for various biochemical applications, and for the screening of protease inhibitors as drugs for the treatment of various related diseases.  相似文献   

9.
A fast, simple, and sensitive flow injection analysis method was developed for the measurement of semicarbazide-sensitive amine oxidase (SSAO) activity in human serum. Benzaldehyde, generated by the action of SSAO after incubation of serum with benzylamine, was derivatized with a novel aromatic aldehyde-specific reagent (1,2-diaminoanthraquinone) and the fluorescent product was measured by fluorescence detection at excitation and emission wavelengths of 390 and 570 nm, respectively. Serum SSAO activity was defined as benzaldehyde (nmol) formed per milliliter serum per hour. The method was linear over SSAO activity of 0.2–150.0 nmol mL−1 h−1 with a detection limit of 0.06 nmol mL−1 h−1. The %RSD of intra-day and inter-day precision did not exceed 9.4% and the accuracy ranged from −6.5 to −0.6%. The method was applied for the determination of the serum SSAO activity in healthy controls (C, n = 24) and diabetes mellitus patients (DM, n = 18). It was demonstrated that the activity (mean ± SE) of SSAO in diabetics sera was significantly higher than that in healthy subjects’ ones (DM; 73.3 ± 1.8 nmol mL−1 h−1vs C; 58.9 ± 2.2 nmol mL−1 h−1, P 0.01).  相似文献   

10.
In the presented work, a disposable immunosensor for the detection of testosterone, an endogenous steroid hormone, in bovine urine has been developed using screen-printed electrodes (SPEs). Due to concerns over the use of steroid hormones as growth promoters, the EU prohibits their use in food producing animals. Consequently, rigorous screening procedures have been implemented in all member states to detect the illegal administration of such compounds. Competitive immunoassays were developed, initially by enzyme linked immunosorbent assay (ELISA), and subsequently transferred to an electrochemical immunosensor format using disposable screen-printed carbon electrodes. Horseradish peroxidase (HRP) was the enzyme label of choice and chronoamperometric detection was carried out using a tetramethylbenzidine/hydrogen peroxide (TMB/H2O2) substrate system, at +100 mV. The EC50 values obtained for the assay in buffer and urine gave relatively comparable results, 710 pg mL−1 and 960 pg mL−1, respectively. The linear range obtained for the assay in buffer extended from 0.03 ng mL−1 to 40 ng mL−1; while that in urine ranged from 0.03 ng mL−1 to 1.6 ng mL−1. The corresponding limits of detection (LOD) in buffer and urine were 26 pg mL−1 and 1.8 pg mL−1. Cross reactivity profiles of the antibody have been examined, with notable cross reactivities with 19-nortestosterone (11.6%) and boldenone (9.86%). Precision studies for the sensor demonstrated adequate reproducibility (CV < 13%, n = 3) and repeatability (CV < 9%, n = 3). Recovery data obtained showed good agreement between spiking studies and known concentrations of analyte. Sensors showed stability for 4 days at +4 °C. A sensitive, highly specific, inexpensive, disposable immunosensor, showing excellent overall performance for the detection of testosterone in bovine urine, has been developed.  相似文献   

11.
A novel photonic suspension array was developed for multiplex immunoassay. The carries of this array were silica colloidal crystal beads (SCCBs). The codes of these carriers are the characteristic reflection peak originated from their structural periodicity, and therefore they do not suffer from fading, bleaching, quenching, and chemical instability. In addition, because no dyes or materials related with fluorescence are included, the fluorescence background of SCCBs is very low. With a sandwich format, the proposed suspension array was used for simultaneous multiplex detection of tumor markers in one test tube. The results showed that the four tumor markers, α-fetoprotein (AFP), carcinoembryonic antigen (CEA), carcinoma antigen 125 (CA 125) and carcinoma antigen 19-9 (CA 19-9) could be assayed in the ranges of 1.0-500 ng mL−1, 1.0-500 ng mL−1, 1.0-500 U mL−1 and 3.0-500 U mL−1 with limits of detection of 0.68 ng mL−1, 0.95 ng mL−1, 0.99 U mL−1 and 2.30 U mL−1 at 3σ, respectively. The proposed array showed acceptable accuracy, detection reproducibility, storage stability and the results obtained were in acceptable agreement with those from parallel single-analyte test of practical clinical sera. This technique provides a new strategy for low cost, automated, and simultaneous multiplex immunoassay.  相似文献   

12.
Xiao-tong Chen 《Talanta》2010,80(5):1952-4801
A novel fluorescence turn-on detection method of human serum albumin (HSA) and bovine serum albumin (BSA) in aqueous solution is investigated using 2,4-dihydroxyl-3-iodo salicylaldehyde azine (DISA). Upon the addition of DISA to HSA/BSA solution, a fluorescence turn-on effect at 529 nm can be observed with a large stokes shift of ∼129 nm based on hydrophobic binding-mode between protein and dye. Under the optimal condition, the linear ranges of fluorescence intensity for HSA and BSA are 0.1-30 μg mL−1 with the relative correlation coefficient of R2 = 0.991 (n = 10) and 0.3-50 μg mL−1 with R2 = 0.997 (n = 10); and the detection limits for HSA and BSA based on IUPAC (CDL = 3Sb/m) are 20 ng mL−1 and 50 ng mL−1, respectively.  相似文献   

13.
Enriching the surface density of immobilized capture antibodies enhances the detection signal of antibody sandwich microarrays. In this study, we improved the detection sensitivity of our previously developed P-Si (porous silicon) antibody microarray by optimizing concentrations of the capturing antibody. We investigated immunoassays using a P-Si microarray at three different capture antibody (PSA – prostate specific antigen) concentrations, analyzing the influence of the antibody density on the assay detection sensitivity. The LOD (limit of detection) for PSA was 2.5 ng mL−1, 80 pg mL−1, and 800 fg mL−1 when arraying the PSA antibody, H117 at the concentration 15 μg mL−1, 35 μg mL−1, and 154 μg mL−1, respectively. We further investigated PSA spiked into human female serum in the range of 800 fg mL−1 to 500 ng mL−1. The microarray showed a LOD of 800 fg mL−1 and a dynamic range of 800 fg mL−1 to 80 ng mL−1 in serum spiked samples.  相似文献   

14.
We developed a flow injection (FI) method for the determination of thiomersal (sodium ethylmercurithiosalicylate, C9H9HgNaO2S) based on the UV/microwave (MW) photochemical, online oxidation of organic mercury, followed by cold vapor generation atomic fluorescence spectrometry (CVG-AFS) detection. Thiomersal was quantitatively converted in the MW/UV process to Hg(II), with a yield of 97 ± 3%. This reaction was followed by the reduction of Hg(II) to Hg(0) performed in a knotted reaction coil with NaBH4 solution, and AFS detection in an Ar/H2 miniaturized flame. The method was linear in the 0.01–2 μg mL−1 range, with a LOD of 0.003 μg mL−1. This method has been applied to the determination of thiomersal in ophthalmic solutions, with recoveries ranging between 97% and 101%. We found a mercury concentration in commercial ophthalmic solutions ranging between 7.5 and 59.0 μg mL−1.  相似文献   

15.
This paper presents the development of a new flow-injection system combined with solid-surface fluorescence detection for the determination of the widely used fungicide thiabendazole. Nylon powder was probed as a novel solid support for building the optosensor. The method is based on the on-line immobilization of thiabendazole onto nylon in a continuous flow system, followed by the measurement of its native fluorescence. Aqueous samples are directly injected in a water carrier, resulting in a very simple and economical method. The analytical figures of merit obtained using 1500 μL of sample and 75% methanol (v/v) as eluting solution were: linear calibration range from 8 to 120 ng mL−1 (the lowest value corresponds to the quantitation limit), relative standard deviation, 0.9% (n = 5) at a level of 64 ng mL−1, limit of detection calculated according to 1995 IUPAC recommendations is to 2.8 ng mL−1, and sampling rate of 14 samples h−1. The potential interference from other agrochemicals, metal ions and common anions, and the viability of determining thiabendazole in real water samples were also evaluated.  相似文献   

16.
Flow-injection post chemiluminescence determination of atropine sulfate   总被引:1,自引:0,他引:1  
A new post chemiluminescence (PCL) reaction was observed when atropine sulfate was injected into the reaction mixture after the finish of CL reaction of Ce(IV) and sodium sulfite. The possible mechanism for the PCL reaction was discussed via the investigation of the CL kinetic characteristics, the CL spectra, the UV absorption spectra and the fluorescence spectra of some related substances. The flow injection PCL method for the determination of atropine sulfate was established. The relative standard deviation (R.S.D.) was 2.8% (n = 11, c = 5.0 × 10−6 g mL−1). The PCL intensity responded linearly to the concentration of atropine sulfate in the range 1.0 × 10−6 to 5.0 × 10−5 g mL−1 with a linear correlation of 0.9947. The detection limit was 4 × 10−7 g mL−1 atropine sulfate. The method had been applied to the determination of atropine sulfate in the tablets and the results were consistent with the method of Chinese pharmacopoeia.  相似文献   

17.
A novel fluorescent probe for Cu2+ determination based on the fluorescence quenching of glyphosate (Glyp)-functionalized quantum dots (QDs) was firstly reported. Glyp had been used to modify the surface of QDs to form Glyp-functionalized QDs following the capping of thioglycolic acid on the core–shell CdTe/CdS QDs. Under the optimal conditions, the response was linearly proportional to the concentration of Cu2+ between 2.4 × 10−2 μg mL−1 and 28 μg mL−1, with a detection limit of 1.3 × 10−3 μg mL−1 (3δ). The Glyp-functionalized QDs fluorescent probe offers good sensitivity and selectivity for detecting Cu2+. The fluorescent probe was successfully used for the determination of Cu2+ in environmental samples. The mechanism of reaction was also discussed.  相似文献   

18.
Jiang ZL  Zhang BM  Liang AH 《Talanta》2005,66(3):783-788
A new simple, selective and sensitive method for the determination of trace chlorine dioxide in water has been developed, based on the oxidation by chlorine dioxide to reduction the fluorescence of rhodamine dyes in ammonia-ammonium chloride buffer solution. Four rhodamine dyes systems such as rhodamine S, rhodamine G, rhodamine B and butyl-rhodamine B were tested. The rhodamine S system is the best, with a linear range of 0.0060-0.450 μg mL−1 and a detection limit of 0.0030 μg mL−1 ClO2. It was applied to the determination of chlorine dioxide in synthetic samples and real samples, with satisfactory results. This method has good selectivity, especially, other chlorine species such as chlorine, hypochlorite, chlorite and chlorate do not interfere the determination. The mechanism of fluorescence reduction was also considered.  相似文献   

19.
A novel enzyme reactor with co-immobilization of β-galactosidase and glucose oxidase in calcium alginate fiber (CAF) and amine modified nanosized mesoporous silica (AMNMS) was prepared which incorporate the adsorption and catalysis of AMNMS with the cage effect of the polymer to increase catalytic activity and stability of immobilized enzyme. The enzyme reactor was applied to prepare a chemiluminescence (CL) flow-through biosensor for determination of lactose combined with a novel luminol-diperiodatonickelate (DPN) CL system we reported. It shows that the CL flow-through biosensor possesses long lifetime, high stability, high catalytic activity and sensitivity. The relative CL intensity was linear with the lactose concentration in the range of 8 × 10−8-4 × 10−6 g mL−1 with the detection limit of 2.7 × 10−8 g mL−1 (3σ). It has been successfully applied to the determination of lactose in milk.  相似文献   

20.
In this work, a stable electrogenerated chemiluminescence (ECL) detector was developed. The detector was prepared by packing cation-exchanged resin particles in a glass tube, followed by inserting Pt wires (working electrode) in this tube and sealing. The leakage of Ru(bpy)32+ can be compensated by adding a small amount of Ru(bpy)32+ into solution phase. Coupled with high-performance liquid chromatography separation, the detector has been used for determination of itopride hydrochloride in human serum. Under the optimal conditions, the ECL intensity has a linear relationship with the concentration of itopride hydrochloride in the range of 1.0 × 10−8 g mL−1 to 1.0 × 10−6 g mL−1 and the detection limit was 3 × 10−9 g mL−1 (S/N = 3). The as-prepared ECL detector displayed good sensitivity and stability.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号