共查询到20条相似文献,搜索用时 13 毫秒
1.
In this study, a new polymeric ionic liquid-based adsorbent was prepared and used as the extraction medium of stir cake sorptive extraction (SCSE) of three organic acid preservatives, namely, p-hydroxybenzoic acid, sorbic acid and cinnamic acid. The adsorbent was synthesized by the copolymerization of 1-ally-3-vinylimidazolium chloride (AV) and divinylbenzene (DVB) in the presence of a porogen solvent containing 1-propanol and 1,4-butanediol. The effect of the content of monomer and the porogen solvent in the polymerization mixture on the extraction performance was investigated thoroughly. The adsorbent was characterized by infrared spectroscopy, elemental analysis, scanning electron microscopy and mercury intrusion porosimetry. To obtain the optimal extraction conditions of SCSE/AVDVB for target analytes, key parameters including desorption solvent, adsorption and desorption time, ionic strength and pH value in sample matrix were studied in detail. The results showed that under the optimized conditions, the SCSE/AVDVB could extract the preservatives effectively through multiply interactions. At the same time, a simple and sensitive method by combining SCSE/AVDVB and high-performance liquid chromatography with diode array detection was developed for the simultaneous analysis of the target preservatives in orange juices and tea drinks. Low limits of detection (S/N = 3) and quantification limits (S/N = 10) of the proposed method for the target analytes were achieved within the range of 0.012–0.23 μg/L and 0.039–0.42 μg/L, respectively. The precision of the proposed method was evaluated in terms of intra- and inter-assay variability calculated as relative standard deviation (RSD), and it was found that the values were all below 10%. Finally, the proposed method was used to detect preservatives in different orange juice and tea drink samples successfully. The recoveries were in the range of 71.9–116%, and the RSDs were below 10% in the all cases. 相似文献
2.
Determination of fluoroquinolones in environmental water and milk samples treated with stir cake sorptive extraction based on a boron‐rich monolith 下载免费PDF全文
In this study, a new stir cake sorptive extraction using a boron‐rich monolith as the adsorbent was prepared by the in situ copolymerization of vinylboronic anhydride pyridine complex and divinylbenzene. The effect of preparation parameters, including the ratio of vinylboronic anhydride pyridine complex and divinylbenzene, monomer mixture, and porogen solvent, on extraction performance was investigated thoroughly. The physicochemical properties of the adsorbent were characterized by infrared spectroscopy, scanning electron microscopy, and mercury intrusion porosimetry. Several conditions affecting the extraction efficiency were investigated in detail. Under the optimized conditions, a convenient and sensitive method for the determination of trace fluoroquinolones residues in water and milk samples was established by coupling stir cake sorptive extraction with high‐performance liquid chromatography and diode array detection. The limits of detection for the target compounds were 0.10–0.26 and 0.11–0.22 μg/L for water and milk samples, respectively. In addition, the developed method showed good linearity, repeatability, and precision. Finally, the proposed method was successfully applied for the detection of trace fluoroquinolones residues in environmental water and milk samples. Satisfactory recoveries were obtained for the determination of fluoroquinolones in spiking samples that ranged from 68.8 to 120%, with relative standard deviations below 10% in all cases. 相似文献
3.
Evaluation of a method for the simultaneous quantification of N‐nitrosamines in water samples based on stir bar sorptive extraction combined with high‐performance liquid chromatography and diode array detection 下载免费PDF全文
Zahra Talebpour Simindokht Rostami Hassan Rezadoost 《Journal of separation science》2015,38(9):1601-1609
A simple, sensitive, and reliable procedure based on stir bar sorptive extraction coupled with high‐performance liquid chromatography was applied to simultaneously extract and determine three semipolar nitrosamines including N‐nitrosodibutylamine, N‐nitrosodiphenylamine, and N‐nitrosodicyclohexylamine. To achieve the optimum conditions, the effective parameters on the extraction efficiency including desorption solvent and time, ionic strength of sample, extraction time, and sample volume were systematically investigated. The optimized extraction procedure was carried out by stir bars coated with polydimethylsiloxane. Under optimum extraction conditions, the performance of the proposed method was studied. The linear dynamic range was obtained in the range of 0.95–1000 ng/mL (r = 0.9995), 0.26–1000 ng/mL (r = 0.9988) and both 0.32–100 ng/mL (r = 0.9999) and 100–1000 ng/mL (r = 0.9998) with limits of detection of 0.28, 0.08, and 0.09 ng/mL for N‐nitrosodibutylamine, N‐nitrosodiphenylamine, and N‐nitrosodicyclohexylamine, respectively. The average recoveries were obtained >81%, and the reproducibility of the proposed method presented as intra‐ and interday precision were also found with a relative standard deviation <6%. Finally, the proposed method was successfully applied to the determination of trace amounts of selected nitrosamines in various water and wastewater samples and the obtained results were confirmed using mass spectrometry. 相似文献
4.
An organic-inorganic hybrid titania-hydroxy-terminated silicone oil (titania-OH-TSO) stir bar coating was prepared by sol-gel method. The extraction performance of titania-OH-TSO coated stir bar was evaluated and compared with poly(dimethysiloxane) (PDMS), poly(dimethysiloxane)-divinylbenzene (PDMS-DVB), poly(dimethysiloxane)-β-cyclodextrin (PDMS-β-CD) and C(18) coated stir bar with five polar drugs of abuse including amphetamine (PA), methamphetamine (MA), 3,4-methylenedioxyamphetamine (MDA), 3,4-methylenedioxymethamphetamine (MDMA) and ketamine (Ke) as the model analytes. The experimental results revealed that the titania-OH-TSO coated stir bar exhibited highly pH-resistant ability, good preparation reproducibility, superior selectivity and high extraction efficiency for the target compounds. Based on this fact, a new method of titania-OH-TSO coated stir bar sorptive extraction (SBSE) combined with high performance liquid chromatography (HPLC)-ultraviolet visible (UV) detection was developed for the analysis of five drugs of abuse in urine samples. The factors affecting the extraction efficiency of SBSE such as sample pH, desorption solvent, sample volume, extraction time, desorption time, stirring rate and ionic strength were investigated and the optimal extraction conditions were established. Under the optimized conditions, the limits of detection (LODs) for titania-OH-TSO coated SBSE-HPLC-UV determination of five polar drugs of abuse were in the range of 2.3-9.1 μg/L with relative standard deviations (RSDs) ranging from 7.3 to 8.9% (c=300 μg/L, n=6), and all of the target compounds exhibited good linearity over a concentration range of 30-3000 μg/L. The developed method was applied to the determination of amphetamines and Ke in urine samples of drug abusers with satisfactory results. 相似文献
5.
A sensitive and precise stir bar sorptive extraction (SBSE) combined with LC (SBSE/LC) analysis is described for simultaneous determination of methyl, ethyl, propyl, and butyl parabens in commercial cosmetic products in agreement with the European Union Cosmetics Directive 76/768/EEC. Important factors in the optimization of SBSE efficiency are discussed, such as time and temperature of extraction, pH, and ionic strength of the sample, matrix effects, and liquid desorption conditions by different modes (magnetic stirring, ultrasonic). The LOQs of the SBSE/LC method ranged from 30 to 200 ng/mg, with linear response over a dynamic range, from the LOQ to 2.5 μg/mg, with a coefficient of determination higher than 0.993. The interday precision of the SBSE/LC method presented a coefficient of variation lower than 5%. The effectiveness of the proposed method was proven for analysis of commercial cosmetic products such as body creams, antiperspirant creams, and sunscreens. 相似文献
6.
分子印迹聚合物为涂层的吸附萃取搅拌棒在环境水样双酚A含量测定中的应用 总被引:4,自引:0,他引:4
以双酚A(BPA)为单体,利用整体材料“原位”聚合技术制备以分子印迹聚合物为涂层的吸附萃取搅拌棒(MIP-SBSE),然后与高效液相色谱(HPLC)-二极管阵列检测器联用,探讨其对环境水样BPA的选择萃取性能。优化萃取过程中吸附和解吸时间、解吸液种类以及基底pH值和离子强度对目标化合物的选择吸附性能。在最佳条件下,MIP-SBSE可对模板分子进行有效的选择吸附,线性范围为1.0~200 μg/L,检出限(S/N=3)和定量限(S/N=10)分别为0.28μg/L和0.94 μg/L。在实际水样分析中,具有良好的加标回收率,其值为96.0%~108.7%。研究结果表明,所建立的方法具有简便、灵敏和环境友好等特点。 相似文献
7.
A new polymeric coating consisting of a dual-phase, polydimethylsiloxane (PDMS) and polypyrrole (PPY) was developed for the stir bar sorptive extraction (SBSE) of antidepressants (mirtazapine, citalopram, paroxetine, duloxetine, fluoxetine and sertraline) from plasma samples, followed by liquid chromatography analysis (SBSE/LC-UV). The extractions were based on both adsorption (PPY) and sorption (PDMS) mechanisms. SBSE variables, such as extraction time, temperature, pH of the matrix, and desorption time were optimized, in order to achieve suitable analytical sensitivity in a short time period. The PDMS/PPY coated stir bar showed high extraction efficiency (sensitivity and selectivity) toward the target analytes. The quantification limits (LOQ) of the SBSE/LC-UV method ranged from 20 ng mL−1 to 50 ng mL−1, and the linear range was from LOQ to 500 ng mL−1, with a determination coefficient higher than 0.99. The inter-day precision of the SBSE/LC-UV method presented a variation coefficient lower than 15%. The efficiency of the SBSE/LC-UV method was proved by analysis of plasma samples from elderly depressed patients. 相似文献
8.
Natalia Campillo Pilar ViñasNerea Aguinaga Gema FérezManuel Hernández-Córdoba 《Journal of chromatography. A》2010,1217(27):4529-4534
A stir bar microextraction (SBSE) procedure for the determination of seven strobilurin fungicides in fruit samples using liquid chromatography (LC) and diode array detection (DAD) has been developed. The samples were sonicated in the presence of ethanol before submitting the extracts to SBSE. The incorporation of drazoxolon as an internal standard before SBSE allowed calibration without the need to use the standard additions method. Under the optimized conditions, detection limits were in the 0.3–2 ng g−1 range, corresponding to trifloxystrobin and metominostrobin, respectively. The SBSE–LC–DAD procedure showed good repeatability (RSD below 11% in all cases) and provided recoveries of 80–105% from spiked samples. The method was applied to fifteen fruit samples, and low levels of pyraclostrobin and trifloxystrobin were found in two of them. 相似文献
9.
基于整体材料搅拌棒固相萃取高效液相色谱联用测定饲料和水样中硝基呋喃类药物残留 总被引:1,自引:0,他引:1
利用自制的以聚(乙烯基咪唑-二乙烯基苯)(VIDB)整体材料为涂层的固相萃取搅拌棒(VIDB-SBSE)萃取3种硝基呋喃类药物,然后与高效液相色谱-二极管阵列检测器联用建立了测定饲料和水样品中硝基呋喃类药物残留的方法。详细考察了萃取过程中萃取和解吸时间、样品基质的pH值以及离子强度等实验条件对萃取效率的影响。在最佳条件下,呋喃唑酮的线性范围为0.5~200μg/L,呋喃妥因和呋喃西林的线性范围为0.25~200μg/L,3种目标物的检出限(LO D)(S/N=3)在0.068~0.11μg/L之间,所建方法具有理想的日内和日间重现性(R SD值均小于6%)。在对饲料和实际水样的测定中,不同加标浓度呋喃唑酮、呋喃妥因和呋喃西林的回收率在80.6%~108%之间。研究表明,所建立的方法具有简便、灵敏、环境友好等特点。 相似文献
10.
Supported liquid membrane (SLM) and solid phase extraction (SPE) have been applied as clean-up and/or enrichment techniques for a mixture of five benzimidazole anthelmintics compounds, namely albendazole, fenbendazole, mebendazole, oxibendazole, and thiabendazole. Two biological matrices, mainly urine and milk, and ultra high purity (UHP) water were spiked with a mixture of these five compounds. Waters Oasis® MCX and International Sorbent Technology (IST) HCX SPE sorbents were used. The liquid membrane used for clean-up and/or enrichment of these compounds was 5% tri-n-octylphosphine oxide (TOPO) dissolved in n-undecane/di-n-hexyl ether (1:1). The SLM extraction efficiencies and SPE percentage recoveries ranged between 60 and 100%. The detection limits (DLs) for different benzimidazole compounds by SPE/LC-ES-MS for thiabendazole, oxibendazole, and albendazole was 0.1 ng/L, for fenbendazole and mebendazole was 1 and 10 ng/L, respectively. Similarly, the detection limits of SLM/LC-ES-MS for thiabendazole, oxibendazole, and albendazole was 0.1 ng/L and for fenbendazole and mebendazole was 1 ng/L. The results of optimization of various parameters of the SLM method are reported. 相似文献
11.
A novel sulfamethazine molecularly imprinted polymer (MIP)-coated stir bar for sorptive extraction of eight sulfa drugs from biological samples was prepared. The MIP-coating was about 20 μm thickness with the relative standard deviation (RSD) of 6.7% (n = 10). It was characterized by scanning electron microscope, infrared spectrum, thermogravimetric analysis, and solvent-resistant investigation, respectively. The non-imprinted polymer (NIP)-coating was used for comparison. The adsorptive capacity and selectivity of MIP-coating were evaluated in detail. The MIP-coating showed higher adsorption capability and selectivity than the NIP-coating. The saturated adsorption amount of the MIP-coating was 4.6 times over that of the NIP-coating in toluene. Sulfamethazine could be detected after the MIP-coated stir bar sorptive extraction even at a low concentration of 0.2 μg/L. The MIP-coating also exhibited selective adsorption ability to analogues of the template. A method for the determination of eight sulfa drugs in biological samples by MIP coated stir bar sorptive extraction coupled with high performance liquid chromatography (HPLC) was developed. The extraction conditions, including extraction solvent, extraction time, desorption solvent, desorption time and stirring speed, were optimized. The linear ranges were 1.0-100 μg/L and 2.0-100 μg/L for eight sulfonamides, respectively. The detection limits were within the range of 0.20-0.72 μg/L. The method was successfully applied to simultaneous multi-residue analysis of eight sulfonamides in spiked pork, liver and chicken samples with the satisfactory recoveries. 相似文献
12.
Xiaojia Huang Ningning QiuDongxing Yuan Qingmei Lin 《Journal of chromatography. A》2010,1217(16):2667-2673
In this study, a novel mixed mode monolithic material was prepared and acted as the SBSE coating. The monolithic material was prepared by in situ copolymerization of methacrylic acid-3-sulfopropyl ester potassium salt (MASE) and divinylbenzene (DB) in the presence of a porogen solvent containing cyclohexanol, 1-dodecanol, and water with azobisisobutyronitrile as initiator. The influences of the contents of the porogen solvent and monomer in the polymerization mixture on the extraction performance were investigated thoroughly. Several characteristic techniques, such as elemental analysis, scanning electron microscopy and infrared spectroscopy were used to characterize the monolithic material. To achieve optimum extraction performance for quinolones, several parameters, including pH value, desorption solvent, ionic strength in sample matrix, extraction and desorption time were investigated. The results show that under the optimized experimental conditions, the method has good sensitivity, linearity, simplicity and low cost. The extraction performance of present method to the target compounds was compared with commercial SBSE which using polydimethylsiloxane as coating and other SBSEs which based on monolithic materials. The comparative results indicate that present SBSE can extract the analytes more effectively than other SBSEs because both ion-exchange and hydrophobic interactions contribute to the extraction of quinolones. 相似文献
13.
Xiaojia Huang Ningning QiuDongxing Yuan Qingmei Lin 《Journal of chromatography. A》2009,1216(20):4354-4360
A simple and sensitive method for the determination of polar aromatic amines (PAAs) was developed using stir bar sorptive extraction (SBSE) coupling to high-performance liquid chromatography. A hydrophilic poly(vinylimidazole-divinylbenzene) (VIDB) monolithic material was prepared and acted as SBSE coating. The influences of polymerization conditions for VIDB on the extraction efficiency were investigated using aniline and 2,4-dinitroaniline as detected solutes. To achieve optimum extraction performance for PAAs, several parameters including extraction and desorption time, desorption solvent, ionic strength and pH value of sample matrix were investigated. The results showed that under the optimized experimental conditions, the method showed good sensitivity and excellent recoveries, as well as advantages such as linearity, simplicity, low cost and high feasibility. The extraction performance of present method to the target compounds also compared with commercial SBSE which using polydimethylsiloxane as coating and other SBSE which based on monolithic materials. Finally, the proposed method was successfully applied to the determination of PAAs in lake and sea waters, and excellent recoveries of spiked target compounds in real samples were obtained. 相似文献
14.
Xiaojia Huang Linli Chen Meng Chen Dongxing Yuan Shuyu Nong 《Journal of separation science》2013,36(5):907-915
In the present study, a convenient and sensitive method for determination of six penicillin antibiotics (amoxicillin, ampicillin, penicillin G, oxacillin, cloxacillin, and dicloxacillin) in milk and honey samples was developed. Milk and honey samples were diluted with water, then directly treated by stir bar sorptive extraction based on poly (vinylimidazole‐divinylbenzene) monolithic material as coating. The analytes were analyzed by LC/ESI‐ MS/MS. Several extraction parameters including extraction and desorption time, pH value, and ionic strength in sample matrix were investigated in detail. Under the optimized extraction conditions, the calculated detection limits for the target compounds were as low as 0.23–2.66 ng/kg in milk and 0.18–1.42 ng/kg in honey, respectively. Good linearity was obtained for analytes with the correlation coefficients (R2) above 0.997. Excellent method reproducibility was achieved in terms of intraday and interday precisions, indicated by the RSDs of <5.0 and <10.0%, respectively. Finally, the proposed method was successfully applied to the determination of penicillin antibiotics residues in different milk and honey samples. 相似文献
15.
In this report, vinylimidazolium ionic liquid as a functional monomer for preparation of chlorsulfuron (CS) imprinted polymers were first studied. The imprinted materials showed high selectivity for CS, and fast kinetics so that adsorption equilibrium was achieved within 5 min. These materials have been further employed to detect trace CS from water samples by online preconcentration coupled with HPLC. The sorbent offered good linearity (0.005-30 μg L(-1), r(2)>0.99) for on-line solid-phase extraction of trace chlorsulfuron. Under the optimal experimental conditions, the recovery for chlorsulfuron was in the range of 81.0-110.1% for the water samples, with RSDs ranging from 1.2 to 7.6%. 相似文献
16.
A method for determining 68 pesticides in river water using stir bar sorptive extraction (SBSE)-thermal desorption (TD)-gas chromatography-mass spectrometry (GC-MS) is described. SBSE sampling was optimized for sample solution pH, salting-out and methanol addition. Although salting-out enhanced the ability of the method to extract most of the pesticides with low absolute recoveries, the absolute recoveries of four pesticides were not improved by salting-out. The detection limits of the method for the pesticides ranged from 0.2 to 20 ng/l. Analyte recoveries from a river water sample spiked with standards at 10 and 100 ng/l were 58.5–132.0% (RSD: 1.8–15.8%) and 61.0–121.3% (RSD: 1.4–20.2%), respectively. 相似文献
17.
A temperature-controlled ionic liquid dispersive liquid-phase microextraction in combination with high performance liquid chromatography was developed for the enrichment and determination of triazine herbicides such as cyanazine,simazine,and atrazine in water samples.1-Octyl-3-methylimidazolium hexafluorophosphate([C8MIM][PF6]) was selected as the extraction solvent.Several experimental parameters were optimized.Under the optimal conditions,the linear range for cyanazine was in the concentration range of 0.5–80 mg/L and the linear range for simazine and atrazine was in the range of1.0–100 mg/L.The limit of detection(LOD,S/N = 3) was in the ranges of 0.05–0.06 mg/L,and the intra day and inter day precision(RSDs,n = 6) was in the ranges of 3.2%–6.6% and 4.8%–8.9%,respectively.Four real water samples were analyzed with the developed method,and the experimental results showed that the spiked recoveries were satisfactory.All these exhibited that the developed method was a valuable tool for monitoring such pollutants. 相似文献
18.
Viñas P Campillo N Hernández-Pérez M Hernández-Córdoba M 《Analytica chimica acta》2008,611(1):119-125
A comparison of direct immersion solid-phase microextraction (DI-SPME) and stir bar sorptive extraction (SBSE) coupled to liquid chromatography (HPLC) with fluorimetric detection for the rapid analysis of resveratrol isomers is described. For DI-SPME, a polar Carbowax-template resin (CW/TPR) 50 μm fiber was the most efficient and optimum extraction conditions were 40 °C and an extraction time of 30 min, stirring in the presence of 5% (m/v) sodium chloride and 0.07 M acetate/acetic acid buffer (pH 6). Desorption was carried out using the static mode for 10 min. Linearity was obtained in the 5-150 and 2-150 ng mL−1 ranges for trans- and cis-resveratrol, with detection limits of 2 and 0.5 ng mL−1, respectively. When using SBSE, a polydimethylsiloxane (PDMS) twister provided best extraction by means of a derivatization reaction in the presence of acetic anhydride and potassium carbonate. The same time and temperature were used for the extraction step in the presence of 2.5% (m/v) sodium chloride, and liquid desorption was performed with 150 μL of a 50/50 (v/v) acetonitrile/1% (v/v) acetic acid solution in a desorption time of 15 min. Linearity was now between 0.5 and 50 ng mL−1 for trans-resveratrol with a detection limit of 0.1 ng mL−1, while cis-resveratrol could not be extracted. The proposed methods were successfully applied to determining the resveratrol isomer content of wine, must and fruit juices. 相似文献
19.
Alvarez-Avilés O Cuadra-Rodríguez L González-Illán F Quiñones-González J Rosario O 《Analytica chimica acta》2007,597(2):273-281
A practical analytical methodology based on coupling microwave-assisted extraction-stir bar sorptive extraction-thermal desorption-gas chromatography-mass spectrometry (MAE-SBSE-TD-GC-MS) was developed and validated for the characterization of several SVOC in atmospheric particulate matter (PM).The high enrichment capacity of SBSE makes it a powerful tool for improving detection limits and MAE has been useful for overcoming the long extraction times and high volumes of extraction solvent used in traditional methodologies. Relative to Soxhlet extraction followed by GC-MS analysis (EPA Methods 3540 and 8270C), the MAE-SBSE-TD-GC-MS methodology resulted with approximately 104 times better detection limits. Detection limits ranged from 0.3 to 8.3 pg m−3 for pp′-DDD and decachlorobyphenyl, respectively in PM2.5, 24 m3 air sample. The performance of the optimized methodology gave good precisions, with R.S.D. less than 30% for most of the standards, and linearity within the range tested of 0.1-15 μg L−1. Analysis of real PM samples resulted in the identification of compounds in the ng L−1 range. 相似文献
20.
Development and application of a polar coating for stir bar sorptive extraction of emerging pollutants from environmental water samples 总被引:1,自引:0,他引:1
In the present study, a stir bar coated with hydrophilic polymer based on poly(N-vinylpyrrolidone-co-divinylbenzene) was prepared for the sorptive extraction of polar compounds. The main parameters affecting the polymerisation of the coating were investigated.The new stir bar was applied successfully in stir bar sorptive extraction with liquid desorption followed by liquid chromatography–mass spectrometry in tandem with a triple quadrupole for the determination of a group of polar pharmaceuticals and personal care products (PPCPs) in environmental water matrices. Different variables affecting extraction and desorption such as agitation speed, temperature, ionic strength and extraction time were optimised. The results showed that the stir bar is able to enrich the selected analytes effectively.The developed method was applied to determine a group of PPCPs in different complex environmental samples, including river, effluent and influent waste water. 相似文献