共查询到20条相似文献,搜索用时 15 毫秒
1.
Sirkku E. Jäntti Minna Hartonen Mika Hilvo Heli Nygren Tuulia Hyötyläinen Raimo A. Ketola Risto Kostiainen 《Analytica chimica acta》2013
An ultra performance liquid chromatography–electrospray ionization-tandem mass spectrometry (UPLC–MS/MS) method was developed for the analysis of steroids and their glucuronides in urine samples. The method provides high sensitivity and fast analysis, as both steroids and their glucuronides can be analyzed directly without hydrolysis or complex sample preparation. The method was applied in profiling of targeted and nontargeted steroids and steroid glucuronides during pregnancy. The concentrations of 11 of 27 targeted steroids and steroid glucuronides and the concentrations of 25 nontargeted steroid glucuronides increased about 10–400 fold during the pregnancy. The concentrations of most of these 36 compounds began to increase in the first days of the pregnancy, increased gradually during the pregnancy, achieved a maximum in late pregnancy, and decreased sharply after delivery. Exceptionally, the concentrations of allopregnanolone and 17-hydroxypregnenolone started to increase later than those of the other steroids. Moreover, the concentrations of E2 glucuronides began to decrease one week before the delivery, in contrast to most of the steroids and steroid glucuronides, whose concentrations dropped sharply during the delivery. Concentrations of 34 compounds decreased noticeably when the subject was on sick leave owing a series of painful contractions. The results suggest that steroids and especially steroid glucuronides may provide a valuable diagnostic tool to follow the course of pregnancy. 相似文献
2.
N. Sánchez-Ávila J.M. Mata-Granados J. Ruiz-Jiménez M.D. Luque de Castro 《Journal of chromatography. A》2009,1216(40):6864-6872
A method for the determination of fatty acids in serum based on GC–MS (micro-SIS detection mode) has been developed and the separation and cis/trans isomers have been identified. A prior two-step extraction/derivatization procedure accelerated by ultrasound allows individual determination of esterified (EFAs) and non-esterified fatty acids (NEFAs), and shortening of the derivatization steps to 5 min for EFAs and 15 min for NEFAs. The total analysis time for 39 fatty acids was 61 min. The minimum LOD and LOQ values were 0.002 and 0.006 μg/ml, respectively. The proposed method was validated for EFAs and NEFAs using two different methods and the results show no statistical differences between the proposed method and those used as reference. The proposed derivatization–extraction methodology is suitable for fatty-acid analysis of human serum, and can be applied to nutritional and epidemiological studies. 相似文献
3.
A simple and sensitive liquid chromatography–tandem mass spectrometry (LC–MS/MS) method has been developed and validated for the determination of fingolimod in human blood. The analyte and internal standard fingolimod-d4 were extracted from 300 μl of human blood using protein precipitation coupled with solid-phase extraction method. The chromatographic separation was achieved with a Kinetex biphenyl column (100 × 4.6 mm, 2.6 μm) under isocratic conditions at the flow rate of 0.8 ml/min and column temperature was maintained at 45°C. The detection of analyte and internal standard was carried out by tandem mass spectrometry, operated in positive ion and multiple reaction monitoring acquisition mode. The method was fully validated for its selectivity, precision, accuracy, linearity, stability, detection and quantification limit. The extraction recovery of fingolimod in human blood ranged from 98.39 to 99.54%. The developed method was linear over the concentration range of 5–2500 pg/ml with a detection limit of 1 pg/ml. The developed method was validated and successfully applied for pharmacokinetic study after oral administration of fingolimod capsules. 相似文献
4.
Thompson RQ Phinney KW Welch MJ White E 《Analytical and bioanalytical chemistry》2005,381(7):1441-1451
Eight naturally occurring capsaicinoids have been determined in Capsicum by use of high-purity standards, with norcapsaicin as an internal standard. The solid standards were rigorously checked for purity. The sensitivity of electrospray ionization (ESI), atmospheric-pressure chemical ionization (APCI), and coordination ion-spray (CIS; with silver) toward the capsaicinoids were measured and compared. The highest sensitivity was found for positive-ion ESI. Method validation of the liquid chromatography–ESI-mass spectrometry (LC–ESI-MS) determination is reported, including tests for repeatability (4%), detection limit (5 pg injected), linear range (20–6 ng injected), quantitation (excellent linearity; <2% relative standard deviation), and recovery (99–103%). The major and minor capsaicinoids in a commercial plant extract and in chili pepper fruits were quantified.Electronic Supplementary Material Supplementary material is available for this article at 相似文献
5.
A method based on capillary liquid chromatography combined with electrospray ionization-tandem mass spectrometry (CapLC–ESI-MS–MS) for the detection and identification of casein deriving peptides in fined white wine is described. This is the first step towards the development of a liquid chromatography mass spectrometric method for the detection/identification of markers of potentially allergenic milk proteins used as wine fining agents. The method demonstrated to be capable of detecting some peptides arising from α and β casein (with the relative aminoacidic sequences elucidated) in extracts of white wine fined with casein at 100 and 1000 μg/mL. This MS based approach appears to be a useful tool for screening purposes as well as a confirmatory tool for the unequivocal identification of caseins in ELISA positive samples. 相似文献
6.
Shangfu Li Yibao Jin Zhi Tang Shuhai Lin Hongxia Liu Yuyang Jiang Zongwei Cai 《Analytica chimica acta》2015
Ribonucleosides are the end products of RNA metabolism. These metabolites, especially the modified ribonucleosides, have been extensively evaluated as cancer-related biomarkers. However, the determination of urinary ribonucleosides is still a challenge due to their low abundance, high polarity and serious matrix interferences in urine samples. In this study, a derivatization method based on a chemical reaction between ribonucleosides and acetone to form acetonides was developed for the determination of urinary ribonucleosides. The derivative products, acetonides, were detected by using liquid chromatography–tandem mass spectrometry (LC–MS/MS). The methodological evaluation was performed by quantifying four nucleosides for linear range, average recovery, precision, accuracy and stability. The validated procedures were applied to screen modified ribonucleosides in urine samples. Improvement of separation and enhancement of sensitivity were obtained in the analysis. To identify ribonucleosides, inexpensive isotope labeling acetone (acetone-d6) and label-free acetone were applied to form ordinary and deuterated acetonides, respectively. The two groups of samples were separated with orthogonal partial least squares (OPLS). The ordinary and deuterated pairs of acetonides were symmetrically distributed in the S-plot for easy and visual signal identification. After structural confirmation, a total of 56 ribonucleosides were detected, 52 of which were modified ribonucleosides. The application of derivatization, deuterium-labeling and multivariate statistical analysis offers a new option for selective detection of ribonucleosides in biological samples. 相似文献
7.
8.
Four different organic solvents: dimethylformamide, 1,4-dioxane, n-propanol and ethanol were evaluated as alternative organic modifiers to acetonitrile for liquid chromatography (LC) separations. The aim was to establish common sets of chromatographic conditions that could be applied for LC hyphenation to inductively coupled plasma mass spectrometry (ICPMS) as well as to electrospray ionization MS (ESIMS). The approach was to evaluate candidate solvents that, compared to acetonitrile, potentially could give improved analytical performance (low solvent vapor loading, maximized analyte sensitivity and minimized carbon depositions on instrumental parts) in ICPMS analysis while retaining chromatographic and ESIMS performances. The study showed that dimethylformamide, 1,4-dioxane, n-propanol and ethanol all can be advantageous chromatographic modifiers for LC–ICPMS analysis, giving superior performance compared to acetonitrile. For the combined use of LC–ICPMS and LC–ESIMS with a common set of chromatographic conditions, n-propanol gave the best overall performance. The 195Pt+ signal in ICPMS was continuously monitored during a 0–60% organic solvent gradient and at 25% of organic modifier, 100% of the signal obtained at the gradient start was preserved for n-propanol compared to only 35% of the signal when using acetonitrile. Platinum detection limits were 5–8 times lower using n-propanol compared with acetonitrile. Signal-to-noise ratio in continuous ESIMS signal measurements was 100, 90 and 110 for a 100 μg/ml solution of leucine–enkephaline using acetonitrile, ethanol and n-propanol, respectively. Chromatographic efficiency in reversed phase separations was preserved for n-propanol compared to acetonitrile for the analysis of the whole protein cytochrome C and the peptide bacitracin on a column with particle and pore sizes of 5 μm and 300 Å, but slightly deteriorated for the separation of the peptides leucine–enkephaline and bacitracin on a 3 μm and 90 Å column as the peak width at half height for both peptides increased by a factor of two. The performance on the smaller dimensioned column could however be improved by running the separations at 40 °C. 相似文献
9.
Carla Nicolucci Sergio Rossi Ciro Menale Emanuele Miraglia del Giudice Laura Perrone Pasquale Gallo Damiano G. Mita Nadia Diano 《Analytical and bioanalytical chemistry》2013,405(28):9139-9148
A selective and highly sensitive liquid chromatography–tandem mass spectrometry method has been developed and validated for determination of Bisphenol A (BPA) in human urine using labeled d6-BPA as internal standard. BPA was purified from human urine by affinity chromatography on solid extraction AFFINIMIP® Bisphenol A cartridges, based on molecularly imprinted polymers. After purification, the samples were analyzed on a Phenomenex Kinetex 100?×?4.6 mm, 2.6 μm particle PFP reversed-phase HPLC column, coupled to a triple quadrupole mass spectrometer by an electrospray ion source. Analyses were performed in the multiple reaction monitoring mode and negative ionization; the product ions at 133.2 and 212.1?m/z for BPA and at 138.2 and 215.0?m/z for d6-BPA were monitored to assess unambiguous identification. The linearity of the detector response was verified in human urine over the concentration range 0.100–200 ng/mL. The detection limit was calculated as 0.03 ng/mL and the limit of quantification of the method is 0.10 ng/mL. This LC/ESI-MS/MS method was in-house validated evaluating specificity, trueness, within-day and between-days precision. The mean recoveries of BPA from spiked urine samples were higher than 94 % and good reproducibility (relative standard deviations?≤?8.1 %) was observed. The developed method was applied to a pilot study involving 105 children, aged from 6 to 14 years (16 normal weight and 89 obese children), from the Regione Campania (Southern Italy). The aim of this study was to determine the concentrations of BPA in urine of children and possible correlations with childhood obesity. 相似文献
10.
Ethan H. McIlhenny Kelly E. Pipkin Leanna J. Standish Hope A. Wechkin Rick Strassman Steven A. Barker 《Journal of chromatography. A》2009,1216(51):8960-8968
A direct injection/liquid chromatography–electrospray ionization-tandem mass spectrometry procedure has been developed for the simultaneous quantitation of 11 compounds potentially found in the increasingly popular Amazonian botanical medicine and religious sacrament ayahuasca. The method utilizes a deuterated internal standard for quantitation and affords rapid detection of the alkaloids by a simple dilution assay, requiring no extraction procedures. Further, the method demonstrates a high degree of specificity for the compounds in question, as well as low limits of detection and quantitation despite using samples for analysis that had been diluted up to 200:1. This approach also appears to eliminate potential matrix effects. Method bias for each compound, examined over a range of concentrations, was also determined as was inter- and intra-assay variation. Its application to the analysis of three different ayahuasca preparations is also described. This method should prove useful in the study of ayahuasca in clinical and ethnobotanical research as well as in forensic examinations of ayahuasca preparations. 相似文献
11.
A liquid chromatography–electrospray-tandem mass spectrometry (ES-MS/MS) method was developed for the speciation analysis of four organic selenium species of relevance to human urinary metabolism, namely trimethylselenomium ion (TMSe+), selenomethionine (SeMet) and the two selenosugars, methyl 2-acetamido-2-deoxy-1-seleno-β-d-galactos/-glucos-amine (SeGalNAc and SeGluNAc, respectively). Their chromatographic separation was achieved by using a cation exchange pre-column coupled in-series with a reversed-phase high-performance liquid chromatography column, along with an isocratic mobile phase. Online detection was performed using ES-MS/MS in selective reaction monitoring mode. SeGalNAc was detected as the major human urinary metabolite of selenium in the samples analysed, whereas TMSe+ was detected in the urine of one volunteer before and after receiving a selenium supplement. SeMet was not detected as a urine excretory metabolite in this study. Spiking experiments performed with the urine samples revealed significant signal suppression caused by coeluting matrix constituents. To overcome such interferences, isotopically labelled 13CD382SeGalNAc was used as an internal standard, whereas in the absence of an isotopically labelled internal standard for TMSe+, the standard addition method was applied. Quality control for the accurate quantitation of TMSe+ and SeGalNAc was carried out by analysing spiked human urine samples with appropriate selenium standards over a concentration range of 10–50 μg Se L−1. The method has achieved a limit of detection in the presence of urine matrix comparable to that of HPLC-inductively coupled plasma-mass spectrometry for the four selenium species: 1.0 μg Se L−1 for TMSe+, 5.6 μg Se L−1 for SeMet, and 0.1 μg Se L−1 for both SeGalNAc and SeGluNAc. 相似文献
12.
Fuyou Du Lin Sun Xian Zhen Honggang Nie Yanjie Zheng Guihua Ruan Jianping Li 《Analytical and bioanalytical chemistry》2015,407(20):6071-6079
High-internal-phase-emulsion polymers (polyHIPEs) show great promise as solid-phase-extraction (SPE) materials because of the tremendous porosity and highly interconnected framework afforded by the high-internal-phase-emulsion (HIPE) technique. In this work, polyHIPE monolithic columns as novel SPE materials were prepared and applied to trace enrichment of cytokinins (CKs) from complex plant samples. The polyHIPE monoliths were synthesized via the in-situ polymerization of the continuous phase of a HIPE containing styrene (STY) and divinylbenzene (DVB) in a stainless column, and revealed highly efficient and selective enrichment ability for aromatic compounds. Under the optimized experimental conditions, a method using a monolithic polyHIPE column combined with liquid chromatography–electrospray tandem mass spectrometry (LC–MS–MS) was developed for the simultaneous extraction and sensitive determination of trans-zeatin (tZ), meta-topolin (mT), kinetin (K), and kinetin riboside (KR). The proposed method had good linearity, with correlation coefficients (R 2) from 0.9957 to 0.9984, and low detection limits (LODs, S/N?=?3) in the range 2.4–47 pg mL?1 for the four CKs. The method was successfully applied to the determination of CKs in real plant samples, and obtained good recoveries ranging from 68.8 % to 103.0 % and relative standard deviations (RSDs) lower than 16 %. 相似文献
13.
Linda Ahonen Pekka Keski-Rahkonen Taija Saarelainen Jenni Paviala Raimo A. Ketola Seppo Auriola Matti Poutanen Risto Kostianen 《Analytica chimica acta》2012
The feasibility of a microfluidic-based liquid chromatography-electrospray ionization/mass spectrometric system (HPLC-Chip/ESI/MS) was studied and compared to a conventional narrow-bore liquid chromatography-electrospray ionization/mass spectrometric (LC-ESI/MS) system for the analysis of steroids. The limits of detection (LODs) for oxime derivatized steroids, expressed as concentrations, were slightly higher with the HPLC-Chip/MS system (50–300 pM) using an injection volume of 0.5 μL than with the conventional LC-ESI/MS (10–150 pM) using an injection volume of 40 μL. However, when the LODs are expressed as injected amounts, the sensitivity of the HPLC-Chip/MS system was about 50 times higher than with the conventional LC-ESI/MS system. The results indicate that the use of HPLC-Chip/MS system is clearly advantageous only in the analysis of low-volume samples. Both methods showed good linearity and good quantitative and chromatographic repeatability. In addition to the instrument comparisons with oxime derivatized steroids, the feasibility of the HPLC-Chip/MS system in the analysis of non-derivatized and oxime derivatized steroids was compared. The HPLC-Chip/MS method developed for non-derivatized steroids was also applied to the quantitative analysis of 15 mouse plasma samples. 相似文献
14.
Nils Helge Schebb David Falck Helene Faber Eva-Maria Hein Uwe Karst Heiko Hayen 《Journal of chromatography. A》2009,1216(27):5249-5255
A new liquid chromatography–electrospray ionization mass spectrometry (LC–ESI-MS) method for the fast determination of phospholipase A2 (PLA2) activity has been developed. For the first time, the method allows the parallel detection of glycerophosphatidylcholine (GroPCho) as PLA2 substrate as well as of its products fatty acid (FA) and lyso-GroPCho. ESI-MS was carried out in negative ion mode, detecting the FA as [M − H]− ions and the lyso-GroPCho and GroPCho as acetate adducts [M + Ac]−. Utilizing a fast gradient on a short C5-modified silica gel column with 3 μm particles, five GroPChos, five FAs and six lyso-GroPChos could be separated according to their chain length in less than 3 min. A very high average chromatographic efficiency of 41,200 theoretical plates (plate height 0.5 μm) was achieved for the separation of the GroPChos. The method was applied for monitoring the release of arachidonic acid (20:4 FA) and 1-stearoyl-lyso-sn-GroPCho (18:0 GroPCho) from unilamellar vesicles of 1-stearoyl-2-arachidonoyl-sn-GroPCho (18:0/20:4 GroPCho). With a limit of detection of 0.5 pmol (total amount injected on column) for the FAs and lyso-GroPChos and 1.5 pmol for the GroPChos as well as a linear range of 1.5 decades, the method has proven to be suitable for the monitoring of different secretory PLA2 (sPLA2) conversions. Furthermore, it was applied to screen a small library of PLA2 inhibitors for their activity towards sPLA2 type V and snake venom of Bothrops moojeni. In both cases, active samples could be directly identified. With its short analysis time, its high chromatographic efficiency and the parallel detection of substrate and all products, the developed LC–ESI-MS method is well suited for the analysis of PLA2 activity. 相似文献
15.
Mohamad Sleiman Randy L. Maddalena Lara A. Gundel Hugo Destaillats 《Journal of chromatography. A》2009,1216(45):7899-7905
Tobacco-specific nitrosamines (TSNAs) are some of the most potent carcinogens in tobacco and cigarette smoke. Accurate quantification of these chemicals is needed to help assess public health risks. We developed and validated a specific and sensitive method to measure four TSNAs adsorbed to model surfaces and secondhand smoke (SHS) particles using gas chromatography–ion-trap tandem mass spectrometry. In an 18-m3 room-sized chamber, a smoking machine generated realistic concentrations of SHS that were actively sampled on Teflon-coated fiber glass (TCFG) filters, and passively sampled on cellulose substrates. A simple solid–liquid extraction protocol using methanol as solvent was successfully applied to both substrates with recoveries ranging from 85 to 115%. For each TSNA, tandem MS parameters were optimized and the major fragmentation pathways were elucidated. The method showed excellent performance, with a linear dynamic range from 2 to 1000 ng mL−1, low detection limits (S/N > 3) of 30–300 pg mL−1 and precision with experimental errors below 10% for all compounds. Moreover, no interfering peaks were observed, indicating a high selectivity of MS/MS without the need for a sample clean-up step. This method provides a suitable analytical tool to detect and quantify traces of TSNA in indoor environments polluted with SHS. 相似文献
16.
17.
Lina Kantiani Marinella Farré Josep Manuel Grases i Freixiedas Damiá Barceló 《Journal of chromatography. A》2010,1217(26):4247-4254
This study presents the development and validation of a sensitive and fast (30 min extraction time and 10 min chromatographic run) method for the detection of penicillins, cephalosporins and sulfonamides in animal feed using pressurised liquid extraction and solid phase extraction as extraction and pre-concentration procedures, followed by liquid chromatography–quadrupole-linear ion-trap mass spectrometry. The developed method was validated showing limits of detection ranging from 0.12 (ampicillin) to 3.94 ng/g (amoxicillin), instrumental and analytical linearity coefficients above 0.99 in both standard and matrix-based solutions as well as relative recoveries ranging from 71% (cefoperazone) to 115% (cefazolin). Repeatability of the method was in the range of 1–9% (RSD %), whereas reproducibility ranged from 3% to 13% (RSD %). The developed and validated method was finally applied to the analysis of real feed samples. The results showed 10 out of 18 analytes to be present in at least one sample and all 14 samples to contain at least one analyte. Penicillin V, oxacillin, ceftiofur, cefoperazone, cefalexin, cefazolin, sulfamethoxypyridazine and sulfapyridine were not detected in any of the samples analysed. Considering the ban of antibacterials as growth promoters added in animal feed, this method is capable of detecting the low concentrations that could result from failure to comply with the regulations or on-site contamination. 相似文献
18.
Yeliz Yikilmaz Ozgur Kuzukiran Ekrem Erdogan Filiz Sen Ozlem Kirmizibayrak Ayhan Filazi 《Biomedical chromatography : BMC》2020,34(10):e4926
We aimed to develop a rapid, simple and reproducible method based on LC–tandem mass spectrometry (LC–MS/MS) to analyze β-agonist residues (clenbuterol, zilpaterol, ractopamine and isoxsuprine) in bovine tissues. The method was validated in accordance with the European Council Decision 2002/657/EC. The samples were homogenized, and then 10 mL of an acetate buffer was added to a 5-g sample. The sample was then centrifuged at 12,000 rpm and filtered. Sodium hydroxide (2 m ) was added to adjust pH of the sample that was centrifuged again. The extract was filtered through a solid-phase extraction column. The residue was re-dissolved in 250 μL acetonitrile and then subjected to LC–MS/MS. The separation was done on a C18 column. The mobile phase consisted of 0.1% formic acid in deionized water and 0.1% formic acid in methanol. The mean recoveries of β-agonists were in the range of 84.3%–119.1% with relative standard deviations (%RSDs) of 0.683%–4.05%. Decision limits and detection capabilities of the analytes ranged from 0.0960 to 4.9349 μg/kg and from 0.0983 to 5.0715, respectively. This method was used to detect four β-agonists in 100 bovine muscle, 100 liver and 100 kidney tissues from a slaughterhouse. No residue was found above the maximum residue limit level. 相似文献
19.
A novel method has been developed for the determination of alkylphenols in soil by ultra-high-pressure liquid chromatography employing small particle sizes, combined with tandem mass spectrometry. Soil samples were extracted with pressurized liquid extraction (PLE) and then cleaned with solid-phase extraction (SPE). The extracts were separated on C18 column (1.7 μm, 50 mm × 2.1 mm) with a gradient elution and a mobile phase consisting of water and acetonitrile, and then detected by an electrospray ionization tandem mass spectrometry in negative ion mode with multiple reaction monitoring (MRM). Compared with traditional liquid chromatography, it took ultra-high-pressure liquid chromatography much less time to analyze alkylphenols. Additionally, the ultra-high-pressure liquid chromatography/tandem mass spectrometry method produces satisfactory reliability, sensitivity, and accuracy. The average recoveries of the three target analytes were 74.0–103.4%, with the RSD < 15%. The calibration curves for alkylphenols were linear within the range of 0.01–0.4 μg/ml, with the correlation coefficients greater than 0.99. When 10 g soil sample was used for analysis, the limits of quantification (LOQs) of the three alkylphenols were all 1.0 μg/kg. 相似文献
20.
Liping Meng Shimin WuFujun Ma Ai JiaJianying Hu 《Journal of chromatography. A》2010,1217(29):4873-4876
A simple, fast and sensitive liquid chromatography–electrospray tandem mass spectrometry method was established for trace levels of nine haloacetic acids (HAAs) in drinking water. Water samples were removed of residual chlorine by adding l-ascorbic acid, and directly injected after filtered by 0.22 μm membrane. Nine HAAs were separated by liquid chromatography in 7.5 min, and the limits of detection were generally between 0.16 and 0.99 μg/L except for chlorodibromoacetic acid (1.44 μg/L) and tribromoacetic acid (8.87 μg/L). The mean recoveries of nine target compounds in spiked drinking water samples were 80.1–108%, and no apparent signal suppression was observed. Finally, this method was applied to determine HAAs in the tap water samples collected from five waterworks in Shandong, China. Nine HAAs except for monochloroacetic acid, monobromoacetic acid, dibromochloroacetic acid and tribromoacetic acid were detected, and the total concentrations were 7.79–36.5 μg/L. The determination results well met the first stage of the Disinfectants/Disinfection By-Products (D/DBP) Rules established by U.S.EPA and Guidelines for Drinking-water Quality of WHO. 相似文献