首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
An analytical method for the determination of 14 organophosphorus flame retardants (OPFRs), including halogenated OPFRs, non-halogenated OPFRs and triphenyl phosphine oxide (TPPO) in biological samples was developed using gas chromatography–mass spectrometry (GC/MS). Biological samples were extracted using microwave-assisted extraction (MAE) with hexane/acetone (1:1, v/v) as the solvent; then, a two-step clean-up technique, gel permeation chromatography (GPC) combined with solid phase extraction (SPE), was carried out before GC/MS analysis. Experimental results showed that the developed method efficiently removed the lipid compounds and co-extract interferences. Moreover, using the relatively “narrow” column (with an i.d. of 10 mm) significantly decreased the elution volume and, therefore, prevented the loss of the most volatile OPFRs, especially trimethyl phosphate (TMP) and triethyl phosphate (TEP). The method detection limits (MDLs) for OPFRs in the biological samples ranged from 0.006 to 0.021 ng g−1 lw, and the recoveries were in the range of 70.3–111%, except for TMP (38.9–55.6%), with relative standard deviations (RSDs) of less than 14.1%. The developed method was applied to determine the amount of the target OPFRs in biological samples (i.e., fish and domestic birds) that were collected from the Pearl River Delta (PRD) region in southern China. Of the 14 OPFRs, tri-n-butyl phosphate (TnBP), tris(2-chloroethyl) phosphate (TCEP), tris(chloropropyl) phosphate (TCPP) and tributoxyethyl phosphate (TBEP) were present in all of the biological samples that were analyzed, and dominated by TnBP, TCEP and TBEP. The concentrations of OPFRs in the biological samples that were collected from the PRD region were higher than those reported in other locations.  相似文献   

2.
An efficient microwave-assisted extraction (MAE) procedure coupled to gas chromatography–mass spectrometry (GC–MS) with electron impact (EI) and chemical ionization (CI) has been developed to determine five organophosphate flame retardants (OPFRs) in marine and river sediments. The effects of various operating parameters on the quantitative extraction of the OPFRs through MAE were systematically investigated. Selected OPFRs were extracted from the sediments through MAE using 40 mL of acetone at 120 °C for 20 min. The limits of quantitation ranged from 0.1 to 0.4 ng/g (dry weight) in 2 g of the sediment samples. Moreover, as the chlorinated alkyl phosphates present no molecular ions in EI, GC–MS with furan-CI (furan-CI) was applied to confirm their determination in complex environmental samples. The recoveries of the selected OPFRs in spiked sediment samples ranged from 62% to 106% (relative standard derivation, 1−11%). The total concentrations of the selected OPFR residues in marine and river sediments ranged from 1.0 to 12.6 ng/g.  相似文献   

3.
何静  叶曦雯  汤志旭  牛增元  罗忻  邹立 《色谱》2020,38(6):679-686
建立了悬浮固化-分散液液微萃取结合液相色谱-串联质谱测定纺织废水中5种痕量磷系阻燃剂的方法。通过对萃取过程中萃取剂、分散剂的种类与体积、盐浓度、溶液pH值等对萃取效率的影响因素优化,确立了最佳萃取条件。采用了密度小于水的十一烷醇(400 μL)为萃取剂,甲醇(300 μL)为分散剂,控制溶液pH值在6~9之间,NaCl添加量为2 g,萃取时间为涡旋2 min。在优化的萃取条件下,该方法在2~100 μg/L均有良好的线性关系,相关系数大于0.995,除二(2,3-二溴丙基)磷酸酯(BIS)的检出限为5 μg/L外,三(2-氯乙基)磷酸酯(TCEP)、三(1,3-二氯-异丙基)磷酸酯(TDCP)、三(1-氮丙啶基)氧化膦(TEPA)和三(2,3-二溴丙基)磷酸酯(TRIS)的检出限均为2 μg/L。后整理、染色和印花等实际废水样品加标试验表明,方法的平均回收率为71.6%~114.5%,RSD为2.7%~11.2%(n=6)。对11个样品进行检测,其中3个废水样品检出TCEP与TDCP化合物,含量为2.6~3.4 μg/L。本方法简单,快速,灵敏度好且环保绿色,能够对纺织废水中的5种痕量磷系阻燃剂进行准确的定性与定量检测。  相似文献   

4.
赖晓芳  冯岸红  幸苑娜  叶淋泉  林志惠  陈泽勇 《色谱》2015,33(11):1186-1191
有机磷酸酯是一类重要的磷系阻燃剂,由于其具有类似持久性有机污染物(persistent organic pollutants, POPs)的性质,欧美等国家已纷纷设立相关法规限制其在儿童用品中的使用。目前国际和国内均未有儿童手推车中有机磷酸酯阻燃剂的检测标准。本文建立了儿童手推车中3种有机磷酸酯阻燃剂的超声萃取-弗罗里硅土固相萃取柱净化-气相色谱/质谱检测方法。该方法的加标回收率为89.5%~107.3%,检出限(3S/N)为0.01 mg/kg,定量限(10S/N)为0.1 mg/kg,能较好地排除基质干扰,适用于儿童手推车软垫材料中3种有机磷酸酯的定性和定量分析。37个样品的分析结果表明,磷酸三(2-氯丙基)酯(TCPP)的检出率为81.1%,含量范围为1.0~15312.8 mg/kg,依据欧盟玩具新指令2014/79/EU, TCPP超标(> 5 mg/kg)率为32.4%;其中2个样品中还检出了磷酸三(2-氯乙基)酯(TCEP)和磷酸三(1,3-二氯-2-丙基)酯(TDCP),含量范围为6.2~44.1 mg/kg,均已超标。可见,市场上的儿童手推车存在较高的有机磷酸酯阻燃剂暴露风险。  相似文献   

5.
Organophosphate esters have been extensively used as flame retardants and plasticizers. The analysis of organophosphate esters in the environment is a hot topic because many of them are toxic and persistent. We developed a novel procedure for determining organophosphate esters in sediment. In this work, pressurized liquid extraction and solid‐phase microextraction are used for sample preparation to extract and concentrate the analytes, which are then analyzed by gas chromatography with flame photometric detection. The extraction parameters of pressurized liquid extraction were investigated and optimized by orthogonal design and then evaluated by range analysis and analysis of variance. Under the optimal conditions, the proposed procedure showed wide linear ranges (0.90–100 ng/g) with correlation coefficients ranging from 0.9921 to 0.9990. The detection limits of the method were in the range of 0.009–0.280 ng/g with standard deviations ranging from 2.2 to 9.5%. Recoveries of the proposed method ranged from 82.3 to 108.9% with relative standard deviations <8.4%. The obtained method was applied successfully to the determination of organophosphate esters in real sediments with recoveries varying from 79.8 to 107.3%. The proposed method was proved to be simple, easy, and sensitive for analyzing organophosphate esters in sediment samples.  相似文献   

6.
Graphene‐doped Fe3O4 nanocomposites were prepared by a solvothermal reaction of an iron source with graphene. The nanocomposites were characterized by transmission electron microscopy, atomic force microscopy, X‐ray diffraction, superconducting quantum interference, Raman spectroscopy, Fourier transform infrared spectroscopy, and X‐ray photoelectron spectroscopy. This nanomaterial has been used as a magnetic solid‐phase extraction sorbent to extract trace brominated flame retardants from environmental waters. Various extraction parameters were optimized including dosage and reusability of the nanocomposites, and pH of sample matrix. The reliability of the magnetic solid‐phase extraction protocol based on graphene‐doped Fe3O4 nanocomposites was evaluated by investigating the recoveries of 2,4,6‐tribromophenol, tetrabromobisphenol A, 4‐bromodiphenyl ether, and 4,4?‐dibromodiphenyl ether in water samples. Good recoveries (85.0–105.0%) were achieved with the relative standard deviation ranging from 1.1–7.1%. Moreover, it is speculated from characterization and magnetic solid‐phase extraction experiment that there is not only π–π stacking but also possible hydrophobic interaction between the graphene‐doped Fe3O4 nanocomposites and analytes.  相似文献   

7.
Pressurised hot water extraction (PHWE) was coupled on-line with liquid chromatography-gas chromatography (LC-GC) to determine brominated flame retardants in sediment samples. After extraction with pressurised hot water the analytes were adsorbed in a solid-phase trap. The trap was dried with nitrogen and the analytes were eluted to the LC column, where the extract was cleaned, concentrated and fractionated before transfer to the GC system. The fraction containing the brominated flame retardants was transferred to the GC system via an on-column interface. The PHWE-LC-GC method was linear from 0.0125 to 2.5 microg with limits of detection in the range 0.70-1.41 ng/g and limits of quantification 6.16-12.33 ng/g.  相似文献   

8.
A solid–liquid extraction method in combination with high‐performance liquid chromatography and tandem mass spectrometry was developed and optimized for extraction and analysis of organophosphorus flame retardants in soil and fish. Methanol was chosen as the optimum extraction solvent, not only in terms of extraction efficiency, but also for its broader analyte coverage. The subsequent clean‐up by solid‐phase extraction is required to eliminate matrix coextractives and reduce matrix effects. Recoveries of the optimized method were 50–121% for soil and 47–123% for biota, both with high precision (RSDs <12% in soil and <23% in biota). The method limits of detection ranged from 0.06 to 0.20 ng/g dry weight and between 0.02 and 0.30 ng/g wet weight for soil and biota samples, respectively. However, samples with a high lipid content produce several problems as solid‐phase extraction cartridge clogging that increase variability and analysis time. The method was successfully applied for the determination of organophosphorus flame retardants in soil and fish from L'Albufera Natural Park (Valencia, Spain). Target compounds were detected in all soil and fish samples with values varying from 13.8 to 89.7 ng/g dry weight and from 3.3 to 53.0 ng/g wet weight, respectively.  相似文献   

9.
Biotransformation of organophosphorus flame retardants (OPFRs) mediated by cytochrome P450 enzymes (CYPs) has a potential correlation with their toxicological effects on humans. In this work, we employed five typical OPFRs including tris(1,3-dichloro-2-propyl) phosphate (TDCIPP), tris(1-chloro-2-propyl) phosphate (TCIPP), tri(2-chloroethyl) phosphate (TCEP), triethyl phosphate (TEP), and 2-ethylhexyl diphenyl phosphate (EHDPHP), and performed density functional theory (DFT) calculations to clarify the CYP-catalyzed biotransformation of five OPFRs to their diester metabolites. The DFT results show that the reaction mechanism consists of Cα-hydroxylation and O-dealkylation steps, and the biotransformation activities of five OPFRs may follow the order of TCEP ≈ TEP ≈ EHDPHP > TCIPP > TDCIPP. We further performed molecular dynamics (MD) simulations to unravel the binding interactions of five OPFRs in the CYP3A4 isoform. Binding mode analyses demonstrate that CYP3A4-mediated metabolism of TDCIPP, TCIPP, TCEP, and TEP can produce the diester metabolites, while EHDPHP metabolism may generate para-hydroxyEHDPHP as the primary metabolite. Moreover, the EHDPHP and TDCIPP have higher binding potential to CYP3A4 than TCIPP, TCEP, and TEP. This work reports the biotransformation profiles and binding features of five OPFRs in CYP, which can provide meaningful clues for the further studies of the metabolic fates of OPFRs and toxicological effects associated with the relevant metabolites.  相似文献   

10.
Different procedures were examined to extract pure and high concentrations of a series of brominated flame retardants from various polymer materials. These procedures include supercritical carbon dioxide (sc-CO2), modified sc-CO2, solvent and soxhlet extraction. Extraction with sc-CO2 gave low extraction efficiencies (between 6 and 20%) probably due to the low pressure of sc-CO2 used. The use of toluene, acetonitrile and THF as modifier in sc-CO2 raised the extraction efficiencies for many flame retardants. High extraction efficiencies were achieved for tetrabromobisphenol A (TBBPA), TBBPA-bis-(2,3-dibromopropylether) (TBBPA-dbp), TBBPA-carbonatoligomer (TBBPA-co) and decabromodiphenylether (DECA) (between 93 and 100%) by using 1-propanol as solvent during soxhlet extraction. Toluene instead of 1-propanol was used where insufficient extraction of the flame retardant occurred. The materials (before and after extraction) were analysed with energy dispersive X-ray fluorescence analysis (EDXRF), high performance liquid chromatography with ultraviolet detection (HPLC/UV), gas chromatography/mass spectrometry (GC/MS) and infrared spectroscopy (IR) techniques. The properties of the extracted flame retardants such as TBBPA, TBBPA-dbp and 1,2-bis(tribromophenoxy)-ethane (TBPE) are in good agreement with those of standard reference materials.  相似文献   

11.
李健  王翼飞  周显青  施致雄 《分析化学》2016,(11):1742-1747
采用索氏提取、凝胶渗透色谱和固相萃取技术作为前处理方法,建立乳制品中6种新型溴系阻燃剂、8种多溴联苯醚、四溴双酚A和α、β、γ-六溴环十二烷异构体共18种溴系阻燃剂的同时提取与净化方法,并结合气相色谱-负化学源质谱法(GC-NCI/MS)和高效液相色谱-电喷雾电离-串联质谱法(HPLC-ESI-MS/MS)进行检测。奶样经冷冻干燥后以正己烷-丙酮(1:1, V/V)索氏提取,采用凝胶渗透色谱结合酸化硅胶柱净化,随后以LC-Si固相萃取柱分离气相和液相待测物。以GC-NCI/MS测定6种新型溴系阻燃剂和8种多溴联苯醚,以HPLC-MS/MS检测四溴双酚A和六溴环十二烷异构体,内标法定量。结果表明,以空白牛奶样品为加标基质,多数待测物平均回收率为80.1%~114.7%,方法具有良好的精密度(多数待测物相对标准偏差( RSD)在0.87%~14.9%)和灵敏度(检出限在0.2~119.2 pg/g之间),可满足乳制品中多种溴系阻燃剂同时提取、净化和检测需求。  相似文献   

12.
An HPLC-UV/MS method has been developed to identify and quantify flame retardants in post-consumer plastics from waste of electric and electronic equipment (WEEE). Atmospheric pressure chemical ionisation spectra of 15 brominated and phosphate-based flame retardants were recorded and interpreted. The method was applied to detect flame retardant additives in polymer extracts obtained from pressurised liquid extraction of solid polymers. In addition, a screening method was developed for soluble styrene polymers to isolate a flame retardant fraction through the application of gel permeation chromatography (GPC). This fraction was transferred to an online-coupled HPLC column and detected by UV spectroscopy, which allowed a reliable qualitative and quantitative analysis of brominated flame retardants in the polymer solutions.  相似文献   

13.
With more stringent legislation on brominated flame retardants, it is expected that increasing amounts of substitutes would replace polybrominated diphenylethers (PBDEs). Therefore, the development and optimization of analytical methodologies that allow their identification and quantification are of paramount relevance. This work describes the optimization of an analytical procedure to determine pentabromochlorocyclohexane, tetrabromo-o-chlorotoluene, 2,3,5,6-tetrabromo-p-xylene, tetrabromophthalic anhydride, 2,3,4,5,6-pentabromotoluene, tris(2,3-dibromopropyl)phosphate, decabromodiphenylethane and 1,2-bis(2,4,6-tribromophenoxy)ethane together with PBDEs in sediments and in suspended particulate matter. This method comprises a pressurized liquid extraction followed by three cleanup steps (gel permeation chromatography and solid phase extraction on Oasis™ HLB and on silica cartridges). Gas chromatography–mass spectrometry, using electron capture negative chemical ionization, is used for the final analysis. The proposed method provides recoveries >85%. The method was applied to sediment and suspended particulate matter samples from different locations in the Western Scheldt estuary (the Netherlands). To the best of our knowledge, this is the first time that the occurrence of the additive flame retardants 2,3,5,6-tetrabromo-p-xylene, 3,4,5,6-tetrabromo-o-chlorotoluene and 2,3,4,5,6-pentabromochlorocyclohexane is reported in the literature. The concentrations of these new flame retardants ranged from 0.05 to 0.30 μg/kg dry weight.  相似文献   

14.
王庆芝  赵洪霞  王琰  谢晴  陈景文  全燮 《色谱》2017,35(9):1008-1013
以p,p′-二氯二苯三氯乙烷(p,p′-DDT)为参考化合物,采用气相色谱法(GC)测定了14种有机磷阻燃剂(OPFRs)在不同温度(T)条件下的蒸气压(P_(GC))及其蒸发热。根据获得的蒸气压值,发现14种OPFRs的log P_(GC)随着温度的增加而减小。初步探讨了分子结构与log P_(GC)的相关性,结果发现卤代烷基磷酸酯的log P_(GC)低于烷基和芳基磷酸酯,且随着分子摩尔体积的增大,相应的log P_(GC)呈下降趋势。采用逐步回归的方法,建立了OPFRs的相对保留时间(RRT)与log P_(GC)之间的定量构效关系(QSPR)模型,模型的累计交叉有效判别系数Q2cum为0.946。模型对OPFRs的log P_(GC)预测值与实验值有良好的相关性(r=0.980),结果表明所建模型具有良好的稳健性和预测能力。利用建立的方法,通过测定的保留时间参数以及定量构效关系模型,可有效预测目前没有标准品的OPFRs的log P_(GC)值。  相似文献   

15.
This review provides a summary of various analytical methodologies applied to the determination of “novel” brominated flame retardants (NBFRs) in various environmental compartments, as reported in peer reviewed literature, either in print or online, until the end of 2010. NBFRs are defined here as those brominated flame retardants (BFRs) which are either new to the market or newly/recently observed in the environment. The preparation and extraction of sediment, water, sewage sludge, soil, air and marine biota samples, the extract clean-up/fractionation and subsequent instrumental analysis of NBFRs are described and critically examined. Generally, while the instrumental analysis step mainly relies on mass-spectrometric detection specifically developed for NBFRs, and hyphenated to liquid or gas chromatography, preceding steps tend to replicate methodologies applied to the determination of traditional BFRs such as polybrominated diphenyl ethers (PBDEs) and hexabromocyclododecane (HBCD). Shortcomings and gaps are discussed and recommendations for future development are given.  相似文献   

16.
In this study, we present a simple and easy-to-use extraction method that is based on a hollow-fiber microporous membrane liquid-liquid extraction (HF-MMLLE), as an extraction technique, followed by gas chromatography-mass spectrometry (GC-MS) to determine a group of brominated flame retardants (BFRs), polybrominated diphenyl ethers (PBDEs), at trace levels in aqueous samples. The hollow-fiber membrane (HF) filled with organic solvent was immersed into the aqueous sample, spiked with the analytes at ng l(-1) level, and stirred for 60 min. The proposed method could attain enrichment factors (E(e)) up to 5200 times, after optimising parameters, such as organic solvent, stirring speed and extraction time, that affect the extraction. The HF-MMLLE-GC-MS method was successfully applied to the extraction of PBDEs from tap, river and leachate water samples with spike recoveries ranging from 85% to 110%. The method validation with reagent and leachate water samples provided good linearity, detection limits of 1.1 ng l(-1) or lower, both in reagent and leachate water, as well as satisfactory precision in terms of repeatability and reproducibility with values of % relative standard deviation (%RSD) lower than 8.6 and 16.9, respectively.  相似文献   

17.
建立了一种可同时测定锂离子电池电解液中13种有机磷阻燃剂含量的气相色谱-串联质谱分析方法,以乙酸乙酯为萃取溶剂,超声萃取锂离子电池电解液中的有机磷阻燃剂,萃取液经浓缩、定容、过滤后进行气相色谱-串联质谱分析,外标法定量。结果显示,13种有机磷阻燃剂在一定浓度范围内线性良好,相关系数不低于0.999 3,方法的检出限(S/N=3)为0.3~30μg/kg,定量下限(S/N=10)为1~100μg/kg。在低、中、高3个加标水平下的平均回收率为80.4%~94.6%,相对标准偏差(RSD)为3.8%~10%。该方法简单快捷,灵敏度高,定量下限低,可满足锂离子电池电解液中有机磷阻燃剂含量日常检测需要。  相似文献   

18.
Spreading sewage sludge on agricultural lands has been actively promoted by national authorities as an economic way of recycling. However, as by-product of wastewater treatment, sewage sludge may contain toxic substances, which could be incorporated into agricultural products or be distributed in the environment. Moreover, sediments can be contaminated by the discharge of wastewater effluents into rivers. This article reviews the determination of emerging contaminants (surfactants, flame retardants, pharmaceuticals and personal care products) in environmental solid samples (sludge, soil and sediment). Sample preparation, including extraction and clean-up, as well as the subsequent instrumental determination of contaminants are discussed. Recent applications of extraction techniques, such as Soxhlet extraction, ultrasound assisted extraction, pressurised liquid extraction, microwave assisted extraction and matrix solid-phase dispersion to the analysis of emerging contaminants in environmental solid samples are reviewed. Determination of these contaminants, generally carried out by gas chromatography and liquid chromatography coupled with different detectors, especially mass spectrometry for the identification and quantification of residues, is also summarised and discussed.   相似文献   

19.
A headspace solid-phase microextraction gas chromatography coupled with tandem mass spectrometry (HSSPME-GC-MS-MS) methodology for determination of brominated flame retardants in sediment and soil samples is presented. To the best of our knowledge, this is the first time that SPME has been applied to analyze polybrominated biphenyls (PBBs) and polybrominated diphenyl ethers (PBDEs) in environmental solid samples. Analyses were performed using 0.5-g solid samples moisturized with 2 mL water, employing a polydimethylsiloxane (PDMS) fiber coating, exposed to the headspace at 100 °C for 60 min. Several types of environmental solid samples were included in this study and the extraction efficiency was related to the organic matter content of the sample. Calibration was performed using real samples, and the method showed good linearity over a wide concentration range, precision, and afforded quantitative recoveries. The obtained detection limits were in the sub-ng g−1 for all the target analytes in both samples. The proposed procedure was applied to several marine and river sediments and soils, some of which were found to contain PBDEs at concentrations in the ng g−1 level; BDE-47, BDE-100, and BDE-99 were the major congeners detected. The proposed method constitutes a rapid and low-cost alternative for the analysis of the target brominated flame retardants in environmental solid samples, since the clean-up steps, fractionation, and preconcentration of extracts inherent to the classical multi-step solvent extraction procedures are avoided.   相似文献   

20.
采用乙腈提取、固相萃取(SPE)富集浓缩技术结合自行研制开发的毛细管液相色谱(CLC)仪,同时分离测定了食品和水样中1种有机磷和3种氨基甲酸酯类杀虫剂残留。对影响SPE效率和CLC分离检测的各类因素进行了优化,包括固相萃取柱种类、样品pH、洗脱剂种类和体积、上样速率、盐效应、上样体积、检测波长、流动相种类和比例等。结果表明,4种杀虫剂在6 min内达到完全分离,检出限为0.35~1.20 μg/kg,定量限为1.17~4.00 μg/kg。使用该SPE-CLC法对西红柿、黄瓜、苹果样品和自来水、湖水水样进行加标回收测定,得到食品中加标回收率为72.41%~107.15%,相对标准偏差≤8.12%;水样中加标回收率为71.45%~109.25%,相对标准偏差≤9.28%。该法能够满足农药多残留分析要求。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号