首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 359 毫秒
1.
Methodology is described for the simultaneous determination of D-penicillamine, penicillamine disulfide and the penicillamine-glutathione mixed disulfide, as well as glutathione and glutathione disulfide, in human plasma, erythrocytes and urine. The various thiols and disulfides are separated by reversed-phase ion-pairing liquid chromatography with detection by an electrochemical detector with dual gold/mercury amalgam electrodes in series. The thiols are detected at the downstream electrode; the disulfides are reduced at the upstream electrode and then detected as the thiols at the downstream electrode. Detection limits (at a signal-to-noise ratio of 2.0) are in the picomole range for 20 microliters of injected solution for all compounds except penicillamine disulfide, which has a detection limit of 600 pmol in 20 microliters. A convenient method is described for preparation of the penicillamine-glutathione mixed disulfide by thiol/disulfide exchange with standardization of the solution by 1H NMR spectroscopy.  相似文献   

2.
Developing methods to probe the nature and structure of nanoscale environments continues to be a challenge in nanoscience. We report a cyclic voltammetry investigation of the internal, hydrogen-bond-driven phase separation of amide-containing thiols and alkanethiols. Amide-containing thiols with a terminal ferrocene carboxylate functional group were investigated in two binary monolayers, one homogeneously mixed and the other phase separated. The electrochemical response of the ferrocene probe was used to monitor adsorbate coverage, environment, and phase separation within each of these monolayers. The results demonstrate that the behavior of ferrocene-containing monolayers can be used to probe nanoscale organization.  相似文献   

3.
Simultaneous determination of 3,4-methylenedioxymethamphetamine (MDMA) and 3,4-methylenedioxyamphetamine (MDA) in rat blood and brain microdialysates by high-performance liquid chromatography with fluorescence detection (HPLC-FL) was developed. Microdialysates were directly subjected to derivatization with 4-(4,5-diphenyl-1H-imidazol-2-yl)benzoyl chloride (DIB-Cl). The DIB-derivatives of MDMA, MDA and the internal standard, 1-methyl-3-phenylpropylamine (MPPA), were isocratically separated on an ODS column using a mixture of 50 mm phosphate buffer (pH 7.0)-acetonitrile-methanol-2-propanol (50:45:5:2, v/v/v/v %) as an eluent at a flow rate of 1.5 mL/min. The calibration curves of MDA and MDMA spiked to blood and brain microdialysates were linear over the ranges 2.5-500 and 5.0-1000 ng/mL, respectively. The detection limits of MDA and MDMA were 1.2 and 4.2 for blood and 1.3 and 4.8 ng/mL for brain, respectively. Additionally, the intra- and the inter-assay precisions were lower than 5.6% for the blood and brain microdialysates (n = 4). The proposed method was successfully applied for the monitoring of MDMA and its metabolite MDA in rat blood and brain microdialysates, and the pharmacokinetic parameters of MDMA and MDA in the microdialysates after administration of MDMA (5 mg/kg, i.p.) with or without caffeine (20 mg/kg, i.p.) were evaluated.  相似文献   

4.
Chen G  Zhang L  Wang J 《Talanta》2004,64(4):1018-1023
Multi-walled carbon nanotube (CNT) was mixed with epoxy to fabricate microdisc electrode used as a detector for a specially designed miniaturized capillary electrophoresis (CE)-amperometric detection system for the separation and detection of several bioactive thiols. The end-channel CNT amperometric detector offers favourable signal-to-noise characteristics at a relatively low potential (0.8 V) for detecting thiol compounds. Factors influencing the separation and detection processes were examined and optimized. Four thiols (homocysteine, cysteine, glutathione, and N-acetylcysteine) have been separated within 130 s at a separation voltage of 2000 V using a 20 mM phosphate running buffer (pH 7.8). Highly linear response is obtained for homocysteine, cysteine, glutathione, and N-acetylcysteine over the range of 5-50 μM with detection limits of 0.75, 0.8, 2.9, and 3.3 μM, respectively. Good stability and reproducibility (R.S.D. < 5%) are obtained reflecting the minimal adsorption of thiols at the CNT electrode surface. The new microchip protocol should find a wide range of bioanalytical applications involving assays of thiol compounds.  相似文献   

5.
When alkane thiols and disulfides coadsorb onto gold, they do not necessarily create a mixed monolayer. In particular, when thiols are terminated in groups capable of hydrogen bonding, they can altogether eliminate adsorption of disulfides. Such elimination can be observed directly by using fluorescently labeled disulfides and monitoring their adsorption (or lack of) by fluorescence microscopy. These experiments suggest a mechanism in which adsorption of thiols is facilitated by hydrogen bonding.  相似文献   

6.
Nonaqueous capillary electrophoresis (NACE) was applied to the determination of illicit drugs. The complete separation of amphetamine, methamphetamine, 3,4-methylene dioxy amphetamine (MDA), 3,4-methylene dioxy methamphetamine (MDMA), mescaline, cocaine and benzoylecgonine was obtained using an acetonitrile based buffer solution containing 10 mM sodium acetate and 1 M acetic acid. Electrochemical detection using a Pt microdisk electrode set to a potential of +1.8 V was found to be selective for MDA, MDMA and mescaline. The detection limits for these compounds were in the low ng/mL range which is between 2 and 3 orders of magnitude lower compared to UV-detection.  相似文献   

7.
Nonaqueous capillary electrophoresis (NACE) was applied to the determination of illicit drugs. The complete separation of amphetamine, methamphetamine, 3,4-methylene dioxy amphetamine (MDA), 3,4-methylene dioxy methamphetamine (MDMA), mescaline, cocaine and benzoylecgonine was obtained using an acetonitrile based buffer solution containing 10 mM sodium acetate and 1 M acetic acid. Electrochemical detection using a Pt microdisk electrode set to a potential of +1.8 V was found to be selective for MDA, MDMA and mescaline. The detection limits for these compounds were in the low ng/mL range which is between 2 and 3 orders of magnitude lower compared to UV-detection.  相似文献   

8.
Several procedures using high-performance liquid chromatography with photodiode-array detection have been developed to create phytochemical and toxicological profiles of phenylalkylamine derivatives in biological samples (e.g. plant materials and urine). Mescaline-containing cactus samples were extracted with basic methanol, using methoxamine as internal standard; the extraction and clean-up of urine samples were performed on cation-exchange solid-phase extraction columns. The extracts were separated on a 3-micron ODS column with acetonitrile-water-phosphoric acid-hexylamine as the mobile phase. Peak detection was performed at 198 or 205 nm; peak identity and homogeneity were ascertained by on-line scanning of the UV spectra from 190 to 300 nm. The detection limit of phenylalkylamine derivatives in urine and cactus material was 0.026-0.056 micrograms/ml and 0.04 micrograms/mg, respectively. Following a single oral dose of 1.7 mg/kg methylenedioxymethylamphetamine (MDMA) the concentrations found in urine ranged from 1.48 to 5.05 micrograms/ml MDMA and 0.07-0.90 micrograms/ml methylenedioxyamphetamine (a metabolite of MDMA). The mescaline content of the cactus Trichocereus pachanoi varied between 1.09 and 23.75 micrograms/mg.  相似文献   

9.
Wei Sun  Wenhua Li  Jing Li  Jian Zhang  Lupei Du  Minyong Li 《Tetrahedron》2012,68(27-28):5363-5367
Herein, we report the design and synthesis of two naphthalimide-based fluorescent probes. These probes provided high on/off signal ratios and exhibited good selectivity towards thiols over other analytes. Thus, they were identified as good sensors for the detection of thiols both in living cells and in rabbit plasma samples.  相似文献   

10.
A new colorimetric and fluorescent probe,2-(2,4-dinitrostyryl)-1,3,3-trimethyl-3H-indolium iodide (DTI),for selective and sensitive detection of biological thiols is reported.In aqueous solution at physiological pH 7.4,biological thiols react with DTI via Michael addition to give the brownish red adduct concomitant with fluorescence emission decrease.  相似文献   

11.
A TCNQ-based triphenylamine derivative (1) with strong intramolecular charge transfer (ICT) character was designed as a colorimetric sensor for thiols. Upon addition of thiols, the absorption spectrum of sensor 1 in aqueous solution was remarkably changed because the adduct of 1 with thiol decreased its ICT character. Sensor 1 showed highly selective and sensitive sensing ability toward thiols over other analytes. This selectivity could be easily observed by naked eyes, indicating that sensor 1 is a potential colorimetric sensor for thiols.  相似文献   

12.
A colorimetric and ratiometric fluorescent thiol probe was devised with diketopyrrolopyrrole (DPP) fluorophore. The probe gives absorption and emission at 523 and 666 nm, respectively. In the presence of thiols, such as cysteine, the absorption and emission band shifted to 479 and 540 nm, respectively. Correspondingly, the color of the probe solution changed from purple to yellow, and the fluorescence changed from red to yellow. The emission intensity at 540 nm was enhanced by 140-fold. The Stokes shift of probe 1 (107 nm) is much larger than the unsubstituted DPP fluorophore (56 nm). Mass spectral analysis demonstrated that besides the expected Michael addition of thiols to the C═C bonds, the CN groups of the malonitrile moieties also react with thiols to form 4,5-dihydrothiazole structure. Probe 1 was used for fluorescence imaging of intracellular thiols. In the presence of thiols, both the green and red channel of the microscopy are active. With removal of the intracellular thiols, signal can only be detected through the red channel; thus, ratiometric bioimaging of intracellular thiols was achieved. The ratiometric response of probe 1 was rationalized by DFT calculations. Our complementary experimental and theoretical studies will be useful for design of ratiometric/colorimetric molecular probes.  相似文献   

13.
A precise and feasible HPLC method has been developed for the analysis of amphetamine (AMPH), methamphetamine (MAMPH) and methylenedioxymethamphetamine (MDMA, ecstasy) in human urine. A chromatographic run on a C8 Genesis (150 mm x 4.6 mm, 5 microm) column maintained at 30 degrees C lasts about 17 min, using a mobile phase composed of ACN (12%) and a pH 2.5 phosphate buffer (88%) containing 0.3% triethylamine. Mirtazapine was used as the internal standard. Good linearity was found in the 100-2000 ng/mL concentration range for AMPH and MAMPH and in the 12-2000 ng/mL concentration range for MDMA. The pretreatment of urine samples was carried out by means of a careful SPE procedure on C2 cartridges. The extraction yields were very satisfactory for all analytes, with average values greater than 97%. The leading conditions allowed the determination of AMPH, MAMPH and MDMA with satisfactory precision and accuracy. The method has been successfully applied to the determination of the analytes in urine of AMPH users.  相似文献   

14.
This paper describes a highly sensitive HPLC method for the simultaneous determination of 3,4-methylenedioxymethamphetamine (MDMA), 3,4-methylenedioxyamphetamine (MDA), amphetamine (AP) and methamphetamine (MP) in human hair samples. The amphetamines investigated were derivatized with the fluorescent reagent, DIB-Cl to yield highly fluorescent DIB-derivatives, which were then analyzed by HPLC with fluorescence detection at excitation and emission wavelengths of 325 nm and 430 nm, respectively. The separation was achieved on an ODS column with an isocratic mobile phase composed of acetonitrile-methanol-water (30:40:30, v/v/v). The limits of detection for the four compounds obtained by the proposed method ranged from 11 to 200 pg/mg. The method was successfully applied to the determination of MDMA and MDA in hair samples obtained from MDMA abuser.  相似文献   

15.
A sensitive semi-micro column high-performance liquid chromatography with fluorescence detection method was developed for the determination of 3,4-methylenedioxymethamphetamine (MDMA), 3,4-methylenedioxyamphetamine (MDA), methamphetamine (MP) and amphetamine (AP) in human hair. 4-(4,5-Diphenyl-1H-imidazol-2-yl)benzoyl chloride (DIB-Cl) and 1-methyl-3-phenylpropylamine were used as labeling reagent and internal standard, respectively. These drugs were extracted from hair into 5% trifluoroacetic acid in methanol, and fluorescent labeled with DIB-Cl. The separation of DIB-derivatives was achieved on a reversed-phase semi-micro ODS column with an acetonitrile-methanol-water (30:40:30, v/v/v%) mixture as a mobile phase. The limits of detection at a signal-to-noise ratio of 3 for MDMA, MDA, MP and AP were 0.25, 0.15, 0.25 and 0.19 ng/mg, respectively. Precision of intra- and inter-day assay as the relative standard deviation were in the range 1.5-6.8% (n = 5) and 2.7-4.7% (n = 5), respectively. The proposed method was highly sensitive and able to detect MDMA and its related compounds in small amounts of hair sample, and could be applied to quantification of six abusers' hair samples.  相似文献   

16.
《Tetrahedron: Asymmetry》2000,11(17):3481-3493
A suitable method for the preparation of the chiral mixed O/S ligands 1,2-sulfinyl thiols is described. These compounds have then been used as a chiral proton source in the enantioselective protonation of 2-methyl tetralone enolate and the results are compared with those obtained from the analogous alcohols. A theoretical model is proposed to explain the different behaviors exhibited in the protonation reaction for each of these proton sources. Configurational assignments for the new chiral thiols have been carried out by means of X-ray analysis.  相似文献   

17.
We have recently described a new method to determine physiological thiols, in which the quantification of plasma homocysteine, cysteine, cysteinylglycine, glutathione, and glutamylcysteine was achieved after derivatization with 5-iodoacetamidofluorescein. Samples were separated and measured by capillary electrophoresis with laser-induced fluorescence in an uncoated fused-silica capillary, using a phosphate/borate run buffer and the organic base N-Methyl-D-glucamine as effective electrolyte addictive to obtain a baseline peak separation. In this paper, we propose an improvement of our method useful for the analysis of the intracellular thiols in different cultured cells. In particular, we studied run buffer and injection conditions in order to increase the sensitivity of the assay and we found that, by incrementing two times the injected volume and using the water plug before the sample injection, the sensitivity of our previous method was increased by about ten times. To maintain a good resolution between peaks, particularly between homocysteine and the internal standard d-penicillamine, we lengthened the run time by incrementing the concentration of the electrolyte buffer and the organic base d-glucamine and by decreasing the cartridge temperature from 40 to 25 degrees C. After these changes in electrophoretical parameters, cellular thiols were baseline-resolved in less than 14 min instead of 9 min as in our previous method, but the limit of quantification is increased from 50 to 1 nmol/L. This new procedure allows also to measure the intracellular thiols commonly found at low concentration, such as cysteinylglycine, glutamylcysteine, and homocysteine. The new analytical method performance was assessed by measuring the intracellular thiols in three different cell lines, i.e., HUVEC, ECV304, and R1 stem cells.  相似文献   

18.
Binary mixtures of 11-mercaptoundecanoic acid (MUA) and other thiols of various lengths and terminal functions were chemisorbed on gold-coated surfaces via S–Au bonds to form mixed self-assembled monolayers (SAMs). Several values of the mole fraction of MUA in the thiol mixtures were tested and the structure and composition of the resulted thin films were characterized by X-ray photoelectron spectroscopy (XPS) and polarization modulation infrared reflection-absorption spectroscopy (PM-IRRAS). The results made it clear that co-adsorption of MUA with thiols of similar chain length led to well-ordered monolayers whereas the co-adsorption of MUA with shorter thiols yielded less crystalline-like thin films, but with more reactive carboxylic acid terminal groups. This criterion appeared decisive for efficient covalent binding of Staphylococcus aureus Protein A (PrA), a protein that displays high affinity for the constant fragment (Fc) of antibodies of the IgG type from various mammal species. The ability of immobilized Protein A to recognize and bind a model IgG appeared to be optimal for the mixed SAM of MUA and the short-chain, ω-hydroxythiol 6-mercaptohexanol in the proportion 1–3.  相似文献   

19.
Thiols play critical roles in regulating biological functions and have wide applications in pharmaceutical and biomedical industries. However, we still lack a general approach for the simultaneous detection of various thiols, especially in complex systems. Herein, we establish a 19F NMR platform where thiols are selectively fused into a novelly designed fluorinated receptor that has two sets of environmentally different 19F atoms with fast kinetics (k2 = 0.73 mM−1 min−1), allowing us to generate unique two-dimensional codes for about 20 thiols. We demonstrate the feasibility of the approach by reliably quantifying thiol drug content in tablets, discriminating thiols in living cells, and for the first time monitoring the thiol related metabolism pathway at the atomic level. Moreover, the method can be easily extended to detect the activity of thiol related enzymes such as γ-glutamyl transpeptidase. We envision that the versatile platform will be a useful tool for detecting thiols and elucidating thiol-related processes in complex systems.

A 19F NMR platform, capable of discriminating various small molecule thiols, was designed for in-cell thiol differentiation and monitoring, and further detection of the γ-GT activity, demonstrating the wide applications in thiol-related processes.  相似文献   

20.
Salimi A  Hallaj R 《Talanta》2005,66(4):967-975
The performance of preheated glassy carbon electrode modified with carbon nanotubes is described. First glassy carbon electrode is heated for 5 min at 50 °C, then abrasive immobilization of multiwall carbon nanotubes on a preheated glassy carbon electrode was achieved by gentle rubbing of electrode surface on a filter paper supporting carbon nanotubes. Carbon nanotubes (CNTs)-modified glassy carbon electrodes exhibit strong and stable electrocatalytic response toward thiols oxidation in wide pH range. These properties permit an important decrease in over voltage for the oxidation of thiocytosine, glutathione and l-cysteine, as well as a dramatic increase in the peak currents in comparison with bare glassy carbon electrode. Furthermore, the thiols amperometric response of the coated electrodes is extremely stable, with more than 95% of the initial activity after 30 min stirring of 0.1 mM thiols. The electrocatalytic behavior is further exploited as a sensitive detection scheme for thiols detection by hydrodynamic amperometry. The substantial decrease in the overvoltage of the thiols oxidation associated with a stable amperometric response and antifouling properties of nanotubes films allow the development of highly sensitive thiols sensor without using any redox mediator. Such ability of carbon nanotubes to promote the thiols electron transfer reaction, short response time (5 s) and long-term stability, low detection limit, extended linear concentration range, high sensitivity suggest great promise for thiols amperometric sensors and detector for chromatographic analysis of thiol derivatives.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号