首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 1 毫秒
1.
2.
An improved high-performance liquid chromatographic method for the simultaneous determination of caffeine and its N-demethylated metabolites in plasma is described. Excellent resolution of all components is provided by reversed-phase chromatography using a mobile phase consisting of 1% acetic acid-methanol (83:17) at a flow-rate of 2.7 ml/min, in conjunction with a Waters Assoc. Nova-Pak C18 column which was protected by a Waters Assoc. Guard-Pak precolumn module containing a Guard-Pak CN cartridge. Rapid extraction of caffeine and the dimethylxanthines from plasma was achieved using reversed-phase octadecylsilane bonded-silica columns (Bond-Elut C18). With only 100 microliters of sample, plasma levels in the region of 50 ng/ml for the dimethylxanthines and 100 ng/ml for caffeine can be determined using ultraviolet detection at 273 nm. The method has been used for measuring umbilical cord plasma samples to provide information regarding foetal exposure to caffeine and its metabolites and is also suitable for therapeutic drug monitoring of caffeine and theophylline levels in the treatment of neonatal apnoea.  相似文献   

3.
4.
5.
6.
7.
An improved semi-automated high-performance liquid chromatographic method is described for the routine determination of unconjugated 3-methoxy-4-hydroxyphenylethyleneglycol in plasma. The 3-ethoxy analogue of the compound is used as an internal standard. The method is based on purification of 0.5-ml plasma samples with phenyl-type reversed-phase extraction columns, reversed-phase separation with an acetate-citrate-methanol mobile phase with an octadecyl-bonded column, and dual-electrode coulometric detection with oxidation at +0.44 V and reduction at -0.25 V. The precision and accuracy of the assay are satisfactory: the lower limit of reliable detection corresponds to a plasma concentration of 1.5 nM. The validity of the determination is demonstrated by an 18% mean increase in plasma levels of 3-methoxy-4-hydroxyphenylethyleneglycol during physical exercise (duration 16 min, n = 13) and a 50% mean reduction in plasma levels induced by a single dose of the monoamine oxidase inhibitor, moclobemide (n = 8). The method is suitable for routine use in pharmacological and physiological experiments.  相似文献   

8.
9.
The effect of varying the type of column and eluent composition on drug-free plasma profiles was investigated. The study was based on a C18 and a CN column; methanol and acetonitrile were the organic modifiers used. The plasma profiles were evaluated quantitatively by measuring the number of interfering peaks greater than 8 . 10(-4) absorbance units in the area of interest along the chromatogram. Results were subjected to statistical treatment using a three-factor analysis of variance design. The three factors were the column, the type of organic modifier and either the percentage organic modifier, the pH or the ionic strength. Analysis of the data revealed that significant effects were seen with changing eluent composition, particularly with regard to the percentage of organic modifier, and that the observed effects were strongly dependent on the type of column and the type of organic modifier under consideration.  相似文献   

10.
Coenzyme (Co) Q10 was dissociated from lipoproteins in plasma by treatment with methanol and extraction with n-hexane. Subsequent clean-up on silica gel and C18 solid-phase extraction cartridges with complete recovery (99 +/- 1.2%) produced a clean extract. High-performance liquid chromatographic (HPLC) separation was performed on a C18 reversed-phase column. Three simple, rapid procedures are presented: HPLC with final UV (275 nm) detection, a microanalysis utilizing a three-electrode electrochemical detector and a microanalysis with column-switching HPLC and electrochemical detection. The methods correlate very well with classical ethanol-n-hexane extraction with UV detection. The identity and purity of the Co Q10 peak were investigated and the resulting methods were concluded to be suitable for total plasma Co Q10 determination. The average level in healthy subjects was 0.80 +/- 0.20 mg/l; the minimum detectable Co Q10 plasma level was 0.05 and 0.005 mg/l for UV and electrochemical detection, respectively. The methods were applied to many samples and the plasma Co Q10 reference values for healthy subjects, athletes, hyperthyroid, hypothyroid and hypercholesterolaemic patients are given.  相似文献   

11.
The determination of doxazosin by high-performance liquid chromatography with fluorescence detection is described. Propanolol was used as the internal standard. Plasma samples were treated with methanol to precipitate the proteins. Doxazosin was isolated with C18 reversed-phase extraction columns. The determination limit is 1 ng/ml of plasma, while the extraction columns can be reused frequently. The method is applied to clinical trial samples.  相似文献   

12.
An isocratic reversed-phase high-performance liquid chromatographic method with on-line solid-phase extraction for the simultaneous determination of amitriptyline and nortriptyline in serum has been developed. A 250-microliters serum sample is injected directly onto a commercially available CN cartridge and, after a washing step, the retained solutes are backflushed onto a bonded-phase CN column using a column-switching technique and a mobile phase composed of acetonitrile (26%) and 0.05 M phosphate buffer with diethylamine. Serum is diluted with 0.1 M sodium lauryl sulphate and centrifuged before the injection. Detection at 210 nm ensures sufficient sensitivity. The recovery is almost quantitative and the relative standard deviation ranges from 2.8 to 8.0% for concentrations of 200-40 ng/ml. Being rapid and simple, the method is convenient for routine use.  相似文献   

13.
A sensitive solid-phase extraction/high-performance liquid chromatographic method with ultraviolet detection was established for the analysis of salvianolic acid B in rabbit plasma. The analyte was separated on a reversed-phase column with trifluoroacetic acid-methanol-acetonitrile (70:10:20, v/v/v) as mobile phase at a flow rate of 1 mL/min, and ultraviolet detection at 315 nm. The calibration curve for salvianolic acid B was linear over the range 35-1400 microg/L with coefficients of correlation >0.999. The inter-day and intra-day precisions of analysis were <15%, and assay accuracy ranged from 95.3 to 109.1%. This method is suitable for determining salvianolic acid B in plasma and thus investigating the pharmacokinetics of salvianolic acid B.  相似文献   

14.
Simultaneous determination of the six sulfonamides (SAs) sulfadiazine, sulfadimidine, sulfamonomethoxine, sulfamethoxazole, sulfadimethoxine and sulfaquinoxaline in chicken using matrix solid-phase dispersion (MSPD) with neutral aluminium oxide as an MSPD sorbent and high-performance liquid chromatography (HPLC) is presented. In the present MSPD, six SAs could be isolated by only one step, elution with a 70% (v/v) aqueous ethanol solution, without the sorbent conditioning and the sorbent-tissue matrix washing. For the HPLC determination, a LiChrospher 100 RP-8 and a mixture of 1% acetic acid solution (pH 3.0, in water)-acetonitrile-N,N-dimethylformamide (78:22:5, v/v/v) as the mobile phase with a photodiode array detector were used. Average recoveries were greater than 87.6% with relative standard deviations between 0.5 and 8.6%. The total time and amount of solvent required for the analysis of one sample were <1.5 h and <12 ml, respectively.  相似文献   

15.
Summary Due to manifold physiological and cardioprotective actions of adenosine, the demand for a simple but accurate method to determine its concentration in plasma is increasing. The aim of this study was firstly to develop a simple isocratic method instead of the gradient elution or peak-shifting techniques used earlier and secondly to check conflicting data on the composition of stop-solution, added to the sample in order to prevent changes in adenosine concentration. Isocratic elution improved signal to noise ratio and concentrations of 100 mol L–1 dipyridamole and 2.5 mol L–1 erythro-9(2-hydroxy-3-nonyl)adenine in the blood sample effectively prevented both adenosine formation and degradation, even without the use of a 5-ecto-nucleotidase inhibitor. Lowering the concentration of dipyridamole to 25 mol L–1 caused more than a tenfold increase of adenosine concentration in two out of five cases and even 100 mol L–1 dipyridamole alone is not sufficient to inhibit adenosine deaminase in blood samples.  相似文献   

16.
A rapid, sensitive and simple to operate high-performance liquid chromatographic method for the simultaneous determination of carbamazepine (CBZ) and carbamazepine 10,11-epoxide (CBZ-EP) in plasma and saliva is described. The drug and its metabolite are extracted from both plasma and saliva using commercially available reversed-phase octadecylsilane bonded silica columns (Bond-Elut C18, 2.8 ml capacity). Separation of CBZ and CBZ-EP was achieved by reversed-phase chromatography, using a mobile phase consisting of acetonitrile-methanol-water (19:37:44) at a flow-rate of 1.8 ml/min in conjunction with a Nova-Pak C18 column. The analytical column, in Radial-Pak cartridge form, was used in combination with a Z-module RCSS and protected by a Guard-Pak precolumn module containing a Guard-Pak mu Bondapak C18 insert. Using ultraviolet detection at 214 nm, levels in the region of 50-100 ng/ml for CBZ and CBZ-EP can be measured with only 250 and 500 microliters of plasma and saliva, respectively. The method, which has been used to determine steady-state concentrations of the drug and its metabolite in paediatric patients receiving CBZ monotherapy, is also suitable for pharmacokinetic studies.  相似文献   

17.
A method is described by which underivatized metoprolol enantiomers in plasma can be quantitated by high-performance liquid chromatography with fluorescence detection. Samples are prepared for injection using a simple solid-phase extraction procedure which is essentially 100% efficient for all analytes. The metoprolol enantiomers are resolved using a cellulose tris(3,5-dimethylphenylcarbamate) chiral stationary phase and a hexane-ethanol-diethylamine mobile phase. Samples were tested for adaptability to autoinjection and found to be stable for at least 16 h after reconstitution in mobile phase. The automated method was determined to be precise and accurate for enantiomer concentrations as low as 10 ng base per ml and was successfully employed in a pharmacokinetic investigation.  相似文献   

18.
19.
A high-performance liquid chromatography method is described for the simultaneous determination of the biogenic amines tryptamine, 2-phenylethylamine, putrescine, cadaverine, histamine, tyramine, spermidine, and spermine in cheese. The optimization of the procedure for the extraction of amines from the matrix is described. The separation of dansyl derivatives of the amines was achieved by reversed-phase liquid chromatography with gradient elution, followed by UV detection at 254 nm. The mobile phase was acetonitrile-0.01 M phosphate buffer (pH 7)-water. Under these conditions, rapid elution of the amines in less than 13 min was obtained. Validation of the method included calibration experiments, addition of standard amines for the determination of amine recoveries and repeatability tests.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号