首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 78 毫秒
1.
H. Kiriyama 《Laser Physics》2007,17(4):472-477
We report on a high-contrast, high-peak power laser system, which combines both conventional laser amplification and optical parametric chirped pulse amplification (OPCPA) techniques. By employing an OPCPA system after a regenerative amplifier, we have enhanced the prepulse contrast by six orders of magnitude. A prepulse contrast of better than 4.4 × 10?11 has been measured with a high-energy broadband pulse of 24 mJ at a 10 Hz repetition rate from the OPCPA system. With a subsequent four-pass Ti:sapphire amplifier, we have achieved an amplified energy of 279 mJ and an ultrashort recompressed amplified pulse duration of 23.5 fs. We also discuss the basic design aspects and present our preliminary experimental investigations for higher energy operation to a multijoule.  相似文献   

2.
We demonstrate an optical parametric chirped-pulse amplification (OPCPA) system with the pulse energy of 1.5 mJ at a 1 kHz repetition rate. The newly developed 100 ps Ti:sapphire pump laser system, which was optically synchronized with OPCPA seed pulses, delivered 10 mJ, 400 nm pump pulses. After three-stage parametric amplification, recompression of the amplifier output from 45 ps to 6.4 fs was performed. The pulse width of 6.4 fs is, to our knowledge, the shortest ever obtained by OPCPA, and the average power of 1.5 W (1.5 mJ, 1 kHz) is believed to be the highest among few-cycle OPCPA systems.  相似文献   

3.
Optical parametric chirped-pulse amplification (OPCPA) can be used to improve the prepulse contrast in chirped-pulse amplification systems by amplifying the main pulse with a total saturated OPCPA gain, while not affecting the preceding prepulses of the seed oscillator mode-locked pulse train. We show that a simple modification of a multistage OPCPA system into a cascaded optical parametric amplifier (COPA) results in an optical switch and extreme contrast enhancement that can completely eliminate the preceding and trailing oscillator pulses. Instrument-limited measurement of a prepulse contrast ratio of 1.4 x 10(11) is demonstrated from COPA at a 30 mJ level.  相似文献   

4.
The authors have demonstrated an optical parametric chirped-pulse amplification (OPCPA)/Yb:YAG ceramic thin disk hybrid laser system having hundred mJ level pulse energy sub-picosecond pulse duration with high temporal contrast. At an input chirped-pulse energy of 3.8?mJ from an OPCPA preamplifier an output energy of 130?mJ has been generated from multipass diode-pumped Yb:YAG ceramic thin disk amplifier. A recompressed pulse duration of 450?fs with a contrast level of less than 7.2×10?9 at ?150?ps before the main pulse has been obtained. The contrast level is the highest value achieved in Yb:YAG chirped-pulse amplification (CPA) laser system at 100?mJ level.  相似文献   

5.
Saikawa J  Fujii M  Ishizuki H  Taira T 《Optics letters》2006,31(21):3149-3151
We have demonstrated efficient, high-energy, narrow-spectral-bandwidth 2.128 microm pulse generation by use of periodically poled MgO:LiNbO3 devices with a 36 mm length and a 5 mm x 5 mm large aperture. A free-running degenerated optical parametric oscillator (OPO) pumped with a Q-switched 1.064 microm Nd:YAG laser exhibits a high slope efficiency of 75% and an optical-to-optical conversion efficiency of 70% with a broad spectral bandwidth (>100 nm). In a configuration with a spectrally narrowed master oscillator followed by a power amplifier, we have achieved an output pulse energy of 52 mJ with a spectral bandwidth of less than 2 nm at the degeneracy point. The total optical-to-optical conversion efficiency of the system reached 50%.  相似文献   

6.
We design a two-stage non-collinear optical parametric chirped pulse amplifier using BBO crystals for a high-power Ti:sapphire laser system, and numerically analyze the output characteristics of the OPCPA system. We find optimal phase-matching conditions and calculate the parametric gains as a function of pump intensity and interaction length. By constructing a two-stage OPCPA system using two BBO crystals, we obtain 12 mJ output energy corresponding to a high gain of 107, a pulse duration of 37 fs, and a contrast ratio of 5×10−8.  相似文献   

7.
A compact two-stage optical parametric chirped pulse amplifier based on photonic crystal fibre is demonstrated.A 1064-nm soliton pulse is obtained in a home-made photonic crystal fibre (PCF) with femtosecond pulse pumping and then amplified to 2 mJ in an Nd:YAG regenerative amplifier.After the amplified pulses pass through the LBO crystal,the 532-nm double-frequency light with an energy of 0.8 mJ and a duration of over 100 ps at 10-Hz repetition rate is generated as a pump source in the following two-stage optical parametric amplification (OPA).The 850-nm chirped signal light gain from the stretcher is 1.5×10 4 in the first-stage OPA while it is 120 in the second-stage OPA.The total signal gain of optical parametric chirped pulse amplification (OPCPA) can reach 1.8×10 6.  相似文献   

8.
We report a high-contrast, high-intensity Ti:sapphire chirped-pulse amplification system that incorporates a nonlinear preamplifier based on optical parametric chirped-pulse amplification (OPCPA). By cooling the Ti:sapphire crystal in the final amplifier down to 77 K, the chirped-pulses are amplified to 2.9 J at a 10 Hz repetition rate without a thermal lensing effect. Pulse compression down to 19 fs duration obtained after amplification indicates a peak power of 80 TW. With the OPCPA, the temporal contrast is significantly improved to better than 7x10(-9) in a few picoseconds interval prior to the main laser pulse.  相似文献   

9.
A diode-pumped actively Q-switched Nd:GdVO4 green laser with periodically poled KTP (PPKTP) and Acoustic-optic (AO) modulator has been realized. The dependences of pulse energy, pulse width, and peak power on incident pump power are measured. At the pump power of 4.1 W and repetition rate of 10 kHZ, we can obtain a 19.2 ns pulse with pulse energy of 0.11 mJ and peak power of 5.8 kW, which are almost three times of that in the conventional KTP green laser, respectively. A rate equation model is introduced to theoretically analyze the results obtained in the experiment, in which the Gaussian spatial distribution of the intracavity photon density is taken into account. The numerical solutions of the rate equations agree with the experimental results.  相似文献   

10.
We demonstrate a high-contrast, high-intensity double chirped-pulse amplification (CPA) Ti:sapphire laser system using an optical parametric chirped-pulse (OPCPA) pre- amplifier. By injecting cleaned microjoule seed pulses into the OPCPA, a temporal contrast greater than 1010 within picosecond times before the main femtosecond pulse is demonstrated with an output pulse energy of 1.7 J and a pulse duration of 30 fs, corresponding to a peak power of 60 TW at a 10 Hz repetition rate. This system uses a cryogenically-cooled Ti:sapphire final amplifier and generates focused peak intensities in excess of 1020 W/cm2.  相似文献   

11.
We report on a Yb:YAG Innoslab laser amplifier system for generation of subpicsecond high energy pump pulses for optical parametric chirped pulse amplification (OPCPA) at high repetition rates. Pulse energies of up to 20 mJ (at 12.5 kHz) and repetition rates of up to 100 kHz were attained with pulse durations of 830 fs and average power in excess of 200 W. We further investigate the possibility to use subpicosecond pulses to derive a stable continuum in a YAG crystal for OPCPA seeding.  相似文献   

12.
We report on optical parametric oscillators (OPOs) based on large aperture periodically poled KTiOPO4 (PPKTP) and RbTiOAsO4 (PPRTA) pumped with high pulse energy and high average power Q-switched solid-state lasers. The OPOs were pumped with 1064-nm pulses of a diode-pumped Nd:YVO4 laser at 20 kHz repetition rate. The emitted signal wavelengths were 1.72 μm and 1.58 μm and the idler wavelengths were 2.79 μm and 3.26 μm, respectively. Pumping the PPKTP OPO with 7.2 W and the PPRTA OPO with 8 W average power, 2 W and 1.3 W total OPO output powers were generated. Two-dimensional measurements of the total OPO output power, the signal wavelength and the signal bandwidth in dependence on the crystal location indicated a good uniformity of the quasiphasematching structure over the entire 3-mm-thick crystals. This allowed pumping with larger pump beams and therefore with pulse energies of tens of millijoules. Pumping with different flash-lamp-pumped lasers, good OPO performance and high output pulse energies could be achieved for all pump lasers. Maximum input pulse energies of 56 mJ gave output pulse energies of as much as 18 mJ. The temperature tuning behaviors of both OPOs were measured, showing excellent agreement with calculated temperature tuning curves. New equations for temperature dispersion in RTA are presented. These results show that large-aperture PPKTP and PPRTA crystals are well suited for tunable nanosecond OPO operation with multi-watt average pump power and several tens of millijoules pump pulse energies. Received: 7 September 2001 / Published online: 7 November 2001  相似文献   

13.
We report on compact eye-safe nanosecond laser sources emitting in the 1.5 μm wavelength range based on non-critically phase-matched parametric interaction in optical parametric oscillators (OPOs) with KTP and periodically poled KTP (PPKTP) crystals, pumped by the fundamental frequency of Nd:YAG lasers. As much as 250 μJ signal pulse energy at 1.5 μm wavelength, 6.5 ns FWHM pulse-width, has been obtained in a PPKTP-OPO, extracavity pumped by a Nd:YAG microlaser oscillator–amplifier at 650 μJ pump pulse energy, 8 ns pulse-width. A single signal pulse of 2.7-mJ output energy at 1.57 μm wavelength, less than 5 ns pulse-width, was generated in a KTP-OPO, intracavity pumped by a passively Q-switched Nd:YAG laser.  相似文献   

14.
We report on optical parametric oscillators (OPO's) based on periodically poled RbTiOAsO(4) (PP RTA), which are pumped by Q -switched solid-state lasers. With a diode-pumped Nd:YVO(4) laser (pulse energy, 800microJ ; pulse duration, 5.5 ns; repetition rate, 1 kHz) the PP RTA OPO generated 1.58-microm signal and 3.26-microm idler radiation with a signal pulse energy of 45microJ . The large aperture of 3 mmx3 mm of the PP RTA crystal also permitted OPO operation with pump pulse energies as high as 65 mJ, provided by a flash-lamp-pumped Q -switched Nd:YAG laser (pulse duration, 20 ns; repetition rate, 10 Hz). With this pump source the OPO generated signal pulse energies as high as 17 mJ, corresponding to an efficiency of 26%. The performance of this OPO shows that large-aperture PP RTA crystals are well suited for pulsed nanosecond OPO operation with pump pulse energies of tens of millijoules.  相似文献   

15.
The total pulse energy of the signal and idler in a near-degenerate type-I periodically poled KTiOPO4 (PPKTP) optical parametrical oscillator (OPO) was spectrally confined within a 2 nm spectral bandwidth at 2.13 μm. This was achieved by using a volume Bragg grating as the output coupler. Both the signal and the idler from the PPKTP OPO were then simultaneously used to pump a mid-infrared ZnGeP2 (ZGP) OPO. The 2 nm bandwidth was narrower than the ZGP crystal acceptance bandwidth and, thus, made efficient conversion in the second OPO possible. A total slope efficiency of 10% from 1.06 μm to the 3.5–5 μm region was demonstrated, generating 250 μJ in the mid-IR with only 3.6 mJ of 1.06 μm pump energy. This corresponds to a Nd:YAG pump to mid-IR conversion efficiency of 7%. PACS 42.65.Yj; 42.72.Ai; 42.40.Eq  相似文献   

16.
We theoretically investigated the temporal profile of a background pedestal in a single-stage optical parametric chirped pulse amplification (OPCPA) system, and showed that the amplified spontaneous emission (ASE) prepulse in the saturation regime degrades the contrast ratio. To improve the contrast ratio in a saturated OPCPA system, a method using pump pulse shaping and the time delay control between pump and seed pulses was utilized. Through numerical simulations, the effect of the rising time and the time delay of a pump pulse on the background pedestal was subsequently investigated in terms of the contrast ratio. From the simulation results, it was determined that an optimal rising time and the time delay of the pump pulse are critical for obtaining a high-contrast broadband laser pulse from a saturated OPCPA system.  相似文献   

17.
光参量啁啾脉冲饱和放大的增益稳定性   总被引:5,自引:5,他引:0       下载免费PDF全文
 光参量啁啾脉冲放大(OPCPA)在饱和放大区存在一个增益稳定点,据此设计了一个输出稳定的三级OPCPA系统;第一、二、三级分别选用准相位匹配的周期极化钛氧磷酸钾(PPKTP)晶体、LBO晶体和KDP晶体作为增益介质。饱和放大时,增益随泵浦光强度变化时的增益输出稳定性明显改善,在泵浦光强度抖动低于6%的情况下,各级光参量放大器OPA输出的增益抖动小于1%。前级采用准相位匹配的PPKTP晶体作为增益介质,在远低于破坏阈值的30MW/cm2的泵浦功率密度下,可得到2×105的饱和放大增益和20%的能量转换效率。  相似文献   

18.
Ishizuki H  Shoji I  Taira T 《Optics letters》2004,29(21):2527-2529
We have demonstrated high-energy quasi-phase-matched optical parametric oscillation in a 3-mm-thick periodically poled 5-mol. % MgO-doped LiNbO3 device with a 32.1-microm grating period and a 30-mm length. With a large-spot-size pump laser of 2.2-mm diameter, we obtained a total output pulse energy of 22 mJ for both the signal (wavelength 1.82 microm) and the idler (2.56 microm) waves at an input pump energy of 46 mJ.  相似文献   

19.
王河林  王承  冷雨欣  徐至展  候蓝田 《中国物理 B》2010,19(5):54212-054212
We report on the generation of a high energy and long pulse for pumping optical parametric chirped-pulse amplification (OPCPA) by a high-birefringence photonic crystal fibre (HB-PCF) and a laser-diode-pumped regenerative chirped pulse amplifier. Using the femtosecond pump pulse centred at 815~nm, a 1064~nm soliton pulse is produced in the HB-PCF. After injecting it into an Nd:YAG regenerative amplifier with the glass etalons, a narrow-band amplified pulse with an energy of $\sim $4~mJ and a duration of 235 ps is achieved at a repetition rate of 10~Hz, which is suitable for being used as a pump source in the 800~nm OPCPA system.  相似文献   

20.
We have demonstrated highly efficient broadband amplification by an optical parametric chirped pulse amplifier (OPCPA) system that uses high energy seed pulses. The OPCPA consists of three type I B-barium borate (BBO) crystals pumped by a Q-switched Nd:YAG laser. We successfully amplified the microjoule level seed pulses to 78 mJ with a pump-to-signal optical conversion efficiency of 26% at a 10 Hz repetition rate. To our knowledge these results represent the most optically efficient OPCPA to date pumped by a typical Q-switched laser.  相似文献   