首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Bicyclol is a synthetic drug widely used to treat chronic hepatitis B. This study aimed to develop a selective, sensitive and high‐throughput liquid chromatography–tandem mass spectrometric method for the detection of bicyclol in human plasma. Bicyclol was detected using a multiple reaction monitoring mode, with ammonium adduct ions (m/z 408.2) as the precursor ion and the [M‐CH3]+ ion (m/z 373.1) subjected to demethylation as the product ion. Chromatographic separation was achieved using a Zobax Eclipse XDB‐C18 column with a gradient elution and a mobile phase of 2 mm ammonium formate and acetonitrile. Bicyclol was extracted from plasma matrix by precipitation. A linear detection response was obtained for bicyclol ranging from 0.500 to 240 ng/mL, and the lower limit of quantification was 0.500 ng/mL. The intra‐ and inter‐day precisions were all ≤7.4%, and the accuracies were within ±6.0%. The extraction recovery was >95.9%, and the matrix effects were between 96.0% and 108%. Bicyclol was found to be unstable in human plasma at room temperature, but the degradation was minimized by conducting sample collection and preparation in an ice bath. The validated method was successfully applied to investigate the pharmacokinetics of bicyclol tablets in six healthy Chinese volunteers.  相似文献   

2.
We developed an analytical method using liquid–liquid extraction (LLE) and liquid chromatography–tandem mass spectrometry (LC‐MS/MS) to detect and quantify tebufenozide (TEB) and indoxacarb (IND) residues in animal and aquatic products (chicken muscle, milk, egg, eel, flatfish, and shrimp). The target compounds were extracted using 1% acetic acid (0.1% acetic acid for egg only) in acetonitrile and purified using n‐hexane. The analytes were separated on a Gemini‐NX C18 column using (a) distilled water with 0.1% formic acid and 5 mm ammonium acetate and (b) methanol with 0.1% formic acid as the mobile phase. All six‐point matrix‐matched calibration curves showed good linearity with coefficients of determination (R2) ≥0.9864 over a concentration range of 5–50 μg/kg. Intra‐ and inter‐day accuracy was expressed as the recovery rate at three spiking levels and ranged between 73.22 and 114.93% in all matrices, with a relative standard deviation (RSD, corresponding to precision) ≤13.87%. The limits of quantification (LOQ) of all target analytes ranged from 2 to 20 μg/kg, which were substantially lower than the maximum residue limits (MRLs) specified by the regulatory agencies of different countries. All samples were collected from different markets in Seoul, Republic of Korea, and tested negative for tebufenozide and indoxacarb residues. These results show that the method developed is robust and may be a promising tool to detect trace levels of the target analytes in animal products.  相似文献   

3.
Acrylamide levels over a wide range of different food products were analysed using both liquid chromatography–tandem mass spectrometry (HPLC–MS–MS) and gas chromatography–tandem mass spectrometry (GC–MS–MS). Two different sample preparation methods for HPLC–MS–MS analysis were developed and optimised with respect to a high sample throughput on the one hand, and a robust and reliable analysis of difficult matrices on the other hand. The first method is applicable to various foods like potato chips, French fries, cereals, bread, and roasted coffee, allowing the analysis of up to 60 samples per technician and day. The second preparation method is not as simple and fast but enables analysis of difficult matrices like cacao, soluble coffee, molasses, or malt. In addition, this method produces extracts which are also well suited for GC–MS–MS analysis. GC–MS–MS has proven to be a sensitive and selective method offering two transitions for acrylamide even at low levels up to 1 μg kg−1. For the respective methods the repeatability (n=10), given as coefficient of variation, ranged from 3% (acrylamide content of 550 μg kg−1) to 12% (acrylamide content of 8 μg kg−1) depending on the food matrix. The repeatability (n=3) for different food samples spiked with acrylamide (5–1500 μg kg−1) ranged from 1 to 20% depending on the spiking level and the food matrix. The limit of quantification (referred to a signal-to-noise ratio of 9:1) was 30 μg kg−1 for HPLC–MS–MS and 5 μg kg−1 for GC–MS–MS. It could be demonstrated that measurement uncertainties were not only a result of analytical variability but also of inhomogeneity and stability of the acrylamide in food.  相似文献   

4.
Nitazoxanide (NTZ) is a broad‐spectrum antimicrobial agent. Tizoxanide (T) and tizoxanide glucuronide (TG) are the major circulating metabolites after oral administration of NTZ. A rapid and specific LC–MS/MS method for the simultaneous quantification of T and TG in mouse plasma was developed and validated. A simple acetonitrile‐induced protein precipitation method was employed to extract two analytes and the internal standard glipizide from 50 μL of mouse plasma. The purified samples were resolved using a C18 column with a mobile phase consisting of acetonitrile and 5 mm ammonium formate buffer (containing 0.05% formic acid) following a gradient elution. An API 3000 triple quadrupole mass spectrometer was operated under multiple reaction‐monitoring mode with electrospray ionization. The precursor‐to‐product ion transitions m/z 264 → m/z 217 for T and m/z 440 → m/z 264 for TG were used for quantification. The developed method was linear in the concentration ranges of 1.0–500.0 ng/mL for T and 5.0–1000.0 ng/mL for TG. The intra‐ and inter‐day precision and accuracy of the quality control samples at low, medium and high concentrations exhibited an RSD of <13.2% and the accuracy values ranged from ?9.6 to 9.3%. We used this validated method to study the pharmacokinetics of T and TG in mice following oral administration of NTZ. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

5.
An analytical approach using a modified quick, easy, cheap, effective, rugged, and safe extraction method followed by liquid chromatography with electrospray ionization tandem mass spectrometry was developed herein for the determination of artesunate and its metabolite, dihydroarteminsinin in porcine muscle, egg, eel, flatfish, and shrimp. 10% trichloroacetic acid in acetonitrile mixed with ethyl acetate was used as an extraction solvent. To obtain a good separation, a Phenomenex Kinetex reversed‐phase analytical column was selected with mobile phase consisting of distilled water (A) and acetonitrile (B), both containing 0.05% formic acid. Good linearity was achieved using matrix‐matched calibrations constructed from six concentrations (5–50 μg/kg) with determinant coefficients ≥0.9918. Recoveries estimated from three spiking concentrations (5, 10, and 20 μg/kg) ranged between 71.3 and 104.7% in all matrixes with relative standard deviations ≤8.3%. A variety of samples purchased from markets in Seoul were tested following the protocol described herein. The artesunate and dihydroarteminsinin were not detected in any matrix. The methodology proposed could be used for routine determination of artesunate and its metabolite, dihydroartemisinin in various animal products having variable percentages of fat and protein.  相似文献   

6.
Ketamine is an N‐methyl‐d ‐aspartate receptor antagonist that is usually used clinically as a racemic mixture. Its two enantiomers exhibit different pharmacological activities. To determine whether the enantiomers have different pharmacokinetic profiles, a chiral liquid chromatography–tandem mass spectrometry method was developed and validated for the determination of ketamine enantiomers in dog plasma. The enantiomers of ketamine were extracted from 50 μL of plasma by methyl tert‐butyl ether. Adequate chromatographic retention and baseline resolution of the enantiomers were achieved within a runtime of 5 min on a chiral column coated with polysaccharide derivatives, using a gradient mobile phase of acetonitrile and 10 mm ammonium bicarbonate aqueous solution. Ketamine enantiomers were detected by mass spectrometry with multiple reaction monitoring mode using the transitions of m/z 238.3 → 125.9 for the analytes and m/z 237.1 → 194.1 for carbamazepine (internal standard). The method was linear over the concentration range from 0.5 to 500 ng/mL for each enantiomer. The lower limit of quantification (LLOQ) for each enantiomer was 0.5 ng/mL. The intra‐ and inter‐day precision was <7.3% and 8.5% for R‐ and S‐ketamine, respectively. The accuracy was 92.9–110.4% for R‐ketamine and 99.8–102.4% for S‐ketamine. The method was successfully applied to characterize the stereoselective pharmacokinetic profiles of ketamine in beagle dogs.  相似文献   

7.
A simple and rapid method for enantioselective determination of dufulin in cucumber and soil was developed by liquid chromatography with tandem mass spectrometry. The enantiomers were separated on a Superchiral S‐OD chiral cellulose tris(3,5‐dimethylphenylcarbamate) column at 20°C, with a mixture of acetonitrile and water (0.1% formic acid; 52:48, v/v) as mobile phase at a flow rate of 0.65 mL/min. The pretreatment conditions were optimized using an orthogonal test, and the optimized method showed good linearity and sensitivity. The limits of detection and limits of quantification of two dufulin enantiomers were 0.006 and 0.02 mg/kg, respectively. The average recoveries of S‐enantiomer and R‐enantiomer in cucumber and soil were 80.61–99.83% and 80.97–102.96%, respectively, with relative standard deviations of 1.30–9.72%. The method was successfully applied to determine dufulin in real cucumber and soil samples. The results demonstrate that the method could facilitate further research on the differences between individual dufulin enantiomers with respect to metabolites and environmental fate and finally help reveal the complex interactions that exist between dufulin, humans and the environment.  相似文献   

8.
Amitriptyline (AMI) has been in use for decades in treating depression and more recently for the management of neuropathic pain. A highly sensitive and specific LC–tandem mass spectrometry method was developed for simultaneous determination of AMI, its active metabolite nortriptyline (NOR) and their hydroxy‐metabolites in human serum, using deuterated AMI and NOR as internal standards. The isobaric E‐10‐hydroxyamitriptyline (E‐OH AMI), Z‐10‐hydroxyamitriptyline (Z‐OH AMI), E‐10‐hydroxynortriptyline (E‐OH NOR) and Z‐10‐hydroxynortriptyline (Z‐OH NOR), together with their parent compounds, were separated on an ACE C18 column using a simple protein precipitation method, followed by dilution and analysis using positive electrospray ionisation with multiple reaction monitoring. The total run time was 6 min with elution of E‐OH AMI, E‐OH NOR, Z‐OH AMI, Z‐OH NOR, AMI (+ deuterated AMI) and NOR (+ deuterated NOR) at 1.21, 1.28, 1.66, 1.71, 2.50 and 2.59 min, respectively. The method was validated in human serum with a lower limit of quantitation of 0.5 ng/mL for all analytes. A linear response function was established for the range of concentrations 0.5–400 ng/mL (r2 > .999). The practical assay was applied on samples from patients on AMI, genotyped for CYP2C19 and CYP2D6, to understand the influence of metaboliser status and concomitant medication on therapeutic drug monitoring.  相似文献   

9.
An LC–MS/MS method was developed and validated for bioanalysis of clofazimine in human dried blood spot (DBS) samples in support of a clinical study on multidrug‐resistant tuberculosis in developing countries. The validated assay dynamic range was from 10.0 to 2000 ng/mL using a 1/8 inch DBS punch. The accuracy and precision of the assay were ±11.0% (bias) and ≤13.5% (CV) for the LLOQs (10.0 ng/mL) and ±15% (bias) and ≤15% (CV) for all other QC levels. The assay was proved to be free from the possible impact owing to spot size and storage temperature (e.g. at 60°C, ≤ − 60°C). The validated assay is well suited for the intended clinical study where conventional pharmacokinetic sample collection is not feasible.  相似文献   

10.
A rapid, simple and sensitive LC–MS/MS method was established and validated for simultaneous quantification of ticagrelor and its active metabolite AR‐C124910XX in human plasma. After plasma samples were deproteinized with acetonitrile, the post‐treatment samples were chromatographed on a Dikma C18 column interfaced with a triple quadrupole tandem mass spectrometer. Electrospray negative ionization mode and multiple reaction monitoring were adopted to assay ticagrelor and AR‐C124910XX. Acetonitrile and 5 mΜ ammonium acetate was used as the mobile phase with a gradient elution at a flow rate of 0.5 mL/min. The method was linear in the range of 0.781–800 ng/mL for both ticagrelor and AR‐C124910XX with a correlation coefficient ≥0.994. The intra‐ and inter‐day precisions were within 12.61% in terms of relative standard deviation and the accuracy was within ±7.88% in terms of relative error. The LC–MS/MS method was fully validated for its sensitivity, selectivity, stability, matrix effect and recovery. This convenient and specific LC–MS/MS method was successfully applied to the pharmacokinetic study of ticagrelor and AR‐C124910XX in healthy volunteers after an oral dose of 90 mg ticagrelor.  相似文献   

11.
Liquid chromatography, coupled with tandem mass spectrometry, presents a powerful tool for the quantification of the sex steroid hormones 17‐β estradiol, progesterone and testosterone from biological matrices. The importance of accurate quantification with these hormones, even at endogenous levels, has evolved with our understanding of the role these regulators play in human development, fertility and disease risk and manifestation. Routine monitoring of these analytes can be accomplished by immunoassay techniques, which face limitations on specificity and sensitivity, or using gas chromatography–mass spectrometry. LC–MS/MS is growing in capability and acceptance for clinically relevant quantification of sex steroid hormones in biological matrices and is able to overcome many of the limitations of immunoassays. Analyte specificity has improved through the use of novel derivatizing agents, and sensitivity has been refined through the use of high‐resolution chromatography and mass spectrometric technology. This review highlights these innovations, among others, in LC–MS/MS steroid hormone analysis captured in the literature over the last decade.  相似文献   

12.
张科明  梁飞燕  邓鸣  刘向红  许杨彪  赵庄 《色谱》2016,34(9):860-867
采用改进的QuEChERS方法提取和净化猪肉样品,建立了同时测定磺胺类、磺胺类增效剂、β-受体激动剂、四环素类、喹诺酮类、金刚烷胺和性激素共7类35种兽药残留的液相色谱-串联质谱(LC-MS/MS)检测方法。样品经 Na2EDTA(乙二胺四乙酸)-Mcllvaine缓冲液-2.5%(体积分数)乙酸乙腈溶液提取,提取液经盐析后取乙腈相,用氨基(NH2)吸附剂分散固相萃取净化后,在电喷雾离子源正离子多反应监测(MRM)模式下进行测定,基质外标法定量。35种兽药在1.0~50.0 μg/L范围内线性关系良好,相关系数均大于0.996。在3个不同添加水平下的平均回收率为71.8%~113.5%,相对标准偏差为0.6%~9.8%(n=6),检出限和定量限分别为0.01~1.01 μg/kg和0.04~3.37 μg/kg。该方法操作简单,净化效果好,灵敏度高,适用于猪肉中兽药多残留的同时快速定性、定量分析。  相似文献   

13.
Several chemical and biological studies have revealed R,S‐goitrin as the main bioactive constituent of Isatis indigotica Fort., responsible for antiviral antiendotoxin activity; however, few pharmacokinetic studies have been conducted. To comprehend the kinetics of R,S‐goitrin and promote its curative application, a rapid and sensitive UHPLC–MS/MS method was developed. The selected reaction monitoring transitions were m/z 130.0 → 70.0 for R,S‐goitrin and m/z 181.1 → 124.0 for the internal standard in a positive‐ion mode. The established UHPLC–MS/MS method achieved good linearity for R,S‐goitrin at 10–2000 ng/mL. The intra‐ and interday accuracy levels were within ±9.7%, whereas the intraday and interday precision levels were <11.3%. The extraction recovery, stability and matrix effect were within acceptable limits. The validated method was successfully applied for the pharmacokinetic analysis of R,S‐goitrin in rats after oral administration. Moreover, a total of six metabolites were structurally identified through UHPLC–Q/TOF–MS. The proposed metabolic pathways of R,S‐goitrin in rats involve demethylation, acetylation, glutathionylation and oxygenation.  相似文献   

14.
A highly sensitive liquid chromatography–tandem mass spectrometry method was developed and validated for the determination of limonin in beagle dog plasma using nimodipine as internal standard. The analyte and internal standard (IS) were extracted with ether followed by a rapid isocratic elution with 10 mm ammonium acetate buffer–methanol (26:74, v/v) on a C18 column (150 × 2.1 mm i.d.) and subsequent analysis by mass spectrometry in the multiple reaction monitoring mode. The precursor to product ion transitions of m/z 469.4 → 229.3 and m/z 417.2 → 122.0 were used to measure the analyte and the IS. The assay was linear over the concentration range of 0.625–100 ng/mL for limonin in dog plasma. The lower limit of quantification was 0.312 ng/mL and the extraction recovery was >90.4% for limonin. The inter‐ and intra‐day precision of the method at three concentrations was less than 9.9%. The method was successfully applied to pharmacokinetic study of limonin in dogs. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

15.
As a suitable way for routine screening of pesticides and control of other organic contaminants in water, the combination of liquid chromatography triple quadrupole tandem mass spectrometry (LC–QqQ-MS/MS) and liquid chromatography–hybrid quadrupole time-of-flight mass spectrometry (LC–QTOF-MS) has been applied to the analysis of 63 surface and waste water samples after conventional solid-phase extraction (SPE). The extracts were screened for 43 pesticides or degradation products by LC–QqQ-MS/MS achieving limits of detection (LOD) ranged from 0.04 to 2 ng L−1. Of the 43 selected pesticides, 33 were detected in water samples. The ESI–QTOF MS instrument was run using two simultaneous acquisition functions with low and high collision energy (MSE approach) and acquiring the full mass spectra. A home-made database containing more than 1100 organic pollutants was used for substance identification. Around 250 of these compounds were available at the laboratory as reference standards. Five pesticides and 3 of their degradation products, different to those selected in the QqQ method, were detected by QqTOF-MS. Thirteen pharmaceuticals and two drugs of abuse were also identified in the samples. In practice, the sample preparation proved to be suitable for both techniques and for a wide variety of substances with different polarity. Mutual confirmation and evidence of co-occurrence of several other organic contaminants were the main advantages of the combination of both techniques.  相似文献   

16.
A sensitive and reliable LC‐ESI‐MS method for the determination of salvianolic acid C in rat plasma has been developed and validated. Plasma samples were prepared by liquid–liquid extraction with ethyl acetate and separated on a Zorbax SB‐C18 column (3.5 µm, 2.1 × 100 mm) at a flow rate of 0.3 mL/min using acetonitrile–water as mobile phase. The detection was carried out by a single quadrupole mass spectrometer with electrospray ionization source and selected ion monitoring mode. Linearity was obtained for salvianolic acid C ranging from 5 to 1000 ng/mL. The intra‐ and inter‐day precisions (RSD, %) didn't exceed 9.96%, and the accuracy (RE, %) were all within ±3.64%. The average recoveries of the analyte and internal standard were >89.13%. Salvianolic acid C was proved to be stable during all sample storage, preparation and analytic procedures. The validated method was successfully applied to pharmacokinetic study after oral and intravenous administration of salvianolic acid C to rats. The absolute oral bioavailability of salvianolic acid C was 0.29 ± 0.05%. This method was further applied to simultaneous determination of salvianolic acid A, salvianolic acid B and salvianolic acid C in rat plasma and showed good practicability. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

17.
In this study, an analytical method was developed for quantification of residues of the anthelmintic drug phenothiazine (PTZ) in pork muscle using liquid chromatography–tandem mass spectrometry. Muscles were extracted using 0.2% formic acid and 10 mm ammonium formate in acetonitrile, defatted and purified using n ‐hexane. The drug was well separated on a Waters XBridge™ C18 analytical column using a binary solvent system consisting of 0.2% formic acid and 10 mm ammonium formate in ultrapure water (A) and acetonitrile (B). Good linearity was achieved over a six‐point concentration range in matrix‐matched calibration with determination coefficient =0.9846. Fortified pork muscle having concentrations equivalent to and double the limit of quantification (1 ng/g) yielded recovery ranges between 100.82 and 104.03% and relative standard deviations <12%. Samples (n = 5) collected from large markets located in Seoul City tested negative for PTZ residue. In conclusion, 0.2% formic acid and ammonium formate in acetonitrile can effectively extract PTZ from pork muscle without solid‐phase extraction, a step normally required for cleanup before analysis and the validated method can be used for routine analysis to ensure the quality of animal products.  相似文献   

18.
A rapid, selective and sensitive liquid chromatography–tandem mass spectrometry assay method was developed for simultaneous determination of ambroxol and salbutamol in human plasma using citalopram hydrobromide as internal standard (IS). The sample was alkalinized with ammonia water (33:67, v/v) and extracted by single liquid–liquid extraction with ethyl acetate. Separation was achieved on Waters Acquity UPLC BEH C18 column using a gradient program at a flow rate of 0.2 mL/min. Detection was performed using electrospray ionization in positive ion multiple reaction monitoring mode by monitoring the ion transitions m/z 378.9 → 263.6 (ambroxol), m/z 240.2 → 147.7 (salbutamol) and m/z 325.0 → 261.7 (IS). The total analytical run time was relatively short (3 min). Calibration curves were linear in the concentration range of 0.5–100.0 ng/mL for ambroxol and 0.2–20.0 ng/mL for salbutamol, with intra‐ and inter‐run precision (relative standard deviation) <15% and accuracy (relative error) ranging from 97.7 to 112.1% for ambroxol and from 94.5 to 104.1% for salbutamol. The method was successfully applied in a clinical pharmacokinetic study of the compound ambroxol and salbutamol tablets.  相似文献   

19.
A sensitive and specific liquid chromatographic–tandem mass spectrometric (LC–MS–MS) method for most of those penicillins and cephalosporins for which EU maximum residue limits (MRL) were set in Council regulation (EEC) 2377/90 was developed and validated in bovine muscle, kidney and milk. The analytes were extracted with acetonitrile/water and cleaned-up by a single reversed-phase solid-phase extraction step. Highest sensitivity for the analytes was obtained when amoxicillin, ampicillin, cephalexin, cephapirin, desacetylcephapirin, cephalonium, cefquinome and cefazolin were measured in the positive electrospray ionisation mode (ESI (+)) and cefoperazone, benzylpenicillin, phenoxymethylpenicillin, oxacillin, cloxacillin, dicloxacillin and nafcillin in the negative electrospray ionisation mode (ESI (−)). Chromatography was performed with a formic acid/methanol gradient. Collision-induced dissociation (CID) with argon was used for fragmentation of the pseudomolecular ions to achieve the required specificity. Possible adverse matrix effects on the electrospray ionisation process caused by co-eluting matrix components were investigated. The method was validated closely to the new EU guidelines and applied to positively screened samples from official food control allowing the identification and quantification of the residual β-lactams.  相似文献   

20.
The aim of this study was to develop and validate fully the liquid chromatography–tandem mass spectrometry method for free mycophenolic acid (MPA) concentration measurements in plasma ultrafiltrate that will be reliable and simple in preparation with deuterated MPA (MPA‐d3) chosen as an internal standard. The chromatographic separation was made with Zorbax Eclipse XDB‐C18 column (4.6 × 150 mm) using a gradient of two solutions as a mobile phase: (A) water and (B) methanol, each containing 0.1% formic acid and 2.5 mm ammonium acetate. Satisfactory repeatability of retention times was achieved with average values of 7.54 ± 0.20 min and 7.50 ± 0.19 min for MPA and MPA‐d3, respectively. The method was selective, with no carry‐over or matrix effect observed. The analytical range was proven for MPA ultrafiltrate concentrations of 1–500 ng/mL. The accuracy and precision fell within the acceptance criteria for intraday (accuracy: 100.63–110.46%, imprecision: 6.23–7.76%), as well as interday assay (accuracy: 98.81–110.63%; imprecision: 5.36–10.22%). The method was used for free MPA determination in plasma samples from patients treated with mycophenolate mofetil. To the best of our knowledge this is the first liquid chromatography–tandem mass spectrometry method for free MPA monitoring using MPA‐d3 that allows to measure plasma ultrafiltrate concentrations as low as 1 ng/mL.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号