首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Betahistine is widely used for the treatment of vertigo. Owing to first‐pass metabolism, 2‐pyridyl acetic acid (2PAA, major metabolite of betahistine) was considered as surrogate for quantitation. A specific and sensitive LC–MS/MS method was developed and validated for quantitation of 2PAA using turbo‐ion spray in a positive ion mode. A solid‐phase extraction was employed for the extraction of 2PAA and 2PAA d6 (IS) from human plasma. Chromatographic separation of analytes was achieved using an ACE CN, 5 μm (50 × 4.6 mm) column with a gradient mobile phase comprising acetonitrile–methanol (90:10% v /v) and 0.7% v/v formic acid in 0.5 mm ammonium trifluoroacetate in purified water (100% v/v). The retention times of 1.15 and 1.17 min for 2PAA and internal standard, respectively, were achieved. Quantitation of 2PAA and internal standard was achieved by monitoring multiple reaction monitoring transition pairs (m /z 138.1 to m /z 92.0 and m /z 142.1 to m /z 96.1, respectively). The developed method was validated for various parameters. The calibration curves of 2PAA showed linearity from 5.0 to 1500 ng/mL, with a lower limit of quantitation of 5.0 ng/mL. The bias and precision for inter‐ and intra‐batch assays were <10%. The developed method was used to support clinical sample analysis.  相似文献   

2.
Propafenone, a class Ic antiarrhythmic agent, is metabolized to 5‐hydroxypropafeone (5‐OHP) and N‐depropylpropafenone (NDPP). Simultaneous determination of serum propafenone and its metabolites was performed using HPLC equipped with a conventional octadecylsilyl silica column and ultraviolet detector. The wavelength was set at 250 nm. Propafenone and its metabolites in the serum were extracted using diethyl ether. The mobile phase solution, comprising 1‐pentanesulfonic acid sodium salt (0.1 m ), acetonitrile and acetic acid (280:185:2.5, v/v/v), was pumped at a flow rate of 1 mL/min. The recoveries of propafenone, 5‐OHP and NDPP were greater than 85, 82 and 60%, respectively, with the coefficients of variation (CVs) less than 5.4, 1.9 and 2.9%, respectively. The calibration curves were linear for a concentration range of 12.5–1500 ng/mL for propafenone and 2–500 ng/mL for 5‐OHP and NDPP (r > 0.999). CVs in the intraday assays were 1.0–3.8% for propafenone, 0.6–2.0% for 5‐OHP and 0.6–1.7% for NDPP. CVs in interday assays were 1.3–7.7% for propafenone, 1.1–6.5% for 5‐OHP and 5.4–8.0% for NDPP. The present HPLC method can be used to assess the disposition of propafenone and its metabolites for pharmacokinetic studies and therapeutic drug monitoring of propafenone.  相似文献   

3.
A sensitive and specific LC–MS/MS assay for determination of β ‐eudesmol in rat plasma was developed and validated. After liquid–liquid extraction with ethyl ether , the analyte and IS were separated on a Capcell Pak C18 column (50 × 2.0 mm, 5 μm) by isocratic elution with acetonitrile—water–formic acid (77.5:22.5:0.1, v /v/v) as the mobile phase at a flow rate of 0.4 mL/min. An ESI source was applied and operated in positive ion mode; a selected reaction monitoring scan was used for quantification by monitoring the precursor–product ion transitions of m/z 245.1 → 163.1 for β ‐eudesmol and m/z 273.4 → 81.2 for IS. Good linearity was observed in the concentration range of 3–900 ng/mL for β ‐eudesmol in rat plasma. Intra‐ and inter‐day precision and accuracy were both within ±14.3%. This method was applied for pharmacokinetic studies after intravenous bolus of 2.0 mg/kg or intragastric administration of 50 mg/kg β ‐eudesmol in rats.  相似文献   

4.
A rapid and highly specific assay was developed and validated for the estimation of ZYDPLA1 in rat plasma using liquid chromatography coupled to tandem mass spectrometry with positive electrospray ionization. Method validation comprised of parameters such as specificity, matrix effect, precision, accuracy, recovery, stability, etc. The assay procedure involved a simple protein precipitation of ZYDPLA1 and alprazolam (internal standard) from rat plasma using acetonitrile. Chromatographic separation was achieved with a gradient mobile phase comprising: (A) 0.2% ammonia in purified water; (B) 0.1% formic acid in isopropyl alcohol/methanol (1: 1 v /v); and (C) acetonitrile at a flow rate of 1 mL/min on an ACE‐5, C18 (4.6 × 50 mm) column with a run time of 5.5 min. The quantitation of ZYDPLA1 was achieved by the summation of four multiple reaction mode transitions (m/z 399.7 → 383.0, 399.7 → 276.10, 399.7 → 153.20 and 399.7 → 127.20), while that of the internal standard was by a single multiple reaction mode transition (m/z 309.10 → 281.00). The lower limit of quantitation achieved was 0.01 μg/mL and the method showed linearity from 0.01 to 25 μg/mL. The intra‐ and inter‐day precision (%CV) of the quality control samples was within 8.81% and accuracy was ±10% of nominal values. This novel method was applied for evaluation of toxicokinetics of ZYDLA1 in rats.  相似文献   

5.
A simple, selective and reliable LC‐MS/MS method was validated for simultaneous quantitation of darolutamide diastereomers in 50 μL mouse plasma using warfarin as an internal standard (IS) as per regulatory guidelines. Plasma samples were extracted by liquid–liquid extraction and the chromatographic separation was achieved on a Chiralpak IA column with an isocratic mobile phase 5 mm ammonium acetate–absolute alcohol (20:80, v/v) at a flow rate of 1.0 mL/min. Detection and quantitation was done in multiple reaction monitoring mode following the transitions m/z 397 → 202 and 307 → 250 for darolutamide diastereomers and the IS, respectively, in the negative ionization mode. The linearity range was 100–2400 ng/mL for each diastereomer. The intra‐ and inter‐day precisions were in the ranges of 1.78–4.20 and 4.34–14.6, and 3.63–4.74 and 4.78–5.15 for diastereomer‐1 and diastereomer‐2, respectively. Both diastereomers were found to be stable under different stability conditions. The validated method was applied to a pharmacokinetic study in mice. Following oral administration of darolutamide at 10 mg/kg, maximum concentration in plasma was 4189 and 726 ng/mL for diastereomer‐1 and diastereomer‐2, respectively. The terminal half‐life was found to be ~0.50 h for both the diastereomers. The AUC(0–t) was found to be 18,961 ng*h/mL for diastereomer‐1 and 1340 ng*h/mL diastereomer‐2.  相似文献   

6.
A simple, specific and sensitive LC‐MS/MS method was developed and validated for the simultaneous determination of metoprolol (MET), α‐hydroxymetoprolol (HMT) and O‐desmethylmetoprolol (DMT) in rat plasma. The plasma samples were prepared by protein precipitation, then the separation of the analytes was performed on an Agilent HC‐C18 column (4.6 × 250 mm, 5 µm) at a flow rate of 1.0 mL/min, and post‐column splitting (1:4) was used to give optimal interface flow rates (0.2 mL/min) for MS detection; the total run time was 8.5 min. Mass spectrometric detection was achieved using a triple‐quadrupole mass spectrometer equipped with an electrospray source interface in positive ionization mode. The method was fully validated in terms of selectivity, linearity, accuracy, precision, stability, matrix effect and recovery over a concentration range of 3.42–7000 ng/mL for MET, 2.05‐4200 ng/mL for HMT and 1.95‐4000 ng/mL for DMT. The analytical method was successfully applied to herb–drug interaction study of MET and breviscapine after administration of breviscapine (12.5 mg/kg) and MET (40 mg/kg). The results suggested that breviscapine have negligible effect on pharmacokinetics of MET in rats; the information may be beneficial for the application of breviscapine in combination with MET in clinical therapy. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

7.
Amitriptyline (AMI) has been in use for decades in treating depression and more recently for the management of neuropathic pain. A highly sensitive and specific LC–tandem mass spectrometry method was developed for simultaneous determination of AMI, its active metabolite nortriptyline (NOR) and their hydroxy‐metabolites in human serum, using deuterated AMI and NOR as internal standards. The isobaric E‐10‐hydroxyamitriptyline (E‐OH AMI), Z‐10‐hydroxyamitriptyline (Z‐OH AMI), E‐10‐hydroxynortriptyline (E‐OH NOR) and Z‐10‐hydroxynortriptyline (Z‐OH NOR), together with their parent compounds, were separated on an ACE C18 column using a simple protein precipitation method, followed by dilution and analysis using positive electrospray ionisation with multiple reaction monitoring. The total run time was 6 min with elution of E‐OH AMI, E‐OH NOR, Z‐OH AMI, Z‐OH NOR, AMI (+ deuterated AMI) and NOR (+ deuterated NOR) at 1.21, 1.28, 1.66, 1.71, 2.50 and 2.59 min, respectively. The method was validated in human serum with a lower limit of quantitation of 0.5 ng/mL for all analytes. A linear response function was established for the range of concentrations 0.5–400 ng/mL (r2 > .999). The practical assay was applied on samples from patients on AMI, genotyped for CYP2C19 and CYP2D6, to understand the influence of metaboliser status and concomitant medication on therapeutic drug monitoring.  相似文献   

8.
Triptolide is one of the main active ingredients of Tripterygium wilfordii Hook. F. In this study, a sensitive LC–MS/MS method was established and validated to determine the concentration of triptolide in rat plasma. Triptolide and an internal standard [(5R)‐5‐hydroxytriptolide] were extracted from 100 μL of rat plasma with acetonitrile, and the dried residue was then reconstituted and reacted with benzylamine to produce benzylamine triptolide and benzylamine (5R)‐5‐hydroxytriptolide. Derivatization increased the sensitivity of triptolide detection by ~100‐fold. Quantification was performed using a QTRAP 5500 tandem mass spectrometer with positive electrospray ionization in multiple reaction monitoring mode with an ion transition m/z 468.5 → 192.0 for benzylamine triptolide and m/z 484.3 → 192.1 for benzylamine (5R)‐5‐hydroxytriptolide. Good linearity was observed in the range of 0.030–100 ng/mL with a lower limit of quantitation of 0.030 ng/mL. The intra‐ and inter‐day precision was <6.5%, and the accuracy ranged from ?11.7 to ?4.4%. The recovery remained consistent and was reproducible at different concentrations. This method was successfully applied to the study of triptolide drug–drug interactions in Sprague–Dawley rats. With the use of itraconazole (40 mg/kg, p.o.) as a CYP3A inhibitor, the plasma exposure of triptolide in rats was increased by 36%.  相似文献   

9.
A simple, sensitive and specific UHPLC–MS/MS method for quantification of plantagoguanidinic acid (PGA) in rat plasma was applied to investigate the pharmacokinetic behavior in vivo , using protopine as internal standard. The chromatography was separated on a Phenomenex® Luna‐C18 column (2.1 × 150 mm, 3.0 μm) within 7.0 min using a mobile phase consisting of acetonitrile–0.1% formic acid solution under gradient elution at a flow rate of 0.4 mL/min. Prepared samples were monitored by multiple reaction monitoring mode, with the target fragmentions m/z 226.2 → 84.2 for PGA and m/z 354.2 → 188.9 for IS in positive electrospray ionization. The calibration curve of PGA was linear throughout the range 1–1000 ng/mL (r = 0.9962). The lower limit of quantitation in plasma for PGA was 0.1 ng/mL, and the recovery was >88.6%. Intra‐ and interday accuracy ranged from −8.6 to 4.9%. Furthermore, this validated method was successfully used for a pre‐clinical pharmacokinetic study of PGA at a single dose of 20 and 5 mg/kg in rats via oral and intravenous administration. The study showed that PGA was absorpted rapidly and eliminated gradually with a greater absolute oral bioavailability of 70.1% in rats.  相似文献   

10.
A simple, rapid and sensitive LC‐MS/MS method was developed and validated for the determination of free quercetin in rat plasma, using fisetin as internal standard. The detection was performed by negative ion electrospray ionization under selected reaction monitoring. Chromatographic separation (isocratic elution) was carried out using acetonitrile–10 m m ammonium formate (80:20, v/v) with 0.1% v/v formic acid. The lower limit of quantification (4.928 ng/mL) provided high sensitivity for the detection of quercetin in rat plasma. The linearity range was from 5 to 2000 ng/mL. Intra‐ and inter‐day variability (RSD) of quercetin extraction from rat plasma was <4.19 and 1.37% with accuracies of 98.77 and 99.67%. The method developed was successfully applied for estimating free quercetin in rat plasma, after oral administration of quercetin‐loaded biodegradable nanoparticles (QLN) and quercetin suspension. QLN (Cmax, 1277.34 ± 216.67 ng/mL; AUC, 17,458.25 ± 3152.95 ng hr/mL) showed a 5.38‐fold increase in relative bioavailability as compared with quercetin suspension (Cmax, 369.2 ± 108.07 ng/mL; AUC, 3276.92 ± 396.67 ng hr/mL). Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

11.
A specific and rapid liquid chromatography–tandem mass spectrometry method is proposed for the simultaneous determination of metformin (MET), saxagliptin (SAXA) and its active metabolite, 5‐hydroxy saxagliptin (5‐OH SAXA) in human plasma. Sample preparation was accomplished from 50 μL plasma sample by solid‐phase extraction using sodium dodecyl sulfate as an ion‐pair reagent. Reversed‐phase chromatographic resolution of analytes was possible within 3.5 min on ACE 5CN (150 × 4.6 mm, 5 μm) column using acetonitrile and10.0 mm ammonium formate buffer, pH 5.0 (80:20, v /v) as the mobile phase. Triple quadrupole mass spectrometric detection was performed using electrospray ionization in the positive ionization mode. The calibration curves showed good linearity (r 2 ≥ 0.9992) over the established concentration range with limit of quantification of 1.50, 0.10 and 0.20 ng/mL for MET, SAXA and 5‐OH SAXA respectively. The extraction recoveries obtained from spiked plasma samples were highly consistent for MET (75.12–77.84%), SAXA (85.90–87.84%) and 5‐OH SAXA (80.32–82.69%) across quality controls. The validated method was successfully applied to a bioequivalence study with a fixed‐dose formulation consisting of 5 mg SAXA and 500 mg MET in 18 healthy subjects. The reproducibility of the assay was demonstrated by reanalysis of 87 incurred samples.  相似文献   

12.
Dextromethorphan is used as a probe drug for assessing CYP2D6 and CYP3A4 activity in vivo and in vitro. A SIM GC/MS method without derivatization for the simultaneous determination of dextromethorphan and its metabolites, dextrorphan, 3‐methoxymorphinan and 3‐hydroxymorphinan, in human plasma, urine and in vitro incubation matrix was developed and validated. Calibration curves indicated good linearity with a coefficient of variation (r) better than 0.995. The lower limit of quantitation was found to be 10 ng/mL for all analytes in all matrices. Intra‐day and inter‐day precision for dextromethorphan and its metabolites was better than 9.02 and 9.91%, respectively and accuracy ranged between 91.76 and 106.27%. Recovery for dextromethorphan, its metabolites and internal standard levallorphan was greater than 72.68%. The method has been successfully applied for the in vitro inhibition of metabolism of dextromethorphan by CYP2D6 and CYP3A4 using known inhibitors of CYPs such as quinidine and verapamil. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

13.
A selective, rapid, and sensitive liquid chromatography–tandem mass spectrometry(LC‐MS/MS) method was developed and validated for the determination of letrozole (LTZ) in human plasma, using anastrozole as internal standard (IS). Sample preparation was performed by one‐step protein precipitation with methanol. The analyte and IS were chromatographed on a reversed‐phase YMC‐ODS‐C18 column (2.0 × 100 mm i.d., 3 µm) with a flow rate of 0.3 mL/min. The mobile phase consisted of water containing 0.1% formic acid (v/v) and methanol containing 0.1% formic acid (v/v). The mass spectrometer was operated in selected reaction monitoring mode through electrospray ionization ion mode using the transitions of m/z 286.2 → 217.1 for LTZ and m/z 294.1 → 225.1 for IS, respectively. The method was validated for selectivity, linearity, lower limit of quantitation, precision, accuracy, matrix effects and stability in accordance with the US Food and Drug Administration guidelines. Linear calibration curves were 1.0–60.0 ng/mL. Intra‐ and inter‐batch precision (CV) for LTZ were <9.34%, and the accuracy ranged from 97.43 to 105.17%. This method was successfully used for the analysis of samples from patients treated with LTZ in the dose of 2.5 mg/day. It might be suitable for therapeutic drug monitoring of these patients and contribute to predict the risk of adverse reactions. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

14.
A rapid and sensitive high‐performance LC‐MS/MS method was developed and validated for the simultaneous quantification of codeine and its metabolite morphine in human plasma using donepezil as an internal standard (IS). Following a single liquid‐liquid extraction with ethyl acetate, the analytes were separated using an isocratic mobile phase on a C18 column and analyzed by MS/MS in the selected reaction monitoring mode using the respective [M+H]+ ions, mass‐to‐charge ratio (m/z) 300/165 for codeine, m/z 286/165 for morphine and m/z 380/91 for IS. The method exhibited a linear dynamic range of 0.2–100/0.5–250 ng/mL for codeine/morphine in human plasma, respectively. The lower LOQs were 0.2 and 0.5 ng/mL for codeine and its metabolite morphine using 0.5 mL of human plasma. Acceptable precision and accuracy were obtained for concentrations over the standard curve range. A run time of 2.0 min for each sample made it possible to analyze more than 300 human plasma samples per day. The validated LC‐MS/MS method was applied to a pharmacokinetic study in which healthy Chinese volunteers each received a single oral dose of 30 mg codeine phosphate.  相似文献   

15.
The purpose of this study was to validate a reversed‐phase high‐performance liquid chromatographic (HPLC), tandem mass spectrometry (MS/MS) assay for the determination of telaprevir and its R‐diastereomer (VRT‐127394) in acidified and nonacidified human plasma. The chromatographic baseline separation of telaprevir and telaprevir‐R was performed on a Waters XBridgeTM BEH Shield C18, 2.1 × 75 mm column with a 2.5 µm particle size, under isocratic conditions consisting of a mobile phase of 50:45:5 water–acetonitrile–isopropanol with 1% ammonia at 0.2 mL/min. This method utilized a stable isotope internal standard with 11 deuterium atoms on the structure of the telaprevir molecule (telaprevir‐d11). An internal standard for the telaprevir‐R (telaprevir‐R‐d11) was also prepared by incubating telaprevir‐d11 in basic solution, which facilitated isomer inter‐conversion. The detection and quantitation of telaprevir, telaprevir‐R, telaprevir‐IS and telaprevir‐R‐IS was achieved by positive ion electrospray (ESI+) MS/MS detection. The assay quantifiable limit was 5.0 ng/mL when 0.100 mL of acidified human plasma was extracted. Accuracy and precision were validated over the calibration range of 5.0–5000 ng/mL. It was demonstrated using patient samples that, contrary to previous recommendations, quantitation of telaprevir does not require acidified plasma. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

16.
We developed and validated a simple, sensitive, selective and reliable LC–ESI‐MS/MS method for direct quantitation of dropropizine enantiomers namely levodropropizine (LDP) and dextrodropropizine (DDP) in rat plasma without the need for derivatization as per regulatory guidelines. Dropropizine enantiomers and carbamazepine (internal standard) were extracted from 50 μL rat plasma using ethyl acetate. LDP and DDP resolved with good baseline separation (Rs = 4.45) on a Chiralpak IG‐3 column. The mobile phase consisted of methanol with 0.05% diethylamine pumped at a flow rate of 0.5 mL/min. Detection and quantitation were done in multiple reaction monitoring mode following the transitions m/z 237 → 160 and 237 → 194 for dropropizine enantiomers and the internal standard, respectively, in the positive ionization mode. The proposed method provided accurate and reproducible results over the linearity range of 3.23–2022 ng/mL for each enantiomer. The intra‐ and inter‐day precisions were in the ranges of 3.38–13.6 and 5.11–13.8 for LDP and 4.19–11.8 and 8.89–10.1 for DDP. Both LDP and DDP were found to be stable under different stability conditions. The method was successfully used in a stereoselective pharmacokinetic study of dropropizine enantiomers in rats following oral administration of racemate dropropizine at 100 mg/kg. The pharmacokinetic results indicate that the disposition of dropropizine enantiomers is not stereoselective and chiral inversion does not occur in rats.  相似文献   

17.
A sensitive and reliable liquid chromatography tandem mass spectrometry (LC–MS/MS) method was developed to determine cyanidin‐3‐O‐glucoside (Cy‐3G) in normal and streptozotocin‐induced diabetic rat plasma. Chromatographic separation was carried out on a Zorbax SB‐C18 (50 × 4.6 mm, 5 μm) column and mass spectrometric analysis was performed using a Thermo Finnigan TSQ Quantum Ultra triple‐quadrupole mass spectrometer coupled with an ESI source in the negative ion mode. Selected reaction monitoring mode was applied for quantification using target fragment ions m/z 447.3 → 285.2 for Cy‐3G and m/z 463.0 → 300.1 for quercetin‐3‐O‐glucoside (internal standard). The calibration curve was linear over the range 3.00–2700 ng/mL (r2 ≥ 0.99) with the lower limit of quantitation at 3.00 ng/mL. Intra‐ and inter‐day precision was <14.5% and mean accuracy was from −11.5 to 13.6%. Stability testing showed that Cy‐3G remained stable during the whole analytical procedure. After validation, the assay was successfully used to support a preclinical pharmacokinetic comparison of Cy‐3G between normal and diabetic rats. Results indicated that diabetes mellitus significantly altered the in vivo pharmacokinetic characteristics of Cy‐3G after oral administration in rats.  相似文献   

18.
A sensitive and reliable GC‐MS method was developed and validated for the simultaneous determination of ascaridole, p‐cymene and α‐terpinene in rat plasma using naphthalene as internal standard. The plasma samples were extracted with ethyl acetate. Chromatographic separation was carried out on a HP‐5MS capillary analytical column (30 m × 0.25 mm, 0.25 µm) and detection was performed on a quadrupole mass spectrometer detector operated under selected ion monitoring mode. The method showed excellent linearity over the investigated concentration range (r > 0.99) with the limit of quantitation down to 50, 10 and 5 ng/mL for ascaridole, p‐cymene and α‐terpinene, respectively. The intra‐day and inter‐day precisions (RSD) were <11.3%, and the accuracy was between 90.7 and 113.8%. The method was successfully applied to investigate the pharmacokinetics of Chenopodium ambrosioides L. following oral administration to rats. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

19.
In this study, a liquid chromatography–tandem mass spectrometry (LC‐MS/MS) method was developed and validated to simultaneously determine the anticancer drugs etoposide and paclitaxel in mouse plasma and tissues including liver, kidney, lung, heart, spleen and brain. The analytes were extracted from the matrices of interest by liquid–liquid extraction using methyl tert‐butyl ether–dichloromethane (1:1, v/v). Chromatographic separation was achieved on an Ultimate XB‐C18 column (100 × 2.1 mm, 3 μm) at 40°C and the total run time was 4 min under a gradient elution. Ionization was conducted using electrospray ionization in the positive mode. Stable isotope etoposide‐d3 and docetaxel were used as the internal standards. The lower limit of quantitation (LLOQ) of etoposide was 1 ng/g tissue for all tissues and 0.5 ng/mL for plasma. The LLOQ of paclitaxel was 0.4 ng/g tissue and 0.2 ng/mL for all tissues and plasma, respectively. The coefficients of correlation for all of the analytes in the tissues and plasma were >0.99. Both intra‐ and inter‐day accuracy and precision were satisfactory. This method was successfully applied to measure plasma and tissue drug concentrations in mice treated with etoposide and paclitaxel‐loaded self‐microemulsifying drug‐delivery systems.  相似文献   

20.
A highly sensitive, rapid assay method has been developed and validated for the estimation of S‐citalopram (S‐CPM) in rat plasma with liquid chromatography coupled to tandem mass spectrometry with electrospray ionization in the positive‐ion mode. The assay procedure involves a simple liquid–liquid extraction of S‐CPM and phenacetin (internal standard, IS) from rat plasma with t‐butyl methyl ether. Chromatographic separation was operated with 0.2% formic acid:acetonitrile (20:80, v/v) at a flow rate of 0.50 mL/min on a Symmetry Shield RP18 column with a total run time of 3.0 min. The MS/MS ion transitions monitored were 325.26 → 109.10 for S‐CPM and 180.10 → 110.10 for IS. Method validation and pre‐clinical sample analysis were performed as per FDA guidelines and the results met the acceptance criteria. The lower limit of quantitation achieved was 0.5 ng/mL and the linearity was observed from 0.5 to 5000 ng/mL. The intra‐ and inter‐day precisions were in the range of 1.14–5.56 and 0.25–12.3%, respectively. This novel method has been applied to a pharmacokinetic study and to estimate brain‐to‐plasma ratio of S‐CPM in rats. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号