共查询到20条相似文献,搜索用时 0 毫秒
1.
《Angewandte Chemie (Weinheim an der Bergstrasse, Germany)》2017,129(24):6922-6926
Motion tracking of microorganisms is useful to investigate the effects of chemical or physical stimulation on their biological functions. Herein, we describe a novel electrochemical imaging method for motion tracking of microorganisms using a large‐scale integration (LSI)‐based amperometric device. The device consists of 400 electrochemical sensors with a pitch of 250 μm. A convection flow caused by the motion of microorganisms supplies redox species to the sensors and increases their electrochemical responses. Thus, the flow is converted to electrochemical signals, enabling the electrochemical motion tracking of the microorganisms. As a proof of concept, capillary vibration was monitored. Finally, the method was applied to monitoring the motion of Daphnia magna . The motions of these microorganisms were clearly tracked based on the electrochemical oxidation of [Fe(CN)6]4− and reduction of O2. 相似文献
2.
《Angewandte Chemie (Weinheim an der Bergstrasse, Germany)》2017,129(24):6990-6994
Antimicrobial resistance (AMR), the ability of a bacterial species to resist the action of an antimicrobial drug, has been on the rise due to the widespread use of antimicrobial agents. Per the World Health Organization, AMR has an estimated annual cost of USD 34 billion in the US and is predicted to be the number one cause of death worldwide by 2050. One way AMR bacteria can spread, and by which individuals can contract AMR infections, is through contaminated water. Monitoring AMR bacteria in the environment currently requires that samples be transported to a central laboratory for slow and labor intensive tests. We have developed an inexpensive assay using paper‐based analytical devices (PADs) that can test for the presence of β‐lactamase‐mediated resistance. To demonstrate viability, the PAD was used to detect β‐lactam resistance in wastewater and sewage and identified resistance in individual bacterial species isolated from environmental water sources. 相似文献
3.
Kentaro Yamada Prof. Dr. Terence G. Henares Prof. Dr. Koji Suzuki Prof. Dr. Daniel Citterio 《Angewandte Chemie (International ed. in English)》2015,54(18):5294-5310
Rapid, precise, and reproducible deposition of a broad variety of functional materials, including analytical assay reagents and biomolecules, has made inkjet printing an effective tool for the fabrication of microanalytical devices. A ubiquitous office device as simple as a standard desktop printer with its multiple ink cartridges can be used for this purpose. This Review discusses the combination of inkjet printing technology with paper as a printing substrate for the fabrication of microfluidic paper‐based analytical devices (μPADs), which have developed into a fast‐growing new field in analytical chemistry. After introducing the fundamentals of μPADs and inkjet printing, it touches on topics such as the microfluidic patterning of paper, tailored arrangement of materials, and functionalities achievable exclusively by the inkjet deposition of analytical assay components, before concluding with an outlook on future perspectives. 相似文献
4.
《Angewandte Chemie (Weinheim an der Bergstrasse, Germany)》2017,129(26):7600-7603
The real‐time monitoring of specific analytes in situ in the living body would greatly advance our understanding of physiology and the development of personalized medicine. Because they are continuous (wash‐free and reagentless) and are able to work in complex media (e.g., undiluted serum), electrochemical aptamer‐based (E‐AB) sensors are promising candidates to fill this role. E‐AB sensors suffer, however, from often‐severe baseline drift when deployed in undiluted whole blood either in vitro or in vivo. We demonstrate that cell‐membrane‐mimicking phosphatidylcholine (PC)‐terminated monolayers improve the performance of E‐AB sensors, reducing the baseline drift from around 70 % to just a few percent after several hours in flowing whole blood in vitro. With this improvement comes the ability to deploy E‐AB sensors directly in situ in the veins of live animals, achieving micromolar precision over many hours without the use of physical barriers or active drift‐correction algorithms. 相似文献
5.
6.
Jaruwan Mettakoonpitak Katherine Boehle Siriwan Nantaphol Prinjaporn Teengam Jaclyn A. Adkins Monpichar Srisa‐Art Charles S. Henry 《Electroanalysis》2016,28(7):1420-1436
Even though they were introduced less than a decade ago, electrochemical paper‐based devices (ePADs) have attracted widespread attention because of their inherent advantages in many applications. ePADs combine the advantages of microfluidic paper‐based devices (low cost, ease of use, equipment free pumping, etc.) for sample handling and processing with the advantages of sensitive and selective detection provided by electrochemistry. As a result, ePADs provide simplicity, portability, reproducibility, low cost and high selectivity and sensitivity for analytical measurements in a variety of applications ranging from clinical diagnostics to environmental sensing. Herein, recent advances in ePAD development and application are reviewed, focusing on electrode fabrication techniques and examples of applications specially focused on environmental monitoring, biological applications and clinical assays. Finally, a summary and prospective directions for ePAD research are also provided. 相似文献
7.
8.
9.
10.
Zijie Luo Taoyuze Lv Kangning Zhu Yi Li Lei Wang J. Justin Gooding Guozhen Liu Bin Liu 《Angewandte Chemie (International ed. in English)》2020,59(8):3131-3136
Monitoring of human serum albumin (HSA) in a point‐of‐care fashion is urgently needed in particular for elderly or chronically ill patients. Herein, a dual‐state emissive chalcone probe having the feature of aggregation‐induced emission was designed and synthesized. The concentration of HSA can be evaluated by the ratios of emission from probes in aggregated and monomeric state, which gives a visually discernible red‐to‐green color change. A simple, portable paper‐based analytical device have been fabricated by integration of the recognition probe in the detection pad and employed for HSA test using the whole blood samples. This paper‐based assay shows the analytical capability comparable to the standard testing methods but is in a point‐of‐care fashion, providing a promising tool for at‐home HSA detection and HSA‐related disease diagnosis. 相似文献
11.
12.
13.
14.
15.
16.
17.
18.
19.
Jiasheng Qian Huanyu Jin Dr. Bolei Chen Mei Lin Dr. Wei Lu Dr. Wing Man Tang Dr. Wei Xiong Prof. Lai Wa Helen Chan Prof. Shu Ping Lau Dr. Jikang Yuan 《Angewandte Chemie (International ed. in English)》2015,54(23):6800-6803
We report a simple approach based on a chemical reduction method to synthesize aqueous inorganic ink comprised of hexagonal MnO2 nanosheets. The MnO2 ink exhibits long‐term stability and continuous thin films can be formed on various substrates without using any binder. To obtain a flexible electrode for capacitive energy storage, the MnO2 ink was printed onto commercially available A4 paper pretreated with multiwalled carbon nanotubes. The electrode exhibited a maximum specific capacitance of 1035 F g?1 (91.7 mF cm?2). Paper‐based symmetric and asymmetric capacitors were assembled, which gave a maximum specific energy density of 25.3 Wh kg?1 and a power density of 81 kW kg?1. The device could maintain a 98.9 % capacitance retention over 10 000 cycles at 4 A g?1. The MnO2 ink could be a versatile candidate for large‐scale production of flexible and printable electronic devices for energy storage and conversion. 相似文献